c# free pdf viewer : Add contents page to pdf SDK control service wpf azure html dnn R&S%20ZVL-MANUAL6-part776

R&S
®
ZVL 
System Overview 
Basic Concepts 
Quick Start Guide 1303.6538.62-01 
61 
MEM
( TRACE 1)
S - Parameters
Data Access Points:
1, 2 Import/Export Data
3     Apply cal pool data / copy to cal pool 
*
MEM
( TRACE 2)
Channel data flow
(for all traces of the channel)
Trace data flow
(for individual traces)
1
SYSTEM
ERROR
CORR.
SYSTEM
ERROR CORR. DATA
3
OFFSET
COMPLEX
CONVERS.
*
2
MATH
Add contents page to pdf - insert pages into PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide C# Users to Insert (Empty) PDF Page or Pages from a Supported File Format
add page number to pdf document; add page number to pdf
Add contents page to pdf - VB.NET PDF Page Insert Library: insert pages into PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use VB.NET APIs to Add a New Blank Page to PDF Document
add pages to pdf file; add page numbers to pdf in preview
R&S
®
ZVL 
System Overview 
Basic Concepts 
Quick Start Guide 1303.6538.62-01 
62 
3.1.4 Navigation Tools of the Screen 
This section describes the operating concept of the network analyzer, including the 
alternative navigation tools for mouse and hardkey operation, the trace settings, 
markers and diagram areas. For a description of the different quantities measured by 
the analyzer refer to the Measured Quantities section.   
The main window of the analyzer provides all control elements for the measurements 
and contains the diagram areas for the results. There are several alternative ways to 
access an instrument function:  
Using the menus and submenus of the menu bar (provides all settings) 
Using the softkeys of the softkey bar (alternative to the previous method)  
Using the hardkey bar (preselection of the most important menus) 
Refer to section Display Elements to obtain information about the results in the 
diagram area.  
Refer to section Display Menu in the reference chapter and learn how to customize 
the screen.  
3.1.4.1 Menu Bar 
All analyzer functions are arranged in drop-down menus. The menu bar is located 
across the top of the diagram area: 
Menus can be controlled in different ways: 
How to C#: Basic SDK Concept of XDoc.PDF for .NET
You may add PDF document protection functionality into your C# program. This class provides APIs for manipulating image contents in a PDF page. PDFImage.
adding page to pdf in preview; adding page numbers pdf
C# WinForms Viewer: Load, View, Convert, Annotate and Edit Excel
from Excel document to PDF, Tiff and HTML file. Users can add annotations to Excel when viewing it on C# WinForms Viewer and manipulate text contents on Excel
add page to pdf preview; add a page to a pdf in reader
R&S
®
ZVL 
System Overview 
Basic Concepts 
Quick Start Guide 1303.6538.62-01 
63 
With a mouse, like the menus in any Windows application. A left mouse click 
expands a menu or submenu. If a menu command has no submenu assigned, a 
left mouse click opens a dialog or directly activates the menu command.  
Using the front panel keys.  
With a combination of the previous methods, using the hardkey bar (front panel key 
bar, activated via Setup/Display Config./Front Panel Keys).  
The active menu is the menu containing the last executed command.  
When you select a command in a new menu the softkey bar is updated to reflect the 
new active menu with all commands. You can continue operation using the softkeys.  
Overview of menu functions 
The Control  
menus provide standard Windows functions to control windows.  
The File menu provides standard Windows functions to create, save or recall 
setups and to shut down the application.  
The Trace menu provides all trace settings and the functions to create, select, 
modify and store different traces. In addition the menu provides the marker, search 
and limit check functions.  
The Channel menu provides all channel settings and the functions to create, select, 
modify and store different channels. This incudes the functions for calibration.  
The Display menu provides all display settings and the functions to create, select, 
modify and arrange different diagram areas.  
