CHEMCAD Version 5.6 
User’s Guide 
153 
BRIEFLY 
To select components from the component databank list in the right-hand window of the dialog box you 
should: 
1.  Locate the desired component by scrolling through the list.  You can scroll by using: 
• 
the elevator bar 
• 
the arrow keys 
• 
the [PgUp] and [PgDn] keys 
• 
the Search field in the lower center of the dialog box 
2.  Select the component by: 
• 
highlighting it and clicking the Add button 
• 
highlighting it and hitting the [Enter] key 
• 
double clicking on the component 
DETAILS 
There are eight (8) functional parts to this dialog box.  These are: 
1.  The Selected Components area in the upper left portion of the dialog box.  This area will display 
the components that have already been selected (if any).  This area is normally dormant, but it can 
be activated by  clicking anywhere on  it.  When active, a highlight will appear over one of the 
components.  The Selected Components area is activated only when you want to insert or delete 
components. 
2.  The Component Databank area is in the upper right hand portion of the dialog box.  This displays a 
list of all the components in any of the databases, which are currently accessible to CHEMCAD.  
The actual component selections are made from here either by double clicking on the component 
desired or by highlighting it and pressing the Add button. 
The highlight can be moved by single clicking the mouse on the desired component; by using the 
elevator bar; by using the arrow[PgUp], or [PgDn] keys; or by typing in an identifying string in the 
Search Component field described below. 
Components  with ID  numbers between  1  and 5,000  are  from the CHEMCAD Suite database.  
Components 6,001 – 8,000 are from the corporate pool database.  Components from 8,001 – 9,999 
are from the local user database.  Components 5,001 – 6,000 are for pseudo-components. 
3.  The Search Component option is in the lower right portion of the dialog box.  Typing in this field 
causes the program to scroll through the Component Databank list to find the alphanumeric string 
you typed.  Some strings are embedded in more than one component (e.g., "ethanol" is in methanol 
and ethanol, as well as others).  If the first component that the program finds is not the one you 
want, you can then press the Next button to try the next component found.  Continue until you find 
the correct component. 
4.  The A
dd (Add new components) button is in the lower left-hand portion of the dialog box.  This 
option allows the user to add components to the bottom of the current job component list.  You can 
Rotate pdf pages by degrees - rotate PDF page permanently in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Empower Users to Change the Rotation Angle of PDF File Page Using C#
save pdf after rotating pages; save pdf rotated pages
Rotate pdf pages by degrees - VB.NET PDF Page Rotate Library: rotate PDF page permanently in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
PDF Document Page Rotation in Visual Basic .NET Class Application
rotate a pdf page; save pdf rotate pages
User’s Guide
CHEMCAD Version 5.6 
154 
invoke this option by highlighting the desired component, then clicking the Add button with the 
mouse or by pressing the alternate [A] key.  Of course, an alternate way to add components to the 
component list is to double click on the desired component. 
5.  The I
nsert button is in the lower left-hand portion of the dialog box just above the Search 
Component field.  This option allows the user to insert components from the database anywhere in 
the current component list.  To use this option, follow the procedure given below. 
• 
Identify the position in the component list where you want the new component inserted.  Do this 
by highlighting the component which currently occupies that position. 
• 
Select the new component from the Component Databank list.   
• 
Click the Insert button.  The new component will appear, highlighted, in the component list.  All 
components below the inserted component will move down one position. 
6.  The D
elete button is in the lower left-hand portion of the dialog box.  This option allows the user to 
delete components from the component list.  To use this option, follow the procedures given below: 
• 
Highlight the component to be deleted. 
• 
Click the Delete button or press the [Alt + D] key. 
7.  The Clear button simply deletes all of the components in the list at once. 
8.  The Copy components from another job button is in the lower left-hand portion of the dialog box,. 
This option allows the user to easily create a components list by copying it from another CHEMCAD 
job. 
When finished making selections, press the [OK] button to save your work or [Cancel] to cancel your 
changes.
