c# view pdf web browser : Cut pdf pages software application dll windows winforms azure web forms e108009-part1054

Configuring For Image Conversion
Working With Image and Video Conversions 4-11
4.3.3.1 extraRendition_definitions.hda File Structure
When defining additional rendition sets, the extraRendition_definitions.hda file 
should contain a header line and two section types.
Section Types
The extraRendition_definitions.hda file has two section types using the following 
format:
@section_type section_name
Section data
@end
The two section types are:
Properties Section
ResultSet Section
In the extraRendition_definitions.hda file, there is one properties section and multiple 
result set sections. All rendition sets are organized in result sets.
Comments are not allowed within a section of an HDA file. However, you can place 
comments in the HDA file before the first section, between sections, or after the last 
section.
Blank lines within a section of an HDA file are interpreted as a NULL value. Blank 
lines before the first section, between sections, or after the last section are ignored.
Properties Section
The properties section of the extraRendition_definitions.hda file defines the path to an 
external conversion application. In the default file, it also declares the values of Idoc 
Script variables defining conversion options used by the default rendition result sets.
Default Idoc Script variables in the properties section are used by the default rendition 
sets. They are not required for any additional rendition sets you define and are not 
discussed in this guide. Conversion options can be specified directly within the result 
sets. For more information on working with IdocScript, see the Idoc Script Reference 
Guide.
Result Set Sections
There are two types of result sets in the extraRendition_definitions.hda file, listed here 
in order of display in the file:
Rendition Result Sets
ExtensionFormatMap
Rendition result sets organize rendition sets and contain information about creating 
renditions. There can be many rendition result sets, in any order. They can be added, 
modified, or deleted, but each name must be unique.
The ExtensionFormatMap is an optional result set lists file extension/format pairs, so 
that Inbound Refinery can return the correct file format to Content Server for use 
internally. This is not a required set, as Inbound Refinery uses a different system to 
map extensions to mime types, but if this result set is defined, the mapping specified 
in it takes precedence.
Cut pdf pages - copy, paste, cut PDF pages in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use C# Code to Extract PDF Pages, Copy Pages from One PDF File and Paste into Others
extract pages from pdf document; combine pages of pdf documents into one
Cut pdf pages - VB.NET PDF Page Extract Library: copy, paste, cut PDF pages in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Detailed VB.NET Guide for Extracting Pages from Microsoft PDF Doc
extract one page from pdf file; extract pages from pdf file
Configuring For Image Conversion
4-12 Administrator's Guide for Conversion
4.3.3.2 Adding a Rendition Set
The simplest way to add a rendition set to the extraRendition_definitions.hda file is to 
copy an existing rendition result set and modify it. To successfully modify an existing 
set, you should be aware of basic set structure.
Modifications made to a component resource such as damconverter_
basedefinitions.hda will be over-written if Digital Asset Manager is updated to a 
newer version. Additional rendition sets should be added to the extraRendition_
definitions.hda file created in the IntradocDir/data/configuration/dam. Digital Asset 
Manager uses both files when running.
Rendition Result Set Structure
HDA files are ordered using simple name/value pairs, representing tabular data in an 
ASCII text format. The first line of a ResultSet section declares the set with the 
command @ResultSet, and then specifies the name of the set. The second line specifies 
the number of columns a table has, and the following lines name and populate the 
columns based on their order in the result set. Finally, the last line closes the result set 
with the command @end.
The first line of the rendition result set declares it as a result set by starting with 
@ResultSet, and the last line closes the set, with @end. The first line also gives the set a 
name. In this case, the name is ThumbnailOnly.
The name used should be descriptive, but spaces and other characters reserved for 
Idoc Script tags or illegal for use in URLs, such as spaces, cannot be used in rendition 
names.
The second line identifies how many columns are in the result set. In rendition result 
sets for Digital Asset Manager, there are 6 columns.
Each column has the following name and description:
Column Name
Column Description
extRenditionName
The name of the rendition displayed on the Rendition Information 
page.
Make sure that you do not use Primary or Alternate for rendition 
names. These terms are reserved for internal use by Content Server.
extEngine
The path to the conversion engine used. By default, this is expressed as 
an Idoc Script variable declared in the properties section of the 
extraRendition_definitions.hda file.
extType
How the rendition is being used.
Thumbnail: Used on the Thumbnail view of a search results page.
Preview: Used on the Rendition Information page.
