Configuration tasks in the SIMATIC Manager configuration dialog 
7.3 Step 1 - Configuration of the Batch process cell 
Configuration guidelines SIMATIC BATCH for WinCC 
Programming and Operating Manual, 05/2013, A5E02829586-03 
81
Excel 
column 
Name 
Meaning 
Hierarchy 
Batch instances must be sorted into a plant hierarchy. The following hierarchy is 
supported for the import: 
Process cell subcatalog (optional) 
Unit catalog 
Equipment phase (optional) 
Example: 
Enter the plant subcatalog (if available), the unit catalog, the catalog of the 
equipment phase (if available) and the function name as a parameter of a 
function. 
PCell subfolder 
Units can be grouped in a process cell catalog. If nothing is specified, units are 
generated directly below the process cell. 
Unit_Name 
For unit instances: Name of the unit, e.g. Reactor001. 
For EPH instances: Name of the unit for which the EPH should be created 
Starting with column G, the information is only relevant for EPH and their 
parameters. 
EMOD 
Equipment phase catalog  
If nothing is specified, EPHs are generated directly below the unit. 
EPH_Name 
Name of the EPH, e.g. Heating. 
Starting with column I, the information is only relevant for an EPH (except for 
column M). 
Paraname 
Name of the parameter as specified when the function type was created, e.g. 
SP_Time. 
Def Value 
Default for the setpoint. 
Lower Limit 
Lower limit of the parameter 
This information only relates to the data types, Integer, Real, PI and PO. 
Upper Limit 
Upper limit of the parameter. This information only relates to the data types, 
Integer, Real, PI and PO. 
Description 
Description box 
Search pdf files for text - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
converting pdf to searchable text format; how to make a pdf file text searchable
Search pdf files for text - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
how to select text in pdf reader; pdf text searchable
Configuration tasks in the SIMATIC Manager configuration dialog 
7.4 Step 2 - Configuration of the Batch stations 
Configuration guidelines SIMATIC BATCH for WinCC 
82
Programming and Operating Manual, 05/2013, A5E02829586-03 
7.4
Step 2 - Configuration of the Batch stations 
Introduction 
In this task, you configure the BATCH server, any redundancy server used and the BATCH 
clients used. 
Requirement 
Step 1 of the plant editor has been fully completed without error. 
Procedure 
1.
Enter the computer name of the BATCH server. 
2.
If you use a redundancy server, enter the corresponding computer name. Otherwise, 
leave this field empty. 
VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.
be easily edited), is less searchable for search engines are able to perform high fidelity PDF to HTML Converted HTML files preserve all the contents of source
search multiple pdf files for text; can't select text in pdf file
C# PDF Convert to Text SDK: Convert PDF to txt files in C#.net
DotNetNuke), SharePoint. All text content of target PDF document can be copied and pasted to .txt files by keeping original layout. C#.NET
how to select all text in pdf; search pdf files for text
Configuration tasks in the SIMATIC Manager configuration dialog 
7.5 Step 3 - Configuration of the WinCC stations 
Configuration guidelines SIMATIC BATCH for WinCC 
Programming and Operating Manual, 05/2013, A5E02829586-03 
83
3.
You can add BATCH clients to the list using the "Add" button. You can correct any errors 
that occur by double-clicking on the respective list entry or by deleting it with the "Delete" 
button. 
4.
Once all computer names have been entered, close this task by clicking "Forward". 
Result 
The information in your project relating to the BATCH PCs (server, clients) used has been 
entered in the configuration file and you can continue with the next task. 
7.5
Step 3 - Configuration of the WinCC stations 
Introduction 
In this task, you will configure your Batch system and the WinCC stations used. 
VB.NET PDF Convert to Text SDK: Convert PDF to txt files in vb.net
Convert PDF to text in .NET WinForms and ASP.NET project. Text in any PDF fields can be copied and pasted to .txt files by keeping original layout.
search a pdf file for text; search text in pdf using java
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
Images. File and Page Process. File: Merge, Append PDF Files. File: Split PDF Rotate a PDF Page. PDF Read. Text: Extract Text from PDF. Text: Search Text in PDF.
search text in multiple pdf; select text in pdf file
Configuration tasks in the SIMATIC Manager configuration dialog 
7.5 Step 3 - Configuration of the WinCC stations 
Configuration guidelines SIMATIC BATCH for WinCC 
84
Programming and Operating Manual, 05/2013, A5E02829586-03 
Requirement 
Step 2 of the plant editor has been fully completed without error. 
Procedure  
1.
Simatic Batch Server: If you select the check box, the BATCH component "SBS" will be 
deactivated. Communication between SIMATIC BATCH and the Historian is then not 
possible. This is the default setting. If the check box is not selected, the SBS is activated 
and communication is possible. 
