c# free pdf viewer component : Add page number to pdf document software SDK project winforms .net web page UWP RefChap116-part930

Copyright © 2000 by Surfware, Inc. All Rights Reserved.
SURFCAM Reference Manual,  Chapter 1 •  Menus and Dialog Boxes
161
User Tolerance
SURFCAM will regard elements that do not come within this distance of each other to 
be not touching. As an example, a point will not be created at a selected intersection 
unless the actual intersection of the two selected elements is within this tolerance.
View Tolerance
This value, measured in degrees, is used when comparing angular values.
Dialog Decimal Precision
Specify the number of digits to the right of the decimal point. Change this value and tab 
to other fields to see the change in precision.
Note that this does not change the decimal precision in the NC dialog boxes. Click 
Options > NC Settings to change that decimal precision. Refer to Section 1.8.5: Options > 
NC Settings on page 161.
Click Units to choose between inch and metric measure.
No conversion of part geometry is carried out by SURFCAM. This effectively multiplies the 
tolerance values by a conversion factor to suit the tolerance values to the unit of measure 
that was chosen. The default unit can be set by using the SURFCAM Configuration Tools. 
Refer to Chapter 7: Configuration Tools, Units on page 370.
Click Axis to choose Mill Axis, Lathe Radius, or Lathe Diameter.
The default can be changed by editing the SURFCAM.INI file. This command is only 
available with the SURFCAM lathe option.
Click NC Settings to display the NC Settings dialog box that is used to control the display of 
dialog and warning boxes during toolpath creation and post processing. It also enables you 
to have control over the default values of NC parameters displayed during the preparation for 
creating toolpaths.
Note:
Changes you make in the NC Settings dialog box are saved when you exit 
SURFCAM.
Before performing an NC operation, such as 2 Axis Pocket, SURFCAM displays a dialog box 
containing the settings for the NC parameters used by the operation. When SURFCAM is 
shipped, these parameters have SURFCAM-determined default settings. The original default 
settings are contained in three— — initially identical— — INI files: SURFCAMDefault.ini, Default.ini 
and Current.ini. These files are saved in the C:\SURFCAM\Surf2000\NCDefault sub-
directory.
1.8.3
Options > Units
1.8.4
Options > Axis
1.8.5
Options > NC Settings
Add page number to pdf document - insert pages into PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide C# Users to Insert (Empty) PDF Page or Pages from a Supported File Format
add pages to an existing pdf; adding page to pdf
Add page number to pdf document - VB.NET PDF Page Insert Library: insert pages into PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use VB.NET APIs to Add a New Blank Page to PDF Document
adding page numbers in pdf; add and delete pages in pdf
162
SURFCAM Reference Manual,  Chapter 1 •  Menus and Dialog Boxes
Copyright © 2000 by Surfware, Inc. All Rights Reserved.
The original SURFCAM default settings are permanently saved in the SURFCAMDefault.ini 
file. This file is write-protected so that its contents will remain unchanged and it will always 
be available for use by a technician in the event that you request SURFCAM technical 
support.
Initially, the Default.ini file is a copy of SURFCAM’s default NC settings. It is expected that 
many users will want to modify this file to create their own set of default NC settings. If you 
do, you should write-protect it. To do this, right click the Default.ini file in the NCDefault sub-
directory. Select the Properties option from the menu that appears. Check the Read-Only 
attribute.
Current.ini is the file that SURFCAM reads, at start up, to get the default NC settings. When 
SURFCAM is shipped, this file contains the SURFCAM default NC settings.
In the following NC Settings dialog box, notice the three NC Dialog Options boxes that are 
checked. With these settings, the Current.ini file will be updated whenever you exit 
SURFCAM. The new contents of the Current.ini file will be the last NC settings in effect when 
you exit a SURFCAM session.
If you remove a check from one of these boxes, the related part of the Current.ini file will not 
be updated when you exit SURFCAM. The associated default NC settings will then remain 
the same as they were when you started the SURFCAM session in which you removed the 
check.
Figure 275: NC Settings dialog box
C# PDF insert text Library: insert text into PDF content in C#.net
Description: Add a char value at specified page position with pageIndex, The page index of the PDF page that will be 0
adding page numbers to pdf in reader; adding pages to a pdf
C# PDF File Split Library: Split, seperate PDF into multiple files
If your page number is set as 1, then the two output PDF files will contains the first page and the later three pages Add necessary references:
add page pdf; add contents page to pdf
Copyright © 2000 by Surfware, Inc. All Rights Reserved.
SURFCAM Reference Manual,  Chapter 1 •  Menus and Dialog Boxes
163
Don’t ask to accept or reject toolpaths. Keep All Toolpaths.
If not checked, the Keep Operation dialog box will be displayed each time a new 
toolpath is created (except when toolpaths are regenerated). You can then Accept or 
Reject the toolpath.
If checked, SURFCAM will keep all newly created toolpaths without displaying the Keep 
Operation dialog box.
The Keep Operation dialog box also has a Keep All Toolpaths check box which, if 
checked, puts a check in this check box.
