Alarm
Click this button to display the alarm output port status. If "Alarm Hold" has been 
selected, the alarm can be cleared by clicking the "Alarm Clear" button.
10
Statistics/Log 
Display
Click this button to display the results of statistical calculation performed during 
data capture, and a log of the alarms generated.
11
Start Time
Data capture start time.
12
Capture Time
The amount of time that has elapsed since the start of data capture.
13
Allowable Time
The amount of time available for data capture. When the remaining time is up, 
data capture stops at both the device and the PC.
14
Number
The number of data capture operations when Repeat Capture has been specified.
15
Sampling Interval The sampling interval. 
* EXT is displayed during external sampling.
16
PC Capture 
Destination
The data capture destination at the PC.
17
Screen switching
Switches between screens (Y-T/Y-T Zoom/Digital/Report Views).
18
Waveform Graph
The waveforms are displayed here.
19
Cursors
Selects which of the cursor values should be displayed in the digital display area 
when scroll is stopped during capture. Up to three values (Cursor A, Cursor B, 
Cursor A-B) can be displayed at the same time.
This function is available when the scroll is Off during capture, or during replay.
20
Switch displayed 
groups
Click one of these buttons to select a group whose waveform and digital values 
are displayed.
21
Digital
The digital values are displayed in this area. Clicking on any of the CH numbers 
enables the waveform for that channel to be hidden/displayed. The channels for 
which an alarm has been generated are shown in red.
The waveform display On/Off setting is cleared when the capture settings are changed and is reset to On.
22
Cursor Time
The cursor times are displayed during data capture when Scroll Off has been 
selected.
23
Waveform Op.
Click this button to perform various settings for the waveform display. Refer to 
section 13-3 for details.
Rotate pages in pdf permanently - rotate PDF page permanently in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Empower Users to Change the Rotation Angle of PDF File Page Using C#
pdf page order reverse; how to rotate just one page in pdf
Rotate pages in pdf permanently - VB.NET PDF Page Rotate Library: rotate PDF page permanently in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
PDF Document Page Rotation in Visual Basic .NET Class Application
how to rotate pdf pages and save; how to rotate page in pdf and save
22
Y-T Zoom
9-2. 
Switches to full-screen Y-T View. The operation is the same as in Y-T View.
VB.NET PDF Page Redact Library: redact whole PDF pages in vb.net
file & pages edit, C#.NET PDF pages extract, copy, paste, C#.NET rotate PDF pages, C#.NET Enable VB.NET Users to Redact PDF Pages to Protect PDF Document in
how to rotate a single page in a pdf document; rotate single page in pdf reader
C# PDF Page Redact Library: redact whole PDF pages in C#.net, ASP.
Page: Rotate a PDF Page. PDF Read. Text: Extract Redaction is the process of permanently removing visible our redact function API to redact entire PDF pages.
rotate one page in pdf; rotate single page in pdf file
23
Digital
9-3. 
The captured data is displayed as digital values. Instantaneous values are displayed in large characters to enable 
easy confirmation.
1
2
3
4
No.
Name
Description
1
Analog
20 analog channels' digital values are displayed here.
2
Set displayed CH
Click one of these buttons to select 20 analog channels to display the digital 
values.
It is not displayed for GL220 or GL200A.
3
Pulse
Pulse signals' digital values are displayed here. (when the Logic/Pulse setting is 
"Pulse")
4
Logic
Logic signals' digital values are displayed here. (when the Logic/Pulse setting is 
"Logic")
VB.NET Image: How to Process & Edit Image Using VB.NET Image
VB.NET Image Rotator Add-on to Rotate Image, VB.NET Watermark Maker to VB.NET image editor control SDK, will the original image file be changed permanently?
pdf reverse page order preview; pdf rotate pages and save
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit Excel
to change view orientation by clicking rotate button. users can convert Excel to PDF document, export Users can save Excel annotations permanently by clicking
rotate pdf pages individually; how to reverse page order in pdf
24
Report
9-4. 
