1756-6.5.3 - December 1999
PLC-5C to Logix5550 Controller: Scheduled Communications
8-9
Configure the Consumer 
Logix5550 Controller
In order to test the application you must configure the Logix 5550 controller 
as a consumer, add the producer to the I/O configuration of the consumer, 
and create a consumed tag to receive the data.
Perform the following steps to create the consumer:
1. Open the RSLogix5000 software.
2. From the File menu, select New. The New Controller window will 
appear.
3. Enter an appropriate Name for the Controller (e.g., 
“Consumer_from_PLC5”).
4. Select the correct Chassis Type and Slot Number of the Logix5550 
controller, and the folder where you want to save the file (Create In). 
Then click on OK.
You will now add the producer PLC-5C to the consumer’s I/O 
configuration. This involves several steps. First, you must add the 
consumer’s local 1756-CNB module to its I/O configuration. Then you add 
the PLC-5C as a “child” of the local 1756-CNB module.
Extract page from pdf online - application Library tool:C# PDF Page Extract Library: copy, paste, cut PDF pages in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use C# Code to Extract PDF Pages, Copy Pages from One PDF File and Paste into Others
www.rasteredge.com
Extract page from pdf online - application Library tool:VB.NET PDF Page Extract Library: copy, paste, cut PDF pages in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Detailed VB.NET Guide for Extracting Pages from Microsoft PDF Doc
www.rasteredge.com
1756-6.5.3 - December 1999
8-10
PLC-5C to Logix5550 Controller: Scheduled Communications
Add the Producer to the I/O Configuration
I/O configuration is done using the project window on the left side of the 
screen.
1. Right-click on the I/O Configuration folder in the project window and 
select New Module from the pop-up window that appears.
The Select Module Type window will appear:
2. Select the 1756-CNB/B or 1756-CNBR/B module and click on OK.
application Library tool:C# PDF Image Extract Library: Select, copy, paste PDF images in C#
framework. C# users are able to extract image from PDF document page and get image information for indexing and accessing. C#
www.rasteredge.com
application Library tool:C# PDF Text Extract Library: extract text content from PDF file in
Feel Free to Extract Text from PDF Page, Page Region or Advanced Visual Studio .NET PDF edit SDK, built on .NET framework 2.0 and compatible with Windows
www.rasteredge.com
1756-6.5.3 - December 1999
PLC-5C to Logix5550 Controller: Scheduled Communications
8-11
The Module Properties window will appear.
3. Enter the following parameters:
4. Click on Finish to accept the configuration of the 1756-CNB module. 
The Local_CNB module will appear indented under the I/O 
Configuration folder.
5. Right-click on the Local_CNB module and select New Module.
Name
Local_CNB
Slot
1
Electronic Keying
Compatible Module
application Library tool:VB.NET PDF Image Extract Library: Select, copy, paste PDF images
Online source codes for quick evaluation in VB.NET class. By using RsterEdge XDoc PDF SDK for .NET, VB.NET users are able to extract image from PDF page or file
www.rasteredge.com
application Library tool:VB.NET PDF Text Extract Library: extract text content from PDF
PDF Add-On, developers are able to extract target text content from source PDF document and This page will supply users with tutorial for extracting text
www.rasteredge.com
1756-6.5.3 - December 1999
8-12
PLC-5C to Logix5550 Controller: Scheduled Communications
The Select Module Type window will appear.
6. Select the 1785-PLC5C module and click on OK.
The Module Properties window will appear:
7. Enter the following parameters:
8. Click on the Finish button to accept the configuration.
Name
Producer
Node
11
application Library tool:C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
Create PDF Online. Convert PDF Online. WPF PDF Viewer. View PDF in Page: Replace PDF Pages. Page: Move Page Position. Page: Extract, Copy and Paste PDF Pages.
www.rasteredge.com
application Library tool:C# PDF Page Insert Library: insert pages into PDF file in C#.net
Ability to add PDF page number in preview. Offer PDF page break inserting function. Free components and online source codes for .NET framework 2.0+.
www.rasteredge.com
1756-6.5.3 - December 1999
PLC-5C to Logix5550 Controller: Scheduled Communications
8-13
The Producer PLC5C will now appear indented under the local 
1756-CNB in the I/O Configuration folder.