During Posting, display a warning if file already exists.
During post processing several files are created. If a file with the same name already 
exists, you can be warned by a dialog box that asks “Do You Wish To Continue?” These 
existing files are usually temporary files from previous post processing operations. You 
will usually want to continue. Click this check box if you do want the warnings to be 
displayed.
Note:
Veteran SURFCAM users, note that this requires checking the box if you do 
want the warning displayed. Previous versions asked you to check the box if 
you did not want the warning displayed.
Close Operations Manager On Show Toolpath
Close Operations Manager On Backplot Toolpath
Close Operations Manager On Hide Toolpath
Check the corresponding box if you want the Operations Manager dialog box to close 
on the specified condition.
Dialog Decimal Precision
Specify the decimal precision displayed in NC dialog boxes. The default value is 6 
decimal places.
Save Settings As
Click this button to save the current NC settings on the Cut Control, Material and 
Options tabs as a customized default INI file.
You may find it helpful to have a special set of default NC settings for a particular type 
of NC project. For example, if there is a specialized 2 Axis job you do frequently, change 
the parameter settings on the 2 Axis Cut Control and Options tabs to meet the needs of 
that job. Then open the NC Settings dialog box and click the Save Settings As button to 
display the Save As dialog box. Save these NC settings as an INI file with a name of 
your choosing. Choose a new name for this kind of file. Do not save them as 
SURFCAMDefault, Default or Current since the files with these names have special 
uses. The default directory for these INI files is SURFCAM\Surf2000\NCDefault.
VB.NET PDF File Split Library: Split, seperate PDF into multiple
can split target multi-page PDF document file to one-page PDF files or PDF file to smaller PDF documents by every given number of pages Add necessary references
add a page to a pdf; add and delete pages in pdf online
C# PDF Text Search Library: search text inside PDF file in C#.net
Add necessary references: Description: Search specified string from all the PDF pages. eg: The first page is 0. 0
add and delete pages from pdf; add page to pdf online
164
SURFCAM Reference Manual,  Chapter 1 •  Menus and Dialog Boxes
Copyright © 2000 by Surfware, Inc. All Rights Reserved.
When you need these default settings, load them into SURFCAM using the Open 
Settings button.
Open Settings
Click this to display the Open dialog box. It will show the INI files in the NCDefault sub-
directory. When you click a file name and click Open, the NC settings in that file will be 
loaded into SURFCAM to become the new default NC settings. If you will need these 
settings in the next several SURFCAM sessions, save them— — using the Save Settings 
As button— — as the Current.ini file. Then they will be loaded automatically each time you 
start SURFCAM.
Enable Integrated Verification
Check this box to use integrated verification within SURFCAM. If this box is not 
checked, then the stand-alone version of SURFCAM Verify will be launched. Refer to 
the online Integrated Verify Document and to the online SURFCAM Verify Manual.
Figure 276: Save As dialog box for saving NC Settings
Figure 277: Open dialog box
C# PDF delete text Library: delete, remove text from PDF file in
Add necessary references: RasterEdge.Imaging.Basic.dll. matchString, The string wil be deleted from PDF file, -. 0
add a page to a pdf in reader; add pages to pdf acrobat
C# PDF Text Highlight Library: add, delete, update PDF text
200F); annot.EndPoint = new PointF(300F, 400F); // add annotation to The string wil be highlighted from PDF file, 0
adding page numbers to pdf; add page number to pdf online
Copyright © 2000 by Surfware, Inc. All Rights Reserved.
SURFCAM Reference Manual,  Chapter 1 •  Menus and Dialog Boxes
165
NC Dialog Options
Use last selected material as default at start-up
If checked, the last material loaded will be saved in the Current.ini file when you 
exit SURFCAM.
If not checked, the default material loaded is always the same and can be selected 
by clicking the Choose Material button.
If you click Choose Material, the Select Material dialog box will be displayed for 
you to make your selection. Refer to the SURFCAM Getting Started Manual, Chapter 3: 
Common NC Parameters, Section 3.2.2: The Material Library on page 76.
Use last selected tools as default at start-up
If checked, the last tool loaded will be saved in the Current.ini file when you exit 
SURFCAM.
If not checked, the default tools loaded are always the same and can be selected 
by clicking the Choose Tools button to display the Default Tools dialog box.
Figure 278: Select Material dialog box
Figure 279: SURFCAM Default Tools
C# Word - Split Word Document in C#.NET
If your page number is set as 1, then the two output Word files will contains the first page and the later three pages respectively. Add references:
add pages to pdf without acrobat; add page numbers to a pdf in preview
C# PowerPoint - Split PowerPoint Document in C#.NET
If your page number is set as 1, then the PowerPoint files will contains the first page and the Add necessary XDoc.PowerPoint DLL libraries into your created
add page number to pdf print; add page numbers to pdf in reader
166
SURFCAM Reference Manual,  Chapter 1 •  Menus and Dialog Boxes
Copyright © 2000 by Surfware, Inc. All Rights Reserved.