Displays daily report data during capture when the daily report function is enabled. The displayed data can be 
displayed on EXCEL in the Free Running status.
If Off has been specified for the Report setting, report data is not displayed.
1
2
3
4
No.
Name
Description
1
Display in Excel
The data is displayed in Excel format when the device is in the Free Running 
status.The Microsoft Excel program must be installed in order for the Export to 
Direct Excel File function to be used.
* Data displayed on EXCEL is only data displayed in the report.
2
Daily Report 
Capture Interval
The daily report capture interval is displayed here.
3
Daily report data
The daily report data is displayed here. If the number of points exceeds 100, data 
is deleted starting from the oldest data (the actual data is not affected).
4
Calc. resultsThe
The calculated results for the average, maximum and minimum values are 
displayed here.
VB.NET Image: How to Create a Customized VB.NET Web Viewer by
used document & image files (PDF, Word, TIFF btnRotate270: rotate image or document page in burnAnnotationToImages: permanently burn drawn annotation on page in
pdf rotate all pages; rotate all pages in pdf file
How to C#: Cleanup Images
By setting the BinarizeThreshold property whose value range is 0 to 255, it will permanently modify the image to 1bpp grayscale image of the Detect Blank Pages.
reverse page order pdf online; rotate pages in pdf permanently
25
Settings Screens
10. 
This chapter describes the screens used to perform settings related to data capture.
AMP Settings
10-1. 
This screen is used to make the analog input, logic input, and pulse input settings.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
No.
Name
Description
1
Settings tabs
These tabs are used to change the settings screen.
AMP Settings
This tab is used to make input-related settings.
Data Capture Settings This tab used to make settings related to data capture.
Trigger/Alarm Settings This tab is used to make settings related to the trigger 
and alarm functions.
Report Settings
This tab is used to make settings related to the daily 
report, monthly report, and Export to Direct Excel File 
functions
Other Settings
This tab is used to make various other settings, to 
display information, and so forth.
2
CH
These are the channel numbers for analog input.
3
Color
The color used for the waveform for each channel can be specified here.
* The line color settings are not stored in captured data. Since the setting values of this software are used, 
the line colors may be different during capture and replay.
4
Annotation
Each channel can be freely annotated (input the signal name, etc.). The maximum 
number of characters is 31 (in single-byte).
How to C#: Color and Lightness Effects
Geometry: Rotate. Image Bit Depth. Color and Contrast. Cleanup Images. NET comment annotate PDF, VB.NET delete PDF pages, VB.NET VB.NET How-to, VB.NET PDF, VB.NET
save pdf after rotating pages; rotate individual pages in pdf reader
26
No.
Name
Description
5
Input
Select the input type for each channel.
Off
No input is made to that channel.
DC
Select DC to perform voltage measurement.
TEMP
Select TEMP to perform temperature measurement.
RH
Select RH to perform humidity measurement.
6
Range
These buttons are used to select the input range for each channel.
DC
20/50/100/200/500(mV)/1/2/5/10/20/50(V)/1-5V
TEMP
TC-K/TC-J/TC-T/TC-R/TC-E/TC-B/TC-S/TC-N/TC-W
Pt100
*
/JPt100
*
/PT1000
*  (* is only GL820 or GL800)
RH
Fixed to 1 V; the unit is converted internally.
0V → 0%, 1V → 100%
7
Filter
Use these buttons to set the filter for each channel. Moving average processing 
is used in the filter. It captures the data for configured number of times at the 
configured sampling rate and performs average processing.
(Off/2/5/10/20/40)
8
Unit
The selected unit is displayed here.
9
Auto Zero
Adjusts the current input value as the zero points for each channel (voltage and 
humidity only). Refer to section 10-1-1 for details.
10
Span
Use these buttons to set the upper limit and lower limit values for the waveforms 
displayed in the waveform graph. Refer to section 10-1-2 for details
11
Scaling
Use these buttons to convert the unit. Refer to section 10-1-3 for details
12
CH Group
Use these buttons to set the display group for each channel. Only the groups set 
here can be viewed in Y-T display screen.
