display pdf from byte array c# : Save pdf rotated pages control Library system azure .net web page console CCSSandCCBmanual5620-part1394

CHEMCAD Version 5.6 
User’s Guide 
193 
• 
Packed Column Sizing – Generates a report of column sizing for packed columns. 
• 
Tray  Compositions – This allows you to select what units to use on the tray-by-tray 
composition report.  If “No Tray Compositions” is specified, this report is omitted. 
HEATING CURVES 
This option sets the parameters for heating curves.  This involves defining how many points are desired 
on the curve and whether the cuts should be based on temperature [Default] or enthalpy.  Selecting the 
Heating Curves option calls the Heat Curves dialog box. 
No. of points: Enter the number of points used to calculate the heating curve.  The number of zones 
equals the number of points minus one. 
Cutting Method option: Click the desired option (only one permitted). 
• 
Temperature cut means points will be at intervals of equal temperature. 
• 
H cut with dew/bubble points means that intervals of equal enthalpy are used between the 
dew and bubble points (if present).   
• 
Equal H cut means that the points are at intervals of equal enthalpy.  The dew and bubble 
points are not located or used. 
BATCH/DYNAMIC RESULTS 
This option allows you to include time dependent output for batch columns, batch reactors, and dynamic 
vessels.  It calls the Batch/Dynamic Options dialog box. 
Save pdf rotated pages - rotate PDF page permanently in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Empower Users to Change the Rotation Angle of PDF File Page Using C#
rotate single page in pdf reader; rotate a pdf page
Save pdf rotated pages - VB.NET PDF Page Rotate Library: rotate PDF page permanently in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
PDF Document Page Rotation in Visual Basic .NET Class Application
pdf reverse page order preview; reverse page order pdf
User’s Guide
CHEMCAD Version 5.6 
194 
• 
For batch distillation,  you  may  select  print Operation Results  (stream  compositions  and 
temperatures  at  the  end of each  operation step):  print History  (stream  compositions  and 
temperatures  at  each  time  increment);  or  print Final Holdups  (stage  compositions  and 
temperatures for each time increment. 
• 
For batch reactors,  you  may print Operations Results  and/or Stream and Reactor Mass 
Histories. 
• 
For dynamic vessels, you may print Operations Results and/or Stream and Vessel Mass 
Histories. 
• 
For individual streams, you may print the composition and temperature Histories. 
• 
For each piece of equipment, you may print the equipment output Histories
MISCELLANEOUS 
Enables the user to toggle on and off the following sections of the output report: 
 Topology summary 
 Convergence selections 
 Thermodynamics selections 
 Line sizing results 
In the default condition these items are included
in the report. 
END REPORT 
Exits the report module. 
VB.NET TIFF: Rotate TIFF Page by Using RaterEdge .NET TIFF
specific formats are: JPEG, PNG, GIF, BMP, PDF, Word (Docx Save the rotated page(s) to new a TIFF Multiple image formats support for saving rotated TIFF page(
how to rotate one page in a pdf file; pdf expert rotate page
VB.NET Image: Image Rotator SDK; .NET Document Image Rotation
VB.NET image rotator control SDK allows developers to save rotated image as are dedicated to provide powerful & profession imaging controls, PDF document, tiff
save pdf rotate pages; saving rotated pdf pages
CHEMCAD Version 5.6 
User’s Guide 
195 
HOW TO CREATE PFD’S 
A PFD is a process flow diagram.  It usually consists of: 
i.  The flowsheet drawing 
ii.  The tabulated heat and material balance and/or stream properties (Stream Box). 
iii.  Tabulated unit operation information (UnitOp Box). 
iv.  TP boxes on the streams (TP Box). 
v.  A title block. 
vi.  Miscellaneous notes regarding the process. 
vii.  The company logo. 
Item (i) above is created when you draw the flowsheet. 
Item (ii) above is called a Stream Databox.  CHEMCAD has a special function for creating stream 
databoxes.  That function is called by selecting the Add Stream Box command located on the Format 
menu. 
Item (iii) above is called a UnitOp databox.  CHEMCAD has a special function for creating UnitOp 
databoxes.  That function is called by selecting the Add UnitOp Box command located on the Format 
menu. 
Item (iv)  above  allows  the  user  to  place  small boxes  containing the temperature  pressure, and/or 
flowrate of a stream or that stream and/or the flowsheet.  This function is called by selecting the Add TP 
Box command located on the Format Menu
Item (v) above is a symbol within CHEMCAD.  A title block is provided by CHEMCAD, but users may 
create their own.  The title block is stored as a tile on the PFD palette.  From there it can be called and 
placed on the PFD. 
