display pdf from byte array c# : How to rotate a single page in a pdf document control SDK platform web page wpf html web browser CCSSandCCBmanual5621-part1395

CHEMCAD Version 5.6 
User’s Guide 
203 
• 
Generate boxes for all streams (default) 
• 
Select streams from flowsheet 
If you select generate boxes for all streams then the TPF boxes will appear on all streams and step two 
below will be skipped. 
If you click on the second option, then the current dialog box will close and a Select Stream dialog box 
will appear, you can select only those streams on which you want the TPF boxes to appear.  
Display 
Choose from temperature,  pressure, mole  flowrate, or  mass flowrate.   The  selected  option  will  be 
displayed in the TP box on the flowsheet. 
Number Format 
Select which format is to be used in the TPF Boxes.  Options are Fixed Point, Scientific Notation, or 
Floating Point. 
Digits 
Specify the number of decimal places to be used in the display of each number. 
Font Style 
Choose fro Regular, Bold, Italic, or Italic Bold. 
Font Size 
Specify font size.  The default is 6 points. 
Display Units 
This allows the user to toggle on and off the engineering units in which each value is displayed. 
Stream ID’s 
Includes the stream ID in the TPF box. 
Select Streams from Flowsheet 
How to rotate a single page in a pdf document - rotate PDF page permanently in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Empower Users to Change the Rotation Angle of PDF File Page Using C#
how to rotate all pages in pdf at once; pdf rotate just one page
How to rotate a single page in a pdf document - VB.NET PDF Page Rotate Library: rotate PDF page permanently in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
PDF Document Page Rotation in Visual Basic .NET Class Application
how to rotate one page in pdf document; rotate pages in pdf and save
User’s Guide 
CHEMCAD Version 5.6 
204 
If the options Select Streams was chosen (above), when the user presses OK a select streams dialog 
will appear. Left click on the stream lines or type the desired stream numbers and press OK. 
Move the TP boxes as desired.  After the TP box(es) are placed on the flowsheet, they may be dragged 
and moved as desired. 
ADDING AN EXCEL RANGE 
CHEMCAD conveniently allows the user to display simulation data on the PFD in any format by clicking 
the Add Excel Range option on the Format menu.  This will initiate the process for pasting an Excel 
data sheet into the PFD.  
SELECT SETTINGS TO DISPLAYED 
The Excel Data Box Settings dialog box is shown below 
MS Excel Workbook Path 
Click on the Browse button to locate the path of the Excel file that has the data you wish to paste into the 
PFD.  Once you locate the file, the user should double click on it to display it in the Name field, then 
he/she should click on the open button to tell CHEMCAD to accept  the choice. 
VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
Able to remove a single page from adobe PDF document in VB.NET. This is a VB .NET example for how to delete a single page from a PDF document.
pdf rotate single page reader; pdf rotate pages and save
C# PDF Page Delete Library: remove PDF pages in C#.net, ASP.NET
Able to remove a single page from PDF document. Ability to remove a range of pages from PDF file. How to delete a single page from a PDF document.
rotate pdf pages individually; rotate pdf page
CHEMCAD Version 5.6 
User’s Guide 
205 
Excel Worksheet Name 
These fields allow the user to input the name of the worksheet that has the data he/she wish to display 
on PFD. By default Excel names worksheet as Sheet1, Sheet2, Sheet3, etc; but the user should make 
sure he/she inputs the corresponding worksheet name into this field. 
Cell Range 
These fields allow the user to tell CHEMCAD which range of cells are to be displayed on the PFD. 
Format 
These options allow the user to choose Font Style, Font Size and Minimum column width of the range to 
be displayed on the PFD. 
RUNNING A DYNAMIC SIMULATION 
The CHEMCAD Suite contains a library of the following dynamic unit operations: 
Batch reactor 
Dynamic Column (SCDS, TPLS, TOWR) 
Tank 
Time switch 
Dynamic vessel 
Time delay 
Control valve 
PID controller 
Ramp controller 
Any CC-STEADY STATE UnitOp can
be run in the dynamic mode.  Doing this may or may not make 
sense depending on how you set up the problem.  Implicit in using a steady-state UnitOp in a dynamic 
flowsheet is the assumption that the dynamics of that UnitOp are very fast. 
THE STEPS FOR SETTING UP A DYNAMIC FLOWSHEET… 
For the description given below, no attempt is made to duplicate material covered I on this manual.  
Instead, reference is made to other sections for more detailed descriptions whenever possible. 
Note: In order to run in the dynamics mode in CHEMCAD, you must own a 
license for a dynamic unit operation (CC-ReACS or CC-DCOLUMN) 
This is a brief introduction. See the Dynamics Manual for more detail. 
