The available columns for a 
Luminaire Schedule
are:
Symbol - The Symbol defined in the Luminaire Schedule Editor
Label - The text label defined in the Luminaire Schedule Editor
Image
- The graphic assigned in the Acuity Brands database
QTY
(Quantity) - The number of the 
Luminaire Type
placed in the model
Manufacturer
- Text from the [MANUFAC] field of the IES file or that edited in the 
Luminaire Schedule Editor
Catalog Number
- Text from the [LUMCAT] field of the IES file or that edited in the 
Luminaire Schedule Editor
Description
- Text from the [LUMINAIRE] field of the IES file or that edited in the 
Luminaire Schedule Editor
Lamp - Text from the [LAMP] field of the IES file or that edited in the Luminaire Schedule Editor
Number Of Lamps
- Text from the IES file or that edited in the 
Luminaire Schedule Editor
Filename
- The name of the IES files used as the base of the 
Luminaire Type 
definition
Lumens Per Lamp
- Text from the IES file or that edited in the 
Luminaire Schedule Editor
LLF
- The
Light Loss Factor
assigned in the 
Luminaire Schedule Editor
Wattage
- Text from the IES file or that edited in the 
Luminaire Schedule Editor
Efficiency - The calculated efficiency from the information in the IES file
Distribution
- The IES classification and spacing criterion (SC) across and along the lamps
Plot
- A miniaturized candlepower graph in polar coordinates (otherwise called a polar plot or candela curve)
Notes
- This is the only field NOT based on the 
Luminaire Schedule Editor
. When this column is shown, it allows for insertion of additional text-based information using the editing
method in Working 
with Text-Based Objects
Once placed, the object can be modified in many ways. See Working 
With Text-Based Objects
for information about formatting headers.
Visual has default settings of common content. The default may differ on any one computer based on user choices; see Saving 
Templates and Defaults
.
How to reorder pdf pages in reader - re-order PDF pages in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support Customizing Page Order of PDF Document in C# Project
how to reverse page order in pdf; rearrange pages in pdf online
How to reorder pdf pages in reader - VB.NET PDF Page Move Library: re-order PDF pages in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sort PDF Document Pages Using VB.NET Demo Code
move pages in pdf file; pdf reorder pages
11.. *u+inaire *ocaon
Luminaire Locations
shows a table with data about position and aiming of each 
Luminaire
in the model.
To place a 
Luminaire Locations 
table on a Page, click the
Luminaire Locations
button on the 
Insert
tab  of the 
Print Editor Ribbonbar
.
Luminaire Locations
is placed by left-clicking the mouse in the desired location as
described in Placing 
Objects
.
See Working 
with Text-Based Objects
for information on editing text content.
See Working 
With Tabular Objects
for information on formatting tables as well as
choosing columns to display.
The available columns for 
Luminaire Locations 
are:
No.
- The 
Luminaire Number
based on the sort method chosen for 
Luminaire 
Labels
in the 
Design Environment
Label -  The Luminaire Type Label as assigned in the Luminaire Schedule Editor
Location (X, Y, Z)
- The Cartesian coordinates of the 
Luminaire
MH
- The mounting height of the 
Luminaire
Orientation
- The orientation of the 
Luminaire 
based on 0° as defined in the 
Luminaire Schedule Editor
for the 
Symbol
Tilt
- The angle of tilt with 0° being straight down (in the negative Z-axis) of the 
Luminaire
Aim (X, Y, Z)
- The Cartesian coordinates of the aiming point of the 
Luminaire
Once placed, the object can be modified in many ways. See Working 
With Text-Based Objects
for information about formatting headers.
Visual has default settings of common content. The default may differ on any one computer based on user choices; see Saving 
Templates and Defaults
.
C# TIFF: How to Reorder, Rearrange & Sort TIFF Pages Using C# Code
Reorder, Rearrange and Sort TIFF Document Pages in C#.NET Application. C# TIFF Page Sorting Overview. Reorder TIFF Pages in C#.NET Application.
move pages within pdf; pdf move pages
C# PDF: C# Code to Process PDF Document Page Using C#.NET PDF
just following attached links. C# PDF: Add, Delete, Reorder PDF Pages Using C#.NET, C# PDF: Merge or Split PDF Files Using C#.NET.
reorder pdf pages; pdf page order reverse
11.. Po)er (enit, tac
Power Density Statistics
shows a table with data about each zone relaying area, total power, and the resulting power density to justify or verify compliance to various requirements.
To place a 
Power Density Statistics 
table on a Page, click the
Power Density
Statistics 
button on the 
Insert
tab  of the 
Print Editor Ribbonbar
.
Power Density Statistics
is placed by left-clicking the mouse in the desired
location as described in Placing 
Objects
.
See Working 
with Text-Based Objects
for information on editing text content.
