Apollo 8p Hardware Manual
Front Panel 
11
(2) Preamp Gain & Channel Select Knob
This rotary encoder with integrated switch serves three functions. Each function is 
detailed below.
Rotate – Rotating the knob adjusts the preamp gain for the selected input channel.
Press – Pressing the knob selects which preamp channel (1 – 8) is adjusted by the front 
panel preamp controls.
Press+Hold – When a Unison plug-in is active in the channel’s dedicated Unison insert 
within the Console application, pressing and holding the knob enters/exits Unison Gain 
Stage Mode.
Each of the three functions above is explained in greater detail below.
Preamp Gain
The preamp gain of analog inputs 1 – 8 is adjusted with the rotary control. The channel 
to be adjusted is set with the Channel Select (press) function. The input to be adjusted 
(Mic, Line, or Hi-Z) is determined by the state of the channel’s Mic/Line switch (#4) or 
Hi-Z input (if connected).
Rotating the knob clockwise increases the preamp gain for the selected channel. The 
available gain range for preamp channels is 10 dB to 65 dB for the Mic, Line, and Hi-Z 
inputs.
More than one full revolution is needed to move through the available range. This feature 
increases the control resolution for more precise preamp gain adjustments.
Tip: To adjust signal levels for inputs 9 – 16, use the output level controls of de-
vices connected to those inputs. 
Line Input Gain Bypass
By default, line inputs 1 – 8 are routed through the channel’s preamp so the line input 
level can be adjusted with the Gain knob. However, line inputs 1 – 8 can be individually 
set to completely bypass the channel’s preamp circuitry and instead be routed directly to 
the channel’s A/D converter at a fixed reference level. This feature is set with the LINE 
INPUT GAIN menu in the Hardware panel within the Console Settings window.
Tip: This feature routes the preamp channel’s line input signal directly into the 
A/D converter for the purest path when additional gain is not needed (for example, 
when connecting external mic preamps to preamp channel line inputs).
When the channel’s LINE INPUT GAIN menu is set to BYPASS in Console Settings:
•  The Preamp Gain Indicator ring (#3) for the channel is solid green
•  When the Gain knob (#2) is rotated, the ring flashes to indicate that no gain 
adjustment is occurring
•  If a Unison plug-in is in the channel’s dedicated Unison insert in Console, the 
Unison plug-in is bypassed
Delete pages out of a pdf file - control application system:C# PDF Page Extract Library: copy, paste, cut PDF pages in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use C# Code to Extract PDF Pages, Copy Pages from One PDF File and Paste into Others
www.rasteredge.com
Delete pages out of a pdf file - control application system:VB.NET PDF Page Extract Library: copy, paste, cut PDF pages in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Detailed VB.NET Guide for Extracting Pages from Microsoft PDF Doc
www.rasteredge.com
Apollo 8p Hardware Manual
Front Panel 
12
Channel Select
Pressing the Preamp Knob changes the currently selected preamp channel, which 
determines which input (1 – 8) is adjusted by the front panel preamp controls. A 
preamp channel is selected for adjustment when its Channel Select Indicator (#11) is 
illuminated. 
Each time the knob is pressed, the selected channel increments to the next channel. If 
stereo linking is active, the stereo pairs are selected.
Gain Stage Mode
Gain Stage Mode is activated by pressing and holding the Preamp knob for two seconds 
when a Unison plug-in is active in the channel’s dedicated Unison insert within the 
Console application. When Gain Stage Mode is active, pressing and holding the knob for 
two seconds deactivates Gain Stage Mode.
Gain Stage Mode is active when the Channel Select Indicator (#11) for the currently 
selected channel is flashing. In this state, pressing the Gain knob cycles through the 
available gain parameters within the Unison plug-in so each gain stage in the plug-in can 
be adjusted from the front panel. 
Note: For complete details about Gain Stage Mode, see the Unison chapter within 
the Apollo Software Manual
(3) Preamp Gain Level & State Indicator
Preamp Gain Level Indicator
The amount of preamp gain for the currently selected channel is indicated by the 
illuminated ring surrounding the Preamp knob. 
The ring indicates relative gain levels and is not calibrated to indicate any specific dB 
value. However, precise numerical dB gain values for the preamps are displayed within 
the Console application.
