c# show a pdf file : How to move pages in pdf files Library control component .net web page html mvc Visual_2012_Help18-part727

7.. (lace and 0im Luminaire"
Place and Aim
allows Luminaires to be graphically aimed in the direction of a chosen coordinate. This command allows for placement and graphical manipulation of the 
Orientation
and 
Tilt
parameters for each placement instance. This method is useful for floodlighting, track lighting, sports lighting, and landscape lighting.
The 
Place and Aim
command can be found on the 
Luminaire
tab and the
Home
tab of the 
Ribbonbar
.
The 
Home
tab button is dual function; the upper portion executes the
command, the lower portion initiates a drop-down menu.
Once a selection has been made other than the default, the upper button
portion will change to execute that command with the next press and the
graphic is changed accordingly. Selecting one of the other commands from the
drop-down menu will revert the button to that mode.
To insert a Luminaire, one must first be defined in the
Luminaire Schedule
.
See The 
Luminaire Schedule Editor
for more information.
To 
Place and Aim
Luminaire, select a Luminaire Type from the
graphical list. Select the coordinates desired for the Luminaire location with
the mouse, keyboard entry or 
Object Snap
. Visual then provides instant
feedback by placing the aim point at the mouse crosshairs and shows the
resultant 
Aiming Line
and Luminaire orientation as the mouse is moved.
Specify the aiming point with the mouse, keyboard, or 
Object Snap
.
After a Luminaire is inserted with 
Place and Aim
, Visual continues the
command to allow for multiple insertions. To end the command, right-click or
press Enter.
How to move pages in pdf files - re-order PDF pages in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support Customizing Page Order of PDF Document in C# Project
how to reorder pages in pdf preview; reverse page order pdf online
How to move pages in pdf files - VB.NET PDF Page Move Library: re-order PDF pages in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sort PDF Document Pages Using VB.NET Demo Code
pdf page order reverse; reorder pages in pdf online
By clicking the 
Luminaire Type List
during command execution, all defined
Luminaire
Types
are shown and a selection can be made.
SymbolType, and Catalog Number are shown to identify types in complex
projects.
Preceding the 
Catalog Number
is a number in square brackets representing
the number of that Luminaire Type currently inserted in the 
Design
Environment
.
Mounting Height
is the distance from the
Active Plane
that the Luminaire
will be inserted. Mounting Height is always applied in the z-direction.
Changes to the
Active Plane
orientation (i.e. moving to the X-Z or Y-Z planes)
will still result in the Mounting Height being applied in the Z-direction.
Orientation
and 
Tilt
are solely specified by user input at the 
Command Line
in this command, most often with the mouse. The 
Orientation
and 
Tilt
parameter text boxes are accordingly inactive.
Aim to Surface
(found on the 
Luminaire
tab) is applicable to the Place 
and
Aim
command.  Because in many floodlighting applications it is necessary to
have the Luminaire aimed onto a specific surface, Visual can determine when
the mouse is placed "over" a 
Solid Object
and the Active Plane can be
automatically and temporarily changed to the plane of that 
Solid Object
such
that when the mouse is clicked the aiming point is placed in the plane of that
Solid Object
.
See Luminaire Display Options
for further explanation of augmentation to Luminaires to aid in design.
C# PowerPoint - Sort PowerPoint Pages Order in C#.NET
library control, developers can swap or adjust the order of all or several PowerPoint document pages, or just change the C# DLLs: Move PowerPoint Page Position.
move pages in a pdf file; pdf reverse page order online
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
Images. File and Page Process. File: Merge, Append PDF Files. File: Split PDF Document. Page: Replace PDF Pages. Page: Move Page Position. Page: Extract, Copy
how to change page order in pdf acrobat; how to reorder pages in pdf
7.. $eaimin Luminaire"
Once inserted into the 
Design Environment
Luminaires can be 
Reaimed
if necessary.
The 
Reaim
command can be found on the Luminaire tab and the 
Home
tab
of the 
Ribbonbar
.
The 
Home
tab button is dual function; the upper portion executes the command,
the lower portion initiates a drop-down menu.
Once a selection has been made other than the default, the upper button portion
will change to execute that command with the next press and the graphic is
changed accordingly. Selecting one of the other commands from the drop-down
menu will revert the button to that mode.
To 
Reaim
Luminaire, left-click the luminaire Symbol or the 
Aiming Line
(if
displayed). Visual will highlight the selected luminaire. Specify the new aiming
point with the mouse, keyboard, or 
Object Snap
.
While in the command, Visual displays the previous 
Aiming Line
, the new
Aiming Line
attached to the mouse crosshairs, and the resultant Symbol
alignment as the mouse is moved.
Aim to Surface
(found on the Luminaire tab) is applicable to the 
Reaim
command just as it would be to the initial 
Place and Aim
command. Visual can
determine when the mouse is placed "over" a 
Solid Object
and the Active
Plane can be automatically and temporarily changed to the plane of that Solid
Object
such that when the mouse is clicked the aiming point is placed in the
plane of that 
Solid Object
.