Item (vi) above is created using the text function on the PFD Palette. 
Item (vii) above is accomplished by using the Import Bitmap  function located on Format menu. 
Multiple PFD’s can be created for each flowsheet.  Instructions on how to create and edit PFD’s are 
provided below. 
CREATING THE MAIN PFD 
The Main PFD is the PFD created using the Main PFD command on the Output Menu or by choosing 
the Main PFD option from the Change Mode combo box on the tool bar.  The Main PFD is different from 
all other PFD’s in that, once it is created, it is always displayed even when not in PFD mode.  Other 
PFD’s are displayed only when you are in PFD mode.  If you do not want your PFD to always be 
displayed, you should create it using the New PFD command, not the Main PFD command.  Obviously, 
there can be only one Main PFD per flowsheet, while there can be as many other (non-main) PFD’s as 
desired. 
The general procedure for creating Main PFD’s (process flow diagrams) is: 
C# TIFF: How to Rotate TIFF Using C# Code in .NET Imaging
VB.NET How-to, VB.NET PDF, VB.NET Word, VB Tiff page, like sorting and saving the rotated Tiff page 0); page.Rotate(RotateOder.Clockwise90); doc.Save(@"C:\rotate
rotate all pages in pdf file; pdf reverse page order
How to C#: Rotate Image according to Specified angle
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Excel, VB.NET PowerPoint, VB.NET Tiff, VB.NET Imaging, VB.NET OCR, VB.NET Twain, VB Save the rotated image to
rotate individual pdf pages reader; how to rotate a pdf page in reader
User’s Guide
CHEMCAD Version 5.6 
196 
1.  Select the O
utput command on the Simulate Flowsheet menu bar.  The Output menu will appear. 
2.  Select the Main PFD option from this menu.  A new palette, the PFD Palette, will open and the 
program will go into “PFD mode”.  The PFD Palette is a modified graphics-editing palette and, as 
such, most of its functionality is described in the section “Drawing with the Palette”.   
Optionally you may bypass steps 1 and 2 by choosing the Main PFD option from the Change Mode 
combo box on the tool bar.  
3.  Create the PFD by: 
• 
Adding S
tream and U
nitOp databoxes, 
• 
Adding TP Boxes, 
• 
Adding simulation data from Excel data ranges, 
• 
Adding Title Blocks, symbols, and text, 
• 
Drawing primitives, moving objects, changing colors, etc., as desired. 
4.  Print the PFD as desired. 
5.  Exit the PFD mode to reopen the simulation mode commands.  The main PFD will remain on the 
screen. 
See also: 
• 
"Adding a Stream Databox on the PFD" 
• 
"Adding a UnitOp Databox on the PFD" 
• 
"Adding TP Boxes to the PFD 
• 
“Adding Excel Ranges to the PFD” 
• 
"How to put text on a drawing" 
• 
"How to move or modify an object" 
• 
"Importing Bitmap" 
CREATING SECONDARY PFD’S 
A secondary PFD is any PFD, which is not a Main PFD.  For any given flowsheet a user may have as 
many secondary PFD’s as he/she pleases.  Secondary PFD’s are not displayed when the program is in 
Flowsheet Mode or Simulation Mode.  It is not necessary to have a main PFD in order to have 
secondary PFD’s. 
The general procedure for creating Secondary PFD’s (process flow diagram) is: 
1.  Select the O
utput command on the Simulate Flowsheet menu bar.  The Output menu will appear. 
2.  Select the New PFD option from this menu.  The Open dialog box will appear. 
3.  Enter a name for the PFD in the File name field of the Open dialog box
VB.NET Imaging - Data Matrix Plug-in SDK Control
Generated Data Matrix barcode image can be freely rotated, resized and code page.AddImage(image, New PointF(100F, 100F)) docx.Save("C:\\Sample_Barcode.pdf").
rotate pages in pdf permanently; permanently rotate pdf pages
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit OpenOffice
documents, CSV file and Text file are allowed to be rotated. PowerPoint (.ppt, .pptx) on webpage, Convert CSV to PDF file online Users can save annotations to
rotate one page in pdf; rotate pdf page by page
CHEMCAD Version 5.6 
User’s Guide 
197 
4.  Close the Open dialog box by clicking the [Open] button. 
New PFD window will open.  This window has the commands for creating PFD’s, but no other 
commands.  In addition, the PFD Palette, will open and the program will go into “PFD mode”.  The 
PFD Palette is a modified graphics-editing palette and, as such, most of its functionality is described 
in the section “Drawing with the Palette”
5.  Create the PFD by: 
• 
Adding S
tream and U
nitOp databoxes, 
• 
Adding TP Boxes, 
• 
Adding Excel Ranges, 
• 
Adding Title Blocks, Symbols, and text, 
• 
Drawing primitives, moving objects, changing colors, etc., as desired. 
