how to open pdf file using c# : Search pdf files for text programmatically Library control component .net web page html mvc synhdbk10-part1420

SYNCHRO/RESOLVER CARDS
the  DSC-11524,  DSC-11520  and  DR-11525. The
DSC-11524 16-bit hybrid allows you to simulate 6.8
volt sin/cos or 11.8 volt L-L synchro/resolver outputs
with accuracy up to 2 arc minutes. A drive capability
of 15 mA allows for an external 11.8 volt L-L to 90
volt L-L step-up transformer to be connected to the
PC (DDC P/N 51538). The DSC-11520 16-bit hybrid
allows you to simulate 11.8 volt L-L synchro or 6.8
volt sin/cos with an accuracy up to 1 arc minute.The
DR-11525 16-bit hybrid is designed for high frequen-
cy applications (up to 10 kHz) and will allow you to
simulate 11.8 volt L-L resolver or 2 volt sin/cos.Both
the DSC-11520 and DR-11525 have a drive capabil-
ity  of  2mA.
For  wraparound  testing  of
synchro/resolver-to-digital converters or driving high
impedance loads this low cost card gives you the
ability to accurately simulate synchro or resolver out-
puts. Wiring configurations are shown in Figure 10.3.
If more drive capability is required, the DSC-36022
one- to four-channel PC-based card has sockets for
the DSC-644 and DSC-544 modular digital-to-syn-
chro/resolver converters. The DSC-644 series con-
verter will provide 1.5 VA of drive at 11.8 V L-L syn-
chro and resolver or 90 V L-L synchro. When using
the DSC-644 modules you will also require an exter-
nal ±15 DC voltage supply. The DSC-544 series will
provide 1.5 VA synchro 90 V L-L at 60 Hz (-I version)
or 4.5 VA at 90 V L-L at 400 Hz (-H version). This is
a reference powered digital-to-synchro converter that
will provide accuracy up to 4 minutes with no exter-
nal DC power supplies required. See Figure 10.4.
97
RH
RL
S1
S2
S3
RH
RL
S1
S2
S3
RH
RL
S1
S2
S3
RH
RL
S1
S2
S3
17
35
36
18
37
17
35
36
18
37
19
S4
S4
R/D 
CONVERTER
S/D 
CONVERTER
DSC-36022
CHANNEL1
RESOLVER
DSC-36022
CHANNEL1
SYNCHRO
WHEN USING DSC-644 MODULE YOU MUST CONNECT ±15 VOLTS TO THE 37-PIN "D" CONNECTOR
SEE DATA SHEET FOR ADDITIONAL CHANNELS
(with DSC-544 
or DSC-644)
(with DSC-644)
Figure 10.4.DSC-36022 Wiring Configurations.
RH
RL
S1
S2
S3
S4
RH
RL
S1
S2
S3
S4
R/D CONVERTER
RH
RL
S1
S2
S3
RH
RL
S1
S2
S3
S/D CONVERTER
SIM-36010
SYNCHRO
(11.8, 90 V L-L)
SIM-36010
RESOLVER
(11.8 V L-L)
10
9
8
12
11
10
9
8
12
11
7
Figure 10.5.SIM-36010 Wiring Configurations.
Search pdf files for text programmatically - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
how to select text in a pdf; how to select text in pdf
Search pdf files for text programmatically - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
how to search text in pdf document; search pdf files for text
98
SYNCHRO/RESOLVER CARDS
Providing a low-cost alternative to bench top instru-
ments gives today's engineer the tools to properly
evaluate systems at the component level reducing
the cost impact when systems are tested at higher
levels of integration and problems are found. The
SIM-36010 is a full-size PC-based card containing a
broadband (360 Hz to 5K Hz), high accuracy (25 arc
seconds) synchro/resolver simulator instrument on a
card. This card accepts either 26 Vrms or 115 Vrms
reference signal and provides synchro or resolver
output signals at 11.8, 26, or 90 V L-L with a drive
capability of 1.5 VA. The SIM-36010 also includes a
programmable dynamic rotation feature which can
provide a constant rotation from 0.17 /second up to
30.5 rps (wiring shown in Figure 10.5).
