c# pdf viewer dll : Reorder pdf pages online software Library project winforms asp.net html UWP WinCCInformationSystemScripting_en-US238-part1356

.UserValue3 = 50
.UserValue4 = 75
End With
End Sub
See also
UserValue3 Property (Page 2379)
UserValue2-Eigenschaft (Page 2379)
UserValue1 Property (Page 2378)
GroupDisplay Object (Page 1927)
V
Value
Value Property
Description
Returns or defines the value of an object property.
Example:
Use the Value property if you wish to return or define a value with the aid of the Properties 
listing. In this example the property of an ActiveX Control will be accessed via the Value 
property: 
Sub AddActiveXControl()
'VBA769
Dim objActiveXControl As HMIActiveXControl
Set objActiveXControl = ActiveDocument.HMIObjects.AddActiveXControl("WinCC_Gauge2", 
"XGAUGE.XGaugeCtrl.1")
'
'Move ActiveX-Control:
objActiveXControl.Top = 40
objActiveXControl.Left = 60
'
'Modify individual properties:
objActiveXControl.Properties("BackColor").value = RGB(255, 0, 0)
End Sub
VBA for Automated Configuration
3.5 VBA Reference
WinCC: Scripting (VBS, ANSI-C, VBA)
System Manual, 02/2013, A5E32315920-AA
2381
Reorder pdf pages online - re-order PDF pages in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support Customizing Page Order of PDF Document in C# Project
pdf reverse page order online; how to move pages within a pdf
Reorder pdf pages online - VB.NET PDF Page Move Library: re-order PDF pages in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sort PDF Document Pages Using VB.NET Demo Code
reorder pages in pdf document; reorder pages pdf
See also
Property Object (Page 1985)
VALUE_ACCESS_FAULT Property
Description
Defines or returns the value that will be assigned to the dynamic property if tag status "Access 
to tag not permitted" occurs. 
The value of the VariableStateChecked property must be TRUE in order for the status to be 
evaluated. 
Example:
In the following example the radius of a circle is given dynamics with the The dynamization 
takes place be evaluating the status of a tag. If the tag does not return a status, a substitute 
value (ElseCase property) is defined:
Sub AddDynamicDialogToCircleRadiusTypeAnalog()
'VBA770
Dim objDynDialog As HMIDynamicDialog
Dim objCircle As HMICircle
Set objCircle = ActiveDocument.HMIObjects.AddHMIObject("Circle_A", "HMICircle")
Set objDynDialog = objCircle.Radius.CreateDynamic(hmiDynamicCreationTypeDynamicDialog, 
"'NewDynamic1'")
With objDynDialog
.ResultType = hmiResultTypeAnalog
.AnalogResultInfos.ElseCase = 200
'
'Activate analysis of variablestate
.VariableStateChecked = True
End With
With objDynDialog.VariableStateValues(1)
'
'define a value for every state:
.VALUE_ACCESS_FAULT = 20
.VALUE_ADDRESS_ERROR = 30
.VALUE_CONVERSION_ERROR = 40
.VALUE_HANDSHAKE_ERROR = 60
.VALUE_HARDWARE_ERROR = 70
.VALUE_INVALID_KEY = 80
.VALUE_MAX_LIMIT = 90
.VALUE_MAX_RANGE = 100
.VALUE_MIN_LIMIT = 110
.VALUE_MIN_RANGE = 120
.VALUE_NOT_ESTABLISHED = 130
.VALUE_SERVERDOWN = 140
.VALUE_STARTUP_VALUE = 150
.VALUE_TIMEOUT = 160
End With
VBA for Automated Configuration
3.5 VBA Reference
WinCC: Scripting (VBS, ANSI-C, VBA)
2382
System Manual, 02/2013, A5E32315920-AA
C# TIFF: How to Reorder, Rearrange & Sort TIFF Pages Using C# Code
Reorder, Rearrange and Sort TIFF Document Pages in C#.NET Application. C# TIFF Page Sorting Overview. Reorder TIFF Pages in C#.NET Application.
