THE DATA LEVEL - BASIC FUNCTIONS
201
Q
UICK
C
ODING
(C
TRL
+S
HIFT
+Q)
Codes with the last used code
C
ODES
T
EXT
S
EARCH
R
ESULTS
Codes the results of a text search
How Codes are Displayed
After a code has been created, it appears as a new entry in several locations 
(e.g. in the margin area, the drop-down list, the code manager). 
The selected code word is written next to the quotation bar in the margin. You 
can recognize codes by the yellow diamond symbol. 
The entry in the drop-down list in 
Figure 104: Quotation reference
reads: “test 
1 {1-0}”. The first number shows the frequency (how often the code has been 
applied). It gives you some information on the groundedness of a code, i.e. 
how relevant this code is in the data. The second number the density (how 
many other codes this code is linked to). Hence the code “Test 1” has been 
used only once so far and it is not yet linked to any other code. 
Display of codes in the Code Manager
The Code Manager provides a number of typical Windows display options like 
Large Icons, Small Icons, List and Details. The details view has already been 
described at “Code Manager Columns” on page 60.
ATLAS.ti 6 USER MANUAL
Figure 116: Codes in ATLAS.ti
Pdf reverse page order - rotate PDF page permanently in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Empower Users to Change the Rotation Angle of PDF File Page Using C#
pdf rotate just one page; how to rotate pdf pages and save
Pdf reverse page order - VB.NET PDF Page Rotate Library: rotate PDF page permanently in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
PDF Document Page Rotation in Visual Basic .NET Class Application
pdf page order reverse; pdf rotate pages separately
THE DATA LEVEL - BASIC FUNCTIONS
202
The Single Column View
Within curly brackets following the code name, groundedness and density are 
displayed.
Grounded(ness). As explained above, groundedness refers to the number of 
quotations associated with a code. In the above example, groundedness is 8. 
This means, the code *name of suspect: Kosminski has been used for coding 
eight times.
Density. In the above example the density is 2, thus two codes have been 
linked to the code *name of suspect: Kosminski. Links between codes are 
established by the user either by dragging and dropping codes onto each other 
in the Code Manager or by linking them in in a Network View (see page 329).
Comment. The tilde character "~" flags commented codes. It is used not only 
for codes but for all commented objects.
Open Coding
Open Coding assigns new codes with already existing or newly created 
quotations. You can create one ore more codes in a single step.
Coding with a single new code
Select the data section or the quotation you want to code.
Click the Open Coding button (see above) or choose 
C
ODING
 / O
PEN
 C
ODING
from the main or context menu. 
ATLAS.ti 6 USER MANUAL
Figure 118: Code display
Figure 117: View context 
menu
C# PDF Page Move Library: re-order PDF pages in C#.net, ASP.NET
page. Enable C# users to move, sort and reorder all PDF page in preview. Support to reverse page order in PDF document. RasterEdge
pdf reverse page order preview; pdf rotate all pages
VB.NET PDF Page Move Library: re-order PDF pages in vb.net, ASP.
Support to reverse page order in adobe PDF document in both .NET WinForms application and ASP.NET webpage. Enable move, sort and reorder PDF page in preview.
rotate all pages in pdf; how to rotate all pages in pdf at once
THE DATA LEVEL - BASIC FUNCTIONS
203
A dialog will open. Enter the code name and click OK.
The new code now appears in the Code Manager. The coded segment 
(quotation) is displayed in the Quotation Manager.
Make it a habit to write a comment for every new code (see Writing Code
Comments on page 206.
Creating more than one code concurrently
When using the Open Coding procedure, more than one code can be created 
at a time. In order to do so, you need to separate the code names with the 
“vertical bar” or “pipe” character "|" (ASCII 124). 
The entry victim|modus operandi|media coverage creates three new codes. 
Already existing codes are not created anew. 
Coding via drag & drop from the Code Manager
The easiest way of coding is via Drag & Drop from the Code Manager. 
Select a data section.
Open the Code Manager.
Select one or more codes in the Code Manager. 
ATLAS.ti 6 USER MANUAL
Create more 
than one code 
at a time using 
the “vertical 
bar” character.
Figure 120: Creating  multiple codes at once
The Code 
Manager offers 
bi-directional 
drag & drop.
Figure 119: Creating a new code using the context menu
Write 
comments!
