how to open pdf file on button click in c# : Find and replace text in pdf control application system azure html wpf console RSI02_0E0-part1086

Subject to change – J. Butz, 01.07 – RSI02_0E
Products: R&S® Network Analyzer ZVA, ZVB, ZVT 
Transfer of Trace Data   
From R&S
®
Network Analyzer ZVx 
To Microsoft™ Excel™ 
Application Note 
This application note describes how to directly transfer S-Parameter Trace Data from R&S
®
Network 
Analyzers to Microsoft™ Excel™ using a direct connection like GPIB or LAN 
Find and replace text in pdf - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
how to select text in pdf image; pdf searchable text
Find and replace text in pdf - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
how to search a pdf document for text; pdf editor with search and replace text
Transfer of Trace Data from R&S ZVx to MS Excel 
RSI02_0E 
Rohde & Schwarz 
Contents 
1.
Overview.............................................................................................2
2.
Preparation..........................................................................................2
2.1.
GPIB for Control PC.........................................................3
2.2.
Preparations for LAN: RSIB32.dll.....................................3
2.3.
LAN/Ethernet...................................................................4
2.4.
LAN/Ethernet using direct Crossover connection between 
PC and Network Analyzer...............................................................6
3.
Operation of the Trace-to-Excel Tool...................................................6
3.1.
Screen of Trace-to-Excel-Tool .........................................7
3.1.1.
Resource String of instrument.......................................7
3.1.2.
Instrument Identification................................................8
3.1.3.
Instrument Execution Button for download of trace data8
3.1.4.
Frequency List..............................................................9
3.1.5.
Real and Imaginary Part of S-Parameter Trace Data ....9
3.1.6.
Magnitude (dB) and  Phase parameter of S-Parameter 
Trace Data...............................................................................10
3.2.
Graphical Result View in Excel™...................................10
3.2.1.
Magnitude View Trace_LogMag..................................11
3.2.2.
Magnitude View Trace_Phase.....................................11
4.
Changing the Macro Source Code.....................................................12
5.
Hardware and Software Requirements...............................................14
5.1.
PC Hardware Requirements...........................................14
5.2.
PC Software Requirements............................................14
6.
Literature...........................................................................................14
7.
Additional Information........................................................................14
8.
Ordering information..........................................................................15
1. Overview 
This application note describes how to directly transfer S-Parameter Trace 
Data from R&S
®
Network Analyzers to Microsoft™ Excel™ using a direct 
connection like GPIB or LAN. 
Prerequisites  are  a  PC  running  Microsoft  Excel™,  a  R&S®  Network 
analyzer  like  ZVA,  ZVB  or  ZVT  as well  as a working remote control 
connection between PC and instrument like GPIB or LAN/Ethernet. . 
2. Preparation 
In order to use this application note, you need a remote control connection 
between the PC operating MS Excel™and the R&S® Network Analyzer. 
There are following possibilities for this connection: 
1.  GPIB 
VB.NET PDF replace text library: replace text in PDF content in vb
and ASP.NET webpage. Find and replace text in PDF file in preview without adobe PDF reader component installed. Able to pull text
pdf searchable text converter; pdf find text
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
When you have downloaded the RasterEdge Image SDK for .NET, you can unzip the package to find the RasterEdge.Imaging.PDF.dll in the bin folder under the root
can't select text in pdf file; how to make pdf text searchable
Transfer of Trace Data from R&S ZVx to MS Excel 
RSI02_0E 
Rohde & Schwarz 
2.  LAN/Ethernet using Intranet or Internet 
3.  LAN/Ethernet  using  direct  Crosslink  connection  between  PC  and 
Network Analyzer 
2.1. GPIB for Control PC 
In order to use the GPIB interface, your PC must be equipped with a GPIB 
interface hardware.  
In addition, the remote control library “VISA” needs to be installed on the 
PC. The VISA library is available e.g. at www.nationalinstruments.com
2.2. Preparations for LAN: RSIB32.dll 
This  Application  Note  shows  how  to  use  remote  control  of  Rohde  & 
Schwarz Network Analyzers over a local area network. Rohde & Schwarz 
VXIpnp instrument drivers are based on VISA. Instrument Drivers as well 
as this Trace-To-Excel application can control the instrument via LAN if 
the RSIB interface and passport are installed.  
