display pdf from byte array c# : Rotate single page in pdf reader SDK application API wpf html .net sharepoint CCSSandCCBmanual5615-part1388

CHEMCAD Version 5.6 
User’s Guide 
143 
2.  Click on the Edit command on the menu bar.  The Edit menu will open. 
3.  Select the Copy  command  from  the Edit menu.   The  selected objects  will be copied  to the 
clipboard. 
HOW TO GENERATE A DXF FILE 
To generate a DXF file: 
1.  Select the Edit command from the menu bar.  The Edit menu will open. 
2.  Select the Create DXF file option from the Edit menu.  The DXF file will be written to the job 
subdirectory and will have the name <Jobname>.DXF. 
HOW TO DRAW A FLOWSHEET  
Flowsheet creation involves placing unit operations on the screen and connecting them with streams.  
The flowsheet specifies the equipment equations to be solved and what order they are to be solved. 
Drawing a flowsheet involves the following steps: 
1.  Enter the Flowsheet mode.   
2.  Place UnitOps on the flowsheet. 
3.  Connect the UnitOps with Streams. 
4.  Place text and symbols on the drawing (optional) 
STEP 1: ENTER THE F
LOWSHEET MODE 
The Flowsheet  mode  is  the  CHEMCAD  graphics-editing  facility  specifically  designed  for  drawing 
flowsheets. If you are starting a new flowsheet, you will automatically be in the Flowsheet mode when 
you start a new job.  If you are adding to an existing flowsheet, you may have to switch to this mode by 
clicking the Flowsheet command or by selecting the Flowsheet mode from the Change Mode combo 
box on the tool bar.  Either way, whenever you enter the Flowsheet mode the Main Palette will appear.   
Rotate single page in pdf reader - rotate PDF page permanently in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Empower Users to Change the Rotation Angle of PDF File Page Using C#
how to rotate one pdf page; how to rotate a pdf page in reader
Rotate single page in pdf reader - VB.NET PDF Page Rotate Library: rotate PDF page permanently in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
PDF Document Page Rotation in Visual Basic .NET Class Application
rotate pdf pages individually; rotate pdf page
User’s Guide
CHEMCAD Version 5.6 
144 
Each tile contains a symbol that indicates its function.  Most of them represent unit operation icons, but 
others enable the user to: 
• 
Draw streams 
• 
Place text on the drawing 
• 
Draw objects (rectangles, circles, lines, etc.) 
• 
Rotate objects already on the drawing and 
• 
Re-invoke the arrow cursor 
In addition to the palette you will also be using the View command whenever you are drawing flowsheet.  
The View command is located on the menu bar and enables you to control a wide range of graphics 
functions.   
When you click the View command, a menu with the following options will open: 
• 
Zoom Options– To zoom in and out on the flowsheet.   
• 
Toolbar – To switch the toolbar on and off. 
• 
Status bar – To switch the status bar on and off. 
• 
Main Palette – To switch all open palettes on and off while remaining in the Edit Flowsheet 
mode. 
• 
Palette Settings – To specify the size and dimensions of the palettes. 
• 
Grid Visible – To turn the drawing grid on and off. 
• 
Change Grid Size – To specify the grid size. 
• 
Show Page Bounds – Turns the page boundaries on and off. 
• 
Adjust Page Size – Adjust the size of the total available drawing area. 
• 
Stretch Symbol Proportionately – Forces CHEMCAD to stretch the height and width by the 
same percentage amount whenever an object is resized. 
VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
Able to remove a single page from adobe PDF document in VB.NET. using RasterEdge. XDoc.PDF; How to VB.NET: Delete a Single PDF Page from PDF File.
how to rotate all pages in pdf at once; how to rotate a single page in a pdf document
C# PDF Page Delete Library: remove PDF pages in C#.net, ASP.NET
application. Able to remove a single page from PDF document. Ability Demo Code: How to Delete a Single PDF Page from PDF File in C#.NET. How to
rotate individual pages in pdf; rotate pdf pages by degrees
CHEMCAD Version 5.6 
User’s Guide 
145 
• 
Refresh Data Boxes – Updates the Stream, UnitOp, and TP boxes. 
• 
TP Box Visible – Switches the TP boxes on and off. 
• 
Flowsheet Quickview – Switches the Flowsheet Quickview feature on and off. Quickview 
displays popup text when the mouse hovers over a unit op or stream. 