6.  Print and Save the PFD as desired. 
7.  To exit the PFD you must close the PFD Window.  You do this by clicking the [Close] button in the 
upper right hand corner of the window. 
OPENING AND EDITING SECONDARY PFD’S 
To open and edit a secondary PFD you: 
1.  Select the O
utput command on the Simulate Flowsheet menu bar.  The Output menu will appear. 
2.  Select the Open PFD option from this Output menu The Open dialog box will appear.  All existing 
PFD’s for this flowsheet will be listed. 
3.  Select the PFD you want to open by: 
• 
Double clicking on it 
• 
Clicking on  the [Openbutton. 
The PFD will open inside a PFD Window.  The File, Edit, ViewFormat, Window, and Help commands 
will be available for editing the PFD. 
ADDING A STREAM DATABOX TO THE PFD 
Clicking the Add Stream Box option on the Format menu will initiate a four-step process for placing a 
customized stream databox on the PFD.  These steps are: 
• 
Select the streams to be included in the databox, 
• 
Select the stream information to be included in the databox, 
• 
Select the databox display settings, 
• 
Move and size the databox as desired. 
VB.NET Word: VB.NET Code to Rotate Word Page Within .NET Imaging
Here, we can recommend you VB.NET PDF page rotating tutorial and multi any original quality during or after the Word page rotating; Save the rotated Word page
rotate pdf pages and save; rotate all pages in pdf
VB.NET Image: How to Process & Edit Image Using VB.NET Image
permanently? A 2: This VB.NET image editor control SDK allows developers process target image file and save edited image as new file.
rotate pdf pages by degrees; how to rotate pdf pages and save permanently
User’s Guide 
CHEMCAD Version 5.6 
198 
STEP 1: SELECT THE STREAMS TO BE INCLUDED IN THE DATABOX 
The Select Streams dialog box looks like this: 
Selecting the Print all Streams option will instruct the program to include data of all streams in the 
flowsheet in the stream databox. 
Selecting the Select Streams from flowsheet option will call the Select Streams dialog box.  Streams 
may then be selected by clicking on them with the cursor, and/or by typing their stream ID No.  Only the 
selected streams will be included in the stream databox 
If neither the Print all streams or the Select streams from flowsheet options are chosen, then streams 
may be selected by typing the desired stream ID Nos. directly into the fields provided under Enter the 
Stream ID Nos
After this dialog box is closed (by clicking [OK]), the Databox Property Options dialog box will appear. 
STEP 2: COMPLETE THE PFD PROPERTIES OPTIONS DIALOG BOX… 
The Databox Property Options dialog box looks like this: 
CHEMCAD Version 5.6 
User’s Guide 
199 
This dialog box is an extremely flexible way of specifying exactly what information you want included in 
the stream databox.  Notice that there are two pages to this dialog box. 
All options on this dialog box are toggle switches except the maximum number of streams in a row, 
Composition Option and the Include all components/Select components options (see below) in the 
lower middle part of the dialog box.  A checkmark in the box next to the item label indicates that the 
property will be included in the stream databox.  Those properties without a checkmark will not be 
included.  
Maximum number of streams in a row – This value specifies how many streams or columns across 
the stream databox will be.  If more streams are selected than this value, then CHEMCAD will "stack" the 
databox.  Twelve is the default. 
Composition Option – For a given stream databox the material balance may be presented in only one 
set of composition units (mole, mass, mole fractions, etc.).  You may have as many stream databoxes as 
you like and they may include the same streams, but each individual databox will use only one set of 
units.  To select which is to be used for this databox open the options list by clicking the small triangle to 
the right of the current selection.  A list of available options will open.  You can make your selection by 
clicking on it or by moving the highlight with the arrow keys and pressing the [Enter] key when the 
desired option is highlighted. 
Include all components/Select components – Choose from one of these options by clicking the small 
circle next to the label.  If you choose the Include all components  option, then all components in the 
component list for this flowsheet will be included in this stream databox where the heat and material 
balance is given.  If you choose Select components  then when you close the Databox Properties 
Options dialog box, the Select PFD components dialog box will appear to enable you to make your 
component selections.  In the default all of the components are included.  
When all selections have been made, click [OK] and the DataBox Settings dialog box will appear. 