how to reverse page order in pdf; how to move pages within a pdf document
C# PDF: C# Code to Process PDF Document Page Using C#.NET PDF
C# PDF Page Processing: Sort PDF Pages - online C#.NET tutorial page for how to reorder, sort, reorganize or re-arrange PDF document files using C#.NET code.
how to rearrange pages in pdf document; change page order in pdf reader
End Sub
See also
VALUE_MAX_LIMIT Property (Page 2415)
VariableStateChecked Property (Page 2450)
VALUE_TIMEOUT Property (Page 2426)
VALUE_STARTUP_VALUE Property (Page 2425)
VALUE_SERVERDOWN Property (Page 2423)
VALUE_NOT_ESTABLISHED Property (Page 2422)
VALUE_MIN_RANGE Property (Page 2420)
VALUE_MIN_LIMIT Property (Page 2419)
VALUE_MAX_RANGE Property (Page 2417)
VALUE_INVALID_KEY Property (Page 2411)
VALUE_HARDWARE_ERROR Property (Page 2408)
VALUE_HANDSHAKE_ERROR Property (Page 2406)
VALUE_CONVERSION_ERROR Property (Page 2404)
VALUE_ADDRESS_ERROR Property (Page 2383)
VariableStateValue Object (Page 2037)
VALUE_ADDRESS_ERROR Property
Description
Defines or returns the value that will be assigned to the dynamic property if tag status 
"Addressing error" occurs. 
The value of the VariableStateChecked property must be TRUE in order for the status to be 
evaluated. 
Example:
In the following example the radius of a circle will be dynamically configured using the Dynamic 
dialog. The dynamization takes place be evaluating the status of a tag. If the tag does not 
return a status, a substitute value (ElseCase property) is defined: 
Sub AddDynamicDialogToCircleRadiusTypeAnalog()
'VBA771
Dim objDynDialog As HMIDynamicDialog
Dim objCircle As HMICircle
Set objCircle = ActiveDocument.HMIObjects.AddHMIObject("Circle_A", "HMICircle")
VBA for Automated Configuration
3.5 VBA Reference
WinCC: Scripting (VBS, ANSI-C, VBA)
System Manual, 02/2013, A5E32315920-AA
2383
VB.NET PowerPoint: Sort and Reorder PowerPoint Slides by Using VB.
Sort and Reorder PowerPoint Slides Range with VB amount of robust PPT slides/pages editing methods powerful & profession imaging controls, PDF document, image
change pdf page order; reorder pages in pdf online
VB.NET PDF: Create PDF Document Viewer in C#.NET for Document
"This online guide content is Support navigating to the previous or next page of the PDF document; Able to insert, delete or reorder PDF document page in VB.NET
reorder pdf pages reader; reverse page order pdf
Set objDynDialog = objCircle.Radius.CreateDynamic(hmiDynamicCreationTypeDynamicDialog, 
"'NewDynamic1'")
With objDynDialog
.ResultType = hmiResultTypeAnalog
.AnalogResultInfos.ElseCase = 200
'
'Activate analysis of variablestate
.VariableStateChecked = True
End With
With objDynDialog.VariableStateValues(1)
'
'define a value for every state:
.VALUE_ACCESS_FAULT = 20
