display first page of pdf as image in c# : Permanently rotate pdf pages application SDK tool html wpf azure online atlasti_v6_manual38-part1207

SPECIAL TOOLS
381
Redundant Coding Analyzer
This procedure identifies overlapping or embedded quotations that are 
associated with the same code. Such “codings” -- possibly indicating 
redundancy -- can result from normal coding but may occur unnoticed during a 
merge procedure.
You might not need or want to correct redundant codings, but these 
occurrences may be indicative of methodological issues in your analysis.
The Redundant Coding Analyzer Screen
The Coding Analyzer finds codes with redundant codings and offers 
appropriate procedures. 
To open the tool, select T
OOLS
/ R
EDUNDANT
C
ODING
A
NALYZER
from the HU editor's 
main menu.
The upper pane displays a list of codes referencing overlapping quotations. 
Clicking on a code displays the conflicting quotations pair wise. Double-clicking 
on a listed quotation displays it in context.
ATLAS.ti 6 USER MANUAL
Figure 292: The Redundant Coding Analyzer
Permanently rotate pdf pages - rotate PDF page permanently in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Empower Users to Change the Rotation Angle of PDF File Page Using C#
how to rotate one pdf page; rotate pdf pages in reader
Permanently rotate pdf pages - VB.NET PDF Page Rotate Library: rotate PDF page permanently in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
PDF Document Page Rotation in Visual Basic .NET Class Application
how to save a pdf after rotating pages; rotate all pages in pdf preview
SPECIAL TOOLS
382
The upper pane lists all codes for which redundant codings were found. The 
Redundancy column displays the number of pairs of redundant quotations 
found for the codes. If you select one of the codes, the redundant quotations 
are listed in pairs in the two lower panes. Double-clicking on the listed 
quotations displays and highlights them in context. Because of this, you can 
check them in context and decide how to proceed. 
The figure below illustrates a typical redundant coding:
Three procedures to handle a redundant coding are offered:
Unlink detaches the selected code from the quotation selected in one of the 
quotation panes. This method is the least “destructive” of the available 
options.
Remove deletes the selected quotation.
Merge melts the quotation in the right pane into the quotation selected in the 
left pane. All references to and from the merged quotation is "inherited" by 
the other. If the two quotations overlap, the resulting quotation includes all 
data from both quotations.
Both quotation panes have a “Connectivity” column that shows the number of 
connections (to codes, quotations, and memos) for the selected quotation. The 
connectivity counter provides an additional clue about the next step. A 
quotation with less connections might be less painful to remove. 
If you see a quotation listed more than once in one of the quotation list panes, 
it means that three or more quotations are involved in a redundant coding. You 
will notice, that merging one pair of quotations may have the effect that other 
pairs are removed from the list as well, as the redundancy assertion does not 
hold any longer for the remaining pairs of quotations for this code.
Unlinking, Removing or Merging a Redundantly Coded Quotation
• Select a code in the upper pane. All pairs of redundantly coded quotations 
are then displayed in the two lower panes.
• Double-click on the quotations of a pair to inspect them in context. 
• Decide whether you want to unlink or remove one of the two quotations, or 
whether you want to merge them. 
ATLAS.ti 6 USER MANUAL
Figure 293: A typical redundant coding
VB.NET PDF Page Redact Library: redact whole PDF pages in vb.net
extract, copy, paste, C#.NET rotate PDF pages, C#.NET If you need to permanently removing visible text and our redact function API and redact entire PDF pages.
how to rotate a page in pdf and save it; how to reverse page order in pdf
C# PDF Page Redact Library: redact whole PDF pages in C#.net, ASP.
Page: Rotate a PDF Page. PDF Read. Text: Extract Redaction is the process of permanently removing visible our redact function API to redact entire PDF pages.
pdf save rotated pages; rotate pdf page and save
SPECIAL TOOLS
383
• To unlink a quotation click the U
NLINK
button below the appropriate list pane. 
The effect and alternative procedures of unlinking codes is described in 
further detail in  “Unlinking Codes” on page 218.
• To remove a quotation click the R
EMOVE
button below the appropriate list 
pane. 
• To merge the pair of quotations, click the M
ERGE
button. 
• Note that the quotations removed by this procedure cease to exist inside the 
Hermeneutic Unit.
ATLAS.ti 6 USER MANUAL
VB.NET Image: How to Process & Edit Image Using VB.NET Image
VB.NET Image Rotator Add-on to Rotate Image, VB.NET Watermark Maker to VB.NET image editor control SDK, will the original image file be changed permanently?
rotate all pages in pdf file; rotate pdf pages
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit Excel
to change view orientation by clicking rotate button. users can convert Excel to PDF document, export Users can save Excel annotations permanently by clicking
pdf rotate pages separately; rotate individual pages in pdf
SORTING AND FILTERING
384
Sorting and Filtering
The main strengths of a computer clearly lie in sorting and retrieving data. For 
such techniques to be deployed successfully, however, the data itself must have 
attributes by which it can be meaningfully ordered and filtered. A variety of 
attributes can be used for filtering and sorting data. Many entities within an HU 
can be filtered, for example, primary documents, codes, memos, and 
quotations. 