C# Word: How to Use C# Code to Print Word Document for .NET
document pages in original or reverse order within entire C# Class Code to Print Certain Page(s) of powerful & profession imaging controls, PDF document, image
rotate single page in pdf reader; reverse page order pdf online
THE DATA LEVEL - BASIC FUNCTIONS
204
• Drag and drop the codes into the primary document pane. If a quotation 
already exists, you can alternatively drop the code onto a quotation bar in 
the margin area.
It is not necessary to drop the codes into the selected area. You may drop 
the codes anywhere inside the primary document pane.
In-Vivo Coding
Use in-vivo coding when the text itself contains a useful and meaningful name 
for a code. 
In-vivo coding creates a quotation from the selected text AND uses the 
selected text (trimmed to 30 characters) as the code name. If the selected text’s 
boundaries are not exactly what you want for the quotation, modifying the 
quotation’s “spread” (see “Modifying Textual and PDF Quotations” on page 
186) is often the next step after creating the in-vivo code. 
In-Vivo coding can only be applied to textual primary documents.
To create an In-Vivo code
Mark the text passage that you want to use as an in-vivo code. Bear in mind 
that the code name is created from the text selection’s first 30 characters .
Click the In-Vivo coding button or choose 
C
ODING
 / I
N
-V
IVO
 C
ODING
from the 
menu.
If needed, change the newly created quotation’s boundaries (“Modifying
Textual and PDF Quotations” on page 186 for details).
In-Vivo coding via drag & drop
Mark the text passage that you want to use for In-Vivo coding.
Open the Code Manager.
ATLAS.ti 6 USER MANUAL
The term "in-
vivo" in this 
context stems 
from grounded 
theory, which 
draws the 
researcher's 
attention to 
expressions 
used by the 
interviewees 
themselves.
Figure 121: Coding via drag & drop
THE DATA LEVEL - BASIC FUNCTIONS
205
Drag and drop the selected text into the Code Manager’s list pane or the 
code drop-down list.
You can create a code from each word of the selected text by holding down 
the ALT key when dropping the text.
Code-by-List
Select the data section/quotation to be coded.
Click the Code-by-List button or choose 
C
ODING
 / C
ODE
BY
 L
IST
from the menu. 
From the list window with applicable codes select one or more codes (while 
holding the Ctrl key) and click OK. 
The number of codes that you can select from the list is unlimited. If the data 
section resembles an existing quotation, only codes not already assigned to this 
quotation are offered.
Code-by-List Inverse
The standard code-by-list technique associates a list of codes to one selected 
quotation. Sometimes, it makes more sense to associate a list of quotations to 
one code. 
To link a code to many quotations 
In the Code Manager, or the drop down list select the code to be associated 
with one or more quotations.
From the main or the code’s context menu, choose C
ODES
/ C
ODING
/ L
INK
C
ODE
TO
:/ Q
UOTATIONS
.
A list of quotations that  were not already assigned to the selected code 
opens. Select one ore more quotations and click OK.
To link a code to many quotations via Drag & Drop
In the Quotation Manager select the quotations to be assigned to the code.
Drag & drop the selected quotations into the Code Manager onto the code.
Quick Coding
Quick Coding assigns the last used code to the current data segment. This is an 
efficient method for the consecutive coding of segments using the most 
recently used code.
Select a code in the Code Manager. 
Select a data segment.
Click the Quick Coding button  or choose C
ODING
/Q
UICK
C
ODING
from the 
menu.
ATLAS.ti 6 USER MANUAL
Code multiple 
quotations in 
one go. 
Create multiple 
In-Vivo codes
This procedure 
offers a list of 
all current codes 
from which one 
or more code 
can be selected 
and associated 
with the current 
data selection.
THE DATA LEVEL - BASIC FUNCTIONS
206
Meaning of colored bars in the margin
As you saw in 
Figure 105: Activating quotations via its code
overlapping 
codes are displayed in different colors in the margin area. These colors help you 
to distinguish which bar belongs to which code word. If you were to add even 
more layers, the next two layers would be displayed in violet and blue. After 
that, silver is used again. The colors do not contain any information about the 
different code levels in the sense of higher or lower ranked categories. When 
you delete a quotation, the colors may change. 
It is possible to set your own colors for codes, but not for the bars marking the 
length of a quotation (see “Setting code colors“ below).
Unlinking a code
Just as you can erase a pencil mark in the margin of a paper document, you can 
“erase” a code in the margin area on screen as well. The digital equivalent is 
called unlinking. It is mostly used when a segment is coded with more than one 
code.
To unlink a code, right click on the code in the margin area and click on the 
U
NLINK
option.
When you unlink a code from a segment that only has one code, the bar 
remains in the margin. If you want to “erase” both the code and the quotation, 
you need to proceed as explained below. 