Web: The web-viewable version of a content item. Displayed in 
the main content area when accessed by clicking the content ID or 
thumbnail from a search results page, or when clicking the 
web-viewable link on a content information page. Displayed in a 
new browser window when accessed by clicking the Preview 
image on a Rendition Information page. If no web rendition is 
defined the native file is used by Content Server as the 
web-viewable file.
Extra: Any rendition not defined as Thumbnail, Preview, or Web.
Rendition types may be combined. For example, by listing the type as 
web, preview, the rendition is used both as the web file and as the 
preview file.
VB.NET PDF copy, paste image library: copy, paste, cut PDF images
VB.NET PDF - Copy, Paste, Cut PDF Image in VB.NET. Copy, paste and cut PDF image while preview without adobe reader component installed.
export pages from pdf preview; delete pages of pdf
C# PDF copy, paste image Library: copy, paste, cut PDF images in
C#.NET PDF SDK - Copy, Paste, Cut PDF Image in C#.NET. C#.NET Demo Code: Cut Image in PDF Page in C#.NET. PDF image cutting is similar to image deleting.
copy pdf page to clipboard; deleting pages from pdf in reader
Configuring For Image Conversion
Working With Image and Video Conversions 4-13
For more information on working with .hda files, see the Working With Components 
guide.
To add a new rendition result set, perform these steps:
1.
Open the extraRendition_definitions.hda in a standard text editor.
2.
Copy and paste an existing rendition result set.
a.
Select a rendition result set to copy, starting at the @ResultSet line and ending 
at the @end line, and copy it.
b.
Position the cursor between any two existing rendition result sets in the 
extraRendition_definitions.hda file.
c.
Paste the rendition result set into the file.
Blank lines between result set sections are ignored. To help visually organize the 
extraRendition_definitions.hda file, you may want to insert a blank line before and 
after the new rendition result set.
3.
Change the name of the new rendition result set, listed next to @ResultSet. For 
example, @ResultSet NewName.
The name used should be descriptive, but spaces and other characters reserved for 
Idoc Script tags or illegal for use in URLs, such as spaces, cannot be used in 
rendition names.
4.
Change rendition information for each rendition you want to keep in the result set.
a.
Change the name of the rendition, listed in the extRenditionName column. 
Rendition names may have spaces.
b.
Change the type of the rendition, listed in the extType column. Each rendition 
can multiple types, for example, preview, web.
extSourceFile
The file path to the asset checked into for conversion expressed as Idoc 
Script.
extParameters
The options passed to the conversion engine defining how the source 
file is rendered. By default, this is expressed as Idoc Script variables 
declared in the properties section of the extraRendition_
definitions.hda file, but it can be expressed as a literal string.
<$infile$>: The name of the source file used to generate the 
rendition, expressed as Idoc Script.
<$outfile$>: The name of the rendered file. This is a required 
parameter, expressed as Idoc Script.
<$parameter_variable$>: The options used for rendering by the 
conversion application. In the provided rendition sets, these are 
expressed as Idoc Script variables, which are declared in the 
properties section of the extraRendition_definitions.hda file. They 
can also be expressed as a literal string of options used by your 
conversion application. For example, the literal string used in the 
damconverter_basedefinitions for the Web rendition is:
outputid=FI_GIF, graphicoutputdpi=72, 
graphicwidthlimit=250, graphicheightlimit=0
but it could also be expressed as the following variable:
<$ImageExport_BasicRenditions_Web$>
extDescription
The description for the rendition displayed on the Rendition 
Information page.
Column Name
Column Description
VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
Page: Delete Existing PDF Pages. |. Home ›› XDoc.PDF ›› VB.NET PDF: Delete PDF Page. How to VB.NET: Delete Consecutive Pages from PDF.
delete pages of pdf online; a pdf page cut
C# PDF Page Delete Library: remove PDF pages in C#.net, ASP.NET
Page: Delete Existing PDF Pages. Provide C# Users with Mature .NET PDF Document Manipulating Library for Deleting PDF Pages in C#.
extract one page from pdf online; delete page from pdf
Configuring For Image Conversion
4-14 Administrator's Guide for Conversion
c.
Change the conversion options for rendering, listed in the extParameters 
column. Conversion options are dependent on which third-party conversion 
application being used.
d.
Change the description of the rendition, listed in the extDescription column. 