The API-36005PC-based angle indicator card is the
complement to the SIM-36010;it is also a broadband
angle indicator that accepts input signals from 360
Hz to 5 KHz and provides an accuracy up to 18 arc
RH
RL
S1
S2
S3
RH
RH
RL
RL
S1
S2
S3
S4
S1
S2
S3
S4
RH
RL
S1
S2
S3
7
8
25
22
12
7
8
25
22
23
24
API-36005
SYNCHRO
(11.8, 90 V L-L)
API-36005
RESOLVER
(11.8 V L-L)
Figure 10.6.API-36005 Wiring Configurations.
seconds. See Figure 10.6 for the API wiring config-
uration.
Software  is  available  in  "C,"  PASCAL,
LabWindows/CVI,  and LabView  for  the  six  cards
described above. The software disk (currently ver-
sion 1.3.x) is shipped with the card. Note:you must
have  National  Instruments  LabWindows/CVI  or
LabView to use the LabWindows/CVI or LabView
files.
There  is  also  a  DLL  and  Library  available  for
Windows 95 and Windows NT. The software pack-
age (currently version 2.x) contains the DLL Library,
sample programs and an executable application that
will exercise the card.
Software can be downloaded from DDC's website at
www.ddc-web.com,  or  obtained  through  DDC's
Literature Department.
C# PDF File Compress Library: Compress reduce PDF size in C#.net
TIFF files compression and decompression method and Image files compression and images size reducing can help to reduce PDF file size Embedded search index.
how to select all text in pdf file; pdf search and replace text
C# Create PDF Library SDK to convert PDF from other file formats
a PDF document in C#.NET using this PDF document creating toolkit, if you need to add some text and draw Create PDF Document from Existing Files Using C#.
search text in pdf using java; pdf find highlighted text
APPLICATION TIPS AND EXAMPLES
In this section we will illustrate a combination of tra-
ditional applications of synchro and resolver convert-
ers and how the increased functionality of the new
generation of converters can be applied to solving
system needs.
Example #1: Coordinate Transformation (Polar to
Rectangular)
Figure 11.1 shows a very useful and fundamental
application of a synchro transducer and converter:to
resolve  a  polar  vector  into rectangular-coordinate
components. One typical application might be in
doing studies of temperature, salinity, conductivity,
PH, or other physical or chemical gradients or distri-
butions in a test tank by scanning a probe around a
fixed-diameter path, one full revolution at each of
several regularly-speeded test times after the initial
excitation of the phenomenon being measured. The
output of the probe is then fed to the inputs of a pair
of analog multipliers, one of which is also fed the sinθ
output of the DC-coupled D/R, and the other of which
is fed the cosθ output of the D/R. Thus, the multipli-
er outputs are proportional to the X and Y coordi-
nates of the vector representing the sensed parame-
ter at the scanning angle θ. These outputs drive the
x and y deflection yokes of a storage oscilloscope (or
the inputs of an X-Y recorder). If there is to be a one-
second scan every 20 seconds, the maximum accu-
rate tracking rate required is 360°/sec or 1 rps.
Note that it is essential that the sineand cosine out-
puts be DC level; that they both be bipolar (four-
quadrant); that they be free of spikes or other tran-
sients; and that they be independent of the refer-
ence-carrier frequency and amplitude (over a rea-
sonable range) and of the scale factor of the CT.
Example #2: Using an S/D in the CT Mode in a
Servo System
One of the most straightforward applications of an
S/D converter in a servo system application is shown
in Figure 11.2. In this application, changes in posi-
99
SECTION XI
Figure 11.1.Polar-to-Rectangular Conversion.