Writing Code Comments
Like Primary Documents, comments can be added to clarify the meaning of a 
code or to explain how the code is to be used for coding. The practice of 
commenting objects greatly supports a transparent, and, if working as part of a 
team, cooperative working style.
Creating and Editing a Code Comment
Open the code manager and select a code.
Right click and select the option: E
DIT
C
OMMENT
from the context menu.
A text editor opens. Write or edit an existing comment.
Save the changes and close the editor.
ATLAS.ti 6 USER MANUAL
Use code 
comments to 
define your 
code words.
Figure 122: Meanings of colored bars in the margin
THE DATA LEVEL - BASIC FUNCTIONS
207
You can also use the text pane in the lower part of the Code Manager (see 
“Editing Text” on page 53) to create or edit a comment.
Writing comments for coded segments
If you notice something interesting while coding and you want to write it 
down, use the quotation comment field for it. 
Right click on the highlighted quotation and select the option E
DIT
C
OMMENT
from the context menu.
An editor pops up. Write a comment on the selected data segment.
Save your comment by clicking on the A
CCEPT
button and close the editor.
Quotation comments are visible in the bar in the margin area and by the tilde 
(~) sign in front of the quotation name in the quotations list.
Setting code colors
If you want to color your codes, select a code in the Code Manager and click 
on the rainbow colored circle in the tool bar.
To make code colors visible in the margin, right click on a white space in the 
margin area and select the option U
SE
O
BJECT
C
OLORS
In order to still be able see which code label belongs to which quotation bar, a 
small bar colored in the same color as the quotation bar is shown in front of the 
code label. The code label shows the user-defined color.
Coding PDF documents
PDF documents allow for various ways of coding. Basically, there are no 
restrictions, you can code any area within the document. If it is text, you code 
the characters of the text. If the PDF file contains an image, then ATLAS.ti 
ATLAS.ti 6 USER MANUAL
Figure 123: Drag & Drop coding
THE DATA LEVEL - BASIC FUNCTIONS
208
automatically switched to image mode and you code a rectangular area within 
the PDF file. Below you find a number of screen shots demonstrating the 
various options.
Coding as usual
Just highlight a section of text as you do in other text documents. 
The difference is that you can set a selection color (see PDF preferences) and 
that a PDF quotation has a “handle” on the top left and bottom right that you 
can use to easily modify the size of the quotation (see image below)
Coding embedded images
Select a rectangular area of your choice and use the handle at each corner to 
scale to the appropriate size.
Coding columns of text
As usual, just highlight a section of text within a column: 
ATLAS.ti 6 USER MANUAL
Figure 124: Coding a text segment in a PDF primary document
Figure 125: Coding an embedded image within a PDF document
THE DATA LEVEL - BASIC FUNCTIONS
209
Coding Image documents
Load an image document and select a rectangular area. Proceed to code it as 
has been described for text segments.
To change the display type, right click on the image quotation and select the 
option S
ELECTION
-D
ISPLAY
T
YPE
/I
NVERTED
A
REA
.
ATLAS.ti 6 USER MANUAL
Figure 127:  Inverted display for quotations
Figure 126: Coding text within a column of a PDF document
THE DATA LEVEL - BASIC FUNCTIONS
210
Coding audio and video documents
Coding audio and video files involves two steps. First a quotation needs to be 
created, and only then can you can link a code to it. 
Step 1: Create an audio or video quotation 
Load  an audio or video document.
In addition to the Code Manager, open the Quotation Manager. Re-size the 
two windows, so they fit next to each other. Move the time line to a 
convenient position and expand it so it covers the full length of the screen. 
Set a filter to the currently selected document so that the Quotation 
Manager only shows the quotes of the video you are working on.
From the main menu, select Q
UOTATIONS
/F
ILTER
/S
ELECTED
PD. The drop-down list 
and manager show a pale yellow color, indicating that a filter is set.
Currently the time line cannot be scrolled. Thus, the entire video needs to fit 
onto it. Therefore the recommendation is to cut your audio or video files to a 
length of about 20 minutes. Otherwise, the visual presentation of the 
quotations becomes very tiny and difficult to set. 
In version  7, ATLAS.ti will offer a margin area as already available for most 
other data file formats. Then the above described coding procedure can also be 
use for coding audio- and video files.
To create a quotation, move the cursor to a start position on the time line. 
Click the button Mark selection Start (see figures 109 and 129 below).
ATLAS.ti 6 USER MANUAL
Figure 128: Preparing the screen for coding a video file