HOW TO SELECT K-VALUE OPTIONS 
To make K-value model selections, you must call the K-value Options dialog box. 
BRIEFLY 
1.  Click the K-Value Power Button on the Tool Bar.    
2.  The K-value Options dialog box will appear. 
K-Value button
n
C# TIFF: How to Rotate TIFF Using C# Code in .NET Imaging
C#.NET PDF pages extract, copy, paste, C#.NET rotate PDF pages, C#.NET VB.NET How-to, VB.NET PDF, VB.NET Word, VB In general, you are able to rotate any page of
pdf page order reverse; how to save a pdf after rotating pages
C# PDF: PDF Document Viewer & Reader SDK for Windows Forms
Roate90: Rotate the currently displayed PDF page 90 degrees clockwise. Rotate180: Rotate the currently displayed PDF page 180 degrees clockwise.
rotate pages in pdf permanently; rotate all pages in pdf and save
CHEMCAD Version 5.6 
User’s Guide 
155 
3.  Open the Global K-value Option list in the upper left by clicking on the field. 
4.  Scroll this list until the desired K-value model is displayed. 
5.  Select the desired model by clicking it with the mouse. 
6.  Make any supplementary selections (presented in the rest of the dialog box). 
7.  Close the K-value Options dialog box by clicking [OK]
8.  You will be asked if you want to reinitialize all of the streams.  If you are unsure, click [YES]. 
DETAILS 
1.  The K-value Option dialog box is called in this way: 
From the main menu bar, select the ThermoPhysical
command by clicking it with the mouse, or 
pressing the [ALT + L] keys. 
The ThermoPhysical
menu will appear.  From the ThermoPhysical
menu, select the K
-values 
option by clicking it with the mouse, or pressing the [K] key. 
The K-value Options dialog box will appear. 
2.  Description of the K-value Options dialog box options. 
Global  K-value  Options: This field provides a list of all the K-values models offered in the 
CHEMCAD Suite.  A selection from this list becomes the basic, global (i.e., applied to all UnitOps in 
the simulation) K-value model for the active flowsheet.  Certain options within the basic selection 
can be invoked using the fields described below. 
Procedure:
• 
To open the K-value models list, click on it with the mouse. 
• 
The list is scrollable using the elevator bar, the [PgUp] and [PgDn] keys, and the arrow keys.  
Scroll the list until the desired model is displayed. 
VB.NET TIFF: Rotate TIFF Page by Using RaterEdge .NET TIFF
formats are: JPEG, PNG, GIF, BMP, PDF, Word (Docx reImage1, 100) REFile.SaveImageFile( reImage1, "c:/rotate.png", New TIFF page(s), reorder TIFF pages ordered or
rotate pdf page by page; rotate pdf page permanently
C# Word: C#.NET Word Rotator, How to Rotate and Reorient Word Page
to rotate all MS Word document pages by 90 viewer application which can help me rotate Word page by powerful & profession imaging controls, PDF document, image
how to rotate one page in a pdf file; rotate individual pdf pages reader
User’s Guide
CHEMCAD Version 5.6 
156 
• 
Select the desired model by clicking it with mouse, or by highlighting it, then pressing the 
[ENTER] or [TAB] keys. 
The following K-value dialog box options are choice boxes.  Click the appropriate selection.  (For a 
description of how to use choice boxes in CHEMCAD, please refer to Using dialog boxes/Making 
choice box selections.) 
Ethane/Ethylene, Propane/Propylene 
Allows  you  to  select  whether you  want  to  use  standard  BIPs  or specially  fitted  BIPs  for  the 
ethane/ethylene and propane/propylene pairs when using the SRK or Peng-Robinson equations of 
state.  Typically, the special BIPs will give the best results near the critical points. 
Vapor Phase Association 
Certain compounds, especially carboxylic acids, have the tendency to dimerize or even polymerize 
in the vapor phase.  You can ask CHEMCAD to take this effect into account by activating this option. 