Create the Consumer Tags
The consumer tags are created using the project window on the left side of 
the screen. To consume scheduled I/O, you have to create a User-Defined 
data type.
1. Right-click on the User-Defined folder under Data Types and select 
New Data Type.
See Appendix B for additional 
information on consumer tags.
application Library tool:VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
Online source codes for quick evaluation in VB.NET class. If you are looking for a solution to conveniently delete one page from your PDF document, you can use
www.rasteredge.com
application Library tool:VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
Page: Replace PDF Pages. Page: Move Page Position. Page: Copy, Paste PDF Pages. Page: Rotate a PDF Page. PDF Read. Text: Extract Text from PDF. Text: Search Text
www.rasteredge.com
1756-6.5.3 - December 1999
8-14
PLC-5C to Logix5550 Controller: Scheduled Communications
The Data Type configuration window will appear:
2. Enter the following Data Type parameters:
3. Click on OK.
The new data type will appear under the User-Defined folder.
Name
Consumed_data
Members
Name
Data Type
Style
Consumed_1
DINT
Decimal
PLC5_data
INT[2]
Decimal
See Appendix B and the Logix5550 Controller User Manual, publication 
1756-6.5.12, for more information on creating consumed tags.
1756-6.5.3 - December 1999
PLC-5C to Logix5550 Controller: Scheduled Communications
8-15
You must now configure the consumed tags under the controller scope.
4. Double-click on Controller Tags in the project folder.
The Controller Tags window will appear.
5. Select the Edit Tags tab and create the following tag:
6. Right-click on the new PLC5_data tag.
Tag Name
Type
PLC5_data
Consumed_data
1756-6.5.3 - December 1999
8-16
PLC-5C to Logix5550 Controller: Scheduled Communications
The following pop-up window will appear.
7. Select Edit Tag Properties.
The New Tag configuration window will appear:
8. Enter the following parameters:
Name
PLC5_data
Tag Type
Consumed
Controller
PRODUCER
Remote Instance
1
(1)
(1)
The Remote Instance must match the Message Number assigned by 
RSNetWorx for ControlNet.
Data Type
Consumed_data
RPI
5ms
(2)
(2)
Remember that the RPI cannot be faster than the NUT. See page 1-7.
1756-6.5.3 - December 1999
PLC-5C to Logix5550 Controller: Scheduled Communications
8-17
9. Click on OK to save the tag configuration.
10.Save the RSLogix5000 program.
Download the Logix5550 Program
(1)
You do not need any ladder logic in the Consumer program. The program 
can consist of a single “End” rung.
1. Click on the Communications menu and select Who Active.
2. The Who Active window will appear (Your window may look different 
depending upon the drivers and other devices you have installed).
3. Drill down the tree through the ControlNet driver and the 1756-CNB 
module at node 1 to the controller in slot 0.
4. Highlight the controller and click on the Download button.
5. Minimize RSLogix5000.
For two-way communication you can also configure a produced tag for the 
Logix5550 controller at this time. See chapter 6 for details.
(1)
This example uses RSLogix5000 version 2.25. See Appendix D if you are using version 2.10 or earlier.
1756-6.5.3 - December 1999
8-18
PLC-5C to Logix5550 Controller: Scheduled Communications
Create the Producer 
Application
Perform the following steps to create the PLC-5C producer application:
1. Start the RSLogix5 software.
2. From the File menu, select New. The Select Processor Type window will 
appear.
3. Enter the following information and click on OK.
You will receive the following prompt:
4. Click on the Browse button and select the ControlNet Project file created 
in RSNetWorx for ControlNet (e.g., “Sched_PLC_to_Logix5550”).
5. Set the ControlNet Node to 11.
6. Click on OK.
In this field
Select
Processor Name
PRODUCER
Platform
ControlNet
Processor
(Enter your processor type)
Series
(Enter your processor’s series)
(1)
(1)
F series is recommended but not required.
Revision
(Enter revision letter)
Driver
AB_KTC-1
Processor Node
11
Documents you may be interested