Design Rules Reference 
Routing Topology 
Description 
The topology of a net is the arrangement or pattern of the pin-to-pin connections. By default, pin-to-pin connections of each net 
are arranged to give the shortest overall connection length. A topology is applied to a net for a variety of reasons; for high speed 
designs where signal reflections must be minimized the net is arranged with a daisy chain topology; for ground nets a star 
topology could be applied to ensure that all tracks come back to a common point. 
Constraints 
Topology
 defines the topology to be used for the net(s) targeted by the scope (full query) of the rule. The following 
topologies can be applied: 
Shortest 
This topology connects all nodes in the net to give the shortest overall connection length. 
Horizontal 
This topology connects all the nodes together, preferring horizontal shortness to vertical shortness by a 
factor of 5:1. Use this method to force routing in the horizontal direction. 
Vertical 
This topology connects all the nodes together, preferring vertical shortness to horizontal shortness by a 
factor of 5:1. Use this method to force routing in the vertical direction. 
Daisy-Simple 
This topology chains all the nodes together, one after the other. The order they are chained is calculated 
to give the shortest overall length. If a source and terminator pad are specified, then all other pads are 
chained between them to give the shortest possible length. Edit a pad to set it to be a source or 
terminator. If multiple sources (or terminators) are specified, they are chained together at each end. 
Daisy-Mid Driven 
This topology places the source node(s) in the center of the daisy chain, divides the loads equally and 
chains them off either side of the source(s). Two terminators are required, one for each end. Multiple 
source nodes are chained together in the center. If there are not exactly two terminators the Daisy-
Simple topology is used. 
Daisy-Balanced 
This topology divides all the loads into equal chains, the total number of chains equal to the number of 
terminators. These chains then connect to the source in a star pattern. Multiple source nodes are 
chained together. 
Starburst 
This topology connects each node directly to the source node. If terminators are present, they are 
connected after each load node. Multiple source nodes are chained together, as in the Daisy-Balanced 
topology. 
Rule Classification 
Unary 
How Duplicate Rule Contentions are Resolved 
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first 
one whose scope expression(s) match the object(s) being checked. 
Rule Application 
During autorouting. 
Notes 
When using the Autorouter, routing completion time may be longer when using topologies other than Shortest. 
TR0116 (v1.8) May 20, 2008 
31
Cut pages from pdf file - remove PDF pages in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Provides Users with Mature Document Manipulating Function for Deleting PDF Pages
delete blank page from pdf; delete page from pdf reader
Cut pages from pdf file - VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Visual Basic Sample Codes to Delete PDF Document Page in .NET
delete pages from pdf file online; delete pdf pages ipad
Design Rules Reference 
Routing Priority 
Description 
Assigns a routing priority to the net(s) targeted by the rule. The Autorouter uses the assigned priority value to gauge the routing 
importance of each net in the design and hence determine which nets should be routed first. 
Constraints 
Routing Priority
 the priority value assigned to the net(s) targeted by the scope (full query) of the rule. Enter a value 
between 0 and 100, whereby the higher the number assigned, the greater the priority when routing. 
(Default  = 0). 
Rule Classification 
Unary 
How Duplicate Rule Contentions are Resolved 
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first 
one whose scope expression(s) match the object(s) being checked. 
Rule Application 
During autorouting. 
32 
TR0116 (v1.8) May 20, 2008 
C# PDF Page Extract Library: copy, paste, cut PDF pages in C#.net
PDF Pages in C#.NET. Easy to Use C# Code to Extract PDF Pages, Copy Pages from One PDF File and Paste into Others in C#.NET Program.
delete a page from a pdf file; add and delete pages in pdf
VB.NET PDF Page Extract Library: copy, paste, cut PDF pages in vb.
VB.NET PDF - PDF File Pages Extraction Guide. Help to extract single or multiple pages from adobe PDF file and save into a new PDF file.
delete pages in pdf online; delete a page from a pdf
Design Rules Reference 
Routing Layers 
Description 
Specifies which layers are allowed to be used for routing when using the Autorouter. 
