1.108
PART 1
In this type of protection, the power (usually in the primary side of the converter trans-
former) is constantly monitored. If this power exceeds a predetermined limit, then the 
power supply shuts down or goes into a power-limited mode of operation, In a multiple-
output unit, the power would be the sum of the individual outputs.
The power limiting action would normally take one of five forms: 
A. Primary overpower limiting 
B. Delayed overpower shutdown 
C. Pulse-by-pulse overpower/overcurrent limiting 
D. Constant-power limiting 
E. Foldback (reentrant) overpower limiting 
13.4 TYPE 1, FORM A, PRIMARY OVERPOWER 
LIMITING 
In this form of power limiting, the primary power is constantly monitored. If the load tries 
to exceed a defined maximum, the input power is limited to prevent any further increase.
Usually, the shape of the output current shutdown characteristic is poorly defined when 
primary power limiting is used on its own. However, because of its low cost, primary power 
limiting has become generally accepted in lower-power, low-cost units (particularly in 
multi-output flyback power supplies).
It should be noted that when a load fault develops in a multiple-output system, a line that 
has been designed to provide only a small proportion of the total power may be expected to 
support the full output power if it is the only line that is overloaded.
Often these simple primary power limiting systems give full protection only for short-
circuit conditions. An area of vulnerability can exist when partial overloads are applied, par-
ticularly when these are applied to a single output of a multiple-output system. Under these 
conditions, partial overloads may result in eventual failure of the power supply if they persist 
for long periods; hence it is better to remove this stress as soon as possible by turning the sup-
ply off. For this reason the delayed overpower trip technique Form B is recommended. 
13.5 TYPE 1, FORM B, DELAYED OVERPOWER 
SHUTDOWN PROTECTION
One of the most effective overload protection methods for low-power, low-cost supplies 
is the delayed overpower shutdown technique. This operates in such a way that if the 
load power exceeds a predetermined maximum for a duration beyond a short defined safe 
period, the power supply will turn off, and an input power off-on cycle will be required to 
reset it to normal operation.
Not only does this technique give the maximum protection to both power supply and 
load, but it is also the most cost-effective for small units. Although this method seems gen-
erally unpopular with most users, it should not be neglected, as it makes good sense to turn 
the power supply off when overloads occur. A persistent power overload usually indicates 
a fault within the equipment, and the shutdown method will provide full protection to both 
load and supply.
Unfortunately, many specifications eliminate the possibility of using a simple trip type 
of protection by demanding automatic recovery from an overload condition. It is possible 
Delete pdf pages reader - remove PDF pages in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Provides Users with Mature Document Manipulating Function for Deleting PDF Pages
cut pages out of pdf file; delete pages on pdf
Delete pdf pages reader - VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Visual Basic Sample Codes to Delete PDF Document Page in .NET
delete blank page in pdf; cut pages from pdf file
13. OVERLOAD PROTECTION
1.109
that the user has specified automatic recovery because of previous bad experience (e.g., 
“lockout” or nuisance shutdowns) with reentrant or trip-type systems that did not have a 
sufficient current margin or a delayed shutdown. The power supply designer should ques-
tion such specifications. Modern switchmode supplies are capable of delivering currents 
well in excess of their continuous rated value for short periods of time, and with delayed 
shutdown they will not “lock out” even if a shutdown system has been used.
In the delayed trip system, short transient current requirements are accommodated, and 
the supply will shut down only if the stress exceeds safe amplitudes for long periods. 
Short-lived transient currents can be provided without jeopardizing the reliability of the 
power supply or having a very significant impact on the cost of the unit. It is the long-term 
continuous current requirements that affect cost and size. There will usually be some deg-
radation in the performance of the unit during the high-current transient. Specified voltage 
tolerances and ripple values may be exceeded. Typical examples of loads subject to large 
but short transients would be floppy disks and solenoid drivers.
13.6 TYPE 1, FORM C, PULSE-BY-PULSE 
OVERPOWER/CURRENT LIMITING 
This is a particularly useful protection technique that will often be used in addition to any 
secondary current limit protection.
The input current in the primary switching devices is monitored on a real-time basis. 
If the current exceeds a defined limit, the “on” pulse is terminated. With discontinuous 
flyback units, the peak primary current defines the power, and hence this type of protection 
becomes a true power limit for such units.