The description can be anything, and is displayed on the Rendition 
Information page.
Do not change the <$InFilePath$> variable used in the extSouceFile column. 
This is required by .
5.
Delete any extraneous renditions in the result set.
6.
Save the extraRendition_definitions.hda file.
4.3.3.3 Enabling a Rendition Set
After a rendition set is added to the extraRendition_definitions.hda file, it must be 
made available as an option in the Image Rendition Set field on the Content Check In 
Form, using Configuration Manager.
To add the name of the rendition set as an option in Configuration Manager, perform 
these steps:
1.
Log in to Content Server. You must have administration rights.
2.
Click Admin Applets on the Administration tray. The Administration page is 
displayed
3.
Click Configuration Manager. The Configuration Manager applet opens.
4.
Verify the Information Fields tab is active, select the PackagedConversions 
information field and click Edit. The Edit Custom Info screen is displayed.
5.
Click Configure. The Configure Option List screen is displayed.
6.
Click Edit. The Option List screen is displayed.
7.
Add the name of the new result set as it is listed in the extraRendition_
definitions.hda file's packedConversion result set. Rendition sets can be listed in 
any order.
The name used in the extraRendition_definitions.hda file and the 
PackagedConversions option list must match. Spaces and other characters 
reserved for Idoc Script tags or illegal for use in URLs cannot be used.
8.
Click OK to close the Option List screen.
9.
Click OK to close the Configure Option List screen.
10.
Click OK to close the Edit Custom Info screen.
4.3.4 Working with XMP and EXIF Data
Most digital images have data associated with them by the hardware or software used 
to create them. For example, digital photographs have the date they were created and 
the camera used to create them associated with them, among other things. Digital files 
such as those created with Adobe Photoshop have a greater set of metadata associated 
with them. The metadata associated with digital photographs is called EXIF data, 
which stands for Exchangeable Image File Format. It is a subset of the type of data 
created by computer applications such as Adobe Photoshop. The application metadata 
is called XMP data, which stands for EXtensible Metadata Platform.
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Page: Insert PDF Pages. |. Home ›› XDoc.PDF ›› VB.NET PDF: Insert PDF Page. Add and Insert Multiple PDF Pages to PDF Document Using VB.
delete pages out of a pdf file; delete pages from pdf
C# PDF Page Insert Library: insert pages into PDF file in C#.net
Page: Insert PDF Pages. |. Home ›› XDoc.PDF ›› C# PDF: Insert PDF Page. Add and Insert Multiple PDF Pages to PDF Document Using C#.
cut pages from pdf preview; extract pages from pdf online tool
Configuring For Video Conversion
Working With Image and Video Conversions 4-15
By default, Inbound Refinery is now configured to send EXIF and XMP data to 
Content Server, where it is indexed and available for searching as text.
4.3.4.1 Searching XMP and EXIF Data in Content Server
By default, XMP schema and EXIF data are extracted by Inbound Refinery and passed 
to Content Server. Content Server then displays the data on the Image Data tab of a 
digital asset. If OracleTextSearch is installed and enabled, the data is indexed and 
available for searching through a full-text search. To enable searching on a specific 
criteria in the XMP or EXIF metadata, a placeholder field must be enabled on the 
Content Server user interface and the search collection must be rebuilt. Once done, 
users can search for content using the specific criteria in the data.
To enable an XMPor EXIF data field on the user interface and make the specific criteria 
available for searching, do these steps:
1.
On the Content Server, expand the Administration tray and click DAM 
Adminstration. The DAM Search Fields Administration page is displayed.
2.
Expand the section under the XMP Schema Categories that has the data field to 
enable on the user interface. For example, to search for digital images based on the 
date and time the image was take, expand the EXIF category.
3.
Find and enable the placeholder field to be used for searching. For example, in the 
EXIF catagory, scroll to the XMP Date Time Original and enable it.
4.
Click Update.
5.
Rebuild the search index. For information on rebuilding the search index, see the 
content server documentation.
4.3.4.2 Applying XMP and EXIF Data as Text Overlay to a Rendition
Once a placeholder field has been created and the metadata indexed, XMP and EXIF 
metadata can be used as a text overlay in a custom rendition. 
4.4 Configuring For Video Conversion
Digital Asset Manager requires a third-party conversion application to render video 
assets checked in to Content Server. Currently, Digital Asset Manager is designed to 
work with Telestream’s FlipFactory version 6.0 and 6.1 
(http://www.telestream.net/products/flipfactory.htm).