2.
Batch data management (CDV): If you select the check box, the BATCH component 
"CDV" will be deactivated. This is the default setting of the option. This means that no 
BATCH messages and no tag archive data will be collected. This setting is not changed 
over in running operation. Restart the CDV server application. If the check box is not 
selected, batch data management is activated; BATCH messages and tag archive data 
will be collected. 
3.
Message language Select the message language in which the batch data management 
(CDV) will collect the BATCH messages from a drop-down list box. 
4.
Click "Add…" to insert a WinCC station in the list. 
5.
First, enter the UNC path for your WinCC project file (*.mcp). For example: 
\\WinCCServer\WinCCProject\Project.mcp). 
6.
Select the type of WinCC station involved. 
7.
If your WinCC server is intended as an alarm OS, activate the corresponding check box. 
8.
Enter the new server in the list with the "OK" button. 
9.
Add all WinCC PCs used in the same way. 
10.
You can use the "Properties…" button to check the individual entries and change them if 
needed. 
11.
When all WinCC stations have been entered, you can close this task by clicking 
"Forward". 
Result 
The information in your project relating to the WinCC stations used has been entered in the 
configuration file and you can continue with the next task. 
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
File: Merge, Append PDF Files. |. Home ›› XDoc.PDF ›› VB.NET PDF: Merge and Append PDF. VB.NET Demo code to Combine and Merge Multiple PDF Files into One.
convert a scanned pdf to searchable text; search pdf files for text programmatically
VB.NET Create PDF from Text to convert txt files to PDF in vb.net
Images. File & Page Process. File: Merge, Append PDF Files. File: Split PDF Document. PDF Read. Text: Extract Text from PDF. Text: Search Text in PDF. Image
how to search a pdf document for text; how to select all text in pdf file
Configuration tasks in the SIMATIC Manager configuration dialog 
7.6 Step 4 - Distribution of the Batch process cell data 
Configuration guidelines SIMATIC BATCH for WinCC 
Programming and Operating Manual, 05/2013, A5E02829586-03 
85
7.6
Step 4 - Distribution of the Batch process cell data 
Introduction  
In this task, you will distribute the configuration to the previously specified Batch stations. 
Requirements  
●  Step 3 of the configuration dialog has been fully completed without error. 
●  All configured Batch stations are available per network. 
Procedure  
1.
Click "Distribute" to download the configuration to the Batch stations. This may take some 
time, depending on the number of Batch stations and the network connection. 
2.
Once the distribution and download have been performed without error, close the 
configuration dialog by clicking "Exit". 
C# Create PDF from Text to convert txt files to PDF in C#.net, ASP
Images. File and Page Process. File: Merge, Append PDF Files. File: Split PDF Rotate a PDF Page. PDF Read. Text: Extract Text from PDF. Text: Search Text in PDF.
pdf find text; how to select text in pdf and copy
C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net
HTML webpage will have original formatting and interrelation of text and graphical How to Use C#.NET Demo Code to Convert PDF Document to HTML5 Files in C#
how to make a pdf document text searchable; how to select text in a pdf
Configuration tasks in the SIMATIC Manager configuration dialog 
7.7 Validation 
Configuration guidelines SIMATIC BATCH for WinCC 
86
Programming and Operating Manual, 05/2013, A5E02829586-03 
Result 
You have transferred the configuration to the Batch stations and are finished with this part of 
the project configuration. 
Errors and warnings  
The "bfTransOS.xml" file is generated during the transfer of the Batch messages to the 
Operation Station (OS) and is stored in the project directory. It contains the errors and 
warnings that occurred during the transfer.  
The file "PlausiResult.xml" contains errors and warnings that occurred during the BATCH 
configuration, for example a missing runtime name corresponds to a warning.  
Double-clicking the files opens them in the Internet Explorer for error analysis. 
7.7
Validation 
Introduction  
After importing the Batch instances, check your Batch configuration in the "Configure Batch 
Process Cell..." BATCH project configuration dialog. 
Requirements 
●  The Batch instance have been successfully imported. 
●  If the configuration dialog is no longer open, start it again. 
Procedure 
1.
Click the "Processing batch types" button again in Step 1 of the configuration dialog to 
open the "Configure Batch Process Cell" BATCH project configuration dialog. 
2.
In the dialog box, select the "Batch Instances" folder and click "Validate". 
No error or warning should appear in the "Log" area. 
3.
Click "OK" to close the dialog box. 
Result 
The imported Batch data match the configured Batch types. 
