display pdf from byte array c# : Rotate pages in pdf permanently application SDK utility azure wpf web page visual studio CCSSandCCBmanual565-part1399

CHEMCAD Version 5.6 
User’s Guide 
43 
Please note the following about the flowsheet palette: 
• 
The top left arrow button activates an alphabetical list of unit ops in a separate dialog. 
• 
The second button (rotate) enables the user to rotate objects on the flowsheet. 
• 
The next five buttons (reading horizontally)  enable  the user  to draw the indicated  graphic 
symbol on the flowsheet. 
• 
The ab button is used to put a text box on the flowsheet. 
• 
The 
button is for drawing process streams (streams must connect unit operations). 
• 
The remaining buttons each represent one of the unit operations in the CHEMCAD library, or a 
user added module. 
• 
Pointing to a button with the cursor will cause a small descriptive label to appear which will 
indicate what each button represents. 
• 
Pointing to a button and clicking with the left button of the mouse will select the object and allow 
you to place it on the flowsheet. 
• 
Pointing to a button and clicking with the right
button of the mouse will cause a sub-palette of 
secondary icons to appear.  Right clicking again (on the same
master palette box) will cause 
the sub-palette to disappear.  Selecting a UnitOp icon from the sub-palette and placing it on the 
flowsheet will cause the sub-palette to disappear. 
• 
Multiple sub-palettes may be displayed simultaneously. 
• 
In edit flowsheet mode, the palette may be switched on and off by changing the checkmark next 
to Main Palette on the View menu.  A graphics palette command button can also be used to 
hide/show the palette. 
• 
The size and shape of the main palette can be controlled using the Palette Settings command 
on the View menu. 
• 
On the icon display, inlets are indicated by small blue squares and outlets by small red squares. 
Now we set up the flowsheet topology.  Creating a flowsheet is the process of placing unit operations 
icons  on  the screen, connecting  them with  streams,  and then adding  various graphical  objects to 
enhance the drawing.  All of these things may be done using the palette. 
We will start by placing unit operations icons on the flowsheet.  By convention, CHEMCAD requires that 
every stream come from a unit operation and go to a unit operation.  Therefore, we must place a Feed 
icon on the flowsheet to serve as the “source” unit for the feed stream.  This is a good place to start by 
pointing to the Feed button on the palette: 
Rotate pages in pdf permanently - rotate PDF page permanently in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Empower Users to Change the Rotation Angle of PDF File Page Using C#
how to save a pdf after rotating pages; how to rotate one page in pdf document
Rotate pages in pdf permanently - VB.NET PDF Page Rotate Library: rotate PDF page permanently in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
PDF Document Page Rotation in Visual Basic .NET Class Application
pdf expert rotate page; pdf reverse page order online
User’s Guide 
CHEMCAD Version 5.6 
44 
Please follow the procedure given below: 
1.  Right click the feed icon box.  The Feed sub-palette will appear.  Now right click the feed icon box 
on the main palette again.  The sub-palette will disappear.  This is how you call and close UnitOp 
icon sub-palettes. 
2.  Now left click on the feed icon (on the main palette).  The palette will disappear and a small, square 
box will appear on the screen.  This is the cursor used to position and place UnitOp icons on the 
flowsheet. 
3.  Move the cursor to a position which is approximately in the left center of the screen.  Then left click 
the mouse.  The feed icon will appear on the flowsheet and the palette will reappear.  Notice that 
since we selected our feed icon from the main palette, the icon displayed is the same one displayed 
on the main palette.  To choose a different feed icon we would have had to select from the feed icon 
sub-palette. 
This completes the placement of the UnitOp Feed
For instruction purposes, let’s explore some of the options associated with the Feed icon.   
a.  To move the symbol: 
• 
Place the mouse arrow on the icon. 
• 
Hold down the left button on the mouse.  The four windows object boxes will appear. 
• 
With the left mouse button held down, drag the icon up about one-inch, then release the 
left button of the mouse.  The icon position has been changed. 
b.  It may be necessary to move the palette out of the way in order to have access to the icon.  You 
can do this by clicking and dragging on the red bar at the top of the palette. 
c.  To view the object editing options: place the mouse arrow on the icon (on the flowsheet, not on 
the palette) and press the right button on the mouse.   
Feed
VB.NET PDF Page Redact Library: redact whole PDF pages in vb.net
file & pages edit, C#.NET PDF pages extract, copy, paste, C#.NET rotate PDF pages, C#.NET Enable VB.NET Users to Redact PDF Pages to Protect PDF Document in
save pdf rotated pages; rotate single page in pdf reader
C# PDF Page Redact Library: redact whole PDF pages in C#.net, ASP.