This section has the following topics:
"Installing FlipFactory" on page4-16
"Installing Digital Asset Manager Video Plug-ins" on page4-16
"Ensuring the JDOM Library is Installed for FlipFactory 6.0" on page4-17
"Sharing Directories with FlipFactory" on page4-17
"Setting the Conversion Engine Shared Directory Path" on page4-18
Note: Enabling a field in the user interface creates a placeholder field 
in content server and allows the information to be indexed and 
searched against. It does not modify database tables or allow 
information to be entered or modified in the field for storage in the 
database.
How to C#: Basic SDK Concept of XDoc.PDF for .NET
example, you may easily create, load, combine, and split PDF file(s), and add, create, insert, delete, re-order, copy, paste, cut, rotate, and save PDF page(s
delete page from pdf reader; copy pages from pdf to word
VB.NET PDF: Basic SDK Concept of XDoc.PDF
example, you may easily create, load, combine, and split PDF file(s), and add, create, insert, delete, re-order, copy, paste, cut, rotate, and save PDF page(s
extract pages from pdf acrobat; cut paste pdf pages
Configuring For Video Conversion
4-16 Administrator's Guide for Conversion
"Setting the Default Media Location" on page4-20
"Defining Video Rendition Sets" on page4-24
"Creating and Configuring Factories in FlipFactory" on page4-24
"Managing Video Conversion" on page4-27
"Enabling Plug-in Debugging Logs" on page4-29
4.4.1 Installing FlipFactory
If you do not already have an instance of FlipFactory installed, follow the instructions 
included with FlipFactory to install and set up the application to meet your 
requirements. FlipFactory must be installed on a Windows server.
4.4.2 Installing Digital Asset Manager Video Plug-ins
The monitor, transport, and notification plug-ins that Inbound Refinery uses to 
communicate with FlipFactory to convert videos are distributed in the 
idcFlipFactoryPlugin.zip file installed by the DAMConverter component. The 
idcFlipFactoryPlugin.zip file is located in the refinery 
IdcHomeDir/components/DAMConverter/VideoManagerFlipFactoryPlugin/ 
directory.
To install and configure the Digital Asset Manager plug-ins for FlipFactory, perform 
these steps:
1.
Open Services on the Windows server on which FlipFactory is installed.
2.
Select the Flip Engine service and then select Actions, Stop.
3.
Select the idcFlipFactoryPlugin.zip located in the refinery 
IdcHomeDir/components/DAMConverter/VideoManagerFlipFactoryPlugin/ 
directory, and extract the file to the FlipFactory installation directory. For example: 
C:/Telestream/FlipFactory/. Two directories are extracted to the following 
locations:
/<FlipFactory_install_dir>/idcTools/
/<FlipFactory_install_dir>/Plugins/
Cautions: FlipFactory installation will fail if installing on a computer 
with an instance of Microsoft SQL Server 2000 or lower. Ensure that 
SQL Server 2000 or lower is not installed on the computer on which 
you are installing FlipFactory.
FlipFactory requires QuickTime to be installed for QuickTime 
renditions to be made. Review the FlipFactory documentation for 
information regarding obtaining and integrating the proper 
QuickTime version for use with the specific version of FlipFactory 
your are using, either 6.0 or 6.1. Also, visit Telestream’s site at 
http://www.telestream.net/ for the latest information relating to 
FlipFactory.
Due to the demand on computer resources required for rendering 
video assets, it is recommended that FlipFactory and Inbound 
Refinery be installed on separate server-class machines. For ease of 
access, it is also recommended that both servers have a duplicate user 
list of administrators.
Configuring For Video Conversion
Working With Image and Video Conversions 4-17
4.4.3 Ensuring the JDOM Library is Installed for FlipFactory 6.0
FlipFactory 6.0 requires the JDOM library jdom.jar to be installed in the /<FlipFactory_
install_dir>/Jars/ directory. After installing the Digital Asset Manager Video plug-ins, 
navigate to the /<FlipFactory_install_dir>/Jars/ directory and ensure that the jdom.jar 
file is there. If is not there, download the latest API from http://www.jdom.org/ and 
copy only the jdom.jar file to the /<FlipFactory_install_dir>/Jars/ directory and restart 
FlipFactory.
This is not necessary for FlipFactory 6.1.
