c# view pdf web browser : Copy pdf page to powerpoint control Library system azure .net asp.net console asc_360_usbcommissioning3-part1007

Using WinSCP to Transfer the License
Net-Net OS-E Release 3.6
Creating Net-Net OS-E USB Installation Sticks
1-31
The image below illustrates the WinSCP login window. 
Perform the following steps:
1.
At the Hostname field, enter the IP address that you assigned to the management 
interface at the OS-Esystem. Port 22 is the default port number for SSH sessions.
2.
At the Username and Password  fields, type root for the username and sips for the 
password. 
3.
At the Environment menu, select SCP/Shell and select /bin/bash from the 
pull-down menu, as illustrated in the image below. Leave all other fields at their 
default settings. 
Proprietary & Confidential
Copy pdf page to powerpoint - control Library system:C# PDF Page Extract Library: copy, paste, cut PDF pages in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use C# Code to Extract PDF Pages, Copy Pages from One PDF File and Paste into Others
www.rasteredge.com
Copy pdf page to powerpoint - control Library system:VB.NET PDF Page Extract Library: copy, paste, cut PDF pages in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Detailed VB.NET Guide for Extracting Pages from Microsoft PDF Doc
www.rasteredge.com
Using WinSCP to Transfer the License
Net-Net OS-E Release 3.6
USB Creation and Commissioning Instructions
1-32
4.
Click Login . A series of progress message will appear as the connection is 
established.
5.
From the left pane, browse and locate the license file, then drag the license to the 
cxc/license directory, as illustrated in the image below . In this example, the file is 
copied from the c:\license directory to the cxc/license directory OS-E. 
6.
Once the license file is present in the cxc/license folder, you will need to do one of 
the follow tasks for the OS-E license to take effect:
• Perform a physical restart of the OS-E system, or
• From a CLI session to the device, execute the license apply action, as 
follows:
NNOS-E> license apply /cxc/license/
84420g9a-da13-3007-8853-z00a7a4d771d.xml
Success!
NNOS-E> show licenses
name: LICENSE for Company.com
description: LICENSE for Company.com
key: 84420g9a-da13-3007-8853-z00a7a4d771d
expires:
file: 84420g9a-da13-3007-8853-z00a7a4d771d.xml
Proprietary & Confidential
control Library system:C# PowerPoint - Extract or Copy PowerPoint Pages from PowerPoint
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Excel, VB.NET Extract/Copy PowerPoint Pages of PowerPoint Document in C# Project. C# DLLs: Extract PowerPoint Page.
www.rasteredge.com
control Library system:VB.NET PDF copy, paste image library: copy, paste, cut PDF images
VB.NET DLLs: Copy, Paste, Cut Image in PDF Page. using RasterEdge.Imaging.Basic; using RasterEdge.XDoc.PDF; VB.NET: Copy and Paste Image in PDF Page.
www.rasteredge.com
Net-Net OS-E Release 3.6
2-33
Chapter 2.  USB Commissioning on
Net-Net OS-E
This chapter provides information on commissioning OS-E software on supported 
third-party hardware devices from a USB stick.
• For Net-Net 2600 series systems, use the instructions in this chapter with the 
quick installation card provided with the hardware.
— Net-Net OS-E — Net-Net 2610/2620 Quick Installation
• For third-party platforms and servers listed in Chapter 2, ensure that you have 
followed the vendor-supplied instructions for initial setup, followed by any 
changes to BIOS and other important settings prior to OS-E commissioning. 
Net-Net OS-E Commissioning Steps
You will need to perform the steps in this section to properly boot and license new 
NN2600 series systems and third-party servers. 
Caution: 
Before starting, make sure that you have an operating terminal/
console attached to the system. Refer to Chapter 2 for the appropriate 
console serial port for the platform or third-party server you are 
commissioning. Perform any pre-installation tasks that may involve 
insertion and removal of the USB stick prior to beginning this sequence 
of steps. 
If you are installing IBM X3550 or X3650 servers, see Chapter 2 for 
information on initializing RAID drives in the event that you have new 
factory servers delivered with uninitialized RAID configurations. 
