c# pdf reader writer : Delete a page from a pdf online SDK application project wpf html winforms UWP TerraSyncReferenceManual26-part883

TerraSync Software Reference Manual     251
Advanced Data Collection     7
Using an Internet connection
To use an Internet VRS connection:
1. Use the Control Panel or the Remote Connections control to 
connect to the Internet.
B
Tip – Use Microsoft Pocket Internet Explorer to check that the Internet 
connection is working.
2. Connect to the VRS server:
a. Run the TerraSync software and open the Setup section.
b. If the TerraSync software is not connected to the GPS 
receiver, tap the GPS button to connect to the GPS receiver.
c. If you selected the Auto option in the Connection Control 
field, the TerraSync software automatically initiates the 
connection to the VRS server. If you selected the Manual 
option, you must initiate the connection to the server. To do 
this, tap 
Options
and select Connect to External Source.
3. Proceed with data collection. Use the Real-time Summary screen 
in the Status section if you want to check the VRS status.
4. When you have finished using the VRS correction source:
a. To disconnect from the VRS server, in the TerraSync 
software’s Setup section tap 
Options
and then select 
Disconnect from External Source.
b. If you have finished using the Internet, use the Control 
Panel or the Remote Connections control to disconnect 
from the Internet.
Delete a page from a pdf online - remove PDF pages in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Provides Users with Mature Document Manipulating Function for Deleting PDF Pages
delete page pdf acrobat reader; delete pages from pdf file online
Delete a page from a pdf online - VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Visual Basic Sample Codes to Delete PDF Document Page in .NET
delete pages pdf preview; copy pages from pdf to another pdf
7     Advanced Data Collection
252     TerraSync Software Reference Manual
70.1
Direct Dial Connection Method
The direct dial connection method uses a cellphone and modem, or a 
cellular modem, to dial up the VRS server directly. Unlike the Internet 
connection method, a direct dial connection is configured, established, 
and terminated from within the TerraSync software.
Authentication
If the call is authenticated using Caller ID, you will need to inform the 
VRS provider of the cellphone number that you are using. Otherwise, 
you may need to configure the modem to use a terminal window after 
dialling.
Before you begin
For a direct dial connection, you need the following information from 
the VRS provider:
The dial-up telephone number of the VRS server
Your VRS username and password, if the VRS provider requires 
you to enter these details when you connect to the server
Configuration
To configure the TerraSync software to establish a direct dial 
connection to a VRS source:
1. Install any software or drivers for the modem.
2. Start the TerraSync software and open the Setup section.
3. Tap 
Real-time Settings
. The Real-time Settings form appears.
4. In the Choice 1 field, select External Source.
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
Provides you with examples for adding an (empty) page to a PDF and adding empty pages You may feel free to define some continuous PDF pages and delete.
delete pdf pages reader; delete pdf pages in reader
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF C# File: Split PDF; C# Page: Insert PDF pages; C# Page: Delete PDF pages;
delete page on pdf reader; delete pages from pdf without acrobat
TerraSync Software Reference Manual     253
Advanced Data Collection     7
5. Configure the external source:
a. Tap the Setup button beside the Choice 1 field. The 
External Source Settings form (see page 201) appears.
b. In the Type field, select VRS.
c. In the Connection Method field, select Direct Dial.
d. In the Modem Type field, select the modem that you want to 
use. Then tap the Setup button to open the Connection 
Properties form.
e. Specify appropriate port connection settings. For detailed 
connection information, refer to the documentation for the 
cellphone or cellular modem.
f. If the call is authenticated with a username and password, 
select the Use terminal window after dialing check box.
g. Tap 
OK
to return to the External Source Settings form.
h. In the Phone Number field, enter the telephone number of 
the VRS server, including any prefix or area code required.
i. In the Connection Control field, select Auto to automatically 
connect to and disconnect from the VRS server as 
necessary. Select Manual to only connect or disconnect 
when you tap 
Options
in the Setup screen.
j. Tap 
OK
to confirm the settings and return to the Real-time 
Settings form.
6. Tap 
OK
.
