CHEMCAD Version 5.6 
User’s Guide 
33 
SEARCH FOR WORDS OR PHRASES 
1.  In Help, click the Search tab to find words or phrases in the Help topics. 
2.  Type the word or phrase that you wish to find in the first field. 
3.  The second field displays additional words to help you narrow your search. 
4.  The third field displays the list of topics that were found in the search. 
TO CUSTOMIZE THE SEARCH FOR WORDS OR PHRASES 
1.  In the Help dialog box, click  on Help Topics, then click the Search menu’s Options command. 
2.  Select the search options that you prefer to use. 
If an option is unavailable, use the Search menu’s Rebuild command. 
3.  Note: The text of each topic found contains the word(s) you looked for, even if the word(s) are not in 
the topic title. 
Tip: For Help on an item, click on the field containing that item and press the [F1] key. 
Tip: If you want to look for more than one word, separate them with spaces in the first 
text box. 
When you look for hyphenated words, be sure to type the hyphen. 
To set specific search criteria, click Options
Rotate pages in pdf and save - rotate PDF page permanently in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Empower Users to Change the Rotation Angle of PDF File Page Using C#
how to rotate one pdf page; rotate all pages in pdf
Rotate pages in pdf and save - VB.NET PDF Page Rotate Library: rotate PDF page permanently in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
PDF Document Page Rotation in Visual Basic .NET Class Application
how to reverse pages in pdf; how to rotate all pages in pdf in preview
User’s Guide 
CHEMCAD Version 5.6 
34 
CC-STEADY STATE TUTORIAL 
INTRODUCTION 
CHEMCAD is a very easy program to learn and the best way to master it is by using it.  This tutorial 
provides basic input skills for operating CC-STEADY STATE.  Since CC-STEADY STATE is a module of 
CHEMCAD, the names will be used interchangeably in this tutorial.  Here we provide a step-by-step 
description of how to solve the condensate stabilizer problem given below.  The input procedure is 
simple and straightforward.  It is designed to  be intuitive for a chemical engineer  familiar  with the 
Windows environment.  However, for the sake of clarity and for those new to Windows, a review of some 
of the basic rules for using CHEMCAD is given. 
BASIC RULES – GENERAL 
The following ten basic steps are used to run a flowsheet simulation in CHEMCAD. 
• 
Starting a new job 
• 
Selecting engineering units 
• 
Creating a flowsheet 
• 
Selecting components 
• 
Selecting thermodynamics options 
• 
Defining the feed streams 
• 
Input equipment parameters 
• 
Running the simulation 
• 
Reviewing the results 
• 
Generating hardcopy output 
The steps do not have to be performed in this order, nor do all of them have to be done for each 
flowsheet.  All should be considered for each problem. 
There are a series of Help facilities available throughout the program.  The bottom line of the screen 
provides a  one-sentence  description of the current highlighted item.   The Help  command  provides 
access to the On-line Manual,  which contains comprehensive technical information.  The [F1] key 
provides context sensitive help (place the cursor in a specific field and press the [F1] key).  The Coach 
facility will provide instructions on how to perform selected tasks.  Use of these help facilities will ease 
your way through the program. 
CHEMCAD is object oriented.  Therefore, most input and editing can be done by double clicking or right 
clicking the object of the operation, as well as by using the menu commands. 
VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
doc.Save(outPutFilePath). How to VB.NET: Delete Consecutive Pages from PDF. This is a VB .NET example for how to delete a range of pages from a PDF document.
rotate one page in pdf; how to rotate one page in a pdf file
C# PDF Page Insert Library: insert pages into PDF file in C#.net
how to merge PDF document files by C# code, how to rotate PDF document page doc2.Save(outPutFilePath Add and Insert Multiple PDF Pages to PDF Document Using
pdf rotate one page; how to rotate pdf pages and save permanently
CHEMCAD Version 5.6 
User’s Guide 
35 
All stream and unit operations specifications (input) are accomplished using dialog boxes.  These dialog 
boxes are context  specific and employ some combination of character  fields, combo boxes, choice 
boxes and check boxes. 
HOW TO USE THE MOUSE 
The mouse is a very easy to use way to get the computer to do what you want.  CHEMCAD, like many 
Windows program, requires the use of a mouse, trackball, or similar pointing device with both a primary 
and secondary button (i.e. a standard Microsoft 2-button mouse).  The basic Mouse techniques are 
summarized below: 
Click 
To  press  and release the primary  mouse button (normally  the  left 
button). 
Right-click 
To press and release the secondary mouse button (normally the right 
button). 
Double-click 
To press the primary button twice in rapid succession. 
Drag 
To press and hold down the primary mouse button while moving the 
mouse. 
Point 
To move the mouse arrow until it touches the item of choice. 
Right-click hold 
Point to a specific area, then click and hold the secondary mouse 
button. 