.VALUE_ADDRESS_ERROR = 30
.VALUE_CONVERSION_ERROR = 40
.VALUE_HANDSHAKE_ERROR = 60
.VALUE_HARDWARE_ERROR = 70
.VALUE_INVALID_KEY = 80
.VALUE_MAX_LIMIT = 90
.VALUE_MAX_RANGE = 100
.VALUE_MIN_LIMIT = 110
.VALUE_MIN_RANGE = 120
.VALUE_NOT_ESTABLISHED = 130
.VALUE_SERVERDOWN = 140
.VALUE_STARTUP_VALUE = 150
.VALUE_TIMEOUT = 160
End With
End Sub
See also
VariableStateChecked Property (Page 2450)
VALUE_TIMEOUT Property (Page 2426)
VALUE_STARTUP_VALUE Property (Page 2425)
VALUE_SERVERDOWN Property (Page 2423)
VALUE_NOT_ESTABLISHED Property (Page 2422)
VALUE_MIN_RANGE Property (Page 2420)
VALUE_MIN_LIMIT Property (Page 2419)
VALUE_MAX_RANGE Property (Page 2417)
VALUE_MAX_LIMIT Property (Page 2415)
VALUE_INVALID_KEY Property (Page 2411)
VALUE_HARDWARE_ERROR Property (Page 2408)
VALUE_HANDSHAKE_ERROR Property (Page 2406)
VALUE_CONVERSION_ERROR Property (Page 2404)
VALUE_ACCESS_FAULT Property (Page 2382)
VariableStateValue Object (Page 2037)
VBA for Automated Configuration
3.5 VBA Reference
WinCC: Scripting (VBS, ANSI-C, VBA)
2384
System Manual, 02/2013, A5E32315920-AA
VB.NET TIFF: Modify TIFF File by Adding, Deleting & Sort TIFF
Users can use it to reorder TIFF pages in ''' &ltsummary> ''' Sort TIFF document pages in designed powerful & profession imaging controls, PDF document, image
reorder pdf pages; move pages within pdf
VB.NET PDF: VB.NET Guide to Process PDF Document in .NET Project
This online guide content It can be used to add or delete PDF document page(s), sort the order of PDF pages, add image to PDF document page and extract page(s
how to move pages in pdf converter professional; how to rearrange pages in a pdf file
VALUE_BAD_COMMLUV Property
Description 
Specifies the value assigned to a dynamized property if quality code "bad, no communication 
(last usable value)" occurs, or returns its value. 
In order for the quality code to be analyzed, the QualityCodeStateChecked property must be 
TRUE. 
Example:
In the following example the radius of a circle will be dynamically configured using the Dynamic 
dialog. Dynamization uses the analysis of the quality code of a tag. If the tag fails to return a 
quality code, a substitute value (ElseCase property) is defined:
Sub AddDynamicDialogToCircleRadiusTypeAnalog()
'VBA818
Dim objDynDialog As HMIDynamicDialog
Dim objCircle As HMICircle
Set objCircle = ActiveDocument.HMIObjects.AddHMIObject("Circle_A", "HMICircle")
Set objDynDialog = objCircle.Radius.CreateDynamic(hmiDynamicCreationTypeDynamicDialog, 
"'NewDynamic1'")
With objDynDialog
.ResultType = hmiResultTypeAnalog
.AnalogResultInfos.ElseCase = 200
'
'Activate analysis of qualitycodestate
.QualityCodeStateChecked = True
End With
With objDynDialog.QualityCodeStateValues(1)
'
'define a value for every state:
