c# free pdf viewer : Add document to pdf pages Library application component .net html web page mvc R&S%20ZVL-MANUAL47-part771

R&S
®
ZVL 
Programming Examples 
Basic Tasks 
Operating Manual 1303.6580.32-01 
471 
// 
// 
// 2. One channel, two traces, two diagram areas  
// Create a second diagram area, assign Trc2 to the new area, and remove it from the first area.  
DISPlay:WINDow2:STATe ON  
DISPlay:WINDow2:TRACe2:FEED 'Trc2'  // Trc2 is now displayed in both diagram areas   
DISPlay:WINDow1:TRACe2:DELete  
// 
// 
Check the result on the local screen  
// Go to local  
SYSTem:DISPlay:UPDate ONCE 
Add document to pdf pages - insert pages into PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide C# Users to Insert (Empty) PDF Page or Pages from a Supported File Format
add multi page pdf to word document; add pages to pdf online
Add document to pdf pages - VB.NET PDF Page Insert Library: insert pages into PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use VB.NET APIs to Add a New Blank Page to PDF Document
add page numbers to pdf document in preview; add page number to pdf print
R&S
®
ZVL 
Programming Examples 
Basic Tasks 
Operating Manual 1303.6580.32-01 
472 
// 
// 
// 3. One channel, four traces, four diagram areas  
// Reset the instrument, add diagram areas no. 2, 3, 4.  
*RST; :DISPlay:WINDow2:STATe ON  
DISPlay:WINDow3:STATe ON  
DISPlay:WINDow4:STATe ON  
// 
// Assign the reflection parameter S11 to the default trace.  
:CALCulate1:PARameter:MEASure 'Trc1', 'S11'  
// 
// Assign the remaining S-parameters to new traces Trc2, Trc3, Tr4;  
// select the Smith chart format for the reflection parameters.  
CALCulate1:FORMat SMITh  // Smith chart for the active trace Trc1  
CALCulate1:PARameter:SDEFine 'Trc2', 'S21' 
CALCulate1:PARameter:SDEFine 'Trc3', 'S12' 
C# PDF Page Extract Library: copy, paste, cut PDF pages in C#.net
pageIndexes.Add(3); // The 4th page. Create the new document with 3 String outputFilePath = Program.RootPath + "\\" Output.pdf"; newDoc.Save(outputFilePath
adding page numbers to a pdf document; add and remove pages from a pdf
VB.NET PDF Page Extract Library: copy, paste, cut PDF pages in vb.
pageIndexes.Add(3) ' The 4th page Create the new document with 3 Dim outputFilePath As String = Program.RootPath + "\\" Output.pdf" newDoc.Save(outputFilePath
add page to pdf without acrobat; add page number to pdf file
R&S
®
ZVL 
Programming Examples 
Basic Tasks 
Operating Manual 1303.6580.32-01 
473 
CALCulate1:PARameter:SDEFine 'Trc4', 'S22'  
CALCulate1:FORMat SMITh  // Smith chart for the active trace Trc4, referenced by the channel 
number   
// 
// Display the new traces in diagram areas no. 2 to 4.  
DISPlay:WINDow2:TRACe2:FEED 'Trc2' 
DISPlay:WINDow3:TRACe3:FEED 'Trc3' 
DISPlay:WINDow4:TRACe4:FEED 'Trc4' 
// 
// 
Check the result on the local screen  
// Go to local  
SYSTem:DISPlay:UPDate ONCE 
// 
// 
Check the result in the trace manager  
// The trace manager gives an overview of the current channel/trace configuration  
DISPlay:MENU:KEY:EXECute 'Trace Manager' 
VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
Add necessary references: RasterEdge.Imaging.Basic.dll. This is a VB .NET example for how to delete a range of pages from a PDF document.
adding page numbers to pdf files; adding page numbers to a pdf file
C# PDF Page Delete Library: remove PDF pages in C#.net, ASP.NET
options, including setting a single page, a series of pages, and random pages to be C#.NET Project DLLs for Deleting PDF Document Page. Add necessary references
add page number to pdf reader; adding a page to a pdf document
R&S
®
ZVL 
Programming Examples 
Basic Tasks 
Operating Manual 1303.6580.32-01 
474 
Several Traces with Different Channel Settings... 