USING THE KEYBOARD 
• 
The [TAB] key is used to move to the next field on a data entry dialog box. 
• 
The [PgUp] and [PgDn] keys may be used to “page” or scroll through lists. 
• 
Holding down the [SHIFT + TAB] will cause the program to move back or up one field. 
• 
The [F1] key is used to call context specific help. 
• 
The [F6] key is used for engineering units conversion. 
• 
The [F7] key calls a simple calculator. 
THE TOOL BAR BUTTONS 
The “Standard” way of executing commands in CHEMCAD is to click a command on the Menu Bar and 
follow that command down through the subsequent menus until the desired function is reached.  Thus, to 
select components from  the databank,  one would first click the command ThermoPhysical
on  the 
C# PDF Page Delete Library: remove PDF pages in C#.net, ASP.NET
doc.DeletePage(2); // Save the file. doc.Save(outPutFilePath); Demo Code: How to Delete Consecutive Pages from PDF in C#.NET. How
rotate individual pdf pages reader; rotate pdf page permanently
C# PDF Page Extract Library: copy, paste, cut PDF pages in C#.net
Able to extract PDF pages and save changes to original PDF file in C#.NET. C#.NET Sample Code: Extract PDF Pages and Save into a New PDF File in C#.NET.
reverse pdf page order online; rotate individual pages in pdf
User’s Guide 
CHEMCAD Version 5.6 
36 
Simulation Menu Bar; click the option Component L
ist from the ThermoPhysical Menu and finally 
select components from the Component Selection dialog box.   
There  is  a  shorter way  of  reaching  this and  other frequently  used  functions.   This  is to  use the 
CHEMCAD Power buttons, which are located on the tool bar.  This tool bar is toggled on and off using 
the View/Toolbar command. 
A DESCRIPTION OF THE PROBLEM 
The problem to be solved in this tutorial is illustrated in figure below.  It is a condensate stabilizer plant.  
Gas enters the system with the feed conditions shown.  It is our job to take this existing unit and 
determine new operating conditions and any necessary modifications.  The design requirements are as 
follows: 
1.  The cricondentherm dewpoint of the product gas must be 20° F or less.  A cricondentherm is the 
highest temperature for two phase coexistence of a mixture. 
2.  The stabilized condensate (Stream 9) must have maximum propane content of 1%. 
2
3
5
3
1
1
2
4
5
9
4
7
6
8
Condenser Stabilizer
HX-1
P drop1 = 5psi
Pdrop 2 = 5 psi
Vap.Frac (1) = 1.0
HX-2
P drop = 5 psi
T out = -5 F
Valve
P out = 125 psia
Stabilizer
12 stages
Fedd stage = 1
Bottom draw = 30 lbmoles/hr
Feed:
T = 75 F
P = 200 psi
N2 = 100.19 lbmoles/hr
C1 = 4505.48
C2 = 514.00
C3 = 214
iC4 = 19.20
nC4 = 18.18
iC5 = 26.40
nC5 =14.00
nC6 = 14.00
1 % propane
Cricondentherm 
dewpoint = 20 F
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
outPutFilePath As String = Program.RootPath + "\\" Output.pdf" Dim doc1 doc2.InsertPages(pages, pageIndex) ' Output the new document doc2.Save(outPutFilePath
rotate pdf page few degrees; how to rotate page in pdf and save
How to C#: Rotate Image according to Specified angle
pages edit, C#.NET PDF pages extract, copy, paste, C#.NET rotate PDF pages, C#.NET VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Excel, VB Steps to Rotate image.
pdf rotate pages and save; pdf rotate single page reader
CHEMCAD Version 5.6 
User’s Guide 
37 
GETTING STARTED 
The first time you run CHEMCAD, the Top Level Window will appear on your screen.  Please maximize 
this window (that is, zoom it to fill in the screen) by clicking the Maximize button in the upper right hand 
corner of the CHEMCAD window.  This will cause CHEMCAD to fill your screen and your display should 
look something like this: 
The top line is called the Title Bar.  It contains the CHEMCAD logo and name on the left side, and the 
WINDOWS minimizetile, and close buttons on the right side. 
The next line is called the Menu Bar.  This bar contains the top-level commands for CHEMCAD.  They 
are: 
File 
This command is used to define output formats, open jobs, 
print, and obtain general information about CHEMCAD. 
License 
This command is used to configure license, update dongles, 
and authorize special licenses. 
View 
This command enables the user to toggle the Tool bar and 
Status bar on and off. 
Help 
This function allows the user to call the on-line Help facility. 
The third line (or bar) is called the Tool Bar.  It contains the symbols to directly invoke short cuts to 
various file functions that would otherwise be accessed through the menus. 
The remainder of the window is inactive at this level. 