Note: If the ring is at maximum and flashes when the Preamp knob is rotated, the 
channel’s LINE input is selected and LINE INPUT GAIN is set to BYPASS. See 
Line Input Gain Bypass for additional details.  
control application system:VB.NET PDF delete text library: delete, remove text from PDF file
Delete text from PDF file in preview without adobe PDF reader component installed. Able to pull text out of selected PDF page or all PDF document in .NET
www.rasteredge.com
control application system:C# PDF delete text Library: delete, remove text from PDF file in
Able to pull text out of selected PDF page or all PDF option, The search and delete match rules. -. pageCount, The count of pages that will be deleted a string.
www.rasteredge.com
Apollo 8p Hardware Manual
Front Panel 
13
Preamp State Indicator
In addition to the channel’s relative preamp gain, the ring also indicates the current state 
of the preamp channel:
Green (variable) – The preamp is in default operating mode with variable gain
Green (fixed at maximum) – LINE is selected for the channel (#4) and LINE INPUT GAIN 
is set to BYPASS in the Hardware panel within the Console Settings window
Unlit – The preamp gain is set to its minimum value
Orange – A Unison plug-in is active in Console’s dedicated Unison insert for the channel.
Note: See the Unison chapter within the Apollo Software Manual for complete 
details about Unison operation.
(4–9) Preamp Options
This set of six switches control the preamp options for input channels 1 – 8. Press the 
switches to toggle the setting. The current state of each preamp option is indicated by 
the LED within each button. Each switch function is detailed below.
(4) Mic/Line
This switch switches between the channel’s Mic (XLR) and Line (¼”) inputs on the rear 
panel combo jacks. This switch has no effect if the channel’s Hi–Z input is connected 
(the Hi-Z input must be disconnected to use the Mic/Line inputs).
Note: Line inputs 1 – 8 can be set to bypass the preamp circuitry. See Line Input 
Gain Bypass for additional details. 
(5) Low Cut Filter
When enabled, the channel’s input signal passes through a low cut (high pass) filter. This 
2nd-order coincident-pole filter has a cutoff frequency of 75 Hz with a slope of 12 dB 
per octave.
The Low Cut filter affects the Mic, Line, and Hi-Z inputs. Low Cut is typically used to 
eliminate rumble and other unwanted low frequencies from the input signal. 
(6) Phantom Power (+48V)
When enabled, 48 volts of phantom power is supplied at the channel’s rear panel XLR 
input. Most modern condenser microphones require 48V phantom power to operate. This 
option can only be activated when the Mic/Line switch (#4) is set to Mic.
Caution: To avoid potential equipment damage, disable +48V phantom power on 
the channel before connecting or disconnecting its XLR input.
Depending on the current configuration of the hardware and software, there may be a 
delay when changing the 48V state to minimize the clicks/pops that are inherent when 
engaging phantom power. The +48V LED will blink rapidly during any delay.
control application system:C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
VB.NET comment annotate PDF, VB.NET delete PDF pages, VB.NET can view PDF document in single page or continue pages. Support to zoom in and zoom out PDF page.
www.rasteredge.com
control application system:VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
Auto Fill-in Field Data. Field: Insert, Delete, Update Field. can view PDF document in single page or continue pages. Support to zoom in and zoom out PDF page.
www.rasteredge.com
Apollo 8p Hardware Manual
Front Panel 
14
(7) Pad
When enabled, the channel’s XLR input signal level is attenuated by 20 dB. Pad does 
not effect the Line or Hi-Z inputs.
Pad can be used to reduce signal levels when overload distortion is present at low 
preamp gain levels, such as when particularly sensitive microphones are used on loud 
instruments, and/or if the A/D converter is clipping.
(8) Polarity (ø)
When enabled, the polarity (aka “phase”) of the input channel’s signal is inverted. 
Polarity affects the Mic, Line, and Hi-Z inputs.
Tip: Polarity inversion can help reduce phase cancellations when more than one 
microphone is used to record a single source.
(9) Stereo Link
This switch links the preamp controls of adjacent channels (1+2, 3+4, 5+6, 7+8) 
together to create stereo input pairs. When channels are linked as a stereo pair, any 
preamp control adjustments will affect both channels of the stereo signal identically.
Note: Only the same type of inputs can be linked (Mic/Mic or Line/Line). The Hi-Z 
inputs cannot be linked.
(10) Input Indicators
These indicators (MIC/LINE/HI-Z) display which input is currently active for the channel. 