• 
Move/Scale (Simulation Mode) – Allows the user to switch on/off the capability of moving 
and/or resizing flowhseet graphics when CHEMCAD is in Simulation mode. 
• 
Mark Error with color – If checked, the background color of unitop ID numbers will indicate 
errors and warnings.  A red ID number indicates an error; a yellow ID number indicates a 
warning. 
• 
Mark cut streams - Allows the user to switch on/off the capability of coloring recycle / cut 
streams. 
The details of these commands are explained elsewhere in this guide. 
Also available are the following toolbar buttons and combo boxes (from left to right across the toolbar): 
New 
Closes the existing flowsheet and starts a new one. 
Open 
Closes the existing flowsheet and opens another one. 
Save 
Saves the flowsheet and all information associated with it. 
Cut* 
Deletes selected objects and places them on the clipboard. 
Copy* 
Copies selected objects to the clipboard. 
Paste* 
Pastes objects on the clipboard. 
Print 
Print the flowsheet. 
Zoom % 
Zoom in (or out) a specified percent on (or from) the drawing center. 
Zoom In 
To zoom in on a specific area of the flowsheet. 
Zoom out 
To zoom out a previous view or to 50% of the current view. 
Zoom to Fit 
Zooms so that the entire flowsheet exactly fits on the screen. 
Zoom In at a Point 
Zoom in a fixed percent at a specified location on the flowsheet. 
Zoom Out at a Point 
Zoom out a fixed percent from a specified location on the flowsheet. 
Zoom Rectangle 
Zoom in on the area enclosed in a user drawn rectangle. 
Pan Overview 
Pan the entire flowsheet 
Graphics Palette 
Turns the palette(s) on and off even when you are in Flowsheet mode. 
Change Mode combo box 
Switches between the Flowsheet mode, the Simulation  mode, and the 
Main PFD mode. 
* Objects must be selected, in order to use the Cut, Copy and Paste functions. 
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
PDF to images, C#.NET PDF file & pages edit, C#.NET PDF pages extract, copy, paste, C#.NET rotate PDF pages, C# Single page. View PDF in single page display mode
how to reverse page order in pdf; pdf rotate single page reader
How to C#: Basic SDK Concept of XDoc.PDF for .NET
insert, delete, re-order, copy, paste, cut, rotate, and save or query data and save the PDF document. The PDFPage class presents a single page in a PDFDocument
pdf rotate single page and save; pdf rotate pages separately
User’s Guide
CHEMCAD Version 5.6 
146 
These are the tools available to create, edit, review, and print a flowsheet. 
STEP 2: PLACE UNITOPS ON THE FLOWSHEET 
Each unit operations  model is  represented  on  the flowsheet  by  one  or more UnitOp icons.   The 
CHEMCAD Suite supplies a set of “standard” UnitOp icons, but users can create their own.  All available 
UnitOp icons are given a name, attached to a specific Unit Operations model, and included in the main 
palette.  This palette is called using the commands and buttons mentioned above. 
Once a UnitOp icon is placed on the flowsheet, it becomes an object.  All objects can be moved and 
modified using standard Windows conventions. 
When a UnitOp is placed on the flowsheet, CHEMCAD automatically assigns it an ID number and a 
label.  ID numbers are numbered sequentially from 1 and are set inside a small circle that is always 
placed just to the upper left of the icon.  Labels, which may be up to 12 characters, are blank in the 
default condition, and are placed just above the UnitOp number circle.  ID numbers and labels are 
objects themselves and can be moved and edited independently of their UnitOp icon and of each other.  
However, ID number and label positions are considered by CHEMCAD to be relative to the UnitOp icon 
itself.  Therefore, moving a UnitOp icon also moves its ID number and label so as to maintain their 
positions relative to the UnitOp. 
For procedural details on adding UnitOps to a flowsheet, see: 
• 
"How to Add UnitOps to the Flowsheet" 
• 
"How to Move, Modify, Delete, or Duplicate Objects" 
• 
"How to Create User Defined UnitOp Icons" 
STEP 3: CONNECTING UNITOPS WITH STREAMS 
A “Stream” in a process simulator is a list of numbers representing temperature, pressure, vapor fraction, 
enthalpy and the molar flowrates of each of the components.  They serve the following purposes: 
1.  They store some of the input and output for a unit operations module. 
2.  They connect one UnitOp to another in a particular order.  In other words, the outlet stream from 
one UnitOp becomes the inlet stream to another. 