Page: Rotate a PDF Page. PDF Read. Text: Extract Redaction is the process of permanently removing visible our redact function API to redact entire PDF pages.
how to rotate all pages in pdf at once; rotate pdf page and save
CHEMCAD Version 5.6 
User’s Guide 
45 
d.  To move or stretch an object: left click on the icon so that the four object boxes are displayed 
around the icon.  Then click and drag on one of these boxes.  The icon will grow or shrink 
according to the mouse movements. 
Now let’s place the two heat exchangers on the flowsheet.  Please follow the procedure given below: 
1.  Point to the heat exchanger tile and let the cursor stay there until the message label appears.  Using 
this label, make sure you are pointing to the heat exchanger box. 
2.  Right click the box.  The heat exchanger icon sub-palette should appear. 
3.  Now point to the two sided heat exchanger icon as indicated below: 
4.  Left click on this icon.  The palettes will disappear and the small, square cursor will reappear. 
5.  Locate the cursor about one inch directly to the right of the feed icon.  Then left click again.  The 
heat exchanger icon will be displayed on the flowsheet and the main palette (only) will reappear. 
6.  Now point to the heat exchanger tile again.  This time we want a single sided heat exchanger such 
as the one shown on the main palette.  Therefore, we do not need to call the sub-palette again. 
7.  Left click on this icon.  The palette will disappear and the small, square cursor will reappear. 
8.  Locate the cursor about one inch directly to the right of the first heat exchanger icon.  Then left click 
again.  The heat exchanger icon will be displayed on the flowsheet and the palette will reappear. 
Your flowsheet should now look similar to this: 
Two-sided heat 
exchanger 
VB.NET Image: How to Process & Edit Image Using VB.NET Image
VB.NET Image Rotator Add-on to Rotate Image, VB.NET Watermark Maker to VB.NET image editor control SDK, will the original image file be changed permanently?
save pdf after rotating pages; rotate pdf pages by degrees
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit Excel
to change view orientation by clicking rotate button. users can convert Excel to PDF document, export Users can save Excel annotations permanently by clicking
pdf reverse page order; rotate pages in pdf expert
User’s Guide 
CHEMCAD Version 5.6 
46 
For convenience, move the palette to one side by clicking and dragging on the red bar at the top of the 
palette.  Now follow the procedure outlined above to place the flash tank and the valve unit operations on 
the screen:  
For the condensate stabilizer itself, we want to use a distillation column module.  You might notice from 
the palette that there are multiple distillation modules available in CC-STEADY STATE.  An explanation 
of each of these options is given in the on-line Help manual.  You can access this manual at any time by 
clicking the Help command on the menu bar.  For now however, let’s accept that the module we want to 
use is the rigorous distillation model called Tower This UnitOp is found on your palette as shown below: 
VB.NET Image: How to Create a Customized VB.NET Web Viewer by
used document & image files (PDF, Word, TIFF btnRotate270: rotate image or document page in burnAnnotationToImages: permanently burn drawn annotation on page in
pdf rotate just one page; pdf reverse page order preview
How to C#: Cleanup Images
By setting the BinarizeThreshold property whose value range is 0 to 255, it will permanently modify the image to 1bpp grayscale image of the Detect Blank Pages.
rotate one page in pdf reader; how to permanently rotate pdf pages
CHEMCAD Version 5.6 
User’s Guide 
47 
Since we want to use a Tower icon that has a reboiler but no condenser, we must use the sub-palette to 
select the desired icon.  Therefore, right click on the Tower icon box.  The sub-palette will appear.  
Select the Tower icon indicated below by left clicking on it. 
Now add it to the flowsheet: 
Reboiled Tower w/o 
Condenser 
How to C#: Color and Lightness Effects
Geometry: Rotate. Image Bit Depth. Color and Contrast. Cleanup Images. NET comment annotate PDF, VB.NET delete PDF pages, VB.NET VB.NET How-to, VB.NET PDF, VB.NET
how to rotate a single page in a pdf document; rotate pages in pdf online
User’s Guide 
CHEMCAD Version 5.6 
48 
Finally, we must put three Product icons on the flowsheet, one for each product stream.  The Product 
icon is located slightly to the right and down from the center of the palette as shown: 
CHEMCAD Version 5.6 
User’s Guide 
49 
When you are finished, you screen should look similar to this: 
PUTTING STREAMS ON THE FLOWSHEET 
It’s now time to connect the UnitOps with streams.  To do this, click the S
treams icon box on the main 
palette. 
User’s Guide 
CHEMCAD Version 5.6 
50 
There are a few general rules to remember when we are drawing streams on the flowsheet: 
1.  Each stream goes from a source unit to a destination unit. 
2.  Each unit has inlet and outlet positions.  These are established when the symbol is created.  The 
program always snaps streams to these positions.  During the simulation, a process stream always 
flows from an outlet position on a source unit to an inlet position on a destination unit, but when 
drawing the flowsheet a stream may be drawn in any direction; that is; from an inlet position to an 
outlet position as well as from an outlet position to an inlet position. 