With the forward converter, the input power is a function of input current and volt-
age; hence this type of protection provides a primary current limit in this type of circuit. 
However, this technique still provides a useful measure of power limit protection so long 
as the input voltage is constant.
A major advantage of the fast pulse-by-pulse current limit is that it provides protection 
to the primary switching devices under unusual transient stress, for example, transformer 
staircase-saturation effects.
Current-mode control provides this primary pulse-by-pulse current limiting as a normal 
function of the control technique, one of its major advantages. (See Part 3, Chap. 10.)
13.7 TYPE 1, FORM D, CONSTANT POWER 
LIMITING 
Constant input power limiting will protect the primary circuit by limiting the maximum 
transmitted power. However, in the case of the flyback converter, this technique does 
little to protect the secondary output components. For example, consider a discontinuous 
flyback converter for which the peak primary current has been limited, giving limited 
transmitted power.
When the load exceeds this limit (load resistance reducing), the output voltage begins 
to fall. However, since it is the input (and hence output) volt-ampere product that has been 
defined, as the output voltage starts to fall, the output current will increase. (On short circuit 
the secondary current will be large and the total power must be dissipated within the power 
supply.) Hence this form of power limiting is normally used to supplement some other form 
of limiting, such as secondary current limits.
C# PDF Page Insert Library: insert pages into PDF file in C#.net
how to merge PDF document files by C# code, how to rotate PDF document page, how to delete PDF page using C# .NET, how to reorganize PDF document pages and how
delete page from pdf preview; delete pages of pdf reader
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
VB.NET Page: Insert PDF pages; VB.NET Page: Delete PDF pages; VB.NET Annotate: PDF Markup & Drawing. XDoc.Word for XImage.OCR for C#; XImage.Barcode Reader for C#
delete pages from pdf online; delete pages from pdf reader
1.110
PART 1
13.8 TYPE 1, FORM E, FOLDBACK (REENTRANT) 
OVERPOWER LIMITING
This technique is an extension of form d in which a circuit monitors primary current and 
secondary voltage, and reduces the power as the output voltage falls. By this means, the 
output current can be reduced as the load resistance falls, preventing excessive stress on 
secondary components. It has the possible disadvantage of “lockout” with nonlinear loads. 
(See Part 1, Chap. 14.)
13.9 TYPE 2, OUTPUT CONSTANT CURRENT 
LIMITING 
Power supplies and loads can be very effectively protected by limiting the maximum 
current allowed to flow under fault conditions. Two types of current limiting are in 
common use, constant current and foldback current limiting. The first type, constant 
current limiting, as the name implies, limits the output current to a constant value if 
the load current tries to exceed a defined maximum. A typical characteristic is shown 
in Fig. 1.13.1.
FIG. 1.13.1 Typical V/I characteristics of a “constant-current-limited” power 
supply, showing linear (resistive) load lines.
From this diagram, it can be seen that as the load current increases from a low value (R1,
high resistance) to its maximum normal current value (R3, median resistance), the current 
will increase at constant voltage along the characteristic P1– P2–P3, which are all currents 
and voltages within the normal working range of the supply.
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Page: Insert PDF Pages. |. Home ›› XDoc.PDF ›› VB.NET PDF: Insert PDF Page. Add and Insert Multiple PDF Pages to PDF Document Using VB.
delete a page from a pdf acrobat; delete pages from a pdf
VB.NET PDF Page Extract Library: copy, paste, cut PDF pages in vb.
Page: Extract, Copy, Paste PDF Pages. |. Home ›› XDoc.PDF ›› VB.NET PDF: Copy and Paste PDF Page. VB.NET PDF - PDF File Pages Extraction Guide.
delete page in pdf reader; delete pdf pages ipad
13. OVERLOAD PROTECTION
1.111
When the limiting current is reached at P3, the current is not allowed to increase any fur-
ther. Hence, as the load resistance continues to fall toward zero, the current remains nearly 
constant and the voltage must fall toward zero, characteristic P3–P4. The current-limited 
area is often not well specified, and the working point will be somewhere in the range P4
to P4 at a load resistance of R4.
Since the current limit is normally provided as a protection mechanism for the power 
supply, the characteristic in the current-limited range may not be well defined. The limit 
current range, P4–P4, may change by as much as 20% as the load resistance is taken toward 
zero (a short circuit). If a well-defined constant current range is required, a “constant cur-
rent power supply” should be specified (see Part 2, Chap. 22).