Constraints 
Each of the signal layers currently defined for the design - as defined by the layer stackup - are listed. By default, the Allow 
Routing constraint for each layer will be enabled. 
Rule Classification 
Unary 
How Duplicate Rule Contentions are Resolved 
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first 
one whose scope expression(s) match the object(s) being checked. 
Rule Application 
During autorouting. 
Notes 
The routing direction for each enabled signal layer in the design is defined as part of the Situs Autorouter setup. Directions are 
specified in the Layer Directions dialog, which in turn is accessed by clicking the Edit Layer Directions button in the Situs 
Routing Strategies dialog. 
Note: Setting the routing direction for a layer to ANY can affect performance when autorouting. More efficient use of board area 
may be achieved by choosing a specific routing direction. 
TR0116 (v1.8) May 20, 2008 
33
C# PDF copy, paste image Library: copy, paste, cut PDF images in
PDF image cutting is similar to image deleting. So, in C# demo code below, we will explain how to cut image from PDF file page by using image deleting API.
delete pages from pdf in preview; delete blank pages from pdf file
VB.NET PDF copy, paste image library: copy, paste, cut PDF images
PDF image cutting is similar to image deleting. So, below example explains how to cut image from PDF file page by using image deleting API.
acrobat remove pages from pdf; add and remove pages from a pdf
Design Rules Reference 
Routing Corners 
Description 
Specifies the corner style to be used during autorouting. 
Constraints 
Style
 specifies which routing corner style to use. The following three styles are available: 
90 Degrees 
45 Degrees (default) 
Rounded 
Setback
 these two fields allow you to define a minimum and maximum value for the setback, when using the 45° 
and Rounded corner styles. The setback is the distance from the 'true' corner location (that which would 
exist if using the 90° style) to the point at which the Autorouter should begin its chamfering or rounding, 
in effect, controlling miter size or corner radius. (Default  = 100mil for both fields). 
Rule Classification 
Unary 
How Duplicate Rule Contentions are Resolved 
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first 
one whose scope expression(s) match the object(s) being checked. 
Rule Application 
This rule is intended for use by third party Autorouters that implement 45°routing as a post process. It is not followed by the 
Situs Autorouter, which implements 45° routing as a native process. 
34 
TR0116 (v1.8) May 20, 2008 
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
Image: Copy, Paste, Cut Image in Page. Link: Edit Redact Text Content. Redact Images. Redact Pages. Annotation & Text. Add Text Box. Drawing Markups. PDF Print. Work
delete pages on pdf; delete page in pdf
C# PDF Page Insert Library: insert pages into PDF file in C#.net
Add and Insert Blank Pages to PDF File in C#.NET. This C# demo explains how to insert empty pages to a specific location of current PDF file.
delete page pdf acrobat reader; delete page in pdf preview
Design Rules Reference 
Routing Via Style 
Description 
Specifies the routing via diameter and hole size. 
Constraints 
Via Diameter
 specifies constraint range values to be adhered to with respect to the diameters of vias placed when 
routing the board. The following individual values are definable: 
Minimum - the minimum permissible value for the via diameter. (Default  = 50mil) 
Maximum - the maximum permissible value for the via diameter. (Default  = 50mil) 
Preferred - the preferred value for the via diameter. (Default  = 50mil). 
Via Hole Size
 specifies constraint range values to be adhered to with respect to the hole sizes of vias placed when 
routing the board. The following individual values are definable: 
Minimum - the minimum permissible value for the via hole size. (Default  = 28mil) 
Maximum - the maximum permissible value for the via hole size. (Default  = 28mil) 
Preferred - the preferred value for the via hole size. (Default  =  28mil). 
Rule Classification 
Unary 
How Duplicate Rule Contentions are Resolved 
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first 
one whose scope expression(s) match the object(s) being checked. 
Rule Application 
The Preferred via attributes are used by the Autorouter. 
The Minimum and Maximum via attributes determine the range of permissible values that can be used during interactive 
routing, when you press the * shortcut key to toggle routing signal layers, or when you press the / shortcut key to connect to a 
plane layer. Press the TAB key while routing to change a value within its defined range. If a value is entered outside of its 
range, a dialog will appear alerting you to this fact. You will be prompted to either continue, in which case the value will 
automatically be clipped, or cancel and change the value yourself. 