3.  The pattern of their connectivity establishes the calculation order for the simulation. 
Drawing streams on a flowsheet provides an "object" around which these functions can be organized. 
In order to understand how streams are drawn in the CHEMCAD Suite, you should first understand that 
every UnitOp icon consists of some combination of primitives plus “inlet” points and “outlet” points.  All 
streams going into a UnitOp must go to an inlet point.  All streams leaving a UnitOp must come from an 
outlet point.  The position of these points is fixed by whoever builds the UnitOp icon. The CHEMCAD 
Suite knows where these points are, which of them are inlets, and which are outlets.  It will always snap 
streams to one of these positions. 
For convenience, the CHEMCAD Suites identifies inlet positions with blue dots and outlet points with red 
dots on the UnitOps icon.  When you look at the UnitOp icon on the main palette or the sub-palettes, you 
will see these dots.  When you place a UnitOp on the flowsheet, these dots will disappear because they 
would look bad on a flowsheet drawing.  Therefore, to help you find them when you are drawing a 
C# PDF Convert to Tiff SDK: Convert PDF to tiff images in C#.net
Both single page and multipage tiff image files can be created from PDF. Supports tiff compression selection. Supports for changing image size.
pdf rotate page and save; how to rotate all pages in pdf
VB.NET PDF: Basic SDK Concept of XDoc.PDF
insert, delete, re-order, copy, paste, cut, rotate, and save or query data and save the PDF document. The PDFPage class presents a single page in a PDFDocument
rotate one page in pdf reader; pdf rotate all pages
CHEMCAD Version 5.6 
User’s Guide 
147 
stream, the cursor will switch a UnitOp’s dots on and will switch from a cross to a black arrow whenever 
you are close to one of these inlet or outlet points.  Clicking the left mouse button causes the end of the 
stream to snap to the closest “lit” position.   
When drawing streams, you may go from an inlet point to and outlet point or from and outlet point to an 
inlet point.  In both cases you begin the stream by clicking on the desired position when the black arrow 
appears.  To complete the stream you move the cursor (the black arrow) to an “opposite” position (if you 
started the stream at an outlet point, then an inlet is an opposite position and vice versa).  When you are 
close to one, a label will appear describing the position.  To finish the stream, click the left mouse button 
when this label appears.  The stream will snap to this position and an ID number will be assigned to the 
stream.  This ID number can be overridden if desired by right clicking on the stream and using the Edit 
ID command on the menu, which appears.   
To draw a stream: 
1.  Click the Stream button on the main palette.  The palette will disappear and a small cross will 
appear as the cursor. 
2.  Point to the desired position on the UnitOp.  When the black arrow appears at the desired position, 
press the left mouse button.  The cursor will snap to this position. 
3.  Draw the stream over to the destination UnitOp.  If multiple turns are necessary, click the left mouse 
button to fix horizontal and vertical anchors points. 
4.  Point to the position on the UnitOp icon that you want the stream to go to.  When the descriptive 
label appears at the desired position, click the left mouse button.  The stream will snap to this 
position. 
5.  The stream is now drawn, but the Stream cursor is still active.  Therefore, draw any additional 
streams required using steps 1 – 4 above. 
6.  When finished drawing streams, press double click on an unoccupied part of the flowsheet.  The 
main palette will reappear. 
Once a stream is placed on the flowsheet, it becomes an object.  All objects can be moved and modified 
using standard Windows conventions.  For additional information, see: 
• 
"Drawing Streams" 
STEP 4: MODIFYING AND ADDING TO THE FLOWSHEET 
Beyond just placing UnitOps and connecting them with streams, it is possible to add to and change the 
flowsheet in the following ways: 
1.  Place primitives, including text, on the screen. 
2.  Create and add symbols (groups of primitives) to the flowsheet. 
3.  Move, stretch, modify, and/or delete any object. 
4.  Select color and fill schemes. 
5.  Select line patterns. 
See also: 
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
all. This guiding page will help you merge two or more PDF documents into a single one in a Visual Basic .NET imaging application.
rotate single page in pdf reader; how to reverse pages in pdf
C# PDF File Merge Library: Merge, append PDF files in C#.net, ASP.
all those C#.NET PDF document page processing functions To be more specific, two or more input PDF documents can then saved and output as a single PDF with user
reverse page order pdf online; rotate all pages in pdf preview
User’s Guide
CHEMCAD Version 5.6 
148 
• 
"How to Move, Modify, Duplicate and Delete Objects 
• 
"How to Put Text on a Drawing or Plot" 
HOW TO ADD UNITOPS TO THE FLOWSHEET 
To add UnitOps to the flowsheet you must be in the Flowsheet mode.  If the Main Palette is displayed, 
then you are in the Flowsheet mode.  If you are not in the Flowsheet mode, you can get there by click 
the F
lowsheet option in Mod
e on the menu bar or by switch the mode on the Change Mode combo box. 