Vapor Fugacity/Poynting Correction 
When using a liquid activity coefficient K-Value method, you may treat the vapor phase as an ideal 
solution or as a regular solution.  The latter requires use of the vapor fugacity Poynting correction.  
In the default condition, CHEMCAD assumes the vapor phase is an ideal solution.  This is the No 
Correction option.  If you want the Poynting correction included in the calculation, you must select 
the Correction option.  In such cases, the vapor fugacity will be calculated using the SRK equation 
of state.  Typically, it is safe to ignore this correction at lower operating pressures. 
Alpha Function 
For SRK and Peng-Robinson EOS models, you are allowed to choose either the standard alpha 
function or the newer Boston-Mathias alpha function.  The default is the standard alpha function. 
Global Phase Option 
The default, vapor/liquid/solid, does not account for the possibility that two liquid phases may be 
present.  If you want CHEMCAD to perform rigorous calculations for a second liquid phase, then the 
vapor/liquid/liquid/solid  option  should  be  used.    This  option  only  applies  to  activity  coefficient 
methods capable of predicting a second liquid phase. For a hydrocarbon / free water decant system, 
use the water hydrocarbon solubility option. 
Water/Hydrocarbon Solubility 
In the default condition, water will be treated as miscible for K-value options SRK, PR, API SRK, 
ESSO, and Grayson-Streed.  In this case, the K-values for all the hydrocarbons present will be 
calculated by the method selected, but the K-value of water will be calculated by a special routine 
that accounts for the solubility of water in the hydrocarbons.  Liquid water which is not calculated as 
soluble in hydrocarbon will exist as a separate ‘free water’ liquid phase. This option only applies to 
Equations of State. 
Salt Position for Wilson Model 
Enter the position in the component list of the compound designated as the salt if using the Wilson 
Salt Effect K-value option. 
No. of BIP Sets 
CHEMCAD allows you to have up to ten (10) sets of BIPs for each activity coefficient method.  This 
gives you the flexibility of using one set of BIPs in one section of a flowsheet and a different set in 
another.  A typical use of this would be when you know that two liquid phases exist in the condenser 
VB.NET Word: VB.NET Code to Rotate Word Page Within .NET Imaging
Here, we can recommend you VB.NET PDF page rotating tutorial and multi 0 to 360 degrees using VB code; Able to rotate multiple desired Word pages at the
rotate pdf pages on ipad; rotate pdf page and save
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit PDF
web viewer, users can click rotation button to rotate PDF page 90, 180 and 270 degrees in clockwise erase PDF text, erase PDF images and erase PDF pages online
rotate pdf pages and save; pdf save rotated pages
CHEMCAD Version 5.6 
User’s Guide 
157 
of a distillation column.  You can choose to use NRTL LLE BIPs in the condenser and NRTL VLE for 
the rest of the column. 
Default BIP Set 
Defines the set to be used globally by the program. Unless you specify a local bip set, this set is 
used for calculations. 
Clear Local K Model? 
Click on this field if you wish to reset all local K-value models back to the global K-value model. 
Set Local K/BIP Model? 
If you click on this field, the program will then go into an equipment selection mode when you close 
the K-value Options dialog box.  The user can then define what K-value model or BIP set is 
applicable to the particular unit operation.  
Set Tray BIP? 
If the user clicks on this field, upon exiting the K-value dialog box, the program will go into selection 
mode and allow you to choose one or more distillation towers from the flowsheet.  It will then 
present you with an input screen where you can enter a range of tray numbers and the BIP set that 
applies to that range. 
Set Henry’s Components 
When using an activity coefficient model, the K-value for super critical (temperature) components is 
calculated using the Henry’s Gas Law equation.  Selecting this option instructs CHEMCAD to use 
Henry’s Gas Law for the component at all temperatures. 
HOW TO SELECT ENTHALPY OPTIONS 
To make enthalpy model selections, you must call the Enthalpy Options dialog box.   