Notes 
In order to control the size of blind and buried vias, individual rules can be set up targeting the different layer pairs. For example, 
to control the via size for blind vias between the top layer and mid layer 1, the following scope (Full Query) can be used: 
(StartLayer = 'TopLayer') and (StopLayer = 'MidLayer1')
to control the via size for buried vias between mid layer 2 and mid layer 3, the following scope would be used: 
(StartLayer = 'MidLayer2') and (StopLayer = 'MidLayer3')
Alternatively, instead of creating individual rules, you can expand the one rule query using ORs: 
((StartLayer = 'TopLayer') and (StopLayer = 'MidLayer1')) or
((StartLayer = ' MidLayer2') and (StopLayer = 'MidLayer3'))
TR0116 (v1.8) May 20, 2008 
35
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Moreover, you may use the following VB.NET demo code to insert multiple pages of a PDF file to a PDFDocument object at user-defined position.
delete pages pdf files; delete pages from pdf online
C# PDF File Split Library: Split, seperate PDF into multiple files
note, PDF file will be divided from the previous page of your defined page number which starts from 0. For example, your original PDF file contains 4 pages.
cut pages out of pdf online; delete blank pages in pdf online
Design Rules Reference 
Fanout Control 
Description 
Specifies fanout options to be used when fanning out the pads of surface mount components in the design that connect to 
signal and/or power plane nets. Fanout essentially turns an SMT pad into a thru hole pad, from a routing point of view, by 
adding a via and connecting track. This greatly increases the probability of successfully routing the board as a signal is made 
available to all routing layers instead of just the top or bottom layer. This is particularly needed in high-density designs where 
routing space is very tight. 
Constraints 
Fanout Options 
Fanout Style
 specifies how the fanout vias are placed in relation to the SMT component. The following options 
are available: 
Auto (default) - chooses the style most appropriate for the component technology and in order 
to give optimal routing space results 
Inline Rows - fanout vias are placed within two aligned rows 
Staggered Rows - fanout vias are placed within two staggered rows 
BGA - fanout occurs in accordance with the specified BGA Options 
Under Pads - fanout vias are placed directly under SMT component pads. 
Fanout Direction
 specifies the direction to use for the fanout. The following options are available: 
Disable - do not allow fanout with respect to the SMT components targeted by the rule 
In Only - fanout in an inward direction only. All fanout vias and connecting track will be placed 
within the component's bounding rectangle 
Out Only - fanout in an outward direction only. All fanout vias and connecting track will be 
placed outside of the component's bounding rectangle 
In Then Out - Fanout all component pads in an inward direction to begin with. All pads that 
cannot be fanned out in this direction should be fanned out in an outward direction (if possible) 
Out Then In - Fanout all component pads in an outward direction to begin with. All pads that 
cannot be fanned out in this direction should be fanned out in an inward direction (if possible) 
Alternating In and Out (default) - Fanout all component pads (where possible) in an alternating 
fashion, first inward then outward. 
BGA Options 
Direction From Pad
 specifies the direction to use for the fanout. When a BGA component is fanned out, its pads are 
sectioned into quadrants, with fanout applied to the pads in each quadrant simulataneously. The 
following options are available: 
Away From Center (default) - fanout for pads in each quadrant is applied following a 45° angle 
away from the component's center 
North-East - All pads, in each quadrant, are fanned out in a North-Easterly direction (45° anti-
clockwise from the horizontal) 
South-East - All pads, in each quadrant, are fanned out in a South-Easterly direction (45° 
clockwise from the horizontal) 
South-West - All pads, in each quadrant, are fanned out in a South-Westerly direction (135° 
clockwise from the horizontal) 
North-West - All pads, in each quadrant, are fanned out in a North-Westerly direction (135° 
anti-clockwise from the horizontal) 
Towards Center - fanout for pads in each quadrant is applied following a 45° angle toward the 
component's center. In most cases, uniformity of direction will not be possible due to required 
fanout space already taken by another pads' fanout via. In these cases, fanout will occur in the 
next available direction (North-East, South-East, South-West, North-West). 