13
Graph Display
The waveforms for which settings have been made can be checked here. Click 
the "Apply" button to apply the settings that have been made.
14
Logic/Pulse 
switching
Use this button to switch the digital input. Logic, Pulse, or OFF can be set here. 
This setting is not available for GL200A.
(Off/Pulse/Logic)
15
Logic CH number
The channel numbers for logic input.
16
Logic Line Color
Make the logic waveform color setting here.
17
Logic Filter
Make the logic filter setting here. The filter is about -3dB at about 30Hz. 
(Off/On)
18
Pulse CH number The channel numbers for pulse input.
19
Pulse Line Color
Make the pulse line color setting here.
20
Pulse Input
Use the Input button to select the pulse input type. * 
The upper limit of the count in one 
sample is 50k.
Revolutions
The number of pulses generated in one second is counted, 
multiplied by 60, and displayed as the number of revolutions 
(RPM).
Counts
A cumulative count is made of the number of pulses 
generated in one sample.
Inst.
The number of pulses generated in one sample is counted.
21
Pulse Range
Use these buttons to set the pulse range. 
Revolutions
50/500/5000/50k/500k/5M/50M/500M (RPM/F.S.)
Counts
50/500/5000/50k/500k/5M/50M/500M (C/F.S.)
Inst.
50/500/5000/50k/500k/5M/50M/500M (C/F.S.)
22
Pulse Filter
Make the pulse filter setting here. The filter is about -3dB at about 30Hz. 
(Off/On)
27
No.
Name
Description
23
Pulse Slope
Use this button to select the pulse detection slope.
H
Rising signals are counted.
L
Falling signals are counted.
24
Pulse Span
Use this button to set the upper limit and lower limit values for the waveforms 
displayed in the waveform graph.
25
Pulse Scaling
Use this button to convert the unit.
26
OK
Click this button to register your settings and close the screen.
27
Cancel
Click this button to close the screen without registering your settings.
28
Apply
Click this button to apply the settings mode.
Auto Zero Setting
10-1-1. 
Performs zero adjustment.
The adjustable range is ±10% of the setting range.
(Example: For a range of 1V, the full scale is ±1 V, and the adjustable range is ±100 mV.)
2
1
3
4
No.
Name
Description
1
CH
Displays a channel for which Auto Zero ADJ. should be performed.
2
Perform Auto Zero 
ADJ.
Performs Auto Zero ADJ.
* If you have changed the input or range just before this step, first click 
"Apply" in the capture setting screen.
3
Reset Auto Zero 
ADJ.
Resets the zero adjustment to the initial state. 
* Changing the range will reset this setting.
4
Zero position 
voltage value
Displays the adjusted value after Zero ADJ.
Span Settings
10-1-2. 
Span settings are made at this screen.
To make the settings, input numerical values directly or use a cursor to adjust values.
Upper Value Input
Lower Value Input
Upper Cursor
Waveform
Lower Cursor
Settings CH
28
Scaling Settings
10-1-3. 
Sets the scaling (unit conversion). Enter the upper and lower limits of the input and converted values. For the 
temperature channel, the offset setting with two points is used. 
* If you have changed the input from the temperature or voltage just 
before retrieving the temperature measurement values, first click "Apply" in the capture setting screen.
Input
Upper Value Input
Scaling
Upper Value Input
Input
Lower Value Input
Scaling
Lower Value Input
Reference value
Value for the adjustment
Setting CH
Setting CH
Take temperature measurements
Scaling Unit
<Voltage>
<Temperature>
Data Capture Settings
10-2. 
Settings such as the Sampling Interval, Device Capture Settings and PC Capture Settings are made at this screen.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
No.
Name
Description
1
Sampling Interval Specifies the sampling interval for data capture.
The sampling interval that can be specified depends on the number of measured 
channels.