BRIEFLY 
1.  Click the Enthalpy button on the toolbar. 
2.  The Enthalpy Options dialog box will appear. 
Enthalpy button 
Customize, Process Image in .NET Winforms| Online Tutorials
Click "Flip Vertical" to rotate images 180 degrees vertically; More Tutorials! Find more user guides with RasteEdge .NET Image in .NET Winforms applications!
rotate pages in pdf; reverse page order pdf
Process Images in Web Image Viewer | Online Tutorials
the order of images & file pages by dragging & used document types are supported, including PDF, multi-page This JavaScript API is used to rotate the current
how to rotate page in pdf and save; how to rotate pdf pages and save permanently
User’s Guide
CHEMCAD Version 5.6 
158 
3.  Open the Global Enthalpy Option: field in the upper left by clicking on it.  It should open up a list. 
4.  Select the desired model by clicking it with the mouse. 
5.  Make any supplementary selections (presented in the rest of the dialog box). 
6.  Close the Enthalpy Options dialog box by clicking [OK]. 
7.  Upon exiting this dialog box, you will be asked if you want to reinitialize all of the streams (if any 
exist).  If you are unsure about this, click [YES]. 
DETAILS 
1.  The Enthalpy Option dialog box is called: 
From the toolbar by clicking on the Enthalpy button, or 
From the main menu bar select the ThermoPhysical
command by: 
-  Clicking it with the mouse, or 
-  Pressing the [ALT + L] keys. 
The ThermoPhysical
menu will appear. 
From the ThermoPhysical menu, select the E
nthalpy option by clicking it with the mouse. 
The Enthalpy Options dialog box will appear. 
2.  The Enthalpy Options  dialog box options. 
Procedure:
• 
To open the Global Enthalpy Options list, click on it with the mouse. 
• 
Select the desired model by clicking it with the mouse, or highlighting it, then pressing the 
[ENTER] or [TAB] keys. 
Global Enthalpy Options: The Global Enthalpy option is a combo box.  This field provides a list 
of all the enthalpy models offered in CHEMCAD.  A selection from this list becomes the basic, global 
(i.e., applied to all UnitOps in the simulation) enthalpy model for the active flowsheet.  Certain 
options within the basic selection can be invoked using the fields described  below.   Click the 
appropriate selection.  For a description of how to use combo boxes in CHEMCAD, please refer to 
Using dialog boxes. 
Ideal Gas Heat Capacity: 
Choose  between two  equation  forms  (Polynomial  or  DIPPR)  for  calculation  of  ideal  gas  heat 
capacity.  A description of these forms is given in the on-line manual. 
The remaining entries in Enthalpy Options dialog box are optional. 
Use Heat of Solution File? 
If you have a file that contains heats of solution data, then you must click on this field to inform the 
program to look for the file with the HTS extension. 
C# Image: C# Image Web Viewer Processing Tutorial; Process Web Doc
Basic .NET program and process web pages within image In order to rotate a current web image or powerful & profession imaging controls, PDF document, tiff
saving rotated pdf pages; pdf reverse page order online
CHEMCAD Version 5.6 
User’s Guide 
159 
Use electrolyte enthalpy:  
The electrolytes model contains an enthalpy model to compensate for heat of dissociation.  This 
check box allows the user to turn off enthalpy effects of dissociation if an electrolytes model is in 
use.  This setting has no effect on non-electrolytes models.  
Clear all Local H Model? 
A checkmark in this field will reset all local enthalpy models back to the global setting. 
Specify Local H Model? 
Allows you to select different enthalpy models for different unit operations in the flowsheet.  A 
checkmark in this field will allow you to pick individual equipment on the flowsheet and set specific 
enthalpy models for each one. 
Heat of Mixing by Gamma? 
This option includes the heat of mixing in the heat balance.  The heat of mixing is computed from 
activity coefficient. 