C# PDF Page Insert Library: insert pages into PDF file in C#.net
Free components and online source codes for .NET framework 2.0+. PDF document files by C# code, how to rotate PDF document page, how to delete PDF page using C#
delete blank pages in pdf; delete pages of pdf preview
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF C# File: Split PDF; C# Page: Insert PDF pages; C# Page: Delete PDF pages;
delete pages pdf file; delete a page from a pdf in preview
7     Advanced Data Collection
254     TerraSync Software Reference Manual
Using a direct dial connection
To use a direct dial connection:
1. Connect to the VRS server:
a. If the TerraSync software is not connected to the GPS 
receiver, tap the GPS button to connect to the GPS receiver.
b. If you selected the Auto option in the Connection Control 
field, the TerraSync software automatically initiates the 
connection. If you selected the Auto option, you must 
initiate the connection to the server. To do this, tap 
Options
and select Connect to External Source.
c. If necessary, enter your username and password in the 
terminal window that appears.
2. Proceed with data collection. Use the Real-time Summary screen 
in the Status section if you want to check the VRS status.
3. When you have finished using the VRS correction source:
a. To manually disconnect from the VRS server, in the 
TerraSync software’s Setup section tap 
Options
. Select 
Disconnect from External Source. 
b. To ensure that the call is ended, use the End Call command 
on the cellphone.
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
in VB.NET. Ability to create a blank PDF page with related by using following online VB.NET source code. Support .NET WinForms, ASP
delete pdf pages in preview; pdf delete page
VB.NET PDF - Convert PDF Online with VB.NET HTML5 PDF Viewer
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF C# File: Split PDF; C# Page: Insert PDF pages; C# Page: Delete PDF pages;
delete pdf pages online; delete pages from a pdf online
TerraSync Software Reference Manual     255
Advanced Data Collection     7
70.1
Serial Port Connection Method
Use a serial port connection to connect the field computer directly to a 
decoder box for a VRS that outputs SAPOS FKP corrections in the old 
format.
Before you begin
For a serial port connection, you need to know the serial 
communication parameters (baud rate, data bits, stop bits, parity) for 
the external device. Because the TerraSync software is directly 
connected to the device, no authentication information is required.
Configuration
To configure the TerraSync software to establish a serial port 
connection to a VRS source:
1. Start the TerraSync software and open the Setup section.
2. Tap 
Real-time Settings
. The Real-time Settings form appears.
3. In the Choice 1 field, select External Source.
4. Configure the external source:
a. Tap the Setup button beside the Choice 1 field. The 
External Source Settings form (see page 201) appears.
b. In the Type field, select VRS.
c. In the Connection Method field, select Serial Port.
d. In the Port field, select the COM port on the field computer 
that the external source is connected to.
e. Tap the Setup button beside the Port field to open the 
Receiver Port Settings form (see page 205)
f. Specify appropriate port connection settings. For detailed 
connection information, refer to the documentation for the 
external correction source.
VB.NET PDF - Annotate PDF Online with VB.NET HTML5 PDF Viewer
Ability to insert a text note after selected text. Allow users to draw freehand shapes on PDF page. VB.NET HTML5 PDF Viewer: Annotate PDF Online.
delete pages pdf files; delete pages in pdf reader
C# PDF remove image library: remove, delete images from PDF in C#.
Delete and remove all image objects contained in a specific to remove a specific image from PDF document page. Free .NET PDF SDK library download and online C#
delete page from pdf online; delete pages on pdf
7     Advanced Data Collection
256     TerraSync Software Reference Manual
g. Tap 
OK
to return to the External Source Settings form.
h. Tap 
OK
to confirm the settings and return to the Real-time 
Settings form.
5. Tap 
OK
.
Using a serial port connection
To use a serial port connection, connect to GPS, and then make sure 
that the decoder box is turned on and is receiving corrections. For more 
information, refer to the documentation for the decoder box.
TerraSync Software Reference Manual     257
Advanced Data Collection     7
7.1
High-Accuracy Data Collection
To achieve high accuracy for GPS positions, you need to use carrier 
phase data collection methods. Normally, GPS positions are calculated 
using code phase measurements: how long it takes for the unique code 
generated by each satellite (see PRN, page315) to reach the receiver. 
For greater accuracy, you can use carrier phase measurements, which 
work with the carrier signal that the PRN code is carried on. Carrier 
phase measurements are much more accurate, because the carrier 
signal has a much higher frequency than the PRN code, and this makes 
errors smaller.
In the TerraSync software, there are three ways to use carrier phase 
measurements:
You can log H-Star data from a GPS Pathfinder ProXH receiver. 
H-Star data collection uses carrier phase data, but requires 
much shorter occupation times in the field than normal carrier 
phase data collection.
You can log postprocessable carrier phase data from a GPS 
Pathfinder Pro XR, Pro XRS, ProXT, or ProXH receiver, or from a 
GeoXT handheld. This data can be postprocessed in the GPS 
Pathfinder Office software to achieve accuracy of 30 cm or less. 