See Luminaire 
Properties
for information about displaying aiming lines.
C# PDF Image Extract Library: Select, copy, paste PDF images in C#
Get JPG, JPEG and other high quality image files from PDF Scan image to PDF, tiff and various image formats. Able to edit, add, delete, move, and output PDF
how to reorder pdf pages in; move pages in a pdf
VB.NET PDF Library SDK to view, edit, convert, process PDF file
Rapidly and multiple PDF document (pages) creation and edit methods file formats; merge, append, and split PDF files; insert, delete, move, rotate, copy
how to rearrange pages in pdf using reader; move pdf pages in preview
Luminaire -i"pla /pn"
After Luminaires have been placed in the 
Design Environment
, there are  ways to augment the display to aid in design.
Luminaire display options are found on the Luminaire tab of
the 
Ribbonbar
.
Luminaire Labels can be shown with the Luminaire Type or
the Luminaire Type
and Number
.
When the 
Display
is set to Luminaire Type
and Number
,
Visual activates the following additional options:
Sequence
tells Visual how to handle numbering across
Luminaire
Types
Sequential
will number Luminaires
regardless of Luminaire Type. 
Non-Sequential
will re-start
numbering for each Luminaire Type.
Reset Luminaire Numbers
. controls the numbering used
with the 
Sequence
options. 
Sort By Creation Order
tells
Visual to number Luminaires based on the order they are
placed (created) in the 
Design Environment
regardless of
where they are placed. 
Sort By Location Order
tells Visual to
use the internal algorithm for sorting based on the relative
position in the Cartesian X-Y plane.
The 
Templates
button turns on or off the global display of
iso-illuminance templates for 
Luminaire
Types
where
Templates
have been defined in the 
Luminaire
Schedule
.
See Luminaire 
Templates
for information on defining
Templates
.
C# PDF Page Insert Library: insert pages into PDF file in C#.net
how to merge PDF document files by C# code, how to rotate PDF document page, how to delete PDF page using C# .NET, how to reorganize PDF document pages and how
how to reorder pdf pages in reader; how to move pages in a pdf document
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
Merge two or several separate PDF files together and into one PDF document in VB.NET. Combine multiple specified PDF pages in into single one file.
how to rearrange pdf pages reader; reorder pages pdf
The 
Photometric Web
button turns on or off the display of the
Photometric Web
for the luminaire currently being placed. It
does not impact already placed Luminaires; see Luminaire
Properties
for information on controlling display of placed
Luminaires.
The 
Photometric Web
illustrates the shape of the candela
distribution and provides visual feedback as to proper alignment.
Note that the magnitude is scaled to  allow for all sizes to be
visible. For example, a 32W CFL downlight will have the same
magnitude as a 4-lamp troffer or a 1000W metal halide floodlight
even though actual candlepower could be 10,000X different.
Analogous to the 
Photometric Web
button when inserting
Luminairesthe Distribution button found on the Luminaire
tab of the 
Ribbonbar
initiates a drop-down menu that allows the
user to turn on or off 
Photometric Webs
in the 
Design
Environment
for all Luminaires.
The
Luminous Volume
button directs Visual to display the
luminous dimensions graphically (as seen in the wireframe view
at middle-right) for each placed Luminaire in the 
Design
Environment
in conjunction with the Symbol as defined in the
Luminaire Schedule
.
Design 
Audit
will automatically turn on this feature when an
interference is found. At right, the wall sconce Symbol is
aligned properly but the alignment of the Symbol and the
Photometric File is incorrect, yielding half of the luminous area
inside a wall as can be seen in plan view.
C# PDF insert text Library: insert text into PDF content in C#.net
character and text string to PDF files using online int pageIndex = 0; // Move cursor to (400F outputFilePath = Program.RootPath + "\\" output.pdf"; doc.Save
how to rearrange pages in a pdf reader; reverse pdf page order online
C# PDF File Split Library: Split, seperate PDF into multiple files
can split target PDF document file by specifying a page or pages. If needed, developers can also combine generated split PDF document files with other PDF
move pages in pdf online; reorder pdf page
Chapter 8 - Calcula  a   e ult
Visual's primary function is to calculate illuminance levels at distinct locations in the
lighting model for the purpose of lighting system performance verification.  This
chapter provides a brief overview of the calculations and the techniques for interpreting
the results.
Basic knowledge of lighting equipment and metrics is necessary prior to using Visual to be able to understand the ramifications of choices made in the program and the resultant numbers. Most
local sections of the Illuminating Engineering Society
provide Fundamentals of Lighting classes to suit this purpose.
An advanced discussion of the Visual Calculation 
Engine
is provided in the Appendices of this manual.