The RSIB interface is a  R&S®  defined protocol  that uses the  TCPIP 
protocol for communication with the instrument. It consists of a set of I/O 
functions very similar to the National Instruments NI-488.2 interface for 
GPIB.  
The following table shows some corresponding functions:  
A more detailed explanation of RSIB can be found in the Rohde&Schwarz 
application note 1EF47, “Remote Control of R&S® Spectrum and Network 
Analyzers  via  LAN”.  This  application  note  is  available  at www.rohde-
schwarz.com
. The application note comes together with the RSIB Passport 
as well as the necessary RSIB.dll library.  
Please install the RSIB32.dll library into the Windows System folder of 
your remote control PC. 
VB.NET PDF File & Page Process Library SDK for vb.net, ASP.NET
document. If you find certain page in your PDF document is unnecessary, you may want to delete this page directly. Moreover, when
search a pdf file for text; cannot select text in pdf
VB.NET Create PDF Library SDK to convert PDF from other file
Create writable PDF file from text (.txt) file in VB.NET To get this RasterEdge PDF document file creator library the RasterEdge .NET Image SDK and find the PDF
find and replace text in pdf file; pdf text search tool
Transfer of Trace Data from R&S ZVx to MS Excel 
RSI02_0E 
Rohde & Schwarz 
2.3. LAN/Ethernet 
Both, PC and Instrument must be connected to the Local Area Network 
LAN and have a valid IP address inside the LAN. You can check the IP 
adress of your PC from the Windows Control Panel inside the Network 
Connections.  
For  the  R&S  Network  Analyzer  instrument,  please  check  first  if  the 
automatic assignment of an IP address (DHCP) is activated.  
 Press the “Windows” button on the ZVx frontpanel in order to 
display the Windows Taskbar 
 Open  Start->Settings->Network  Connections->Local  Area 
Network Connection 
 In  the dialog, select  “Internet  Protocol (TCP/IP)  and  go to 
“Properties” 
C# HTML5 PDF Viewer SDK deployment on Visual Studio .NET
C#.NET rotate PDF pages, C#.NET search text in PDF, C# Unzip the download package and you can find a project Once done debugging with x86 dlls, replace the x86
how to make a pdf file text searchable; search pdf documents for text
VB.NET PDF - Deploy VB.NET HTML5 PDF Viewer on Visual Studio.NET
C#.NET rotate PDF pages, C#.NET search text in PDF, C# Unzip the download package and you can find a project Once done debugging with x86 dlls, replace the x86
converting pdf to searchable text format; pdf search and replace text
Transfer of Trace Data from R&S ZVx to MS Excel 
RSI02_0E 
Rohde & Schwarz 
- Make sure that the settings are “Obtain IP address automatically” and 
“Obtain DNS address automatically” 
After confirmation of the automatic network settings, please  check the 
obtained Network Analyzer IP address. You can do this in the following 
way: 
 Press Info Button 
 Press the softkey “Hardware Info” 
 Now you can find the IP address of the analyzer below the “IP 
adresses” section 
C# PDF File Permission Library: add, remove, update PDF file
Text: Replace Text in PDF. Image: Insert Image to PDF. Image: Remove read PDF, VB.NET convert PDF to text, VB.NET the following code table, you will find a piece
pdf make text searchable; select text pdf file
VB.NET PDF File Permission Library: add, remove, update PDF file
Text to PDF. Text: Delete Text from PDF. Text: Replace Text in PDF. NET rotate PDF pages, C#.NET search text in PDF In the following code table, you will find a VB
cannot select text in pdf file; find and replace text in pdf
Transfer of Trace Data from R&S ZVx to MS Excel 
RSI02_0E 
Rohde & Schwarz 
Please note that the ZVx instrument has two LAN ports. Depending on the 
port you are using, please use the first or second IP adress in the 
Hardware info field.  
 Final  preparation  step:  Make sure  that  you  have the  LAN 
remote control library RSIB32.dll installed on your PC remote 
computer (see section 2.2).  
2.4. LAN/Ethernet using direct Crossover connection between 
PC and Network Analyzer  
You  can  also  directly  connect  your  remote  PC  to  the  ZVx  Network 
Analyzer instrument by means of a normal LAN cable or by a crossover 
LAN cable.  