To select MIC or LINE, use the INPUT switch (#4). To select Hi-Z, plug a ¼” mono TS 
cable into the Hi-Z input.
LINE indicator color
The color of the LINE indicator changes to reflect the state of the LINE INPUT GAIN 
setting, which is configured in the Hardware panel within the Console Settings window.
White – The line input is routed through the preamp so the input gain can be adjusted. 
Green – The preamp circuitry is bypassed and the line input is fixed at a reference level 
of +4 dBu. 
(11) Channel 1 – 8 Select Indicators
The currently selected preamp channel is indicated by the illuminated numbers above 
level meters 1 – 8. When a preamp channel (or channels, when stereo linked) is 
selected, its channel number is illuminated. The currently selected channel increments 
when the Preamp knob (#2) is pressed.
control application system:C# WPF PDF Viewer SDK to view PDF document in C#.NET
Auto Fill-in Field Data. Field: Insert, Delete, Update Field. extract, copy, paste, C#.NET rotate PDF pages, C#.NET Abilities to zoom in and zoom out PDF page.
www.rasteredge.com
control application system:VB.NET PDF replace text library: replace text in PDF content in vb
Able to pull text out of selected PDF page or all PDF document in VB.NET. VB.NET: Replace Text in PDF File. VB.NET: Replace Text in Consecutive PDF Pages.
www.rasteredge.com
Apollo 8p Hardware Manual
Front Panel 
15
(12) Channel Level Meters
The 10-segment LED channel meters display the input or output signal peak levels for 
analog channels 1 – 8. Input or output metering is selected with the METER switch 
(#19), and the input/output state is shown by the METER indicators (#15).
The dB values of the meter LEDs are indicated between the meters for channels 4 and 5. 
When digital clipping occurs in input (when 0 dBFS is exceeded), the red “C” (clip) LED 
illuminates. 
Input Channel Meters
When set to INPUT, the channel meters display the signal peak input levels for analog 
channels 1 – 8 at the input to the A/D converters.
Avoid digital clipping at the channel’s A/D converter by reducing the preamp gain and/
or engaging the Pad (#7) and readjusting gain as needed, or reducing the output level of 
the device connected to the channel’s input. 
Output Channel Meters
When set to OUTPUT, the channel meters display the signal peak output levels for analog 
channels 1 – 8 at the output of the D/A converters. 
Apollo 8p front panel (right portion)
(13) HOST Indicator
The HOST indicator displays the status of the Thunderbolt connection to the host 
computer system. The possible states are:
Lit – The unit is communicating with the host computer and operating normally.
Unlit – The unit is starting up or it is not recognized by the host computer. Verify 
software installation and Thunderbolt connections.
Red – System error. Please contact technical support if the issue persists. 
MONITOR
2
1
POWER
HEADPHONES
METER
ALT
FCN
OUT
OFF
1
2
C
0
-6
-3
-9
-12
-15
-18
-21
-27
88.2
RATE
44.1
48
176.4
96
192
HOST
CLOCK
INT
EXT
METER
IN
OUT
1
2
C
0
-6
-3
-9
-12
-15
-18
-21
-27
88.2
RATE
44.1
48
176.4
96
192
HOST
CLOCK
INT
EXT
METER
IN
OUT
13
17
16
18
19
20
22
23
24
26
25
21
14
15
control application system:VB.NET PDF - View PDF with WPF PDF Viewer for VB.NET
Auto Fill-in Field Data. Field: Insert, Delete, Update Field. extract, copy, paste, C#.NET rotate PDF pages, C#.NET Abilities to zoom in and zoom out PDF page.
www.rasteredge.com
control application system:VB.NET PDF File & Page Process Library SDK for vb.net, ASP.NET
document is unnecessary, you may want to delete this page get a PDF document which is out of order on creating, loading, merge and splitting PDF pages and Files
www.rasteredge.com
Apollo 8p Hardware Manual
Front Panel 
16
(14) CLOCK Indicators
Apollo 8p’s clock source and status are displayed with these indicators. Either internal 
(INT) or external (EXT) is displayed. The clock source is set within the Console 
application; see the Apollo Software Manual for details. 
Internal Clock
When Apollo 8p is set to internal clock, the INT indicator is illuminated white.