Sorting and filtering primary documents, codes, memos, and quotations can 
help you gain deeper insight into your data. 
Sorting and filtering can be accessed via the HU editor's menu or the Object 
Managers’ menus. The columns in the Object Managers’ report views may also be 
used for sorting. Some options for sorting and filtering are common to all objects, 
while others are dependent on the object’s type.
Sorting
Sorting is available via the Object Managers’ columns and the main menus of 
the HU Editor and the Managers.
Sorting in Object Managers
Sorting is conveniently available in all Object Managers via the list headers 
while in details view: clicking on a header “button” sorts the list in either 
ascending or descending order. 
ATLAS.ti 6 USER MANUAL
Click the header 
to sort the 
items. Click 
again to reverse 
the sort.
Figure 294: Sorting via the columns in object managers
VB.NET Image: How to Create a Customized VB.NET Web Viewer by
used document & image files (PDF, Word, TIFF btnRotate270: rotate image or document page in burnAnnotationToImages: permanently burn drawn annotation on page in
how to reverse pages in pdf; reverse page order pdf online
How to C#: Cleanup Images
By setting the BinarizeThreshold property whose value range is 0 to 255, it will permanently modify the image to 1bpp grayscale image of the Detect Blank Pages.
pdf reverse page order preview; how to rotate pdf pages and save
SORTING AND FILTERING
385
The column used for sorting is displayed in a darker shade. The sort direction is 
visualized by an arrow in the header. In four field of the status bar, the sort 
criterion is displayed.
A double-click on the status bar’s sort field refreshes the current sort. This is a 
useful option because newly added objects are appended to the end of the list 
regardless of their correct position in the sorted sequence.
Sorting via the menus
The Sort menu option is available in the object menus of the HU Editor 
(Documents, Quotations, Codes, and Memos) and from the corresponding 
Manager’s menu.
The figure below shows the Sort menu for documents with the current sort 
criterion set to ID (which is also the default):
In Object Managers, the currently selected sort criterion is also displayed in the 
status bar (see Error: Reference source not found). After new items are added 
to the list, refresh the sort with a double-click on the status pane’s sort field.
Overview of Sort Options 
The following describes the sort options in more detail. Default sort order: D = 
descending, A = ascending. 
Sort criterion
Entity type
Description
Sort order
Name
PDs, quotes, 
Entity name (string) 
A
ATLAS.ti 6 USER MANUAL
Figure 295: Sort menu for documents
How to C#: Color and Lightness Effects
Geometry: Rotate. Image Bit Depth. Color and Contrast. Cleanup Images. Effect VB.NET How-to, VB.NET PDF, VB.NET Word range is 0 to 255, it will permanently modify
rotate individual pages in pdf reader; pdf rotate one page
SORTING AND FILTERING
386
codes, memos
Author
PDs, quotes, 
codes, memos
Author’s name (string)
A
Created
PDs, quotes, 
codes, memos
Creation date  - or date of 
assignment for PDs. (date/time) 
D
Modified
PDs, quotes, 
codes, memos
Modification date  (date/time)
D
Density
quotes, codes, 
memos 
Quotes, codes: number of links to 
objects of the same type
Memos: number of links to all 
associated objects (i.e., quotes, 
codes, and other memos)
A
Grounded
codes, memos
Number of associated quotations.  A
ID
PDs, quotes
The system generated ID 
(number)
A
Size
quotes, memos
Quotations: number of 
lines/paragraphs
Memos: size 
of text 
A
Media
PDs
Media type  (i.e., audio, image, 
rich text, text, video)
A
Quotations
PDs
Number of quotations for the 
primary document.
D
Usable
PDs
Usability of the primary document D
Origin
PDs
Origin of data source 
(alphabetically)
A
Location
PDs
Redirected path (if used)
A
Start
Quotes
The quotations’ start position
A
Type 
Memos
Memo type (string)
A
PDs
Memos
Number of PDs using the memo 
as their data source (if any).
A
Families
PDs, codes, 
memos
By families in alphabetic order
A
Filtering
The status bar of all Object Managers displays the current filter and sort 
setting. The default filter criterion is "All". 
It is possible to combine filtering and sorting (e.g., all "free" codes sorted by 
the time of their creation).
ATLAS.ti 6 USER MANUAL
Figure 296: Indication of filter setting and sort order in the status bar of object managers
SORTING AND FILTERING
387
The filter options are available in the object menus of the HU Editor 
(Documents, Quotations, Codes, and Memos) and from the corresponding 
Manager’s menu. The filter field in the status bar offers a few additional 
options like reversing or removing the filter. When a filter is active, the 
background color of the affected lists and Object Managers changes. 