Compressed water pressure correction for steam table at very high pressure the enthalpy of 
water requires some correction to the normal IFC equation which is normally used to calculate water 
enthalpies.  Under these conditions, this correction can cause a significant difference in the enthalpy 
of a water stream. 
HOW TO DEFINE THE FEED STREAMS 
BRIEFLY… 
1.  Double-click on the desired stream (not the stream number box).  The Edit Streams dialog box will 
appear. 
2.  Complete the dialog box as required. 
3.  Save the data by clicking [OK]
User’s Guide
CHEMCAD Version 5.6 
160 
DETAILS… 
1.  The Edit Streams dialog box can be called in ways: 
• 
By double-clicking the appropriate stream on the flowsheet. 
• 
By clicking the Edit feed streams button on the toolbar. 
• 
By using the S
pecifications command on the main menu bar. 
• 
By right clicking on the stream. 
Double clicking the appropriate stream on the flowsheet will immediately call the Edit Streams 
dialog box for the stream selected. 
Clicking the Edit feed streams button on the toolbar will immediately call the Edit Streams 
dialog box for every feed stream on the flowsheet. 
Right clicking the streams a menu will appear.  Select the “Edit Stream” option on the menu. 
Using the S
pecifications command on the main menu bar to call the Edit Streams dialog box 
is done by following the procedure given below: 
• 
Select the S
pecifications on the menu bar command by: 
-  Clicking on it, or 
-  Pressing [ALT + S] on the keyboard. 
The Specifications menu will appear.   
• 
From the Specifications menu select either the F
eed streams or the S
elect streams option 
by clicking or by pressing the underlined letter.   
Selecting the Feed streams option will immediately call the Edit Streams dialog box for every 
feed stream on the flowsheet. 
Selecting the Select streams option will cause the Select Streams dialog box to appear.  This 
dialog box is used to identify the feed streams.  This can be done either by using the mouse to 
click on the desired streams, or by typing the stream ID numbers (separated by spaces) of the 
flowsheet feed streams.  If you use the mouse, the stream number will appear in the dialog box 
field as you click each stream.  When all the required streams have been selected, click the 
[OK] button in the dialog box.  The Edit Streams dialog box will appear. 
2.  Complete the dialog box: 
Note the following points about this dialog box. 
• 
The first field, called Stream Name allows you to enter a stream label or name.   
Note:  Entering and/or editing such stream labels can also be done a number of other 
ways. 
• 
The next four fields; temperature, pressure, vapor fraction, and enthalpy are the thermodynamic 
properties of the stream.  According to the Gibbs phase rule, once the composition is given, 
specifying any two of the four thermodynamic properties of a mixture will define the other two.  
CHEMCAD Version 5.6 
User’s Guide 
161 
Thus, defining the composition, temperature, and pressure uniquely defines the vapor fraction 
and enthalpy (again, this is for a mixture only).  Alternately, defining the composition, pressure, 
and enthalpy will uniquely define temperature and vapor fraction. 
CHEMCAD, however, by convention, does not permit this much freedom.  Since enthalpies are 
calculated relative to a datum, the calculation of any  given stream enthalpy is an involved 
process which is prone to errors.  For this reason, CHEMCAD does not permit you to enter 
stream enthalpy.  (There is one exception to this rule; when the total component flowrate of a 
stream is zero, entering an enthalpy in a stream may serve as an alternative way of adding a 
heat duty to a unit.) 
Therefore, to uniquely define any stream in the CHEMCAD Suite, the user must define the 
composition of that stream, and any two of temperature, pressure, and vapor fraction.   
• 
The fields Total Flowrate Units and Component Flow Units work together to provide the user 
with a variety of ways to define stream compositions.  If the Component Flow Units are set to 
mole, mass, or volume fraction (which can be done globally or locally) then the Total Flowrate 
Units menu will become available.   
If Component Flow Units is set as a flow or amount option, then the total flowrate becomes the 
sum of the component flowrates and the Total Flowrate Units menu will “gray out” and therefore 
be unavailable for editing.  In this situation, as the component flowrate values are entered, they 
are automatically summed and the current sum is displayed in the field labeled Total Flowrate. 