CX
Eref
SYNCHRO-
TO-DIGITAL 
CONVERTER
Es
SHAFT
COUPLED
TO SEARCH
PROBE
EMF GENERATED
BY PROBE
Rf
Rin
10 Cosθ
10 Sinθ
E
1
= Es (Rf/Rin)
M
M
10 E
1
COSθ
10 E
1
SINθ
K
K
Ix = 10K E
1
Cosθ
DEFLECTION
COILS OF
CRT DISPLAY
Z Cosθ
Z Sinθ
Iy = 10K E
1
Sinθ
T5
T4
T3
T2
T1
θ
θ
Z
DIGITAL-TO-
SINE/COSINE
CONVERTER
.NET PDF Document Viewing, Annotation, Conversion & Processing
Merge, split PDF files. Insert, delete PDF pages. Read PDF metadata. Search text content inside PDF. Edit, remove images from PDF. Add, edit, delete links.
search multiple pdf files for text; how to make a pdf document text searchable
VB.NET PDF - Convert CSV to PDF
C#.NET rotate PDF pages, C#.NET search text in PDF to batch convert multiple RTF files to adobe PDF files. are able to convert RTF to PDF programmatically with VB
convert pdf to word searchable text; convert a scanned pdf to searchable text
APPLICATION TIPS AND EXAMPLES
tion are commanded by the computer through sig-
nals fed to the solid-state CT, or Control Transformer.
The synchro is measuring the current position (θ),
and the computer is writing the new position (φ) to
the  CT (an S/D  in the CT mode). The  output  is 
 =  sin(θ-φ). The  CT then drives  the positioning
motors through DC power amplifiers.
Example #3: Using the Velocity (VEL) Output to
Stabilize a Position Loop
With a tachometer quality output, the VEL of the
newer generation of S/Ds and R/Ds can be used to
stabilize a position servo and thereby eliminate the
traditional tachometer and its gears. Figure 11.3
shows  the block diagram  of such an application.
Quite high performance can be achieved in such sys-
tems by taking full advantage of the reference fre-
quency and bandwidth programmability of the newer
converters.
Example #4: Interfacing an S/D or R/D with an
IBM PC
An S/D can be connected to an IBM PC through the
IBM PC or PCI bus located at address HEX 300
through 303. This location is reserved by the PC for
interface cards. Figure 11.4 illustrates the timing
considerations  for  the interface; Figure 11.5 illus-
trates the connection to the IBM PC bus.
Operation is as follows:
1.The port address where the S/D or R/D is located
is  hard  wired  with  jumpers  into  the  74LS688
address  decoder. This  address  is  HEX  300
through 303 and is reserved for prototype cards.
2.Address line A1 selects the upper or lower 8 bits
of the S/D or R/D to be placed on the bus. When
A1 is high, bits 1-8 are selected and when A1 is
low, bits 9-16 are selected.
3. Address line A0 sets and resets the S/D or R/D
INHIBIT line. When A0 is low, the INHIBIT com-
mand (INH
) is invoked or the digital data is frozen.
4.To read the output of the S/D or R/D, perform the
following:
a. Send address HEX 302 to INHIBIT the S/D or
R/D (hold data stable) and place bits 1-8 on the
bus. Read and store data on D0 to D7.
100
Figure 11.2.CT Mode Application.
SYNCHRO
AMP
DEMODULATOR
SDC-19204 
or SDC-14560
as a CT
µ COMPUTER
REF
e = sin (θ − φ)
S
φ
θ
Figure 11.3.S/D with VEL to Stabilize Position.
D/A
COMPUTER
S/D OR R/D
CONVERTER
REF
SOURCE
VEL
AMP
SYNCHRO OR 
RESOLVER
Figure 11.4.PC Application—
I/O Read Cycle Timing.