The figure below shows the Filter menu for codes with the current filter set to 
All (which is also the default):
After setting a filter, the background color of the affected Object Manager and 
drop-down list changes. You can modify this color by changing the QuickInfo 
color via Windows display preferences. In the figure below, the filter is set to 
abstract codes and the QuickInfo color is set to a darker yellow (under 
Windows preferences). The default color is pale yellow and depending on your 
computer screen, it may be difficult to see.
ATLAS.ti 6 USER MANUAL
Figure 297: Available filters for codes
Figure 298: Code Manager with active filter
Filters affect a 
number of 
procedures
SORTING AND FILTERING
388
An overview of all filter options for all object types is provided below.
Overview of Filter Options 
Option
Entity type
Description incrementally with
immediate feedback after
All
PDs, quotes, codes, 
memos
All objects are displayed (filter off)
Pattern
PDs, quotes, codes, 
memos
Objects matching the entered search 
pattern
Only today’s
PDs, quotes, codes, 
memos
Objects created today
Only mine
PDs, quotes, codes, 
memos
Objects created by the current user
Co-Authors
PDs, quotes, codes, 
memos
Objects created by any of the selected 
co-authors
Families
PDs, quotes, codes, 
memos
Objects belonging to a family
Free
PDs, quotes, codes, 
memos
Objects that do no reference any 
other objects 
Commented
PDs, quotes, codes
Objects bearing a comment 
Selected PD
quotes, codes, memos
Objects referring or belonging to the 
currently selected primary document
PD-Memo
PDs
Memo used as primary document data 
sources
Text 
PDs
Textual primary documents (plain and 
Rich Text)
Rich Text (file) PDs
RTF encoded primary documents
Graphic
PDs
Graphical primary documents 
Audio
PDs
Audio primary documents
Video
PDs
Video primary documents
Uses Mapping
PDs
Redirected primary documents
Renamed
Quotes
Renamed quotations
Hyperlinked
Quotes
Quotations linked to other quotations
Selected code
PD, Quotes
Quotations coded with the currently 
selected code
Abstract codes Codes
Codes without quotations. Less 
selective than "Free"
Super
Codes
Super codes
Types
Memos
Memos of a certain type
Pattern Searches as Filter
Enter a GREP pattern to filter all objects with names matching this pattern.
For example, if you have used names prefixed with “ATT:” for all codes 
handling “attitudes”, the pattern “^ATT:” would filter all those codes (the 
caret character ^  anchors the search at the beginning of the name). 
ATLAS.ti 6 USER MANUAL
SORTING AND FILTERING
389
Enter “\[.*\]” to filter all items containing arbitrary text in brackets.
An overview of the available GREP expressions is listed in the section “GREP
Search” on page 229. 
To Reverse a Filter
Choosing Toggle Filter from the menu or double-clicking the filter field reverses 
the filter. The tilde symbol ~ indicates a negated filter in the status bar.
By reversing the codes filter ‘Abstract,’ you can display all codes that are not 
‘Abstract’. These are all codes that do have quotations associated with them. In 
the filter field you see the entry '~Abstract'.
To Remove or Reset Filters
To deactivate a filter 
either select F
ILTER
: A
LL
from the menu, or 
double-click on the filter field while holding down the Ctrl-key, or 
select E
XTRAS
/ R
ESET
ALL
F
ILTERS
from the main menu.
Filter by Families in the Family Managers
When double-clicking a family in any of the Family Managers, the 
corresponding objects are filtered to the members of the selected family. 
Double-click again to remove the filter.
ATLAS.ti 6 USER MANUAL
Figure 299: Negate a filter by double clicking on the status bar
Press CTRL and 
double-click the 
filter field to 
remove a filter.
GENERATING OUTPUT
390
Generating Output
This chapter provides an overview of all output options that are available within 
ATLAS.ti. In addition, some general procedures common to most output 
functions are explained.
Overview
ATLAS.ti offers numerous options to create output and reports. Most output is 
textual, but numeric or graphical output is also available where applicable 
(Network Editor). Typical textual reports include sorted and filtered lists of 
objects, like code, memos, families and quotations. Comments can often be 
included when needed.
For textual primary documents a near what-you-see-is-what-you-get 
(WYSIWYG) output is available, including the annotations populating the 
margin area.
Output options are available from the menus of the tools, e.g., the HU Editor’s 
menus, the Object Manager’s and Object Explorer’s menus. Some tools offer 
an output button, either as the only option (e.g., the Query Tool) or in addition 
to the menus (Code Manager).
The target of an output is not necessarily restricted to the printer. Many of the 
text-related report procedures allow output to be directed to a text editor, the 
printer, or a file.
Other kinds of output are not necessarily intended to be printed directly but are 
to be processed by other applications, like the SPSS export option, several 
Excel compatible outputs, and HTML and XML export. You can find those 
procedures in chapter “Export & Import” on page 413.
ATLAS.ti 6 USER MANUAL
Documents you may be interested
Documents you may be interested