Once the Main Palette is displayed, you must: 
• 
Select a UnitOp icon from the palette, and 
• 
Place the UnitOp icon on the flowsheet. 
BRIEFLY 
Call the Main Palette by switching to the Flowsheet mode as explained above.  Whenever you start a 
new flowsheet, you will automatically be placed in this mode. 
Point and click on the desired UnitOp square on the palette.  The palette will disappear and a small, 
square cursor will appear.  This cursor is for the placement of the UnitOp icon on the flowsheet as 
indicated by the one-line help at the bottom of the window. 
Position the tip of the cursor where you want the icon to appear, and then click once. 
DETAILS 
Please note the following: 
Since each unit operation can be represented by more than one icon, each unit operation square on the 
Main Palette has one or more sub-palettes from which the icon options can be selected.  
Sub-palettes are called by right clicking on the appropriate square on the Main Palette Therefore, for 
instance, to view all of the available heat exchanger icons, you would first point with the cursor to the 
heat exchanger square on the Main Palette, and then press the right mouse button.  Then all available 
heat exchanger sub-palettes will appear. 
If user added icons exist, then they will appear in a second sub-palette and both sub-palettes will appear.  
The desired UnitOp icon is selected by left clicking on the appropriate square of the sub-palette. 
It is possible to have sub-palettes from different unit operations displayed at the same time.  Right 
clicking on one UnitOp square, say a mixer square, and then right clicking on a different UnitOp square, 
say a pump square, will cause both the mixer and pump sub-palettes to appear.  There is no limit to the 
number of sub-palettes, which may be simultaneously displayed. 
The sub-palette disappears whenever a selection is made from it, or when the user right clicks on the 
corresponding main palette tile again. 
CHEMCAD Version 5.6 
User’s Guide 
149 
Sometimes the icon displayed on the Main Palette is what the user wants to use.  In this case it is not 
necessary to  call the sub-palette.   Simply left  click  the  desired square  and place the icon  on the 
flowsheet. 
When the icon has been selected, the palette will disappear and the Add UnitOp cursor (a small square) 
will appear.  
HOW TO COPY UNITOPS ON THE FLOWSHEET 
To add UnitOps to the flowsheet, you must be in the Flowsheet mode.  If the Main Palette is displayed, 
then you are in the Flowsheet mode.  If you are not in the Flowsheet mode, you can get there by 
clicking the F
lowsheet option in Mod
e on the menu bar or by switching the mode on the Change Mode 
combo box. 
.   
You may copy and paste UnitOps in the current flowsheet.  You may also copy UnitOps and paste them 
into a different flowsheet.  When you paste a UnitOp it has all the settings of the original. 
BRIEFLY 
Select the UnitOp you wish to copy.  You can click-and-drag the mouse to select multiple UnitOps.  You 
can also go to the Edit menu and click Select All to select all UnitOps on the flowsheet. 
To copy the selected UnitOps, either press CTRL + [C] or go to the Edit menu and select copy. 
If you wish to paste the UnitOps (and settings) in another job, close this job and open the destination job. 
Change to edit flowsheet mode. 
To paste the UnitOps, either press CTRL + [V] or go to the edit menu and press paste.  
New copies of the UnitOps will appear on the flowsheet.  The UnitOps will have new numbers.  All 
settings will be the same as the original UnitOps.  You may need to review and change settings, based 
on the new UnitOp numbering system. 
DRAWING STREAMS 
To place streams on the flowsheet click the S
treams tile on the Main Palette   
User’s Guide
CHEMCAD Version 5.6 
150 
There are a few general rules to remember when drawing streams on the flowsheet: 
• 
Each stream goes from a source unit to a destination unit. 
• 
Each unit has inlet and outlet positions.  These are established when the symbol is created.  
The program always snaps streams to these positions.  During the simulation a process stream 
always "flows" from an outlet position on a source unit to an inlet position on a destination unit.  