External Clock
Apollo 8p can use an external clock from the Word Clock, S/PDIF, or ADAT inputs. The 
EXT indicator has two possible states:
White – When set to external clock and a valid clock signal is detected at the specified 
port, the EXT indicator is illuminated white and Apollo 8p is synchronized to the external 
clock source. 
Red – When set to external clock and a valid clock signal is NOT detected at the 
specified port, the EXT indicator is illuminated red and the internal clock remains active 
instead. In this situation, if/when the specified external clock becomes available, Apollo 
8p switches back to the external clock, and the EXT indicator is illuminated and white.
Important: When set to use any external clock source, Apollo 8p’s sample rate 
must be manually set to match the sample rate of the external clock.
(15) METER Indicators
These indicators show the current state of the Channel Level Meters (#12). The current 
state is changed with the METER switch (#19). 
IN – When IN is illuminated, the channel meters display input signal levels.
OUT – When OUT is illuminated, the channel meters display output signals levels.
(16) Power Indicator (UA Logo)
The Universal Audio logo illuminates when the external power supply is properly 
connected to the AC outlet and the power input on the rear of the unit, and the Power 
switch (#26) is in the up position. 
(17) Sample Rate Indicators
These indicators display the current sample rate setting for A/D and D/A conversion. 
The sample rate is set within the Console application or the host DAW; see the Apollo 
Software Manual for details.
control application system:C# PDF Image Redact Library: redact selected PDF images in C#.net
Fill-in Field Data. Field: Insert, Delete, Update Field. extract, copy, paste, C#.NET rotate PDF pages, C#.NET NET control allows users to black out image in PDF
www.rasteredge.com
control application system:C# PDF Text Extract Library: extract text content from PDF file in
Ability to extract highlighted text out of PDF document. How to C#: Extract Text Content from PDF File. C# example code for text extraction from all PDF pages.
www.rasteredge.com
Apollo 8p Hardware Manual
Front Panel 
17
(18) Monitor Output Level Meters
The 10-segment LED meters display the signal peak output levels of the rear panel Left 
& Right Monitor outputs at the output of the D/A converters. These meters are before the 
Monitor Level control (pre-fader) and reflect the D/A converter levels regardless of the 
current Monitor Level and Headphone Level knob settings.
The dB values of the monitor meter LEDs are indicated between the left and right 
channel meters. When digital clipping occurs, the red “C” (clip) LED illuminates.
If the monitor output level clips, reduce the monitor output level within the DAW and/or 
reduce the output level of individual channels feeding the monitor output bus within the 
Console application. 
(19) Meter Switch
This switch determines whether the Channel Level Meters (#12) are displaying input 
levels or output signal levels. Pressing the switch toggles the state of the meters and the 
Meter Indicators (#15).
(20) Monitor ALT Switch
When ALT monitoring is configured in the Hardware panel within the Console Settings 
window (when ALT COUNT is set to a non-zero value), this switch toggles between the 
main monitor outputs and the ALT 1 outputs (line outputs 1 & 2). 
When the ALT switch is engaged:
•  The monitor signals are routed to outputs 1 & 2 instead of the main monitor outputs
•  The orange LED within the switch is illuminated
•  The Monitor Level Indicator (#23) is orange instead of green
For complete details about how to configure and use the ALT monitoring features, see the 
Apollo Software Manual.
Tip: ALT 2 outputs (line outputs 3 & 4) can be selected with the FCN switch 
(#21, when configured in Console Settings) or in the Monitor column within the 
Console application.
Apollo 8p Hardware Manual
Front Panel 
18
(21) Monitor Function Switch (FCN)
This is an assignable switch that can be configured to control one of three monitoring 
functions. The function of the switch is configured with the FCN SWITCH ASSIGN menu 
the Hardware panel within the Console Settings window; see the Apollo Software Manual 
for details.
The amber LED within the switch flashes when the monitoring function is active. The 
function is toggled with the switch is pressed again. The available functions are: 
ALT 2 – Selects the Alternate 2 monitor speakers. The monitor signals are routed to 
outputs 3 & 4 instead of the main monitor outputs, and the Monitor Level Indicator 
(#23) is amber instead of green when ALT 2 is active.
MONO – Sums the left and right channels of the stereo monitor mix into a monophonic 
signal. The Monitor Level Indicator (#23) flashes when MONO is active.