A crossover LAN cable has same connector types as a normal LAN cable, 
however the wires inside the crossover cable are crossed.  
3. Operation of the Trace-to-Excel Tool 
This application note comes with an Excel™file tool which enables you to 
directly transfer S-parameter trace data from Instrument to Excel™.  
The supplied Excel-file ZVx_TraceToExcel.xls consists of a spreadsheet 
and a software macro function written in Visual Basic for Applications VBA.  
When opening the file ZVx_TraceToExcel.xls, you will be asked to enable 
the macros. Attention: It is absolutely necessary to press “Enable Macro” 
here. The tool will not work without the macros.  
Transfer of Trace Data from R&S ZVx to MS Excel 
RSI02_0E 
Rohde & Schwarz 
3.1. Screen of Trace-to-Excel-Tool 
After opening the Excel™tool, you will find see a spreadsheet as shown 
below: 
The spreadsheet consists of following elements: 
 Resource String 
 Instrument Identification 
 Execution Button for download of trace data 
 Frequency List 
 Real and Imaginary Part of S-Parameter Trace Data 
 Magnitude and Phase of S-Parameter Trace Data 
3.1.1. Resource String of instrument 
This string is located in cell “B1” of the Excel™spreadsheet (green color). 
Depending on the interface type, a different resource string is used to 
address the instrument.  
GPIB Interface: 
Use Resource  String “GPIB0::20::INSTR”, where “GPIB0” = Name of 
GPIB interface and “20” = GPIB address of Network Analyzer 
LAN Interface: 
Transfer of Trace Data from R&S ZVx to MS Excel 
RSI02_0E 
Rohde & Schwarz 
Use Resource String “RSIB::89.13.1.241::INSTR”, where “RSIB” = Name 
of interface, don’t change,  and “89.13.1.241” = actual IP address of your 
network Analyzer 
3.1.2. Instrument Identification 
This string is located in cell “B2” of the Excel™spreadsheet (light blue 
color). The instrument identification string shows instrument type, model, 
serial number as well as FW version. The string is updated after each 
trace download from the instrument.  
In the neighboring cell “C2”, you can find the detected number of ports 
(orange color). 
In case of any problem with the instrument connection, there will be the 
message “Instrument not found” in this cell. 
The string corresponds to the return value of the “*IDN?” remote control 
command.  
3.1.3. Instrument  Execution  Button  for  download  of  trace 
data 
With this button you can execute the download of the trace data from the 
instrument.  
After execution of this button, you will be promted with a dialog box where 
you can select one of several S-Parameters. The selection is depending 
on the instrument number of ports: 
Transfer of Trace Data from R&S ZVx to MS Excel 
RSI02_0E 
Rohde & Schwarz 
Dialog for 2-port instrument 
Dialog for 4-port instrument 
After pressing the “Download” button, the trace data of the selected S-
Parameter will be transferred to MS Excel™ .  
If the  current instrument  setup contains several channels,  the  Excel™  
Macro will use the currently active channel settings for the trace download.  
3.1.4. Frequency List 
After  the  successful  download  of  the  trace  data,  you  will  find  the 
corresponding frequency list in column A (pink color). 
3.1.5. Real and Imaginary Part of S-Parameter Trace Data 
After the successful download of the trace data, you will find the trace data 
in complex format in the columns B and C (yellow color). Column B shows 
the real value, Column C the imaginary value. The values are entered in 
the corresponding rows next to the corresponding frequency point.  
This data is the actually downloaded data.  
Transfer of Trace Data from R&S ZVx to MS Excel 
RSI02_0E 
10 
Rohde & Schwarz 
3.1.6. Magnitude (dB) and Phase parameter of S-Parameter 
Trace Data 
The Mag(dB) and phase values of the trace can be found in columns D 
and E, respectively (light green color). This data is actually not directly 
downloaded from the instrument, but it is calculated with Excel™functions 
from the available real and imaginary values in the columns to the left.  
3.2. Graphical Result View in Excel™  
With the graphical functions inside MS Excel™ , it is easily possible to 
display the downloaded trace data as a diagram.  
An example is shown in ZVx_TraceToExcel.xls in the two diagram pages 
Documents you may be interested