Notes: 1. For a description of the dynamic UnitOps, refer to the on-line manual. 
2.  Although the batch distillation module performs a dynamic calculation, 
it is currently set to run in the steady-state mode only. 
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
C#.NET PDF file & pages edit, C#.NET PDF pages extract, copy, paste, C#.NET rotate PDF pages, C# Users can view PDF document in single page or continue pages.
how to change page orientation in pdf document; how to save a pdf after rotating pages
How to C#: Basic SDK Concept of XDoc.PDF for .NET
insert, delete, re-order, copy, paste, cut, rotate, and save from file or query data and save the PDF document. The PDFPage class presents a single page in a
rotate pdf page and save; how to rotate all pages in pdf in preview
User’s Guide 
CHEMCAD Version 5.6 
206 
The steps for setting up a dynamic flowsheet are: 
1.  Start a new job 
2.  Select engineering units 
3.  Draw the flowsheet 
4.  Make sure the “dynamic mode” has been turned on 
5.  Select components 
6.  Select thermodynamics options 
7.  Specify feed streams and initial stream conditions 
8.  Specify UnitOps 
9.  Specify runtimes, time steps, and/or stop criteria 
10.  Run the simulation 
11.  Review the results with RESULTS and PLOT 
12.  Re-run the simulation or extend the run from the current simulation time 
13.  Generate reports 
These steps are described below. 
STARTING A NEW JOB 
Refer to sections: 
How to Start a New Job 
CHEMCAD Tutorial for WindowsStarting a New Job  
CC-BATCH Tutorial: Starting a New Job  
SELECTING ENGINEERING UNITS 
Refer to sections: 
How to Select Flowsheet Engineering Units 
CHEMCAD Tutorial for Windows: Selecting Engineering Units 
CC-BATCH Tutorial: Selecting Engineering Units 
DRAW THE FLOWSHEET 
Dynamics flowsheets are drawn exactly the same way as steady-state flowsheets are drawn.  Please 
note however, that not all dynamic UnitOps have to have inlets and outlets.  They can accumulate. 
For instructions on how to draw flowsheets in CHEMCAD, please refer to sections: 
How to Draw a Flowsheet 
Graphics in CHEMCAD – An Overview 
C# PDF Convert to Tiff SDK: Convert PDF to tiff images in C#.net
TIFF conversion control, C# developers can render and convert PDF document to TIFF image file with no loss in original file quality. Both single page and multi
pdf rotate page; pdf rotate single page
VB.NET PDF: Basic SDK Concept of XDoc.PDF
insert, delete, re-order, copy, paste, cut, rotate, and save from file or query data and save the PDF document. The PDFPage class presents a single page in a
rotate pages in pdf expert; pdf save rotated pages
CHEMCAD Version 5.6 
User’s Guide 
207 
How to Add UnitOps to the Flowsheet 
Drawing Streams 
How to Move, Modify, Delete, or Duplicate Objects 
CHEMCAD Tutorial for Windows: Drawing the Flowsheet 
CC-BATCH Tutorial: Drawing the Flowsheet 
MAKE SURE THE DYNAMICS MODE IS TURNED ON 
This  is done  on  the Convergence  dialog  box  under  the R
un command on the main menu bar.  
Sometimes the program turns it on automatically based on the presence of certain dynamic UnitOps. 
Procedure: 
1.  Click the R
un command on the main menu bar.  The following menu will appear: 
2.  Click the Convergence option at the top of the menu.  The Convergence Parameters dialog box 
will appear: 
3.  In the lower right-hand corner of this dialog box is a combo box labeled Steady State/Dynamics.  
Open this box by clicking on it.  The options Steady State and Dynamics will appear. 
4.  Click on the Dynamics option.  The combo box will close and the word Dynamics will show. 
5.  Click the [OK] button to close the dialog box and save the selection. 
VB.NET PDF File & Page Process Library SDK for vb.net, ASP.NET
With VB.NET PDF SDK, PDF document page can be rotated to 90, 180, and 270 in clockwise. Both a single page and whole file pages can be rotated and saved as
pdf rotate all pages; how to rotate a page in pdf and save it
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
Page: Rotate a PDF Page. PDF Read. Text: Extract Text from PDF. Text: Search Text in PDF. Users can view PDF document in single page or continue pages.
rotate all pages in pdf and save; rotate pdf page few degrees
User’s Guide 
CHEMCAD Version 5.6 
208 
SELECT COMPONENTS 
Refer to sections: 
How to Select Components for the Components List 
CHEMCAD Tutorial for WindowsSelecting Components 
CC-BATCH Tutorial: Selecting Components 
SELECT THERMODYNAMIC OPTIONS 
Refer to sections: 
How to Select K-Value Options 
How to Select Enthalpy Options 
CHEMCAD Tutorial for Windows: Selecting Thermodynamic Options 
CC-BATCH Tutorial: Selecting Thermodynamic Options 
SPECIFY FEED STREAMS AND STREAM INITIAL CONDITIONS 
In a dynamic simulation, as in a steady state simulation, all feed streams must be defined.  That means 
that the composition, flowrate, and thermodynamic properties (two of T, P, and VF) must be given.  