DIM – Attenuates the signal level at the monitor outputs by the dB amount set in the 
Control Room strip within the Console application. The Monitor Level Indicator (#23) 
flashes when DIM is active. 
Note: When more than one Apollo interface is connected in a multi-unit configura-
tion, the FCN switch is operable on the designated monitor unit only.
(22) Monitor Level & Mute Knob
This rotary encoder serves two functions. Rotating the knob adjusts the monitor output 
level, and pressing the knob mutes the monitor outputs. 
Monitor Level
Rotating the knob clockwise increases the signal level at the Left & Right Monitor 
Outputs on the rear panel. If ALT monitor outputs are configured and active, this knob 
controls the signal level at the ALT monitor’s line outputs. 
Although this is a digital control, the Left & Right Monitor Outputs volume is attenuated 
in the analog domain, after D/A conversion (digitally-controlled analog volume). This 
method provides the utmost monitoring fidelity, in contrast to digital volume controls that 
reduce levels by truncating the digital word length (aka “dropping bits”).
Apollo 8p Hardware Manual
Front Panel 
19
Monitor Output Gain Bypass
By default, monitor output levels are continuously variable. However, the monitor 
outputs can be set to completely bypass the monitor level circuitry and operate at a 
fixed reference level. This feature is set with the MONITOR OUTPUT GAIN menu in the 
Hardware panel within the Console Settings window. 
Tip: This feature routes the signal directly from the D/A converters to the monitor 
outputs for the purest path when level control is not needed (for example, when 
connecting the monitor outputs to an external monitor controller).
When the MONITOR OUTPUT GAIN menu is set to BYPASS in Console Settings:
•  The Monitor Level Indicator ring (#23) is solid green
•  When the Monitor knob (#22) is rotated, the ring flashes to indicate that no level 
adjustment is occurring
•  ALT monitoring and assignable FCN switch features are unavailable
•  Signals at the Monitor Outputs (#33) are output at line level (without attenuation)
Monitor Mute
Pressing the Monitor knob toggles the mute state of the signals at the Left & Right 
Monitor Outputs on the rear panel. If ALT monitoring is configured in the Hardware panel 
within the Console Settings window (when ALT COUNT is a non-zero value), the ALT 
monitor outputs are also muted by this control.
When the monitor outs are muted, the Monitor Level Indicator ring (#23) is red.
Note: Monitor Mute does not mute the headphone outputs.
Apollo 8p Hardware Manual
Front Panel 
20
(23) Monitor Level & Monitor State Indicator
Tip: The Monitor Level and Monitor State indications are reflected in the Monitor 
column within the Console application.
Monitor Output Level Indicator
The relative signal level at the rear panel monitor outputs (and ALT monitor outputs, if 
configured) is indicated by the illuminated ring surrounding the Monitor Level knob.
This indicator is after the Monitor Level control (post fader). It indicates relative levels 
only and is not calibrated to specific dB values.
Monitor State Indicator
The color of the indicator ring indicates the current state of the monitor outputs:
Green (variable) – The main monitor outputs are active with variable level control
Green (fixed at maximum) – MONITOR OUTPUT GAIN is set to BYPASS in the Hardware 
panel within the Console Settings window
Red – The main monitor outputs (and ALT monitor outputs, if configured) are muted
Orange – The ALT 1 monitor outputs are active
Amber – The FCN switch is active and assigned ALT 2
Flashing – The monitor DIM and/or MONO functions are active
(24) Headphone Level Knobs 1 & 2
These knobs control the volume of Headphone Outputs 1 & 2 on the front panel. Each 
headphone output has its own volume control.
(25) Headphone Outputs 1 & 2
These ¼” stereo TRS phone jacks are for connecting stereo headphones to Apollo 8. 
Headphone outputs 1 & 2 are individually addressable. 
By default, both headphone outputs mirror the monitor outputs. When mirroring the 
monitor outputs, the headphone outputs are unaffected by Monitor Mute (#18), to 
facilitate recording/tracking with headphones while the monitor speakers are muted.
Unique mixes can be created for each headphone output using the CUE functions within 
Console or by assigning mix buses from a DAW to the headphone outputs via the device 
drivers. 
(26) Power Switch
This switch applies power to Apollo 8. When the unit is powered on, the Universal Audio 
logo (#16) is illuminated. The external power supply must be properly connected for this 
switch to function.
Documents you may be interested