4.4.4 Sharing Directories with FlipFactory
To convert videos, each implementation of Digital Asset Manager must have a staging 
directory and a watched directory on a file system shared with FlipFactory. The 
staging and watched directory can be the same directory. For Digital Asset Manager to 
work properly, a subdirectory in each watched directory must have the same name as 
the rendition set in Digital Asset Manager, which in turn must have the same name as 
the factory created in FlipFactory.
Additionally, there must be an “in” directory and an “out” directory within each 
subdirectory of the watched folder.
To create the required directories, perform these steps:
1.
Establish a shared file system that can be accessed by both FlipFactory and 
Inbound Refinery. For best results, set up the shared directories on the system that 
has FlipFactory installed.
2.
Create a staging directory. It can be named anything. For example, Video_Staging.
3.
Create a watched directory. It can be named anything. For example, Video_Watch. 
A single shared directory can be used for both the watched and staging directory
4.
Open the watched directory and create a directory for each rendition set defined 
in Digital Asset Manager. The name of the directory must equal the name of the 
rendition set as defined by editing the VideoRenditions custom metadata field in 
Configuration Manager.
Caution: To ensure that all files are extracted to the correct place, 
keep the directory structure when extracting the 
idcFlipFactoryPlugin.zip file to the FlipFactory installation directory. 
The full directory structures are:
/<FlipFactory_install_dir>/idcTools/jars/
/<FlipFactory_install_
dir>/Plugins/com/stellent/refinery/ff/impl
Cautions: If multiple factories point to the same “in” directory, the 
input file will be rendered by whichever factory receives notification 
first. As different factories may have different parameters, unexpected 
results may occur. For conversion to work properly and provide the 
expected results for each rendition, each factory created in FlipFactory 
should point to its own unique “in” directory.
The path to the shared directories must not contain spaces.
Configuring For Video Conversion
4-18 Administrator's Guide for Conversion
5.
Open each directory in the watched directory and create two subdirectories, one 
named in, the other out. For example:
/<Video_Watch_dir>/MediumBandwidth/in
/<Video_Watch_dir>/MediumBandwidth/out
4.4.5 Setting the Conversion Engine Shared Directory Path
Once the staging and watched directories are created, both Inbound Refinery and 
FlipFactory must know where to find them. Inbound Refinery must be able to place a 
copy of the asset in the staging directory and retrieve the renditions from the watched 
directory when rendering is complete. Inbound Refinery must also post an XML file 
requesting the file be rendered in the watched directory, telling FlipFactory where to 
find the asset and where to return the renditions, in a syntax that FlipFactory can 
understand. For best results, set up the shared directories on the system that has 
FlipFactory installed.
Setting the Shared Directory Path In Inbound Refinery
To set the shared directory path in Inbound Refinery, perform these steps:
1.
Open the intradoc.cfg file for each Inbound Refinery connection accessing the 
shared directories in a standard text editor. The intradoc.cfg file is located in the 
connection directory of an Inbound Refinery installation. For example:
DomainDir/ucm/ibr/bin/intradoc.cfg
2.
Add the variable VideoStagingDir and set it equal to the path of the staging 
directory shared with FlipFactory. For example:
VideoStagingDir=\\\\NetworkIdentity/Video_Staging/
The path can be a local, mapped, or a Universal Naming Convention (UNC) path. 
The backslash is an escape character in Java, so any path using a backslash must 
be escaped using two backslashes. For example, the path 
\\NetworkIdentity/Video_Staging becomes \\\\NetworkIdentity/Video_
Staging.
3.
Add the variable RefineryFlipFactoryWatchRootDir and set it equal to the path to 
the watched directory shared with FlipFactory. For example:
RefineryFlipFactoryWatchRootDir=\\\\NetworkIdentity/Video_Watch.
4.
Save changes and close the intradoc.cfg file.
Directory Configuration
When both applications are running on a Windows platform, the VideoStagingDir and 
RefineryFlipFactoryWatchRootDir can have the same value, because the syntax for 
Caution: For conversion to work properly, the names of the watched 
subdirectories, the Digital Asset Manager rendition sets, and the 
FlipFactory factories must be the same. Paths to the shared directories 
should not contain spaces.
Caution: The path to the shared directories must not contain spaces.
Configuring For Video Conversion
Working With Image and Video Conversions 4-19
accessing the directories and posting the directory locations in the XML request can be 
identical.