LATCH READ DATA
OUT
OUT
OUT
IN
OUT
VALID ADDRESS
500nsec MIN PULSE
CLK
ALE
ADDR
I/O
READY
I/O R
C# PowerPoint - PowerPoint Creating in C#.NET
to Create New PowerPoint File and Load PowerPoint from Other Files. searchable and can be fully populated with editable text and graphics programmatically.
text select tool pdf; how to search pdf files for text
C# Word - Word Creating in C#.NET
Users How to Create New Word File and Load Word from Other Files. is searchable and can be fully populated with editable text and graphics programmatically.
search a pdf file for text; how to select text on pdf
APPLICATION TIPS AND EXAMPLES
101
Figure 11.5.S/D Converter to PC Connection Diagram.
BIT 16 (LSB)
BIT 15
BIT 14
BIT 13
BIT 12
BIT 11
BIT 10
BIT 9
BIT 8
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1 (MSB)
D0
D1
D2
D3
D4
D5
D6
D7
Q0
Q1
Q2
Q3
Q4
Q5
Q6
Q7
A9
A8
A7
A6
A5
A4
A3
A2
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
IBM
BUS
BUS DRIVER
74LS465
ADDRESS
DECODER
74LS688
ADDRESS
SELECTION
JUMPERS
74LS374
74LS467
SDC-19204/6
74LS121
Q
A2
INH
EL
EM
Q
CLK
D
Y1
Y2
Y3
Y4
A1
A2
A3
A4
G
G P=Q
ALE
I/O READ
G
A1
A0
I/O READY
3 STATE
BUFFER
500 nSEC MIN
PULSE
P0
P1
P2
P3
P4
P5
P6
P7
A1
A2
A3
A4
A5
A6
A7
A8
C# Word - Word Create or Build in C#.NET
C#.NET using this Word document creating toolkit, if you need to add some text and draw Create Word Document from Existing Files Using C#. Create Word From PDF.
pdf editor with search and replace text; cannot select text in pdf file
VB.NET Create PDF Library SDK to convert PDF from other file
Create writable PDF file from text (.txt) file in VB.NET project. Load PDF from stream programmatically in VB.NET.
search pdf for text in multiple files; pdf select text
APPLICATION TIPS AND EXAMPLES
102
b. Send address 300 HEX to keep the S/D or
R/D in the INHIBIT mode and place bits 9-16 on
the bus. Read and store data on D0 to D7.
c. Read  address  301  HEX  or  303  HEX  to
release the S/D or R/D from the INHIBIT mode
(allow data to track) and prepare for the next mea-
surement. No valid data will be on the bus during
this command.
5.Since the output data is not valid until 0.5 µs after
the INHIBIT command is invoked, the I/O READY
line is held low for this period of time. When I/O
READY returns to the high level, the data on the
bus reads on the next negative clock edge.
Example #5: Using BIT
or “Low Glitch Switch on
the Fly”to Speed Up Slew Rate
In many servo systems it is desirable to slew to a
given point very quickly and then track with some
conflicting  requirements  since  there  is  usually  a
trade off to be made between high speed and high
precision in a servo system. With the new R/Ds
offering  pin-programmable  resolution  and  a  BIT
(Built-in-Test) output you can have the best of both
worlds. By using the BIT
signal to lower the resolu-
tionthe converter can slew faster and with more pre-
cision automatically as the need to slew fast disap-
pears.
Notethat when the resolutionis changed the analog
velocity (VEL) scaling also changes and since the
VEL output is from an integrator with a capacitor
feedback, the VEL cannot change instantaneously.
Therefore, when changing resolution while moving
there will be a transient with a magnitude propor-
tional to the velocity and a duration determined by
the converter bandwidth.