Programming task: Create three channels with 3, 1 and 2 traces, respectively, and display the traces in 
two diagram areas.   
Important remote control features for this program example  
The following command sequence illustrates the structure of the remote commands discussed in section 
Basic Remote Control Concepts. In particular it shows that:  
! Channels are always referenced by a channel suffix.  
! Traces are referenced by trace names. The active trace of a channel is often referenced by the 
channel suffix.  
VB.NET PDF insert image library: insert images into PDF in vb.net
VB.NET PDF - Add Image to PDF Page in VB.NET. Guide VB.NET Programmers How to Add Images in PDF Document Using XDoc.PDF SDK for VB.NET.
add page pdf; add a page to a pdf document
C# PDF Password Library: add, remove, edit PDF file password in C#
in C#.NET framework. Support to add password to PDF document online or in C#.NET WinForms for PDF file protection. Able to create a
add pages to pdf without acrobat; adding pages to a pdf document
R&S
®
ZVL 
Programming Examples 
Basic Tasks 
Operating Manual 1303.6580.32-01 
475 
! Diagram areas are referenced by a window suffix <Wnd>. An additional suffix <WndTr> in the 
DISPlay:WINDow<Wnd>:TRACe<WndTr>... commands numbers the different traces in a 
diagram area.  
! The analyzer provides several commands allowing a smooth transition between remote and 
manual control.  
// 
// 1. Create all channels and traces  
// Reset the instrument, creating the default trace Trc1 in channel 1.  
// The default measured quantity is the forward transmission S-parameter S21.  
// The default format is dB Mag. 
*RST 
// 
// Create two more traces in channel 1, assigning a trace name and a measured quantity  
// to each of themChoose descriptive trace names (instead of the short default names used above).  
CALCulate1:PARameter:SDEFine 'Impedance_trace', 'Z-S21'  // the trace becomes the active trace 
for channel 1 but is not displayed  
CALCulate1:PARameter:SDEFine 'Admittance_trace', 'Y-S21'  // the trace becomes the active trace 
for channel 1  
// 
// Create channel 2 with one new trace, channel 3 with two new traces.  
CALCulate2:PARameter:SDEFine 'Ratio_trace', 'B1/B2'  
CALCulate3:PARameter:SDEFine 'Z_trace', 'Z21'   
CALCulate3:PARameter:SDEFine 'Y_trace', 'Y21'   
CALCulate3:PARameter:SELect 'Z_trace'  //  the trace created previously becomes the active 
trace for channel 3 
// So far, only the default trace is displayed.  
// 
// 
Check the result in the trace manager  
// The trace manager gives an overview of the current channel/trace configuration  
DISPlay:MENU:KEY:EXECute 'Trace Manager' 
C# PDF insert image Library: insert images into PDF in C#.net, ASP
Create high resolution PDF file without image quality losing in ASP.NET application. Add multiple images to multipage PDF document in .NET WinForms.
add page to pdf online; add document to pdf pages
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
Document Protect. Password: Set File Permissions. Password: Open Document. Edit Digital Highlight Text. Add Text. Add Text Box. Drawing Markups. PDF Print. Work
add a blank page to a pdf; add page numbers to a pdf
R&S
®
ZVL 
Programming Examples 
Basic Tasks 
Operating Manual 1303.6580.32-01 
476 
// 
// 
Check the result on the local screen  
// Go to local  
SYSTem:DISPlay:UPDate ONCE 
// 
// 
R&S
®
ZVL 
Programming Examples 
Basic Tasks 
Operating Manual 1303.6580.32-01 
477 
// 2. Create second diagram area and display traces  
DISPlay:WINDow2:STATe ON  
DISPlay:WINDow1:TRACe2:FEED 'Admittance_trace' 
DISPlay:WINDow1:TRACe3:FEED 'Y_trace' 
DISPlay:WINDow2:TRACe1:FEED 'Impedance_trace' 
DISPlay:WINDow2:TRACe2:FEED 'Ratio_trace' 
DISPlay:WINDow2:TRACe3:FEED 'Z_trace' 
// 
// 
Check the result on the local screen  
// Go to local  
SYSTem:DISPlay:UPDate ONCE 
// 
// 
// 3. Check and modify your configuration  
// Query the traces in channel 1.  