User’s Guide 
CHEMCAD Version 5.6 
200 
STEP 3: COMPLETE THE DATABOX SETTINGS DIALOG BOX 
The Data Box Settings dialog box looks like this: 
When all selections have been made, click the [OK] button to close the dialog box.  The specified stream 
databox will appear on the PFD in the upper left-hand corner.  You will now need to move it to the 
desired location and stretch it to the desired size. 
STEP 4: MOVE AND STRETCH THE DATABOX 
The stream databox is a Windows object and therefore it can be moved and stretched like any other 
Windows object.  Therefore, 
To move the databox move the cursor over the databox and press the left button on the mouse.  While 
holding the left button down, slide the mouse around.  The databox will move with the mouse.  In this 
fashion, move the databox to its desired location. 
To stretch the databox move the cursor over the databox and press the left button on the mouse once.  
This is called selecting the object (databox) and when you do it four black squares will appear, one at 
each corner of the object (databox).  To resize or stretch the databox, move your cursor so that the tip of 
the arrow (cursor) is directly over one of these black squares.  Then, while holding down the left button, 
slide the mouse around.  The databox will change size and aspect ratio as you do this.  In this fashion 
enlarge or shrink the databox to the size you want. 
ADDING A UNITOP DATABOX TO A PFD 
Clicking the UnitOp Box option on the Format menu will initiate a three-step process for placing a 
customized UnitOp databox on the PFD.  These steps are: 
• 
Select the UnitOps for which you want to generate a databox.  An individual databox will be 
generated for each UnitOp selected. 
• 
Select the databox display settings. 
• 
Move and size the databox as desired. 
CHEMCAD Version 5.6 
User’s Guide 
201 
STEP 1: SELECT THE UNITOPS FOR DATABOX GENERATION 
The Select Unit Operations dialog box looks like this: 
Select units from flowsheet - Selecting the Select units from flowsheet option will call the Select 
UnitOps dialog box.  UnitOps may then be selected by clicking on them with the cursor, and/or by 
typing their ID No.  Only the selected UnitOps will be included in the UnitOps databox. 
If the Select Units from flowsheet option is not chosen, then streams may be selected by typing the 
desired UnitOp ID Nos. directly into the fields provided under Enter the Unit ID Nos. 
When all of the Wordpad windows have been closed, the program will proceed by opening the Data Box 
Settings dialog box. 
Click [OK] when the desired UnitOps have been identified.  The Data Box Settings dialog box will then 
appear. 
STEP 2: COMPLETE THE DATABOX SETTINGS DIALOG BOX 
The Data Box Settings dialog box looks like this: 
User’s Guide 
CHEMCAD Version 5.6 
202 
Font style – Choose from Regular, Bold, Italic or Italic Bold. 
Size – Specify the font size.  Default is 5. 
Section divider – Controls placing of horizontal and vertical lines as dividers in the databox. 
When all selections have been made, click the [OK] button to close the dialog box.  The specified 
UnitOp databox(s) will appear on the PFD in the upper left-hand corner.  You will now need to move it 
(them) to the desired location(s) and stretch it to the desired size(s).  Please note that if more than one 
databox was generated, initially they will be laid on top of each other.  Separate them by dragging the 
“top” one off the others. 
STEP 3: MOVE AND STRETCH THE DATABOX 
The UnitOps databox is a Windows object and therefore it can be  moved and stretched like any other 
Windows object.  Therefore, 
To move the databox move the cursor over the databox and press the left button on the mouse.  While 
holding the left button down, slide the mouse around.  The databox will move with the mouse.  In this 
fashion, move the databox to its desired location. 
To stretch the databox move the cursor over the databox and press the left button on the mouse once.  
This is called selecting the object (databox) and when you do it four black squares will appear one at 
each corner of the object (databox).  To resize or stretch the databox, move your cursor so that the tip of 
the arrow (cursor) is directly over one of these black squares.  Then, while holding down the left button, 
slide the mouse around.  The databox will change size and aspect ratio as you do this.  In this fashion 
enlarge or shrink the databox to the size you want. 
ADDING A TP BOX TO A PFD 
Clicking the Add TP Box option on the Format menu will initiate the process for placing customized 
temperature, pressure, and/or flowrate boxes on the flowsheet for selected stream(s).  The steps to add 
a TP box are: 
 Decide if you want the TP boxes generated for all streams or selected streams on the flowsheet. 
 Select the T, P, and/or F options (and their formats) which you want displayed on the PFD.   
 Select streams for TP boxes (unless generate boxes for all streams was chosen). 
 Move the TPF boxes as desired. 
SELECT OPTIONS TO DISPLAYED 
The TP Box Setting dialog box is shown below 
Documents you may be interested
Documents you may be interested