The NWA-Setup menu provides standard Windows™ functions to arrange different 
windows on the screen, display options, reverse operations, return to a defined 
instrument state, and retrieve information on the instrument. Besides, it provides 
configurations for the user interface and for remote control operation.  
The Help menu provides assistance with the network analyzer and its operation.  
3.1.4.2 Menu Structure 
All menus show an analogous structure.   
C# WPF Viewer: Load, View, Convert, Annotate and Edit Excel
Excel Conversion. • Convert Microsoft Office Excel to PDF (.pdf). Add annotation comments to Excel. Miscellaneous. • Select Excel text contents on viewer.
add a page to a pdf in acrobat; adding page numbers in pdf file
VB.NET PDF: Basic SDK Concept of XDoc.PDF
You may add PDF document protection functionality into your VB.NET program. This class provides APIs for manipulating image contents in a PDF page.
add page to pdf reader; add page to existing pdf file
R&S
®
ZVL 
System Overview 
Basic Concepts 
Quick Start Guide 1303.6538.62-01 
64 
A menu command with a right arrow 
expands a submenu with further related 
settings. Example: Marker 
expands a submenu to position markers on a trace 
and configure their properties. 
A menu command with three dots appended calls up an input field or a dialog 
providing several related settings. Example: Marker 1... opens an input field to 
enter the frequency of marker 1. 
A menu command with no arrow or dots directly initiates an action. Example: Delta 
Mode converts the active marker to a delta marker.  
A dot preceding the menu command indicates the current selection in a list of 
alternative settings. Example: In the figure above, the default format is selected as 
marker format.  
3.1.4.3 Softkey Bar 
The softkey bar displays the commands of the active menu so that they can be 
activated by hitting the associated keys on the front panel. It contains two different 
softkey types: 
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit Excel
Users can add annotations to Excel when viewing it Following contents clearly show these features, they are including HTML file and create multi-page tiff file
adding pages to a pdf document in preview; add a page to a pdf document
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit PDF
Following contents will explain supported PDF processing Users can freely add text annotation, freehand lines, figures and highlight annotations to PDF page.
adding a page to a pdf in preview; adding page to pdf
R&S
®
ZVL 
System Overview 
Basic Concepts 
Quick Start Guide 1303.6538.62-01 
65 
Function softkeys 
... 
... 
Up to 7 softkeys, each corresponding to a command of the active menu. The function 
of the softkeys and their labels are strictly equivalent to the corresponding menu 
commands.    
Three dots indicate that the softkey calls up a dialog providing several related 
settings. 
A down arrow 
indicates a submenu with further related settings.  
A softkey with no arrow or dots directly initiates an action.  
Navigation softkey (optional)  
Softkey no. 7 is reserved for navigation:  
More 1/2More 2/2 etc.toggle between groups of softkeys which belong to the same 
menu. The softkeys are provided whenever the active menu contains more than 6 
commands.  
The lowest front panel key to the right of the display activates the higher-level menu. 
This works in all menus except the top-level one listing the main menus in the menu 
bar. 
The softkey bar is automatically updated when the active menu is changed.  
TIP 
Hiding display elements  
You can hide the softkey bar and gain screen space for the diagram areas if you use 
a mouse to control the analyzer (see Setup/Display Config.). All settings are 
accessible from the menus listed in the menu bar across the top of the screen. 
Moreover, you don't have to display the softkey bar permanently in order to make use 
of its functionality. Hitting any of the keys associated to the softkey bar will make it 
visible for a period of time sufficient to select the next instrument function. 
3.1.4.4 Front Panel Key Bar 
The front panel key bar (hardkey bar, Setup/Display Config.) displays the most 
commonly used setup and function keys of the analyzer. Clicking a key symbol 
executes the action of the corresponding key.  
VB.NET PDF Page Replace Library: replace PDF pages in C#.net, ASP.
Able to replace all PDF page contents in VB.NET, including text, image Replace a Page (in a PDFDocument Object) by a PDF Page Object. Add necessary references:
add page pdf; add page to pdf online
VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.