See Working 
With Tabular Objects
for information on formatting tables as well as
choosing columns to display.
The available columns for 
Power Density Statistics 
are:
Description
- The name given to each 
Power Density Zone
in the 
Design Environment
Luminaires
- The number of Luminaires associated to the zone
Total Watts
- The total number of Watts (power) associated to the zone, based on the defined Watts in the 
Luminaire Schedule Editor
Area
- The area of the zone, based on the system units of feet or meters
Density
- The resulting Watts per unit area (W/ft² or W/m²) for the zone equalling [Total Watts]/[Area]
Once placed, the object can be modified in many ways. See Working 
With Text-Based Objects
for information about formatting headers.
Visual has default settings of common content. The default may differ on any one computer based on user choices; see Saving 
Templates and Defaults
.
VB.NET PowerPoint: Sort and Reorder PowerPoint Slides by Using VB.
Sort and Reorder PowerPoint Slides Range with VB amount of robust PPT slides/pages editing methods powerful & profession imaging controls, PDF document, image
rearrange pdf pages in reader; how to move pages around in pdf file
VB.NET PDF: Create PDF Document Viewer in C#.NET for Document
Support navigating to the previous or next page of the PDF document; Able to insert, delete or reorder PDF document page in VB.NET document viewer;
move pages in a pdf file; rearrange pages in pdf file
11..& tac
Light Level Statistics
(
Statistics
) summarize performance metrics for all 
Calculation Zones
placed in the model
Statistics
only applies to lighting metrics. 
Lighting Power Density
is
summarized in 
Power 
Density Statistics
placed separately.
To place a 
Statistics 
table on a Page, click the
Statistics 
button on the 
Insert
tab  of
the 
Print Editor Ribbonbar
.
Statistics
is placed by left-clicking the mouse in the desired location as described in
Placing Objects
.
See Working 
with Text-Based Objects
for information on editing text content.
See Working 
With Tabular Objects
for information on formatting tables as well as
choosing columns to display.
The available columns for 
Statistics 
are:
Description
- The name given to each 
Calculation Zone
in the 
Design Environment
Symbol - the graphical symbol associated to the zone
Avg
- the average of all values in the zone
Max
- the maximum value in the zone
Min
- the minimum value in the zone
Max/Min - the maximum value in the zone divided by the minimum value in the zone
Avg/Min - the average of all the values in the zone divided by the minimum value in the zone
Avg/Max
- deprecated; the average of all values in the zone divided by the maximum value in the zone
Min/Max
- deprecated; the minimum value in the zone divided by the maximum value in the zone
Min/Avg
- deprecated; the minimum value in the zone divided by the average of all values in the zone
Max/Avg
- deprecated; the maximum value in the zone divided by the average of all values in the zone
UG
Uniformity Gradient, which is the highest value of all the local changes in lighting quantity between adjacent points in the grid
CV
Coefficient of Variance, which is an advanced statistical calculation defined as the standard deviation divided by the mean (average) of all points
NOTE: units will change as necessary depending on the 
Calculation 
Type
chosen. Some statistics (e.g. UG and CV for a luminance -based zone) become nonsense in some cases.
C# PDF Page Rotate Library: rotate PDF page permanently in C#.net
Enable batch changing PDF page orientation without other PDF reader control. PDF page, delete certain PDF page, reorder existing PDF pages and split
how to rearrange pdf pages reader; pdf reverse page order preview
VB.NET TIFF: Modify TIFF File by Adding, Deleting & Sort TIFF
Users can use it to reorder TIFF pages in ''' &ltsummary> ''' Sort TIFF document pages in designed powerful & profession imaging controls, PDF document, image
how to change page order in pdf document; reordering pdf pages
Once placed, the object can be modified in many ways. See Working 
With Text-Based Objects
for information about formatting headers.
Visual has default settings of common content. The default may differ on any one computer based on user choices; see Saving 
Templates and Defaults
.
VB.NET PDF: VB.NET Guide to Process PDF Document in .NET Project
It can be used to add or delete PDF document page(s), sort the order of PDF pages, add image to PDF document page and extract page(s) from PDF document in VB
move pdf pages online; change page order pdf reader
VB.NET TIFF: VB.NET Sample Code to Process & Manage TIFF Page
certain TIFF page, and sort & reorder TIFF pages in Process TIFF Pages Independently in VB.NET Code. powerful & profession imaging controls, PDF document, image
how to reorder pages in pdf online; pdf change page order online
11..- ur.ace chedue
Surface Schedules
summarize properties of all 
Solid Objects
in the model.
To place a 
Surface Schedule 
table on a Page, click the
Surface Schedule 
button
on the 
Insert
tab  of the 
Print Editor Ribbonbar
.
Surface Schedule 
is placed by left-clicking the mouse in the desired location as
described in Placing 
Objects
.