Sometimes the flowrate is reset by a control valve, during the simulation, but some flowrate must be 
given.  As always, the program must know the composition and enthalpy at all times. 
In addition to the feed streams, it is sometimes important to know the contents and conditions of the 
intermediate streams at time zero.  You must also give these conditions when necessary. 
Input for all streams is provided in the same way.  For a description of this input procedure, refer to 
sections: 
How to Define the Feed Streams 
CHEMCAD Tutorial for Windows: Defining the Feed Stream 
CC-BATCH TutorialDefining the Feed Streams 
SPECIFYING UNITOPS 
Please refer to sections: 
Using Dialog Boxes 
How to Specify UnitOps 
CHEMCAD Tutorial for Windows:  Inputting Equipment Parameters 
CC-BATCH TutorialInputting Equipment Parameters 
SPECIFYING RUNTIMES, TIME STEPS, AND/OR STOP CRITERIA 
This function is performed using either the Dynamic Menu (on the Run Menu or the Set Run Time 
power button on the Toolbar. 
This command is used to set the simulated time of the dynamics run and to specify the time step size 
(how often the flowsheet equations are integrated).  These items must be specified for the calculation to 
proceed.  Clicking this option will cause the Set Simulation Run Time dialog box to be displayed.  For 
CHEMCAD Version 5.6 
User’s Guide 
209 
each operating step, this dialog box will have fields for the duration of the operating step, the number of 
time steps per operating step, and the stop criteria. 
Please take note of the following: 
1.  More than one operating step can be specified.  If a run is made from time zero (i.e., the initial 
state), all specified operating steps will be run.  If the simulation is being run from the current state, 
then only those operating steps beyond the current time will be run. 
Operating steps can be added at any time, so this feature provides a facility for extending the 
dynamic simulation indefinitely. 
2.  The time step size is specified in the Step size field 
3.  The criteria for terminating one operating step and moving to the next one can be set by specifying 
elapsed time or the occurrence of some event in the flowsheet.  The overall simulation time is then 
equal to the sum of the total simulation times for each step. 
RUNNING THE DYNAMIC SIMULATION 
Dynamic simulations are run from the Dynamics menu.  The Dynamics menu is located on the RUN 
menu which is accessed by clicking the R
un command on the Top Level Menu Bar of the Simulate 
Flowsheet window.  Therefore, to get to the Dynamics menu, do the following: 
1.  Select the R
un command from the menu bar.  The Run menu will appear. 
2.  Click the Dynamics option on Run menu.  The Dynamics menu will appear. 
These options are explained below. 
EXIT: 
The Exit command is used to close the Dynamics menu. 
SET RUN TIME: 
Please refer to the section “Specifying Runtimes, time Steps, and/or Stop Criteria” 
RUN FROM INITIAL STATE: 
User’s Guide 
CHEMCAD Version 5.6 
210 
Selecting  this option will cause the program to  return  to the initial  conditions and  rerun the entire 
simulation.  All results from previous simulations will be discarded. 
RUN FROM CURRENT STATE: 
Selecting this option will continue the simulation from the current state, i.e., from the last calculated 
result.  In order to use this option, time beyond the current state must be scheduled on the Set runtime 
option above. 
RESTORE TO INITIAL STATE: 
This option will restore the initial conditions specified.  All previous calculations will be discarded.  It is 
necessary to exercise this option in order to change certain flowsheet variables.  Once a simulation has 
taken place, CHEMCAD will not allow you to change any variables which might produce thermodynamic 
inconsistencies if the simulation is continued.  Therefore, the restore command is necessary to enable 
changes to these variables. 
RECORD STREAMS: 
Unless specifically requested by the user, the dynamic history of streams is not saved by the program.  
Unsaved streams cannot be reported or plotted once the simulation is finished.  The Record Stream 
dialog box is used to specify which streams are to be recorded or saved during the simulation.  In 
addition, it is used to  specify which streams are to be plotted on the computer screen during
the 
simulation or "run time".  The procedure for these specifications is as follows: 
1.  To specify that a stream is to be recorded, but not plotted during runtime, simply enter the stream 10 
number in one of the labeled fields provided for this purpose.  Then click the [OK] button. 