Converted HTML files preserve all the contents of source PDF file, like font Add necessary references: is designed to convert PDF file to HTML web page using VB
add page number to pdf in preview; add page numbers to a pdf
R&S
®
ZVL 
System Overview 
Basic Concepts 
Quick Start Guide 1303.6538.62-01 
66 
The front panel key bar provides access to the basic groups of settings with a single 
mouse click. It is particularly useful if the analyzer is controlled with a mouse or via 
Remote Desktop. Alternatively the settings are accessible from the menus of the menu 
bar or from the softkey bar.  
The front panel key bar is hidden by default to gain screen space for the diagram 
areas.   
3.1.4.5 Status Bar 
The status bar (Setup/Display Config.) describes the current channel (if the setup 
contains only one channel), the progress of the sweep, and the control mode of the 
analyzer (LOCAL or REMOTE).  
During sweep initialization, the progress bar for the sweep is replaced by a 
symbol. During the first sweep after a change of the channel settings, 
an additional red asterisk symbol appears:  
You can hide the status bar and gain screen space for the diagram areas.   
3.1.5 Display Elements in the Diagram Area     
The central part of the screen is occupied by one or several diagram areas.  
Diagram Areas 
A diagram area is a rectangular portion of the screen used to display traces. Diagram 
areas are arranged in windows; they are independent of trace and channel settings. A 
diagram area can contain a practically unlimited number of traces, assigned to different 
channels (overlay mode).   
Diagram areas are controlled and configured by means of the functions in the Display 
menu and the following additional settings:  
The settings in the Nwa-Setup – Display submenu arrange several windows 
containing one or more diagram areas within the entire screen. Each window 
corresponds to a setup. Only one setup can be active at a time, and only the traces 
of the active setup are updated by the current measurements.  
Various settings to assign traces to diagram areas are provided in the Trace – 
Trace-> – Traces submenu.    
Diagram areas may contain:  
Measurement results, in particular the traces and marker values   
C# PDF File Compress Library: Compress reduce PDF size in C#.net
Delete unimportant contents: Flatten form fields. Alternate images. Embedded page thumbnails. Document tags. Add necessary references: RasterEdge.Imaging.Basic.dll
adding a page to a pdf document; add page to a pdf
VB.NET PDF File Compress Library: Compress reduce PDF size in vb.
resources: Since images are usually or large size, images size reducing can help to reduce PDF file size Delete unimportant contents: Embedded page thumbnails.
add document to pdf pages; add a page to a pdf
R&S
®
ZVL 
System Overview 
Basic Concepts 
Quick Start Guide 1303.6538.62-01 
67 
An indication of the basic channel and trace settings   
Context menus providing settings related to the current screen  
The examples in this section have been taken from Cartesian diagrams. All other 
diagram types provide the same display elements.  
3.1.5.1 Title 
Across the top of the diagram area, an optional title describes the contents of the area. 
Different areas within a setup are distinguished by area numbers in the upper right 
corner.  
Use the context menu or the functions in the Display menu to display, hide or change 
the title and to add and customize diagram areas.  
3.1.5.2 Traces     
A trace is a set of data points displayed together in the diagram area. The individual 
data points are connected so that each trace forms a continuous line.  
R&S
®
ZVL 
System Overview 
Basic Concepts 
Quick Start Guide 1303.6538.62-01 
68 
The trace can be complemented by the following display elements, plotted with the 
same color: 
Reference value (for all traces): The Reference Value is indicated with a triangle 
at the right edge of the diagram and a dashed, horizontal line. The value and 
position of the triangle can be changed in order to modify the diagram scale and 
shift the trace vertically.  
Measured quantity (for the active trace): The measured quantity is indicated in the 
left upper corner of the diagram.  
A trace can be either a data trace, a memory trace, or a mathematical trace; see Trace 
Types below.    