Proprietary & Confidential
control Library system:C# PDF copy, paste image Library: copy, paste, cut PDF images in
cutting. C#.NET Project DLLs: Copy, Paste, Cut Image in PDF Page. In C#.NET Demo Code: Copy and Paste Image in PDF Page in C#.NET. This C#
www.rasteredge.com
control Library system:VB.NET PDF Image Extract Library: Select, copy, paste PDF images
Extract all images from whole PDF or a specified PDF page in VB.NET. Capture VB.NET : Select An Image from PDF Page by Position. Sample
www.rasteredge.com
Net-Net OS-E Commissioning Steps
Net-Net OS-E Release 3.6
USB Creation and Commissioning Instructions
2-34
1.
Insert the USB drive into one of the USB ports on the device you are commissioning. 
2.
Restart or reboot the platform or third-party server. 
Refer to the documentation supplied with the platform for specific information on 
restarting and rebooting the device. 
3.
The USB and disk lamps will blink during the boot-up process followed by a series 
of system messages. Press any key to continue, or perform the appropriate action 
below for specific hardware. 
• IBM X3550 and HS21  Press F12.
• Dell 1950 and 2950 — Press F11
• Dell R220 — Press F11.
4.
When the GNU GRUB window appears, you will have the opportunity to select the 
port where your console device is connected. If you made the correct selection when 
you originally created the USB stick with the BMC (covered in Chapter 1), simply 
wait 10 seconds for the installation to begin. If you need to make a selection that is 
now different, follow the instructions on the menu to direct management output to the 
desired console port. 
GNU GRUB  version 0.97  (639K lower / 1045376K upper memory)
+-------------------------------------------------------------+
Acme Packet USB Setup (Default) 
Acme Packet USB Setup (force VGA console)
Acme Packet USB Setup (force 1st serial Port @115200,n,8,1)
Acme Packet USB Setup (force 2nd serial port @115200,n,8,1)
+--------------------------------------------------------------+
Use the ^ and v keys to select which entry is highlighted.
Press enter to boot the selected OS, 'e' to edit the
commands before booting, or 'c' for a command-line.
The highlighted entry will be booted automatically in 10 seconds.
5.
If a stick needs to be removed because the system will not reboot after the initial 
installation, reinsert the stick into the system at any point during the following 
sequence.
Loading Stage 1.5…
Grub Loading Please Wait...
Press any key to continue
Press any key to continue
Proprietary & Confidential
control Library system:C# PDF Image Extract Library: Select, copy, paste PDF images in C#
C#: Select All Images from One PDF Page. C# programming sample for extracting all images from a specific PDF page. C#: Select An Image from PDF Page by Position.
www.rasteredge.com
control Library system:C# Create PDF from PowerPoint Library to convert pptx, ppt to PDF
ppt"; String outputFilePath = Program.RootPath + "\\" Output.pdf"; // Load a PowerPoint (.ppt, .pps zoomValue, The magnification of the original PDF page size
www.rasteredge.com
Net-Net OS-E Commissioning Steps
Net-Net OS-E Release 3.6
USB Commissioning on Net-Net OS-E
2-35
6.
Wait for the series of messages to complete over several minutes. 
7.
At the username: and password: prompts, press Enter at each prompt to bypass 
the login and to display the NNOS-E prompt. Later, you will be able to configure 
users with appropriate user names and passwords.
Acme Packet, Inc. 
Copyright (c) 2004-2009 Acme Packet, Inc.
username: <Enter>
password: <Enter>
Access granted since there are no configured users
Type 'config setup' to configure your system.
8.
Execute the show licenses command to display licensing information. The 
information includes the name, description, key, file name, and the expiration date 
of the license.
NNOS-E> show licenses
name: CUSTOMER ONE LICENSE
description: LICENSE FOR CUSTOMER ONE
key: 84420f9a-da13-4107-8833-d00b7d4d751d
expires: 
file: 84420f9a-da13-4107-8833-d00b7d4d751d.xml
If show licenses does not display any information, make sure that the USB stick is 
inserted and perform a restart warm .
9.
At the NNOS-E prompt, type umount usb to properly dismount the USB stick. 
Physically remove the USB stick from the USB port. This is now your utility USB 
device. Refer to Using the Rescue Utility USB for information.
10.