3.  When starting a stream, the cursor will be a small cross.  When the cursor gets near an inlet (blue 
squares) or outlet (red squares) position, it will convert to a black arrow.  When this occurs, you 
should left click the mouse to start the stream if that is the starting position you desire. 
4.  When completing the stream to a unit, the cursor will remain as a black arrow.  When the cursor is 
near an inlet or outlet position, a label will appear indicating the location and number of the position. 
5.  Once the desired position has been located (as indicated by the appearance of the label), you 
should left click the mouse to complete the stream. 
6.  While  drawing  a  stream,  the  palette  will disappear.   It will  reappear  only when  you  left  click 
somewhere on the flowsheet which is not a UnitOp inlet or outlet point.  You are not
required to click 
the stream (link) icon tile each time you begin a stream. 
7.  You can alternate between placing UnitOps on the screen and connecting them with streams as 
long as the above rules are followed. 
8.  The first time you change directions of a stream, CHEMCAD will let you do so without any problem.  
Every additional time you change directions, you must first press the left button on the mouse to 
identify the longitude or latitude through which you want the stream to pass.  Doing this will create 
an anchor point to fix the longitude or latitude on the screen.  
9.  You may cancel the stream drawing action by double clicking the left button during the stream 
drawing process. 
With these rules in mind, let us now connect the UnitOps with streams. 
Click the Streams icon box on the palette.  The palette will disappear and the crosshairs cursor will 
appear.  Move the cursor close to the tip of the feed arrow.  When the cursor switches to a black arrow, 
press the left button on the mouse.  Draw the stream over to the right with your mouse.  When the label 
for  left-most inlet  arrow on the first heat exchanger  appears, press  the left  button  on the  mouse.  
CHEMCAD will draw the stream directly to that point and will place a stream ID number on the flowsheet.  
CHEMCAD issues ID numbers sequentially, so this ID will be Number 1.  You may change it using the 
EDIT STREAM menu (invoked by right clicking the stream) if you would like to do so. 
Let’s draw the second stream.  Move the cursor to the right-most point of the first heat exchanger.  When 
you are close enough to the unit outlet point, the cursor will switch over to the black arrow again.  Press 
the left button on the mouse.  Draw the stream over to the inlet position on the second heat exchanger 
and, when the label appears, press the left button on the mouse again.  This should complete Stream 2. 
Next, let’s draw the stream from the second heat exchanger to the flash tank.  Locate the right most 
outlet point on the Heat Exchanger unit.  When the black arrow appears, click the left mouse button.   
CHEMCAD Version 5.6 
User’s Guide 
51 
Now, draw the stream over to the flash tank until the first inlet label appears.  Press the left button on the 
mouse to complete Stream 3. 
Let’s draw Stream 4 from the top of the flash tank.  Move the cursor near the top of the flash tank until 
the black arrow appears.  Press the left button on the mouse.  Now, draw the stream up about an inch 
and over to the left until it is directly over the first heat exchanger, then try to draw the stream down.  You 
will notice you cannot do it; the entire line moves down with you.  What we need to do is fix horizontal 
latitude to which that line is pegged before we make our turn.  To do this, select your horizontal elevation 
for your cross-stream and press the left button on the mouse.  Now, draw the steam down to the top of 
the heat exchanger.  When that inlet label appears, press the left button on the mouse. 
Using this procedure, complete the rest of the streams until your flowsheet looks like this: 
If you need to delete or reroute a stream, right click on the stream to call the Edit Stream menu.  Use the 
Delete and Re-draw commands as needed. 
When all streams are satisfactorily drawn, click on a vacant spot on the flowsheet and the palette will 
reappear. 
We are now finished drawing our flowsheet. 
SELECTING COMPONENTS 
To move on, we need to activate the Simulation mode.  To do this, click on the Mode menu and select 
the Simulation option or pick the Simulation option of the Mode combo box on the command button 
bar.  The palette will close and the input functions will become available. 
Next, let’s identify which components are to be used in this simulation.  This could be done by selecting 
the ThermoPhysical
command or; the following menu will open up: 
User’s Guide 
CHEMCAD Version 5.5 
52 
To choose components from the standard CHEMCAD databank, click the Component List option with 
the mouse.  The following Component Selection dialog box will appear.  This dialog box is organized as 
indicated below: 
"Selected Components" area: The current list of selected components will be displayed in this area. 
"Component Databank" area: All components stored in the databank(s) are listed here.  Components 
are listed in order of their ID numbers.  When this area is active, a blue highlight will identify one of 
the components. 
Insert button: This button is used to insert a component somewhere in the component list rather than 
appending to the end of the list.  
"Selected Components" area
Delete button
Clear button
Selection string field 
"Component Databank" area 
Add button
Insert button
Next button 
Copy Components Button
n
Documents you may be interested
Documents you may be interested