.VALUE_BAD_COMMLUV = 20
.VALUE_BAD_COMMNUV = 30
.VALUE_BAD_CONFERROR = 40
.VALUE_BAD_DEVICE = 60
.VALUE_BAD_MISCSTATES = 70
.VALUE_BAD_NONSPECIFIC = 80
.VALUE_BAD_NOTCONNECTED = 90
.VALUE_BAD_OUTOFSERV = 100
.VALUE_BAD_PROCRELNOM = 110
.VALUE_BAD_PROCRELSUB = 120
.VALUE_HIGHLIMITED = 130
.VALUE_LOWLIMITED = 140
.VALUE_UNCERT_ENGVHIGHLIM = 150
.VALUE_UNCERT_ENGVLOWLIM = 160
.VALUE_UNCERT_INITVAL = 170
.VALUE_UNCERT_LUV = 180
.VALUE_UNCERT_MAINTDEM = 190
.VALUE_UNCERT_MISCSTATES = 200
.VALUE_UNCERT_NONSPECIFIC = 210
.VALUE_UNCERT_PROCRELNOM = 220
VBA for Automated Configuration
3.5 VBA Reference
WinCC: Scripting (VBS, ANSI-C, VBA)
System Manual, 02/2013, A5E32315920-AA
2385
C# PDF Page Rotate Library: rotate PDF page permanently in C#.net
Online C# class source codes enable the ability to rotate single NET, add new PDF page, delete certain PDF page, reorder existing PDF pages and split
change page order in pdf online; rearrange pages in pdf file
VB.NET TIFF: VB.NET Sample Code to Process & Manage TIFF Page
certain TIFF page, and sort & reorder TIFF pages in Process TIFF Pages Independently in VB.NET Code. powerful & profession imaging controls, PDF document, image
change page order pdf; reordering pdf pages
.VALUE_UNCERT_SIMVAL = 230
.VALUE_UNCERT_SUBSTSET = 240
End With
End Sub
See also
VALUE_BAD_DEVICE Property (Page 2390)
QualityCodeStateChecked Properties (Page 2316)
VALUE_UNCERT_SUBSTSET Property (Page 2447)
VALUE_UNCERT_SIMVAL Property (Page 2445)
VALUE_UNCERT_PROCRELNOM Property (Page 2443)
VALUE_UNCERT_NONSPECIFIC Property (Page 2441)
VALUE_UNCERT_MISCSTATES Property (Page 2439)
VALUE_UNCERT_MAINTDEM Property (Page 2437)
VALUE_UNCERT_LUV Property (Page 2435)
VALUE_UNCERT_INITVAL Property (Page 2433)
VALUE_UNCERT_ENGVONLIM Property (Page 2431)
VALUE_UNCERT_ENGVLOWLIM Property (Page 2429)
VALUE_UNCERT_ENGVHIGHLIM Property (Page 2428)
VALUE_LOWLIMITED Property (Page 2413)
VALUE_HIGHLIMITED Property (Page 2409)
VALUE_BAD_PROCRELSUB Property (Page 2402)
VALUE_BAD_PROCRELNOM Property (Page 2400)
VALUE_BAD_OUTOFSERV Property (Page 2398)
VALUE_BAD_NOTCONNECTED Property (Page 2396)
VALUE_BAD_NONSPECIFIC Property (Page 2394)
VALUE_BAD_MISCSTATES Property (Page 2392)
VALUE_BAD_CONFERROR Property (Page 2388)
VALUE_BAD_COMMNUV Property (Page 2386)
QualityCodeStateValue Object (Page 1987)
VALUE_BAD_COMMNUV Property
Description
Specifies the value assigned to a dynamized property if quality code "bad, no communication 
(last usable value)" occurs, or returns its value. 
VBA for Automated Configuration
3.5 VBA Reference
WinCC: Scripting (VBS, ANSI-C, VBA)
2386
System Manual, 02/2013, A5E32315920-AA
In order for the quality code to be analyzed, the QualityCodeStateChecked property must be 
TRUE. 