If Inbound Refinery is running on a UNIX platform, however, the paths to the shared 
directory may require a different syntax for accessing the directory than for posting 
the directory location in the XML request in a way that FlipFactory, running on a 
Windows platform, can understand.
The following additional variables are added to the Inbound Refinery connection 
intradoc.cfg file to provide context for Inbound Refinery to accurately post a file path 
that FlipFactory can understand.
VideoStagingDirFactoryContext
RefineryFlipFactoryWatchRootDirFactoryContext
For example, if a staging directory is created on a FlipFactory instance at 
\\\\NetworkIdentity/Video_Staging/, and mounted on the UNIX Inbound Refinery 
machine as /mnt/Video_Staging, then the following would be true:
VideoStagingDir=/mnt/Video_Staging
VideoStagingDirFactoryContext=\\\\NetworkIdentity/Video_Staging/
To add the additional multi-platform support variables to the intradoc.cfg file, 
perform these steps:
1.
Open the intradoc.cfg file for each Inbound Refinery connection accessing the 
shared directories in a standard text editor. The intradoc.cfg file is located in the 
connection directory of an Inbound Refinery installation. For example:
DomainDir/ucm/ibr/bin/intradoc.cfg
2.
Add the variable VideoStagingDirFactoryContext and set it equal to the path of 
the staging directory from the FlipFactory context. For example:
VideoStagingDirFactoryContext=\\\\NetworkIdentity/Video_Staging/
3.
Add the variable RefineryFlipFactoryWatchRootDirFactoryContext and set it 
equal to the path to the watched directory from the FlipFactory context. For 
example:
RefineryFlipFactoryWatchRootDirFactoryContext=
\\\\NetworkIdentity/Video_Watch
4.
Save changes and close the intradoc.cfg file.
Setting the Shared Directory Path in FlipFactory
The watched directory is defined in FlipFactory using the Oracle IBR monitor plug-in 
each time a factory is created. See the section "Installing Digital Asset Manager Video 
Plug-ins" on page4-16 for more information.
The staging directory does not need to be explicitly defined in FlipFactory.
Note: For FlipFactory to access a shared directory on a UNIX 
platform, you may need to configure the Flip Engine service on the 
FlipFactory server to be run by particular user. For more information, 
see the documentation that came with FlipFactory.
Configuring For Video Conversion
4-20 Administrator's Guide for Conversion
4.4.6 Setting the Default Media Location
So that both Inbound Refinery and Content Server knows what to do with video 
renditions once they are returned from FlipFactory, you must configure where you 
want video renditions placed. Video renditons can be placed in a variety of locations, 
depending on your business need. For example, they can be returned to the Content 
Server web layout directory, placed on a file system for access outside of Content 
Server, or sent to a streaming server.
This section covers the following topics:
"Configuring Default File Placement Locations" on page20
"Configuring Specific File Placement Locations" on page22
4.4.6.1 Configuring Default File Placement Locations
For Digital Asset Manager to work, Inbound Refinery must know what to do with a 
submitted asset and its renditions, and Content Server must know how to access them. 
A default location for assets must be set in the configuration files of both Inbound 
Refinery and Content Server. Additionally, a default URL root must be set in the 
configuration file for Content Server.
To set the default file placement locations, do the following steps:
1.
Open the intradoc.cfg file for each Inbound Refinery connection accessing the 
shared directories in a standard text editor. The intradoc.cfg file is located in the 
connection directory of an Inbound Refinery installation. For example:
DomainDir/ucm/ibr/bin/intradoc.cfg
2.
Add the variable DefaultMediaPhysicalRoot equal to the default location you 
want video renditions placed. Because Inbound Refinery may be converting for 
several Content Servers, the agent name of the Content Server must be appended 
to the variable. For example:
DefaultMediaPhysicalRoot-AgentName=\\\\NetworkIdentity/contentserver/weblayout/
Note: If you are planning to stream rendered videos, you must 
install and properly configure a supported media server based on the 
instructions that came with your media server, and set your 
conversion application to deliver the correct streaming format. 
Currently Digital Asset Manager supports Darwin Streaming Server 
(QuickTime), Helix Streaming Server (HelixMedia), and Windows 
Media Server
Note: Both Content Server and Inbound Refinery must have physical 
access to the placement locations.
Documents you may be interested
Documents you may be interested