If the platform contains additional drives to be used for data (physical or a logical 
due to RAID) then they need to be added to the system before they can be used. 
To format and attach the first data drive to the system formatted with the XFS file 
system format, enter the following command:
>format data-1 xfs
Use data-2 if there is a second data driver to be formatted and added, and so on.
Note: 
If using a VGA console, you will presented with login  prompt. 
Type root and press Enter
Proprietary & Confidential
control Library system:VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
XDoc.PDF ›› VB.NET PDF: Delete PDF Page. using RasterEdge.Imaging.Basic; using RasterEdge.XDoc.PDF; How to VB.NET: Delete a Single PDF Page from PDF File.
www.rasteredge.com
control Library system:C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
Existing PDF Pages. Page: Replace PDF Pages. Page: Move Page Position. Page: Extract, Copy and Paste PDF Pages. Page: Rotate a
www.rasteredge.com
Using the Setup Script
Net-Net OS-E Release 3.6
USB Creation and Commissioning Instructions
2-36
If an existing data drive is being added to the system, for example when 
commissioning an existing system, use the OS-E add-device to attach drives.
Note that this only applies to data drives formatted from an existing OS-E system 
and not
an arbitrarily formatted drive. Ensure you specify the correct file-system 
type as what the drive was originally formatted.
To attach the first data drive to the system formatted with the XFS file system 
format, enter the following command:
>add-device data-1 xfs
11.
Configure the OS-E software for your network. Run the setup script to configure 
basic IP connectivity and services. See Using the Setup Script.
Using the Setup Script
An optional configuration setup script called cxc.setup is included with the OS-E 
software. After installing a new system, you can run the script directly from the 
NNOS-E> prompt, as shown in the example session below. 
The script presents a set of questions to help you with the initial system configuration. 
The information in the script includes the following:
• Local hostname
• IP interface names and addresses
• SSH and Web access
• Default route and any additional static routes per interface for remote 
management
• User-defined OS-E
Acme Packet OS-E systems have a minimum of two Ethernet interfaces. Any Ethernet 
interface on the system can be used for management traffic, however, Acme Packet 
recommends the use of eth1, as eth0 is reserved for fault-tolerant clustering with other 
OS-E systems. Management traffic is also supported on any interface that is carrying 
private or public network traffic. This means that it would be possible to use eth1 to 
carry SIP traffic and management traffic. 
Proprietary & Confidential
Creating a New USB Rescue Stick
Net-Net OS-E Release 3.6
USB Commissioning on Net-Net OS-E
2-37
CLI Session
NNOS-E> config setup 
set box\hostname: <name>
config box\interface: eth1
set box\interface eth1\ip a\ip-address: <ipAddress/mask>
config box\interface eth1\ip a\ssh (y or n)? y
config box\interface eth1\ip a\web (y or n)? y
config box\interface eth1\ip a\routing\route: <routeName>
set box\interface eth1\ip a\routing\route localGateway\gateway:
<ipAddress>
set box\cli\prompt: <newPrompt>
Do you want to commit this setup script (y or n) y
Do you want to update the startup configuration (y or n)? y
Creating a New USB Rescue Stick
The restore-stick-create full-backup action allows captures the current OS-E 
software and the operating system image and creates a new USB rescue stick. Acme 
Packet recommends that you use restore-stick-create full-backup to preserve the 
image prior to performing a system software upgrade, or whenever you have made 
significant and reliable changes to the system configuration. 
Perform the following steps:
1.
At the NNOS-E prompt, type umount usb
Ignore the warning about the USB stick not being mounted. 
2.
Remove the USB stick and wait at least five seconds before reinserting the stick. 
3.
Invoke the restore-stick-create full-backup action. The resulting USB is a boot 
device from which you can restart and restore the OS-E. 
4.
Remove the restore USB when the restore-stick-create action has completed. 
Note: 
The log event indicating that the operation has completed successfully 
appears while data is being written to the stick. DO NOT immediately remove 
the USB stick when you see this log event. Instead, issue the umount usb 
command again, and wait for it to complete. 
Note: 
PostgreSQL database, media recordings, system tar files(.gz) are not 
written to the restore stick with the restore-stick-create action. 