Example:
In the following example the radius of a circle will be dynamically configured using the Dynamic 
dialog. Dynamization uses the analysis of the quality code of a tag. If the tag fails to return a 
quality code, a substitute value (ElseCase property) is defined:
Sub AddDynamicDialogToCircleRadiusTypeAnalog()
'VBA770
Dim objDynDialog As HMIDynamicDialog
Dim objCircle As HMICircle
Set objCircle = ActiveDocument.HMIObjects.AddHMIObject("Circle_A", "HMICircle")
Set objDynDialog = objCircle.Radius.CreateDynamic(hmiDynamicCreationTypeDynamicDialog, 
"'NewDynamic1'")
With objDynDialog
.ResultType = hmiResultTypeAnalog
.AnalogResultInfos.ElseCase = 200
'
'Activate analysis of qualitycodestate
.QualityCodeStateChecked = True
End With
With objDynDialog.QualityCodeStateValues(1)
'
'define a value for every state:
.VALUE_BAD_COMMLUV = 20
.VALUE_BAD_COMMNUV = 30
.VALUE_BAD_CONFERROR = 40
.VALUE_BAD_DEVICE = 60
.VALUE_BAD_MISCSTATES = 70
.VALUE_BAD_NONSPECIFIC = 80
.VALUE_BAD_NOTCONNECTED = 90
.VALUE_BAD_OUTOFSERV = 100
.VALUE_BAD_PROCRELNOM = 110
.VALUE_BAD_PROCRELSUB = 120
.VALUE_HIGHLIMITED = 130
.VALUE_LOWLIMITED = 140
.VALUE_UNCERT_ENGVHIGHLIM = 150
.VALUE_UNCERT_ENGVLOWLIM = 160
.VALUE_UNCERT_INITVAL = 170
.VALUE_UNCERT_LUV = 180
.VALUE_UNCERT_MAINTDEM = 190
.VALUE_UNCERT_MISCSTATES = 200
.VALUE_UNCERT_NONSPECIFIC = 210
.VALUE_UNCERT_PROCRELNOM = 220
.VALUE_UNCERT_SIMVAL = 230
.VALUE_UNCERT_SUBSTSET = 240
End With
End Sub
VBA for Automated Configuration
3.5 VBA Reference
WinCC: Scripting (VBS, ANSI-C, VBA)
System Manual, 02/2013, A5E32315920-AA
2387
See also
QualityCodeStateChecked Properties (Page 2316)
VALUE_UNCERT_SUBSTSET Property (Page 2447)
VALUE_UNCERT_SIMVAL Property (Page 2445)
VALUE_UNCERT_PROCRELNOM Property (Page 2443)
VALUE_UNCERT_NONSPECIFIC Property (Page 2441)
VALUE_UNCERT_MISCSTATES Property (Page 2439)
VALUE_UNCERT_MAINTDEM Property (Page 2437)
VALUE_UNCERT_LUV Property (Page 2435)
VALUE_UNCERT_INITVAL Property (Page 2433)
VALUE_UNCERT_ENGVONLIM Property (Page 2431)
VALUE_UNCERT_ENGVLOWLIM Property (Page 2429)
VALUE_UNCERT_ENGVHIGHLIM Property (Page 2428)
VALUE_LOWLIMITED Property (Page 2413)
VALUE_HIGHLIMITED Property (Page 2409)
VALUE_BAD_PROCRELSUB Property (Page 2402)
VALUE_BAD_PROCRELNOM Property (Page 2400)
VALUE_BAD_OUTOFSERV Property (Page 2398)
VALUE_BAD_NOTCONNECTED Property (Page 2396)
VALUE_BAD_NONSPECIFIC Property (Page 2394)
VALUE_BAD_MISCSTATES Property (Page 2392)
VALUE_BAD_DEVICE Property (Page 2390)
VALUE_BAD_CONFERROR Property (Page 2388)
VALUE_BAD_COMMLUV Property (Page 2385)
QualityCodeStateValue Object (Page 1987)
VALUE_BAD_CONFERROR Property
Description
Specifies the value assigned to a dynamized property if quality code "bad, no communication, 
value not accepted" occurs, or returns its value. 
In order for the quality code to be analyzed, the QualityCodeStateChecked property must be 
TRUE. 