There are separate default tools for US (Inch) Tools and Metric (MM) Tools. There 
are seven categories of tools for which defaults can be set. To change the default 
tool for a category, click its button. This will display the Select Tool dialog box for 
that category of tool. Refer to the SURFCAM Getting Started Manual, Chapter 3: Common 
NC Parameters, Section 3.2.1.1: Select Tool on page 70 for a description of how to use the 
Select Tool dialog box.
Save cut control information at SURFCAM exit
If checked, the last entries on the Cut Control, Material and Options tabs will be 
saved in the Current.ini file when you exit SURFCAM.
If not checked, the default NC settings will stay the same. When you exit the 
SURFCAM session in which you remove the check from this box, the Current.ini 
will not be updated. Therefore, the default NC settings for the next SURFCAM 
session will be the same as the ones for the previous session.
Calculate Initial Value For Minimum Z
If checked, the initial value for the Minimum Z parameter on the 3 Axis, 4 Axis and 
5 Axis Cut Control tabs will be calculated from the geometry selected. If not 
checked, the initial value for Minimum Z will be blank.
Program Number is Alphanumeric Name
If checked, you can add a program name instead of a number in the Tool 
Information dialog box. This should be used only when you choose APT-CL in the 
Post List box of the NC Operations Manager. The output file will then show the 
PARTNO/Alphanumeric name.
Enter password for upgrading functionality. Refer to the SURFCAM Getting Started Manual, 
Chapter 1: System Basics, Section 1.4: Password on page 7.
Surface Intersect and Fillet Tolerance
SURFCAM uses this tolerance when creating splines and surface fillets. It defines the 
chordal accuracy of the curves when created.
1.8.6
Options > Password
1.8.7
Options > Create
Figure 280: Create Options dialog box
Copyright © 2000 by Surfware, Inc. All Rights Reserved.
SURFCAM Reference Manual,  Chapter 1 •  Menus and Dialog Boxes
167
Surface Fillet Maximum Evaluation Step
SURFCAM uses this tolerance when creating splines and surface fillets. It defines the 
maximum distance between each evaluation pass.
Create Rationals
SURFCAM uses this option when creating splines and surfaces.
If Checked
This will force EXACT representation of the elements used for construction. It will 
increase the size of the database and is recommended when perfect accuracy is 
a must.
If Not Checked
This will provide an approximate representation of the elements used for 
construction. It will decrease the size of the database and is recommended when 
general tolerances are required.
The surface will be built within the user tolerance of the exact theoretical surface. 
(Enter the User Tolerance value in the Tolerance Options dialog box that appears 
when you click Tolerances on the Options menu.) The default is .00005 inches or 
.001 mm. Refer to Section 1.8.3: Options > Units on page 161.
Click Options > Snap & Grid to display the Snap & Grid Options dialog box.
1.8.8
Options > Snap & Grid
Figure 281: Snap & Grid Options dialog box
168
SURFCAM Reference Manual,  Chapter 1 •  Menus and Dialog Boxes
Copyright © 2000 by Surfware, Inc. All Rights Reserved.
Refer to the SURFCAM Getting Started Manual, Chapter 1: System Basics, Points on a User Defined 
Grid on page 36.
Status
Click Status to see a pop-up window showing the amount of memory space that has been 
used by SURFCAM’s Database and Display list, as well as the amount of space free and the 
maximum amount available.
The database is where all elements and views are recorded. It is a double precision (16 digit 
accuracy) database. The display list is a single precision copy of the elements in the 
database that are used for SURFCAM to draw quickly on the screen. Because the display 
list is single precision, its maximum size is usually configured to be about half the size of the 
database.
The size of the database and display list can be changed by modifying the DataRAM and 
DisplayRAM parameters in the SURFCAM.INI file. Refer to Chapter 7: Configuration Tools, 
Memory allocation settings on page 369.
About SURFCAM
Click About SURFCAM to see a window showing:
1. The current version
2. Copyright information
3. The licensee
4. The SIM serial number
5. The Maintenance expiration date
1.9
H
ELP
M
ENU
Contents
Click Contents to display the main SURFCAM help file and its table 
of contents.
For an in-depth discussion of the help file refer to the SURFCAM 
Getting Started Manual, Chapter 7: Tutorial, Section 7.1: Using SURFCAM 
Help on page 217.
Figure 282: 
Help menu
Figure 283: Statistics pop-up window
Copyright © 2000 by Surfware, Inc. All Rights Reserved.
SURFCAM Reference Manual,  Chapter 1 •  Menus and Dialog Boxes
169
6. A list of the products that you have purchased in addition to the basic 
product— not all of the options that you have available
The following options are currently automatic with any installation of 
SURFCAM and will not be listed:
A. Lathe for SURFCAM 3 Axis and better
B. 5 Axis Trim for SURFCAM 3 Axis Plus and better
C. Parasolids translator.
7. A button that you can click to access the Surfware web site: www.surfware.com.
170
SURFCAM Reference Manual,  Chapter 1 •  Menus and Dialog Boxes
Copyright © 2000 by Surfware, Inc. All Rights Reserved.
Documents you may be interested
Documents you may be interested