When drawing the flowsheet, a stream may be drawn in any direction: from an inlet position to 
an outlet position as well as from an outlet position to an inlet position. 
• 
When starting a stream, the cursor will be a small cross.  When the cursor get near an inlet or 
outlet position, this cursor will convert to a black arrow.  At the same time the UnitOp inlet and 
outlet points will be deployed.  When this occurs, you should left click the mouse to start the 
stream if that is the position you desire. 
• 
When completing the stream, the cursor will remain as a black arrow.  When the cursor is near 
a proper inlet or outlet position, the UnitOp inlet and outlet points will appear and a label will 
appear.  Obviously, if a stream was started at an inlet point, it must be connected to an outlet 
point. 
• 
Once the desired position has been located (as indicated by the appearance of the label), you 
should left click the mouse to complete the stream. 
• 
While drawing a stream, the palette will disappear.  It will reappear only when you left click 
somewhere on the flowsheet, which is not a UnitOp inlet or outlet point.  You are not
required to 
click the stream (link) icon square each time you begin a stream. 
• 
You can alternate between placing UnitOps on the screen and connecting them with streams as 
long as the above rules are followed. 
CHEMCAD Version 5.6 
User’s Guide 
151 
The first time you change directions of a stream; CHEMCAD will let you do so without any problem.  
Every additional time you change directions, you must first press the left button on the mouse to identify 
the longitude or latitude through which you want the stream to pass.  Doing this will create an anchor 
point to fix the longitude or latitude on the screen.  
DRAWING SIMPLE STREAMS (ONE OR LESS DIRECTION CHANGE) 
To draw a simple stream with one or less direction changes, that is, a stream that does not require 
anchor points, use the following procedure: 
Click the Streams icon box on the palette.  The palette will disappear and the crosshairs cursor will 
appear.   
Move the cursor close to either an inlet point or an outlet point on a unit operation icon.  When the cursor 
switches to a black arrow, press the left button on the mouse.   
Draw the stream over to an opposite point on another unit operation icon.  In other words, if you started 
with  an inlet  point  on  the starting  unit operation, draw  the  stream  over  to  an  outlet  point on the 
destination unit operation icon, and vice versa.  When the label for the desired point appears, press the 
left button on the mouse.  CHEMCAD will draw the stream directly to that point and will place a stream 
ID number on the flowsheet. 
CHEMCAD issues ID numbers sequentially.  You may change it using the Edit Stream menu (right click 
the stream) if you would like to do so. 
DRAWING COMPLEX STREAMS (MULTIPLE DIRECTION CHANGES) 
To draw streams that change direction more than once, use the following procedure. 
Click the Streams icon box on the palette.  The palette will disappear and the crosshairs cursor will 
appear.   
Move the cursor close to either an inlet point or an outlet point on a unit operation icon.  When the cursor 
switches to a black arrow, press the left button on the mouse. 
Draw the stream as you normally would, but before you make your second turn, move the cursor to the 
longitude or latitude at which you wish to force the stream to pass through.  Then click the left button on 
the mouse.  A small circle will appear indicating the position of the anchor point. 
Repeat step 3 for each additional change in direction. 
When desired, move the cursor close to the desired destination inlet or outlet point.  When the label 
appears, left click the mouse.  The stream will then be complete. 
HOW TO SELECT COMPONENTS FOR THE COMPONENT LIST 
In order to select components for the component list, you must first call the Component Selection 
dialog box, and then use that dialog box to select the components from those stored in any of the 
available CHEMCAD physical properties databanks.  To call the Component Selection dialog box, you 
must select it from the ThermoPhysical menu or click on the Define Components button on the tool 
bar. 
User’s Guide
CHEMCAD Version 5.6 
152 
CALLING THE COMPONENT LIST DIALOG BOX 
From the main menu bar: 
a.  Select the ThermoPhysical
command on the main menu bar.  You can do this two ways. 
• 
Point and click ThermoPhysical
with the mouse, or 
• 
Press [ALT + L] on the keyboard. 
The ThermoPhysical menu will open up like so: 
b.  Select the Component L
ist option from the menu.  This can be done in two ways: 
• 
Point and click Component L
ist with the mouse, or 
• 
Press the [L] key  (Note: press [L] not [ALT + L].) 
From the Tool Bar: 
Click on the Define Components button 
USING THE COMPONENT LIST DIALOG BOX 
The Component Selection dialog box looks like this: 
Documents you may be interested
Documents you may be interested