2.  To specify that a stream is to be plotted during runtime do the following: 
• 
Enter the stream (1) number in one of the fields provided; 
• 
Click on the Run time plot box next to the above field; 
• 
Click on the [OK] button.  The Dynamic Streams Plot Options dialog box will appear. 
• 
Identify which variable(s) is to be plotted. 
• 
Click [OK].  If more than one stream is to be plotted during runtime, then another Dynamic 
Stream Plot Options dialog box will appear.  One will appear for each stream requested.  
When the stream variables for all the requested streams have been selected, the program 
returns to the Dynamic Menu
RECORD UNIT OPERATIONS: 
Unless otherwise specified, CHEMCAD will only record the histories of batch reactors and dynamic 
columns.  For all other UnitOp and streams, only the initial and final variable values are recorded.  If you 
desire to view, plot, or report the historical results of other UnitOps, then you must instruct the program 
to do so using the Record Unit Operations dialog box.  In addition, this dialog box is used to specify 
which UnitOps are to be plotted during runtime.  This procedure is similar to that described above for 
streams. 
RECORD PROCESS: 
This option will allow you to specify that the entire flowsheet be saved at intervals you specify on this 
screen. 
CHEMCAD Version 5.6 
User’s Guide 
211 
SAVE AS INITIAL STATE: 
This option will allow you to specify that the current flowsheet conditions be saved as the initial state 
(time=zero) conditions.  If you select this option, the original initial state conditions will be lost.  
HELP: 
This option will open the help facility for the dynamic menu. 
Review the answers with the results and Plot commands 
USING THE RESULTS COMMAND: 
General use of the Results command is described elsewhere in sections listed below.  However, notice 
should be taken of the following points when viewing dynamic results. 
1.  Clicking on the Results command on the menu bar will cause the Results menu to open.  This 
menu contains a set of options for reviewing program output. 
2.  The answers for batch reactors can be reviewed using the Batch results and the Dynamic UnitOp 
History options. 
3.  Dynamic column results are reviewed using the Dynamic Column History option. 
4.  The answers for other dynamic unit operations are reviewed using the Dynamic UnitOp History 
command.   
5.  Stream histories are obtained using the Dynamic Stream History option. 
6.  The Unit Operations option can be used to produce a display of the input for a dynamic UnitOp.  
Certain calculated values, such as final temperature, final level, etc., will also be displayed. 
7.  The Streams option will display properties and composition of any stream at end of the simulation. 
8.  A UnitOp and stream histories can be obtained for only recorded
UnitOps and streams. 
For explanations of how to use the Results command, please refer to the following sections: 
User’s Guide 
CHEMCAD Version 5.6 
212 
How to Review Stream Properties 
How to Review Stream Compositions 
How to Set Flow Units for Results displays 
CHEMCAD Tutorial for Windows: Reviewing the Results Interactively 
CC-BATCH Tutorial: Reviewing the Results Interactively 
USING THE PLOT COMMAND: 
Stream histories and UnitOp histories are plotted using the Batch Reactor/DVSL History, Dynamic 
Column History, Dynamic Stream History, and UnitOp History options on the Plot menu.  With the 
exception of batch reactors and dynamic columns, you must indicate to the program that a given stream 
or UnitOp is to be recorded before the simulation is run, otherwise the data will not be available to plot. 
For an explanation of plotting dynamic streams and unit operations, see the section titled: 
HOW TO PLOT: PLOT MENU OPTIONS: 
Multiple variables can be simultaneously plotted, but it is up to you to keep the engineering units straight. 
Upon closing the selection dialog box (by clicking [OK]), the plot will be displayed in a Plot Window.  
Using the editing facilities of this window, the plot can be modified as desired. 
Multiple plot windows can be opened and tiled for simultaneous display if desired. 
To close a plot, click the close button of the Plot window
Unlike  steady-state  plots, tabulations  of the  numbers  used to  create  the plot are  not displayed  in 
WordPad.  To obtain these values, you must generate a history report using the OUTPUT/REPORT 
function, or you can send the plot values to EXCEL using the Graph\Data to EXCEL commands. 
See also: 
How to Plot 
How to Generate a Report 
CC-BATCH Tutorial – Plotting the Results 
RE-RUNNING AND EXTENDING THE RUN 
At the end of any dynamic simulation, CHEMCAD will know the following: 
1.  All of the numbers at time zero, i.e., the entire initial state. 
2.  All of the numbers at the ending time of the simulation, i.e., the entire final state. 
3.  The recorded numbers at each time in-between the initial and final states, i.e., selected portions of 
the intermediate states. 
Dynamic  runs  can  be  made  only  from states  or  times that  are  completely  known.   Therefore,  in 
CHEMCAD, dynamic runs can only be made from time zero or from the current state. 
RE-RUNNING FROM TIME ZERO: 