Current limiting will normally be applied to the secondary of the power converter. In a 
multiple-output system, each output will have its own individual current limiting. The cur-
rent limits will normally be set at some independent maximum value for each output line, 
irrespective of the power rating of the supply. If all outputs are fully loaded simultaneously, 
the total loading may exceed the maximum power rating of the supply. Hence, a primary 
power limit will often be provided to supplement the secondary current limits. Under fault 
conditions, both primary and secondary components are fully protected, and the loads will 
all have limited currents within their design maximums at all times. 
This method of current limiting undoubtedly gives the user and the supply the best pro-
tection. Not only are currents limited to values consistent with the design ratings for each 
line, but minimum problems occur with nonlinear or cross-connected loads. The lockout 
difficulties often associated with foldback limit systems are completely eliminated. Also,
automatic recovery is provided when an overload is removed. Moreover, such units may 
be operated in parallel, the only proviso being that the current limit should be set to some 
value within the continuous working range. This method of protection is recommended for 
professional-grade supplies, although it is more expensive. 
13.10 TYPE 3, OVERLOAD PROTECTION BY 
FUSES, CURRENT LIMITING, OR TRIP DEVICES 
Type 3 employs mechanical or electromechanical current protection devices, and these will 
normally require operator intervention to be reset. In modern electronic switchmode power 
supplies, this type of protection is normally used only as a backup to the self-recovery 
electronic protection methods. Hence it is a “last ditch” protection method. It is required 
to operate only if the normal electronic protection fails. In some cases a combination of 
methods may be used.
Included in Type 3 protection methods are fuses, fusible links, fusible resistors, resis-
tors, thermal switches, circuit breakers, PTC thermistors, and so on. These devices all have 
their place, and should be considered for specific applications.
Where fuses are used, it should be remembered that currents well in excess of the 
fuse rating can be taken through the fuse for considerable periods before fuse clearance. 
Also, fuses running at or near their rated value have a limited life and should be periodi-
cally replaced. Remember also that fuses dissipate power and have considerable resistance; 
when used in output circuits, they will often have resistance values well above the normal 
output resistance of the supply.
However, fuses do have good applications. For example, when a small amount of logic 
current (say a few hundred milliamperes) is required from a high-current output, this may 
be a good application for a fuse. Clearly, it would not be sensible to design a printed circuit 
board and connections to withstand the high current that would flow on this low-power 
logic board in the event of a short circuit, and a fuse could be used in this application, 
C# PDF Page Extract Library: copy, paste, cut PDF pages in C#.net
C#.NET PDF Library - Copy and Paste PDF Pages in C#.NET. Easy to C#.NET Sample Code: Copy and Paste PDF Pages Using C#.NET. C# programming
delete page in pdf file; delete page pdf acrobat reader
C# PDF Page Rotate Library: rotate PDF page permanently in C#.net
batch changing PDF page orientation without other PDF reader control. NET, add new PDF page, delete certain PDF page, reorder existing PDF pages and split
delete pages out of a pdf; cut pages from pdf preview
1.112
PART 1
providing protection without excessive voltage drop. More sophisticated protection tech-
niques may not be justified in this situation.
Fuses or circuit breakers will also be used to back up the electronic overload protection, 
such as SCR “crowbar” protection in linear power supplies, in many applications. In such 
applications the performance of the fuse is critical, and the fuse type and rating must be 
carefully considered. (See Part 1, Chap. 5.)
13.11 PROBLEMS 
1. What is the normal overload protection criterion for professional-grade power supplies? 
2. Give four types of overload protection in common use. 
3. Give the main advantages and limitations of each of the four types of protection. 
C# Imaging - Scan Barcode Image in C#.NET
RasterEdge Barcode Reader DLL add-in enables developers to add barcode image recognition & barcode types, such as Code 128, EAN-13, QR Code, PDF-417, etc.
delete a page from a pdf online; delete pages on pdf file
VB.NET PDF delete text library: delete, remove text from PDF file
Visual Studio .NET application. Delete text from PDF file in preview without adobe PDF reader component installed. Able to pull text
delete a page from a pdf in preview; copy pages from pdf to new pdf
1.113
FOLDBACK (REENTRANT) 
OUTPUT CURRENT LIMITING 
14.1 INTRODUCTION 
Foldback current limiting, sometimes referred to as reentrant current limiting, is simi-
lar to constant current limiting, except that as the voltage is reduced as a result of the 
load resistance moving toward zero, the current is also induced to fall. However, this 
aparently minor change in the characteristic has such a major impact on the performance 
that it justifies special attention. To introduce the principle, a linear power supply will 
be considered.