See Collecting Carrier Phase Data for Postprocessing (see 
page 261).
You can use a survey receiver to receive real-time kinematic 
(RTK) measurements from an RTK base station. RTK positions 
have an accuracy of up to 1 cm. When TerraSync is operating in 
RTK mode, you cannot log uncorrected positions, and any RTK 
positions logged cannot be postprocessed. 
7     Advanced Data Collection
258     TerraSync Software Reference Manual
71.1
Logging H-Star Data
By connecting the TerraSync software to a receiver with H-Star
technology, such as the Trimble GPS Pathfinder ProXH receiver, you 
can collect high accuracy GPS data. With H-Star processing in Trimble 
postprocessing software, you can achieve accuracies of 30 cm (1ft) or 
better. Positions logged while standing still using an external dual-
frequency (L1/L2) antenna can achieve accuracies of 20cm (8 inches) 
or better after H-Star postprocessing.
Note – Accuracy estimates for GPS positions logged while moving may be 
larger than 20 cm (dual-frequency) or 30 cm (single frequency).
Status information
When collecting H-Star data, the TerraSync software provides 
additional status information:
A Predicted Postprocessed Accuracy (PPA) value for the feature 
is displayed in the status bar. 
If carrier lock is lost, a tooltip appears warning of the loss of lock, 
and showing the last PPA value. A warning sound is also given to 
indicate loss of lock.
Note – The PPA value is only an indicator of accuracy that can be 
achieved with H-Star postprocessing. The accuracy indicated by the PPA is 
not guaranteed.
Configuring the TerraSync software to collect H-Star 
data
If you have an H-Star capable receiver, configure the TerraSync software 
to collect H-Star data. To do this:
1. Tap the Section list button and select Setup to open the Setup 
section Setup Section (see page 175).
2. Tap 
Logging Settings
. The Logging Settings form (see page 
182) appears. 
TerraSync Software Reference Manual     259
Advanced Data Collection     7
3. Verify that the Log H-Star Data field is set to Auto.
Note – If your GPS receiver is not H-Star capable, the Auto setting 
corresponds to No. Select No if you have a GPS receiver that is H-Star 
capable but you do not want to log H-Star data. 
4. Tap 
OK
to close this form and confirm the changes you have 
made.
H-Star data logging is now enabled.
Collecting features
To log H-Star data, you require a clear view of the sky at all times, so 
avoid obstacles such as trees, bridges, and tall buildings. As you log a 
feature, the Predicted Post-processed Accuracy (PPA) value appears in 
the status bar. The PPA predicts the accuracy that will be achieved for 
the position after H-Star postprocessing. The value of the PPA 
correlates directly with the length of time that you have continuously 
collected H-Star data. To collect H-Star data you must:
be connected to a receiver that has H-Star technology
maintain lock on the required number of satellites 
maintain a maximum PDOP of 6 or less
When logging point features or averaged vertices, you must maintain 
lock on at least four satellites. When logging line and area features, you 
must maintain lock on at least five satellites. 
When the PPA value reaches the accuracy you require for a point 
feature or vertex, you can stop logging. For example, to collect a point 
feature with an estimated accuracy of 20cm, you will need to maintain 
lock on at least 4 satellites with a PDOP of 6 or less until the PPA 
indicator shows 20 cm. After H-Star postprocessing, the accuracy of the 
feature should be close to the value shown by the PPA (20 cm). The PPA 
indicates a 63% confidence level for the positions you collect. 
Note – If you lose lock while collecting a feature, the PPA value increases, 
and you will need to reacquire satellites and remain at the feature until 
the PPA value decreases to the required accuracy.
7     Advanced Data Collection
260     TerraSync Software Reference Manual
Advanced data collection
The TerraSync software does not stop logging automatically when the 
required accuracy is achieved, and it does not prevent you from closing 
a feature before the required accuracy is achieved, or before the lock 
period is complete.
You do not have to remain at the same feature until the PPA value is 
reached. If you are collecting a series of features and you have a clear 
view of the sky and so are unlikely to lose lock, you can move to the 
next feature before the required PPA is reached. Provided that the PPA 
shows the accuracy you require for the features, all of the features 
collected while lock was maintained will have the same accuracy value 
after H-Star postprocessing.
C
CAUTION – This data collection method is recommended only if you are 
unlikely to lose lock on the required number of satellites. If you lose lock 
while collecting a series of features, you will need to re-collect all of the 
features to obtain features with the accuracy you require. 
Documents you may be interested
Documents you may be interested