See Working 
with Text-Based Objects
for information on editing text content.
See Working 
With Tabular Objects
for information on formatting tables as well as
choosing columns to display.
The available columns for 
Surface Schedule 
are:
Name 
- the name given to each 
Solid Object
in the 
Design Environment
Reflectances 
- the "front" and "back" Reflectance assigned to each object
Normal
(X, Y, Z)
- the unit vector describing the normal of each object
Area 
- the square feet or meters of each object based on system units
Once placed, the object can be modified in many ways. See Working 
With Text-Based Objects
for information about formatting headers.
Visual has default settings of common content. The default may differ on any one computer based on user choices; see Saving 
Templates and Defaults
.
11../ 0ite oc1
Title Block
can be inserted on a Page to organize and illustrate project-related information.
To place a 
Title Block 
table on a Page, click the
Title Block 
button on the 
Insert
tab of the 
Print Editor Ribbonbar
. The top portion of the button places a 
Title
Block
.
Once the button is pressed, Visual inserts the
Title Block
based on the printable area
and margins returned by the Windows system information.
The 
Title Block
button is dual function; the lower portion of the button initiates the
Title Block Dialog
that shows saved 
Title Blocks
that can be inserted. Left-click
the desired thumbnail image and Visual inserts the 
Title Block
based on the printable
area and margins returned by the Windows system information.
Note that, once placed, the 
Title Block
cannot be moved or resized like other objects.
Today's date will be placed in the 
Title Block
. This can be edited if necessary.
Borders are formatted as described in Working 
With Tabular Objects
.
Editing text-based sub-objects in a 
Title Block
is similar to the method for other text-
based objects; the first left-click places focus on the object, and the second left-click
tells Visual to modify the text contents of the object. See Working With 
Text-Based
Objects
for detailed information.
Editing the main 
Title Block
text is slightly different in that a small editor appears to
edit the text without it being rotated. Multiple lines can be input. Click Accept
to close
the editor and apply the changes.
The image in the upper-right can be modified as described in Images
to present a
company logo or any graphical element.
Using the 
Title Block Dialog
, the user can select Keep All Titleblocks Synchronized
to make each text field the same on all sheets; i.e. "Designer" (or whatever the user
chooses for that field) is the same on all 
Pages
. This feature also removes automatic
Page numbering.
Using the 
Title Block Dialog
, the user can select Manage Titleblock Templates that
initiates a dialog to delete and rename saved 
Title Blocks
. See Saving 
Templates
and Defaults
.
Visual has default settings of common content. The default may differ on any one computer based on user choices; see Saving 
Templates and Defaults
.
11..2 Product
Products
provide a way to describe products in a detailed fashion using graphical and specification sheet information from the Acuity Brands Product Database. Consequently, this only applies to
Acuity products. "
Product
" refers to one of the elements related to a 
Luminaire Type
, and can vary depending on the context. It could be a graphic (JPG, BMP, PNG, etc) or a PDF. Or, by the
time we get around to updating the manual, it could be a QR code or something to tie in your Google Glass or alert the NSA you're planning to sell LEDs to Iran. 
Products
are a specific case of
inserting 
PDF
files.
To place a 
Product 
on a Page, click the
Products 
button on the 
Insert
tab  of the
Print Editor Ribbonbar
. The number in the red circle represents the number of
Products
available to insert.
The 
Product Dialog
will initiate below the button. Each 
Product
section contains a
graphic and a specification sheet PDF; either of these may be blank indicating there is
not an object of that type to place. As can be seen at right, the blue header is labeled
with the IES file name.
Left-click either object type to place it on a Page.
Clicking a graphic tells Visual to place an 
Image
as described in Images
with the file
(from the product database) pre-attached for placement.
11..3 4ie)
Views
are saved images from the 
Design Environment
as described in Saving 
Views
Views
are not 
Drawings
and are not to a scale.
To place a 
View 
on the Page, left-click one of the 
Views 
shown in the 
Views 
panel
on the 
Insert
tab  of the 
Print Editor Ribbonbar
.
The first 
View 
(in the upper-left) is always the current 
View 
in the 
Design
Environment
. If the desired 
View 
is not shown, scroll using the scrollbar on the right
or click the expand button to see all 
Views
. Left-click the desired 
View
.
Clicking a 
View 
tells Visual to place an 
Image
as described in Images
with the related
graphic file of the 
View 
pre-attached for placement.
Once placed, a 
View 
can be 
Cropped
if desired. Select
the 
View 
to be 
Cropped
.
Click the 
Crop
button in the 
Properties
tab  of the 
Print Editor Ribbonbar
and
select 
Crop View 
from the drop down menu.
Left-click-drag a window that defines the area to remain after the 
Crop
. Release the
left mouse button and Visual automatically applies the changes and ends the
command.
Documents you may be interested
Documents you may be interested