Context menu of the diagram area 
A right mouse click on any point of the diagram area (except the marker info field and 
the measured quantity info) opens a context menu:  
The settings correspond to the most common commands in the Nwa-Setup – Display 
and Nwa-Setup – Display Config menus.  
3.1.5.3 Trace Types     
The analyzer uses traces to display the current measurement result in a diagram area 
but is also capable of storing traces to the memory, recalling stored traces, and 
defining mathematical relations between different traces. There are three basic trace 
types: 
Data traces show the current measurement data and are continuously updated as 
the measurement goes on. Data traces are dynamic traces.    
Memory traces are generated by storing the data trace to the memory. It 
represents the state of the data trace at the moment when it was stored.Memory 
traces are static traces which can be stored to a file and recalled.  
R&S
®
ZVL 
System Overview 
Basic Concepts 
Quick Start Guide 1303.6538.62-01 
69 
Mathematical traces are calculated according to a mathematical relation between 
constants and the data or memory traces of the active setup. A mathematical trace 
that is based on the active data trace is dynamic.  
It is possible to generate an unlimited number of memory traces from a data trace and 
display them together, see Data -> Mem. Markers and marker functions are available 
for all trace types.   
The trace type of each trace in a diagram area is indicated in the trace list. You can 
also make each trace Invisible without deleting it.  
3.1.5.4 Trace List and Trace Settings     
The main properties of all traces assigned to the diagram area are displayed in the 
trace list in the upper left corner.  
Each line in the trace list describes a single trace. The active trace is highlighted. The 
lines are divided into several sections with the following contents (from left to right):  
Trace name indicates the current trace name. The default names for new traces 
are Trc<n> where <n> is a current number. A Mem... preceding the trace name 
indicates a memory trace.  Right-click the section and call the Trace Manager from 
the context menu to change the trace name.  
Measured quantity indicates the measured quantity, e.g. an S-parameter or an 
impedance. The measured quantity of the active trace is also displayed in the 
diagram area below the trace list.  
Format shows how the measured data is presented in the graphical display (trace 
format).  
Scale shows the value of the vertical or radial diagram divisions (Scale Div.) and 
the Reference Value.    
Channel shows the channel that each trace is assigned to. The channel section is 
omitted if the all traces in the diagram area are assigned to the same channel.  
Type shows Invisible if a trace is hidden and Math if the trace is a mathematical 
trace. GAT indicates that a time gate is active for the trace. Right-click the trace 
name and click Show Data or Show Mem from the context menu to display and 
hide data and memory traces. Use the Trace Funct(ions) to define mathematical 
traces. Right-click any of the sections in the trace list (except Type) to open a 
context menu and access the most common tasks related to the section.  
Context menus of the trace list 
A right mouse click on the trace name, the measured quantity, and the format and 
scale section of the trace list opens the following context menus, respectively:  
R&S
®
ZVL 
System Overview 
Basic Concepts 
Quick Start Guide 1303.6538.62-01 
70 
The settings correspond to the most common commands in the Trace – Trace Select, 
Trace – Trace Funct, Trace – Meas, Trace – Format and Trace – Scale menus.  
A red label Cal Off ! appears behind the trace list if the system error correction no 
longer applies to one or more traces; see Calibration Overview.  
3.1.5.5 Markers     
Markers are tools for selecting points on the trace and for numerical readout of 
measured data. The analyzer provides three different basic marker types.   
A (normal) marker (Mkr 1, Mkr 2, ...) determines the coordinates of a measurement 
point on the trace. Up to 10 different normal markers can be assigned to a trace.  
A reference marker (Ref) defines the reference value for all delta markers.  
A delta marker (
indicates the coordinates relative to the reference marker.  
The stimulus value of a discrete marker always coincides with a sweep point so 
that the marker does not show interpolated measurement values.  
The markers 1 to 4 are also used for bandfilter search mode. The examples below 
show a bandpass search and a bandstop search, respectively.  
Documents you may be interested
Documents you may be interested