Configuration guidelines SIMATIC BATCH for WinCC 
Programming and Operating Manual, 05/2013, A5E02829586-03 
87
Process picture for units and equipment phases 
8
8.1
Introduction 
Visualizing and generating status changes  
In order to visualize and to generate BATCH status changes on an Operation Station in 
process mode, create a process picture with different BATCH Controls in your WinCC 
project in the Graphics Designer. 
8.2
Creating a process picture 
Introduction  
The WinCC process picture is created in the Graphics Designer. The following BATCH 
Controls are used: 
BATCH Control name 
What does the Control provide? 
Process picture areas 
BF_UNIT_Batch_Ctrl 
Representation and operation of the unit 
Representation of batch data. 
This Control is used for the 
operation and representation of 
the unit. 
BF_EPH_Batch_Ctrl 
Representation of batch data with link to the BATCH 
Control Center. 
BF_EPH_Function_Ctrl 
Operation of equipment phases. 
BF_EPH_Parameter_Ctrl 
Representation of function parameters (setpoints) 
These three Controls are used 
for the operation and 
representation of the equipment 
phase. 
Requirements 
●  A new process picture is opened in the Graphics Designer. 
●  The object palette is opened. 
Procedure 
1.
Click "Control" in the object palette in the "Smart objects" folder. 
2.
Drag a free rectangle while holding the left-hand mouse button pressed in the graphics 
working area and release the left-hand mouse button. In the "Insert Control" dialog that 
opens select "BF_UNIT_BATCH Control". 
3.
Use this method to insert all the further BATCH Controls, the BF_EPH_BATCH Control, 
the BF_EPH_Function Control and the BF_EPH_Parameter Control into your process 
picture. 
Process picture for units and equipment phases 
8.2 Creating a process picture 
Configuration guidelines SIMATIC BATCH for WinCC 
88
Programming and Operating Manual, 05/2013, A5E02829586-03 
4.
Arrange all the inserted BATCH Controls as shown in the graphic below. Adapt their sizes 
and move them together. 
5.
Store your process picture, for example under the name "Plant001.pdl". 
Process picture for units and equipment phases 
8.3 Dynamizing a process picture 
Configuration guidelines SIMATIC BATCH for WinCC 
Programming and Operating Manual, 05/2013, A5E02829586-03 
89
Result 
The "Plant001.pdl" process picture can have an appearance as follows. 
8.3
Dynamizing a process picture 
8.3.1
Dynamizing a unit 
Introduction  
You have to dynamize the BATCH Control for the unit "Plant001". To do so, edit the 
properties and events of the "BF_UNIT_Batch_Ctrl" Control in the Graphics Designer. With 
the help of the Dynamic Wizard, you can conveniently link the control to the corresponding 
tag structure for "IUNIT_BLOCK". This means that you can transfer the tag names for the 
Control properties and Control events from the template pictures or spreadsheets directly 
into your project configuration. The Wizard automatically fills the tag names with the selected 
structure instance names. 
Process picture for units and equipment phases 
8.3 Dynamizing a process picture 
Configuration guidelines SIMATIC BATCH for WinCC 
90
Programming and Operating Manual, 05/2013, A5E02829586-03 
Requirements 
●  The "Plant001.pdl" process picture is open in the Graphics Designer. 
●  The corresponding program code for the C-actions can be copied directly via the 
clipboard into the editing field at the corresponding operating steps. 
Table 8- 1 
Program code for the object event "Start BCC" 
Program code 
#pragma code ("ssmrt.dll") 
#include "ssmrt.h" 
#pragma code () 
#define KEY_SIZE 260 
char Screen = '1'; 
char RegEntry[KEY_SIZE] = ""; 
char ProgramName[] = "bfbatchccx.EXE /W WinCC"; 
CMN_ERROR Err; 
/* check registry entry for installed batch-application */ 
SSMRTGetRegistryString ("SOFTWARE\\Siemens\\AUTSW\\BATCH",  
"Path",  
"@", 
RegEntry,  
KEY_SIZE,  
&Err); 
if ( RegEntry[0] != '@' ) 
if ( RegEntry[strlen(RegEntry)-1] != '\\' ) 
strcat( RegEntry, "\\"  ); 
strcat( RegEntry, ProgramName ); 
SSMProgramStart(lpszPictureName, lpszObjectName, RegEntry); 
Table 8- 2 
Program code for the property of the "PermissionLevel" attribute  
Program code 
long levelretval = 0; 
if  ( SSMCheckAreaLevelPermission( lpszPictureName, 5)) 
{levelretval = 5; return levelretval ;} 
if  ( SSMCheckAreaLevelPermission( lpszPictureName, 6)) 
{levelretval = 6; return levelretval ;} 
Documents you may be interested
Documents you may be interested