Tool Bar 
Menu Bar 
Title Bar 
Close Button 
Tile 
Minimize Button 
C# Create PDF from Tiff Library to convert tif images to PDF in C#
Similarly, Tiff image with single page or multiple pages is supported. Description: Convert to PDF and save it on the disk. Parameters:
reverse page order pdf online; how to reverse page order in pdf
C# Create PDF from Word Library to convert docx, doc to PDF in C#.
Able to get word count in PDF pages. Change Word hyperlink to PDF hyperlink and bookmark. Description: Convert to PDF/TIFF and save it on the disk.
rotate all pages in pdf file; rotate pdf pages in reader
User’s Guide 
CHEMCAD Version 5.6 
38 
The current window displays only the top-level of CHEMCAD.  CHEMCAD also has other windows for 
setting up and running a simulation, generating PFD’s, creating and editing plots, etc.  In the course of 
this tutorial, you will be introduced to these windows and their use. 
STARTING A NEW JOB – THE SIMULATION WINDOW 
Let’s start by opening a new job and giving it a job name.  The File command is used for this.  To open 
the File menu, click on the word File on the menu bar. 
Now choose the N
ew Job option by clicking on it. 
The following dialog box will open: 
This dialog box is prompting you to enter a name and folder for the new job.  Let’s use the name 
TUTOR1.  Please enter this name in the field labeled File N
ame.  Then close the dialog box by clicking 
the [S
ave] button.   
You will be taken into the main working window of CHEMCAD.  The major features of this window are 
described below:  
CHEMCAD Version 5.6 
User’s Guide 
39 
The top line, called the Title Bar, now contains the CHEMCAD logo and the current job name, as well as 
the minimizetitle, and close buttons which are always present on the left side. 
The Menu Bar follows the Title Bar and consists of fifteen commands.  These commands are: 
F
ile 
For file management and print control.   
E
dit 
For  modifying  various  aspects  of  the  flowsheet  and  its 
presentation.  Edit functions include Redraw, Undo, Redo, 
Cut,  Copy,  Paste,  Delete,  Flip, and Rotate  90° among 
others. 
V
iew 
For controlling various display and drawing options. 
Form
at 
For  selecting  engineering  units, setting  graphics  options, 
and importing bit maps. 
Mode 
To switch back and forth between the Simulation mode, the 
Flowsheet mode, and the Main PFD mode. 
ThermoPhysical
For selecting components, K-Value method(s), and enthalpy 
method(s) for the current job, as well as viewing and editing 
the CHEMCAD databanks; setting up distillation curves and 
defining solids. 
Title Bar 
Active Area 
Menu Bar 
Tool Bar 
Palette
User’s Guide 
CHEMCAD Version 5.6 
40 
S
pecifications 
For  entering,  editing,  and  manipulating  stream  and  unit 
operations data.  This may also be done by double clicking 
the stream or UnitOp directly on the flowsheet. 
R
un 
For  running  the  simulations,  as  well  as  for  defining 
numerical controls and parameters. 
Resu
lts 
For reviewing calculated results. 
P
lot 
For displaying calculated results graphically. 
O
utput 
For preparing reports and Process Flow Diagrams (PFD’s). 
Siz
ing 
For  performing  sizing  and  rating  calculations  for  various 
types of equipment. 
T
ools 
For performing various activities associated with simulation.  
These  include  data  regression,  CO
2
,solids  and  hydrates 
prediction, TOD/COD calculations and others. 
W
indow 
For arranging windows and icons display. 
H
elp 
For invoking the CHEMCAD help system or Coach. 
The Menu Bar is followed by the Tool Bar.  The toolbar contains “power buttons” or short cuts to 
specific frequently used functions.  These toolbar functions are explained in an earlier section of this 
guide. 
Below the Tool Bar is the Active Area Notice that this area is accompanied by elevator bars for 
scrolling the active area display up and down, and left and right.  Because we have not yet drawn 
our flowsheet, the Active Area is now blank except for the Main Palette
The Main Palette provides access to the graphics functions and symbols that are necessary for the 
creation of the flowsheet. 
SELECTING ENGINEERING UNITS 
To select engineering units for this flowsheet, select the Form
at command by clicking it with the mouse.  
The following menu will appear: 
CHEMCAD Version 5.6 
User’s Guide 
41 
Now select the Engineering Units option by clicking on it with the mouse.  The following dialog box will 
appear: 
The ENGLISH units option is the default and is currently highlighted.  You may change the engineering 
units system by clicking any one of the four buttons English, Alt SI, SI, or Metric, or you can change any 
unit individually by clicking on the individual item and then selecting from the list presented.  For this 
tutorial we will use English engineering units, therefore just exit the dialog box by clicking the Cancel 
button. 
User’s Guide 
CHEMCAD Version 5.6 
42 
DRAWING THE FLOWSHEET 
To draw the flowsheet you will be working with the flowsheet palette, which looks like this:  