In linear power supplies, the purpose of foldback current limiting is to prevent damage 
to the power supply under fault conditions. With foldback limiting, the current is reduced 
under overload conditions, reducing the power stress on the linear regulator transistors. 
Because of the high dissipation that would otherwise occur, some form of foldback current 
limiting is almost universal in linear power supplies. 
14.2 FOLDBACK PRINCIPLE 
Figure 1.14.1 shows a typical reentrant characteristic, as would be developed measured at 
the output terminals of a foldback-limited power supply.
A purely resistive load will develop a straight load line (for example, the 5-7 load line 
shown in Fig. 1.14.1). A resistive load line has its point of origin at zero, and the current is 
proportional to voltage.
As a resistive load changes, the straight line (which will start vertically at zero load—
i.e., infinite resistance) will swing clockwise around the origin to become horizontal for a 
short circuit (zero resistance). It should be noted that a straight resistive load line can cross 
the reentrant characteristic of the power supply at only one point, for example, point P1 
in Fig. 1.14.1 or 1.14.3. Consequently, “lockout” cannot occur with linear resistive loads, 
even if the shutdown characteristic is reentrant.
In the example shown in Fig. 1.14.1, as the load current increases from zero, the 
voltage initially remains constant at the stabilized 5-V output. However, when the maxi-
mum limiting current I
max
has been reached at P2, any further attempt to increase the 
load (reduction of load resistance) results in a reduction in both output voltage and cur-
rent. Hence, under short-circuit conditions, only a small current I
sc
flows in the output 
terminals.
CHAPTER 14 
1.113
1.114
PART 1
14.3 FOLDBACK CIRCUIT PRINCIPLES 
AS APPLIED TO A LINEAR SUPPLY
In the simple linear regulator shown in Fig. 1.14.2a, a typical foldback current limit circuit 
is shown (in dashed outline). The output parameters are shown in Fig. 1.14.1, and the regu-
lator dissipation in Fig. 1.14.2b.
This circuit operates as follows: When the main series regulator transistor Q1 is 
conducting, a voltage proportional to the output current I
load
is developed across the 
current limit resistor R1. This voltage, together with the base-emitter voltage of Q1, 
is applied to the base of the current limit transistor Q2 through the divider network 
R2, R3.
Since the base-emitter voltage drop V
be
of Q1 will be approximately the same as that 
of Q2 at the point of current limit, the voltage across R2 is the same as that across R1 but 
is level-shifted by +V
be
. At the point of transition into current limit, the current flow in 
R2 is the same as that in R3 (neglecting small base currents), and Q2 is on the threshold 
of conduction.
Any further increase in the load current at this point will increase the voltage across R1
and hence across R2, and Q2 will be progressively turned on. As Q2 conducts, it diverts 
the drive current from Q3 away from Q1 into the output load, Q1 starts to turn off, and the 
output voltage falls. Note: Q3 is a constant-current source.
As the output voltage falls, the voltage across R3 decreases and the current in R3 also 
decreases, and more current is diverted into the base of Q2. Hence, the current required in 
R1 to maintain the conduction state of Q2 is also decreased.
Consequently, as the load resistance is reduced, the output voltage and current fall, and 
the current limit point decreases toward a minimum when the output voltage is zero (output 
short circuit). At short circuit, the current in R1 is very small, and the voltage across R1
and R2 will also be small. 
FIG. 1.14.1 Current overload reentrant shutdown characteristic of fold-
back current-limited supply.
14. FOLDBACK (REENTRANT) OUTPUT CURRENT LIMITING
1.115
The short-circuit current is not well defined, as the base current of Q2 depends on its 
current gain, which will vary between devices; also, the V
be
of Q1 and Q2 are temperature-
dependent. These variations can be minimized by mounting Q2 on the same heat sink as 
Q1 and by using relatively low values for R1 and R2 (typically R1 would be of the order 
of 100 7 in the example shown).