10/20/50/100/125/200/250/500(ms)/1/2/5/10/20/30(s)/1/2/5/10/20/30(min)/1(h)
* Allowable settings vary with the input setting and the number of measurement channels.
29
No.
Name
Description
2
External sampling
Sets the external sampling function to On or Off.
If set to On, data is captured using signals entered from the external input 
terminal.
Signals that can be entered from the external input terminal must be slower than 
the "fastest interval" display.
Refer to the User's Manual for details.
* This function is available only for the GL220 and GL820.
3
AC Line Filter
Sets the AC line filter function to On or Off in the external sampling settings.
The On or Off setting will change the fastest interval of the external sampling.
Refer to the User's Manual for details.
* This function is available only for the GL220 and GL820.
4
Fastest interval
Displays the fastest interval of external sampling when the external sampling 
function is used. The fastest interval varies with the AC line filter setting and the 
number of measurement channels. Refer to the User's Manual for details.
* This function is available only for the GL220 and GL820.
5
Device Capture 
Destination 
Settings button
Use this button to specify the On/Off of data capture of the GL device.
On
Data capture operation is also performed on the GL device.
Data capture cannot be started when there is no space in 
the data capture destination of the device.Data is captured to 
both the device and the PC.
Off
Data capture operation is not performed on the GL device.
Data capture can be started when there is no space in the 
data capture destination of the device.Data is captured only 
to the PC.
* A setting of capturing data in CSV format to this unit is not available.
6
Device Capture 
Settings
Allowable capture 
time
The length of time available for data capture to the selected device storage 
medium (internal memory or USB device) is displayed here.
7
Device Capture 
Settings
Name Type
Use this button to select the method for appending the file name.
Auto
Create a date folder in the specified folder, and then create a 
date and time file in it.. (Example: 2010-04-01_12-34-56.GBD)
User
The file name can be freely specified by the user.
8
Device Capture 
Settings
Save Path
The save destination at the device for the captured data is selected here.
9
Ring Capture
Ring Capture is a function that captures data while deleting old data when a 
specified number of capture points is exceeded. This function sets the Ring 
Capture function to On or Off on the GL220 or GL820 unit.
Refer to the User's Manual for details.
* Ring Capture is supported only on this unit. Only normal capture is available on the PC.
* This function is not available for the GL200A and GL800.
10
Ring Capt. Pts.
Sets the number of capture points when Ring Capture is performed.
Refer to the User's Manual for details.
11
Ring Allowable 
Capture Time
Displays the time available for capture in Ring Capture.
Refer to the User's Manual for details.
12
PC Capture 
Settings
Format
Use this button to select the format of the data saved to the PC (personal 
computer).
Binary format (GBD)
The data is saved as binary data. When compared 
with a CSV file, the file size is somewhat small.
Text format (CSV)
The data is saved as text data in a format that can be 
displayed in Excel. 
30
No.
Name
Description
13
PC Capture 
Settings
Name Type
Use this button to select the method for appending the file name.
Auto
A folder with the date as the file name is created within the 
specified folder, and then a file with the date and time as the 
file name is created within the newly-created folder. (Example: 
Device1_2010-04-01_12-34-56.GBD)
User
The file name can be freely specified by the user.
14
PC Capture 
Settings
Save Path
The save destination at the PC (personal computer) for the captured data is 
selected here.
15
PC Capture 
Settings
Create Backup File
To enable this function, click the checkbox to display the check mark. The backup 
file is created at the same location as that specified in Item 14 "Save Path" above. 
The "_bk" file extension is appended to the file name.
16
PC Capture 
Settings
Backup Interval
Use this button to select the backup interval. During data capture, a backup data 
file is created at the specified intervals. If all the backup files are linked, the data 
will be same as that of the original data. (1/2/6/12/24(h))
* A fluctuation of about 10 seconds will be generated in the backup interval.
Therefore, the data size of a backup file fluctuates to some degree.
Since there is no loss of data, however, you can concatenate backup files to obtain data equivalent to that 
of one backup file that you would obtain from continuous capture.