Proprietary & Confidential
Using the Rescue Utility USB
Net-Net OS-E Release 3.6
USB Creation and Commissioning Instructions
2-38
Using the Rescue Utility USB
To use the rescue utility USB, perform the following steps:
1.
Insert the rescue utility USB into one of the USB slots. 
2.
At the NNOS-E prompt, if available, enter restart cold to do a full restart. 
3.
The USB and disk lamps will blink during the boot-up process followed by a 
series of system messages. Press any key to continue, or perform the appropriate 
action below. On the 
• CXC-350 — Press the ESC key.
• Sun x4150 — Press F8.
• IBM X3650, X3550, X-3350 — Press F12.
• Dell 1950 and 2950 — Press F11
• Dell R220 — Press F11.
• IBM HS20 and HS21 — Press F12.
• Fugitsu Siemens RX200 S5  Press F12
• Fugitsu Siemens RX300 S4  Press F12
• ATCA MCLB0040 — Press F8
4.
The system enters utility mode and the following menu appears:
MAIN MENU
=========
Please select from the following menu below:
1) Save config, install to system drive, restore config
2) Expert mode
3) Debug mode
4) Reboot
Choice:
The choices (by number) are as follows:
Note: 
Use the restore-stick-create config-backup action to create a restore 
stick containing the current configuration file only. 
Proprietary & Confidential
Using the Rescue Utility USB
Net-Net OS-E Release 3.6
USB Commissioning on Net-Net OS-E
2-39
1). Save config, install to system drive, restore config
This function saves the current configuration file (cxc.cfg), license, and related 
files to the USB stick, reinstalls the OS-E software, and then restores the saved 
configuration files to the OS-E system. 
2). Expert mode  Displays the following menu:
EXPERT MENU
===========
Please select from the following menu below:
1) Do not format and install to partition 4
2) Commission only the system drive
3) Save configs, license, certs and secrets
4) Restore configs, license, certs and secrets
5) Decommission box (VERY dangerous)
q) Return to main menu
Choice:
See Using the Expert Mode.
3). Debug mode — Displays the debug menu. 
DEBUG MENU
==========
Please select from the following debug menu below:
1) Shell
2) Disable debug mode
3) Disk repair (fsck)
4) Filesystem repair (fsck --rebuild-tree)
5) Check for disk errors (bad blocks)
6) Mount drives (1st system drive - partition 3)
7) Mount drives (2nd system drive - partition 4)
8) Unmount all drives
9) Fix MBR on system drive (ie GRUB)
a) Set default GRUB boot title item
b) Make USB stick bootable
c) Make USB stick un-bootable
Caution: 
The selections in the debug menu are diagnostic functions and 
should only be used with assistance from Acme Packet Technical 
Support. 
Proprietary & Confidential
Using the Rescue Utility USB
Net-Net OS-E Release 3.6
USB Creation and Commissioning Instructions
2-40
q) Return to main menu
Choice:
4). Reboot  Performs a restart cold action.
Using the Expert Mode
The Expert mode provides utilities that allow you to recover from system failures 
where there is apparent damage to the software and configuration file, and where 
recovery is necessary to return the OS-E to normal operation. The Expert mode 
functions are provided below:
1.
Do not format and install to partition 3/4
With Release 3.5.0 and later, this function reinstalls the OS-E to partition 3 
(System 1) or partition 4 (System 2) on the system disk drive. Using partitions, 
you can install more than one release and use the set-chassis-config-boot action 
to select the system (and release) to run at system startup. No formatting of the 
system drive will occur under this function. 
2.
Commission only the system drive
If used in conjunction with the “Do not format and install to partition 3/4” option 
above, this function installs the OS-E software and leaves the current 
configuration file and licenses intact. See Net-Net OS-E Commissioning Steps. 
3.
Save configs, license, certs and secrets
This function saves the current configuration file(s), license, certificates, and 
secrets from the current partition to the USB rescue stick. Acme Packet 
recommends that you use this function on a frequent basis to create an up-to-date 
rescue stick. 
4.
Restore configs, licenses, certs, and secrets
Warning: 
If you did not choose the “Do not format and install to 
partition 3/4” option first, the system drive WILL BE formatted and all 
configuration and related data will be lost. 
Proprietary & Confidential
Documents you may be interested
Documents you may be interested