VBA for Automated Configuration
3.5 VBA Reference
WinCC: Scripting (VBS, ANSI-C, VBA)
2388
System Manual, 02/2013, A5E32315920-AA
Example:
In the following example the radius of a circle will be dynamically configured using the Dynamic 
dialog. Dynamization uses the analysis of the quality code of a tag. If the tag fails to return a 
quality code, a substitute value (ElseCase property) is defined:
Sub AddDynamicDialogToCircleRadiusTypeAnalog()
'VBA770
Dim objDynDialog As HMIDynamicDialog
Dim objCircle As HMICircle
Set objCircle = ActiveDocument.HMIObjects.AddHMIObject("Circle_A", "HMICircle")
Set objDynDialog = objCircle.Radius.CreateDynamic(hmiDynamicCreationTypeDynamicDialog, 
"'NewDynamic1'")
With objDynDialog
.ResultType = hmiResultTypeAnalog
.AnalogResultInfos.ElseCase = 200
'
'Activate analysis of qualitycodestate
.QualityCodeStateChecked = True
End With
With objDynDialog.QualityCodeStateValues(1)
'
'define a value for every state:
.VALUE_BAD_COMMLUV = 20
.VALUE_BAD_COMMNUV = 30
.VALUE_BAD_CONFERROR = 40
.VALUE_BAD_DEVICE = 60
.VALUE_BAD_MISCSTATES = 70
.VALUE_BAD_NONSPECIFIC = 80
.VALUE_BAD_NOTCONNECTED = 90
.VALUE_BAD_OUTOFSERV = 100
.VALUE_BAD_PROCRELNOM = 110
.VALUE_BAD_PROCRELSUB = 120
.VALUE_HIGHLIMITED = 130
.VALUE_LOWLIMITED = 140
.VALUE_UNCERT_ENGVHIGHLIM = 150
.VALUE_UNCERT_ENGVLOWLIM = 160
.VALUE_UNCERT_INITVAL = 170
.VALUE_UNCERT_LUV = 180
.VALUE_UNCERT_MAINTDEM = 190
.VALUE_UNCERT_MISCSTATES = 200
.VALUE_UNCERT_NONSPECIFIC = 210
.VALUE_UNCERT_PROCRELNOM = 220
.VALUE_UNCERT_SIMVAL = 230
.VALUE_UNCERT_SUBSTSET = 240
End With
End Sub
VBA for Automated Configuration
3.5 VBA Reference
WinCC: Scripting (VBS, ANSI-C, VBA)
System Manual, 02/2013, A5E32315920-AA
2389
See also
VALUE_UNCERT_MISCSTATES Property (Page 2439)
QualityCodeStateChecked Properties (Page 2316)
VALUE_UNCERT_SUBSTSET Property (Page 2447)
VALUE_UNCERT_SIMVAL Property (Page 2445)
VALUE_UNCERT_PROCRELNOM Property (Page 2443)
VALUE_UNCERT_NONSPECIFIC Property (Page 2441)
VALUE_UNCERT_MAINTDEM Property (Page 2437)
VALUE_UNCERT_LUV Property (Page 2435)
VALUE_UNCERT_INITVAL Property (Page 2433)
VALUE_UNCERT_ENGVONLIM Property (Page 2431)
VALUE_UNCERT_ENGVLOWLIM Property (Page 2429)
VALUE_UNCERT_ENGVHIGHLIM Property (Page 2428)
VALUE_LOWLIMITED Property (Page 2413)
VALUE_HIGHLIMITED Property (Page 2409)
VALUE_BAD_PROCRELSUB Property (Page 2402)
VALUE_BAD_PROCRELNOM Property (Page 2400)
VALUE_BAD_OUTOFSERV Property (Page 2398)
VALUE_BAD_NOTCONNECTED Property (Page 2396)
VALUE_BAD_NONSPECIFIC Property (Page 2394)
VALUE_BAD_MISCSTATES Property (Page 2392)
VALUE_BAD_DEVICE Property (Page 2390)
VALUE_BAD_COMMNUV Property (Page 2386)
VALUE_BAD_COMMLUV Property (Page 2385)
QualityCodeStateValue Object (Page 1987)
VALUE_BAD_DEVICE Property
Description
Specifies a value assigned to a dynamized property if quality code "bad, device failure" occurs, 
or returns its value. 
In order for the quality code to be analyzed, the QualityCodeStateChecked property must be 
TRUE. 
VBA for Automated Configuration
3.5 VBA Reference
WinCC: Scripting (VBS, ANSI-C, VBA)
2390