36 
TR0116 (v1.8) May 20, 2008 
Design Rules Reference 
Via Placement Mode
 specifies how the fanout vias are placed in relation to the pads of the BGA component. The 
following options are available: 
Close To Pad (Follow Rules) - fanout vias will be placed as close to their corresponding SMT 
component pads as possible, without violating defined clearance rules 
Centered Between Pads (default) - fanout vias will be centered between the SMT component 
pads. 
Rule Classification 
Unary 
How Duplicate Rule Contentions are Resolved 
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first 
one whose scope expression(s) match the object(s) being checked. 
Rule Application 
During interactive routing and autorouting. 
Notes 
The following default Fanout Control design rules are automatically created, covering the typical component package types 
available (listed in descending order of priority): 
Fanout_BGA - with a query of IsBGA 
Fanout_LCC - with a query of IsLCC 
Fanout_SOIC - with a query of IsSOIC 
Fanout_Small - with a query of (CompPinCount < 5) 
Fanout_Default - with a query of All 
These rules can be edited or others defined, in accordance with your individual design requirements. 
The style used for the fanout vias will follow the applicable Routing Via Style design rule(s). Additional track laid down as part of 
the fanout process from pad to via will follow the applicable Routing Width design rule(s). 
TR0116 (v1.8) May 20, 2008 
37
Design Rules Reference 
Differential Pairs Routing 
Description 
Specifies the maximum, minimum distances between tracks in a differential pair routing and the maximum distance that the pair 
is allowably uncoupled (ie: less than minumum gap or more than maximum gap). 
Constraints 
Min Gap
 the value for the minimum permissible distance between the tracks in the differential pair. 
(Default  = 10mil). 
Max Gap
 the value for the maximum permissible distance between the tracks in the differential pair. 
(Default  = 10mil). 
Preferred Gap
 the value for the preferred distance between the tracks in the differential pair. (Default  = 
10mil). 
Max Uncoupled Length
 the value for the maximum permissible distance in the differential pair where the tracks are 
considered uncoupled. (Default  = 500mil). 
Rule Classification 
Unary 
Rule Application 
Online DRC and Batch DRC. 
Notes 
DIfferential pair routing should be performed independently of the Autorouter. 
38 
TR0116 (v1.8) May 20, 2008 
Design Rules Reference 
SMT Rules 
SMD to Corner 
Description 
Specifies the minimum distance from the edge of the surface mount pad to the first routing corner. 
Constraints 
Distance
 the value for the minimum permissible distance from the SMD pad edge to the start of the first routing 
corner. (Default  = 0mil). 
Rule Classification 
Unary 
How Duplicate Rule Contentions are Resolved 
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first 
one whose scope expression(s) match the object(s) being checked. 
Rule Application 
Online DRC and Batch DRC. 
SMD to Plane 
Description 
Specifies the maximum routing length from the center of the surface mount pad to the center of the pad/via connecting to a 
power plane. 
Constraints 
Distance
 the value for the maximum permissible distance from SMD pad to pad/via connecting to the power plane. 
(Default  = 0mil). 
Rule Classification 
Unary 
How Duplicate Rule Contentions are Resolved 
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first 
one whose scope expression(s) match the object(s) being checked. 
Rule Application 
Online DRC and Batch DRC. 
TR0116 (v1.8) May 20, 2008 
39
Design Rules Reference 
SMD Neck-Down 
Description 
Specifies the maximum ratio of the track width to the SMD pad width, expressed as a percentage. 
Constraints 
Neck-Down
 the percentage value for the maximum permissible ratio of track width to SMD pad width. Entering a larger 
value will allow for the use of greater width track. (Default  = 50%). 
Rule Classification 
Unary 
How Duplicate Rule Contentions are Resolved 
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first 
one whose scope expression(s) match the object(s) being checked. 
Rule Application 
Online DRC and Batch DRC. 