• 
In the top left of the dialog box is the [Flash] button .  Clicking this button at anytime will cause 
the  program  to  perform  a  flash  calculation  using  the  currently  specified  composition  and 
thermodynamic properties.  This allows quick flash calculations to be made without exiting the 
dialog box. 
• 
Fractions that do not sum to 1.0 are automatically normalized upon flashing or exiting the dialog 
box. 
3.  Click the [OK] button.  This will close the dialog box and simultaneously save the data.  CHEMCAD 
will automatically perform a flash calculation on the stream before saving the data. 
HOW TO SPECIFY UNIT OPERATIONS 
In CHEMCAD, you specify the feed streams and settings for the unit operations.  When CHEMCAD 
calculates the feed stream to a  unit is  used, along with  the specifications, to calculate the outlet. 
Specifications are made at the UnitOps, not at the exit streams. 
For each UnitOp in the CHEMCAD library, there is a corresponding, unique dialog box for specifying its 
operation.  These dialog boxes are the means by which: 
1.  The user provides the specifications necessary to match the degrees of freedom present in the 
flowsheet.  This step is necessary for a unique solution to exist. 
2.  Certain options, which are not essential to a unique solution, are exercised. 
Before running a simulation, it is necessary that the UnitOp dialog boxes be completed properly. 
User’s Guide
CHEMCAD Version 5.6 
162 
For a description of each item of each UnitOp dialog box, please refer to the Help system. 
CALLING A UNITOP DIALOG BOX 
UnitOp dialog boxes may be called in the following ways: 
1.  Double-click the UnitOp icon itself on the flowsheet, or 
2.  Right click on the UnitOp and select the “Edit Unit Op Data” option from the menu that appears. 
3.  From the main menu bar: 
• 
Select S
pecifications from the menu bar.  The Specifications menu will open. 
• 
Select the Select Unit
option from the Specifications menu.  The Select UnitOp(s) dialog box 
and cursor will appear. 
• 
Identify which UnitOp dialog boxes are to be called by clicking the UnitOp icons or by typing the 
UnitOp ID number in the dialog box. 
After all desired UnitOps have been identified, click [OK].  The first UnitOp dialog box will appear.  Other 
selected UnitOp dialog boxes will appear as the prior dialog boxes are closed.  Appearance will be in the 
order of selection. 
RULES FOR COMPLETING THE UNITOP DIALOG BOXES 
The rules for using UnitOp dialog boxes are described in the section “Using Dialog Boxes” of this 
manual. 
DEGREES OF FREEDOM AND UNITOP DIALOG BOXES 
Generally speaking, each time a unit operation is added to the flowsheet, it adds one or more degrees of 
freedom to the simulation.  The number of degrees of freedom created depends upon the UnitOp itself.  
Most UnitOps will create one, but many will add more.  For each degree of freedom created, one 
specification must be made for a unique solution to exist.  
Since CHEMCAD is a modular sequential simulator, the specification must be made at the UnitOp that 
created the degree-of-freedom.  For example, a two-outlet distillation column with a condenser and 
reboiler creates two degrees of freedom when added to the flowsheet.  Therefore, two specifications 
must be made in the column dialog box. 
If the user provides either too many or too few specifications, CHEMCAD will issue an error message to 
that effect when exiting the dialog box.  Errors such as these must be corrected before the simulation 
can be run. 
As a guideline dialog boxes in the CHEMCAD Suite show critical data for UnitOps in green.  
HOW TO RUN SIMULATIONS IN THE CHEMCAD SUITE 
There  are  four  “categories”  of  simulation  runs  in  the  CHEMCAD  Suite.    These  are  steady  state 
simulation, optimization, sensitivity analysis, and dynamics simulation.  All four are run from the R
un 
command on the menu bar. 
Documents you may be interested
Documents you may be interested