8 Calcula e
Calculation Zones
are an integral part of any lighting model. Statistical information related to
Calculation Zones
is displayed in the 
Sidebar
. See Statistics
and The 
Sidebar
for more
information.
Calculation Zones
can be lighting-based (Illuminance,
Luminanceetc) or power-based (Lighting Power Density). By
default, Visual shows L
ighting Calculation Zones
in dark red and
Lighting Power Density Zones
are shown with a olive border and
are furthermore shaded.
Lighting Calculation Zones
can be defined by rectangular areas,
areas bounded by a polygon, or can be locations along a linear path.
Calculation Zones
can also be placed directly on surfaces (
Solid
Objects
).
The boundary of the 
Calculation Zone
is indicated by a dashed line
and points indicated by crosses are placed in an array defined by the
user.
Visual assumes the light meter orientation to be perpendicular to the
defining (bounding) plane. This can be modified at creation or by editing
Properties
after creation.
Lighting Calculation Zones
can be modified to remove points that
are unwanted using the Masking commands. Points can be 
Masked
with rectangles, polygons, by surface, or individually.
Mask
boundaries are shown with a dashed purple line.
The display of the 
Mask
boundary can be turned on or off in the
Settings
dialog
.
Statistical Zones
can be created to report information about part of a
Lighting Calculation Zone
Statistical Zones
are displayed in the
Statistics
tab of the 
Sidebar
separately from their parent zone.
Statistical Zones
can be created with rectangles, polygons, or by
selecting surfaces. 
Statistical Zones
can be grouped in the 
Sidebar
for an additional level of reporting and analysis.
Statistical Zone
boundaries are shown with a dashed dark green line.
Notice how the internal points are omitted by astute boundary selection.
Calculation points included in the 
Statistical Zone
have a different
symbol.
For example, only the paved area could be shown for a parking lot.
Points in the 
Statistical Zone
are indicated with a green asterisk
symbol by default.
Lighting Power Density
(
LPD
Zones
can be defined by
rectangular areas, areas bounded by a polygon. They have associated
luminaires specifically applied to the calculation. 
LPD Zones
can also
be placed directly on surfaces (
Solid Objects
).
When changes have been made to the lighting model that require a re-
calculation, Visual will indicate that 
Calculation Zone
values may no
longer be valid by bracketing point values.
The following section describes the process of entering 
Calculation Zones
along with the information required to produce appropriate results.
8  ectaular a  lal Calcula e
Calculation Zones
may exist along a linear path or within planar regions bounded by a rectangle or polygon.
The buttons for the various types of 
Calculation Zones
can be found in the
Calculations
panel on the 
Home
tab or the 
Calculation Zone
panel on the
Calculations 
tab of the 
Ribbonbar
.
The 
Home
tab buttons are dual function; the upper portion executes the command,
the lower portion initiates a drop-down menu.
Once a selection has been made other than the default, the upper button portion will
change to execute that command with the next press and the graphic is changed
accordingly. Selecting one of the other commands from the drop-down menu will
revert the button to that mode.
Rectangular 
and Polygonal
Calculation Zones
share a similar interface in the
Properties
tab of the 
Ribbonbar
that is shown upon command execution.
See Calculation 
Zone Parameters
for information on specific parameters.
Note that the basic process of creating 
Calculation Zones
is identical to that of creating 
Background
or 
Solid
Rectangles
and 
Polygons
except that additional information must be
entered on the 
Properties
tab to space and format the points.
To construct a 
Rectangle Calculation Zone
, specify the coordinates of the first
vertex using the mouse, keyboard, or 
Object Snap
. In the command, moving the
mouse causes Visual to draw the implied 
Rectangle 
showing what will be created
when the command is completed. To end the command, right-click the mouse or
press Enter. Various parameters can be specified in the 
Properties
tab as
discussed below.
To construct a Polygon
Calculation Zone
, specify the coordinates of the vertices
using the mouse, keyboard, or 
Object Snap
. In the command, moving the mouse
causes Visual to draw two types of implied lines: the small-dash line connects the
first vertex and the last vertex specified and the large-dash line connects the cursor
to the last vertex specified. To end the command, right-click the mouse or press
Enter. Various parameters can be specified in the 
Properties
tab as discussed
below.
When changes have been made to the lighting model that require a re-calculation,
Visual will indicate that 
Calculation Zone
values may no longer be valid by
bracketing point values.
In all cases, the default point normal (virtual light meter) orientation is 
Directional (Perpendicular)
that corresponds to a direction perpendicular to the plane of the 
Calculation Zone
bounding
rectangle, polygon, or line. Several other options can be chosen to change how Visual orients the virtual light meter. See Calculation 
Types
for other meter orientation options.
Statistical information related to
Calculation Zones
is displayed in the 
Sidebar
. See Statistics
and The 
Sidebar
for more information.
Documents you may be interested
Documents you may be interested