In Fig. 1.14.1, it should be noted that a current “foldback” occurs when the current tries 
to exceed I
max
. This characteristic is developed as follows:
If the 5-7 load line is allowed to swing clockwise (resistance being reduced toward 
zero), the current path shown in Fig. 1.14.1 will be traced out. From its initial working cur-
rent (say 1 A at point P1), the current first rises to its limiting value I
max
, then falls toward 
zero as the load resistance is further reduced. For short-circuit conditions, the current falls 
to a low value I
sc
.
FIG. 1.14.2 (a) Foldback current limit circuit. (b) Regulator dissipation with reentrant 
protection.
1.116
PART 1
Since the header voltage of the linear regulator V
H
remains relatively constant through-
out this foldback current limiting action, the power dissipation in the series regulator 
transistor Q1 will initially increase with increasing currents, as shown in Fig. 1.14.2b.
The dissipation is small for the first part of the characteristic, but increases rapidly as the 
supply moves into current limit. It has a maximum value at a current at which the regulator 
transistor voltage drop I
load
product is a maximum [where (V
H
 V
out
)I
load
is maximum]—
in this example, at a current of 2.2 A, where there is a maximum dissipation in Q1 P
max
of 6.8 W. 
When the load resistance is reduced further (below this critical value), the series regula-
tor dissipation is progressively reduced as a result of the current foldback. It has a minimum 
value of P(Q1)  I
sc
V
H
watts in this example. This results in a dissipation of 1.8 W under 
short-circuit conditions.
It should be noticed that had the current limit characteristic been a constant-current type 
(shown by the vertical dashed path B in Fig. 1.14.1), the maximum dissipation under short-
circuit conditions would have been I
max
V
H
, or 12.8 W in this example. Hence the constant 
current limit places considerably greater stress on the regulator transistor than the reentrant 
characteristic in the linear regulator example.
14.4 “LOCKOUT” IN FOLDBACK CURRENT-
LIMITED SUPPLIES 
With the resistive load (the straight-line loads depicted in Figs. 1.14.1 and 1.14.3), there 
can only be one stable point of operation, defined by the intersection of the load line for 
a range of given loads with the power supply characteristic (for example, all points P1). 
FIG. 1.14.3 Overload and start-up characteristics of a foldback, current-limited 
supply, showing performance for linear and nonlinear load lines.
14. FOLDBACK (REENTRANT) OUTPUT CURRENT LIMITING
1.117
Hence, the reentrant characteristic shown would be swept out as the load resistance is 
varied from maximum to zero. This characteristic is swept out without instability or 
“lockout”; however, this smooth shutdown may not occur with nonlinear loads. 
Figure 1.14.3 shows a very nonlinear load line R3 (such as may be encountered 
with tungsten filament lamps) impressed on the power supply reentrant current limit 
characteristic.
It should be understood that a tungsten filament lamp has a very low resistance when it 
is first switched on (because of the low temperature of the filament wire). Consequently, a 
relatively large current flows at low applied voltages. As the voltage and current increase, 
the temperature and resistance of the filament increase, and the working point changes 
to a higher resistance. A nonlinear characteristic is also often found in active semicon-
ductor circuits.
It should be noticed that this nonlinear load line crosses the power supply reentrant 
current characteristic at three points. Points P1 and P2 are both stable operating points 
for the power supply. When such a supply-load combination is first switched on, the 
output voltage is only partially established to point P2, and lockout occurs. (It is inter-
esting to note that if the supply is switched on before the load is applied, it may be 
expected that the correct working point P1 will be established.) However, point P1 is a 
stable operating point only for a lamp that was previously working. When the lamp is 
first switched on, lockout will still occur at point P2, during the lamp power-up phase. 
This is caused because the slope resistance of the lamp load line at point P2 is less than 
the slope of the power supply reentrant characteristic at the same point. Since P2 is 
a stable point, lockout is maintained, and in this example the lamp would never be 
fully turned on.
Reentrant lockout may be cured in several ways. The reentrant characteristic of the 
power supply may be modified to bring it outside the nonlinear load line of the lamp, as 
shown in plots B and C in Fig. 1.14.4. This characteristic now provides only one stable 
mode of operation at point P1. However, modifying the current limit characteristic means 
that under short-circuit conditions the current is increased, with a corresponding increase 
FIG. 1.14.4 Nonlinear load line, showing “lockout” and modified charac-
teristics to prevent lockout.
Documents you may be interested
Documents you may be interested