CALCulate1:PARameter:CATalog?  
R&S
®
ZVL 
Programming Examples 
Basic Tasks 
Operating Manual 1303.6580.32-01 
478 
// The response is 'Trc1,S21,Impedance_trace,Z-S21,Admittance_trace,Y-S21'  
// 
// Query the reference level for the 'Z_trace'.  
// The trace is referenced by its number in diagram area no. 2.  
DISPlay:WINDow2:TRACe3:Y:RLEVel?  
// 
// Change the display format for the 'Z_trace'. The trace is the active trace in channel 3,  
// so it is referenced by the channel suffix 3.  
CALCulate3:FORMat PHASe  
Markers and Limit Lines... 
Programming task: Display two traces in a single diagram ares, use markers to read results, and perform 
a limit check.   
Important remote control features for this program example  
The following command sequence illustrates the structure of the remote commands discussed in section 
Basic Remote Control Concepts. In particular it shows that:  
! Traces are referenced by trace names. The active trace of a channel is often referenced by the 
channel suffix. This simplifies the program syntax, e.g. in the commands for marker settings and 
for the limit check.  
R&S
®
ZVL 
Programming Examples 
Basic Tasks 
Operating Manual 1303.6580.32-01 
479 
! Diagram areas are referenced by a window suffix <Wnd>. An additional suffix <WndTr> in the 
DISPlay:WINDow<Wnd>:TRACe<WndTr>... commands numbers the different traces in a 
diagram area.  
! The analyzer provides several commands allowing a smooth transition between remote and 
manual control.  
// 
// 
// 1. Create one channel, two traces, one diagram area  
// Reset the instrument, creating the default trace Trc1 in channel 1.  
// The default measured quantity is the forward transmission S-parameter S21.  
// The default format is dB Mag. 
*RST 
// 
// 
Create 
second 
trace 
in 
channel 
1, 
assign 
the 
format 
Phase,  
// and display the new trace in the same diagram area.  
CALCulate1:PARameter:SDEFine 'Trc2', 'S21'  // the trace becomes the active trace but is not 
displayed  
CALCulate1:FORMat PHASe  // the trace is referenced by the channel suffix 1  
DISPlay:WINDow1:TRACe2:FEED 'Trc2'  // display the second trace, numbering it the second 
trace in diagram area no. 1   
// 
// 
Check the result on the local screen  
// Go to local  
SYSTem:DISPlay:UPDate ONCE 
R&S
®
ZVL 
Programming Examples 
Basic Tasks 
Operating Manual 1303.6580.32-01 
480 
// 
// 
// 2. Marker settings  
// Adjust the sweep range to consider an interesting segment of the trace and re-scale the diagram.  
SENSe1:FREQuency:STARt 4.5 GHz; STOP 5.5 GHz  
DISPlay:WINDow1:TRACe1:Y:SCALe:AUTO ONCE  / in the autoscale command the trace is 
referenced by its number in the diagram  
// 
// Select trace Trc1 as the active trace of the channel, define a reference marker and a delta marker.  
// In the marker commands the active trace is referenced by the channel suffix.  
CALCulate1:PARameter:SELect 'Trc1'  
CALCulate1:MARKer1:STATe ON  // the marker is set to the center of the sweep range 
CALCulate1:MARKer1:DELTa:STATe ON  // this command also creates the reference marker 
CALCulate1:MARKer1:REFerence:X 4.5 GHz  // set the reference marker to the beginning 
of the sweep range  
// 
// Use the delta marker to search for the minimum of the trace and query the result.  