Switch Resolution On The Fly – Implementation
For applications that cannot tolerate the glitch in
position and velocity, switching resolution on the fly
should be used. The RD-19230 will track four times
faster for each step down in resolution (i.e., a step
from 16 bits to 14 bits).The steps for using the sec-
ond bandwidth in the RD-19230 for switching resolu-
tion on the fly are as follows:
1.The SHIFT pin should be tied to the resolution con-
trol line D0.For a set up with 100Hz bandwidth (R
B
= 30k ohms and C
BW
= 0.033 µF), the delay for the
shift line is 250ms maximum. When shift is logic
high, the VEL1 components are chosen, and when
shift is logic 0, the VEL2 components are chosen.
2.The second set of BW components (C
BW
2
, R
B
2
,
C
BW
2
/10) should be of the same value as the first
set of BW components (C
BW
1
, R
B
1
, C
BW
1
/10).This
second set of components should be installed on
VEL
2
and VEL SJ
2
.
Note:The bandwidth components must be cho-
sen so that the tracking rate to BW ratio is not
exceeded for the resolutions that will be used.
3.Connect RVbetween VEL and -VCO.
4.UP
/DN will program the direction of the gain.Prior
to switching the resolution, the user must program
the direction.If the resolution is increasing (UP
/DN
logic 0), the gain will be increased by a factor of
four.
If  the  resolution  is  decreasing 
(UP
/DN logic 1), the gain will be decreased by four
(or decreased to one fourth).
For example:
If the application required a switch between 14- and
16-bit resolution only, the following five steps could
be followed:
i) The shift pin should be tied to the resolution con-
trol  line  D0 and the D1 resolution control  line
should remain a logic high. On initial turn-on, the
D0 and shift line would be set to a logic low for 14-
bit mode. The second set of bandwidth compo-
nents (C
BW
2
R
B
2
, C
BW
2
/10) will be active.
ii) From 14-bit resolution the application is required
to increase the resolution to 16-bits. The gain is
then required to increase. The UP
/DN pin should
be set to a logic low.
APPLICATION TIPS AND EXAMPLES
103
iii) When the condition requiring the higher resolu-
tion is met, the D0 and shift line will be set to a
logic high for 16-bit mode. The first set of band-
width components (C
BW
1
, R
BW
1
, C
BW
1
/10) will be
active.
iv) The next option in the application is to switch
back to 14-bit mode. The UP
/DN pin should be set
to a logic high to prepare the second set of band-
width components for a decrease in resolution.
v) When the condition requiring the lower resolution
is met, the D0 and shift line will be set to a logic
low for 14-bit mode.The second set of bandwidth
components (C
BW
2
,R
BW
2
, C
BW
2
/10) will be active.
Benefit of Switching on the Fly
Figure 11.6 shows a system at a constant velocity
that changes to a higher resolution.The signals that
have been recorded are:
1.VEL:velocity output pin on the RD-19230
2.DAC:this is the analog representation of the error
between  the  input  to  the  digital-to-resolver 
converter and the digital output of the RD-19230
3. D0: an input resolution control line to the RD-
19230
4.BIT:built-in-test output pin of the RD-19230
When this system type does not use the switch res-
olution on the fly implementation, the velocityand the
digital  position  data  response  is  similar  to  the
response caused by a large step (179 degree step -
refer to Figure 11.6). Since this is a type IItracking
loop, the system will:
1 - overshoot the correct value
2 - approach the correct value
3 - overshoot the correct value again
4 - then settle to the correct value
The overshoot will develop a large error [SIN(θ−φ)] in
the converter.This error will exceed 100 LSBs caus-
ing the BIT
to flag for a fault condition.
When this system uses the switch resolution on the
fly implementation, the velocity signal and digital
position data make a smoother transition similar to
the  response  caused  by  a  small  step  (refer  to
Figure 11.6) and the BIT
does not indicate a fault
condition.
Figure 11.6.“Switching On The Fly”Signal Comparisons.
0V
-5V
0V
5V
0V
5V
0V
VEL
DAC
D0
BIT
0V
-5V
0V
5V
0V
5V
0V
VEL
DAC
D0
BIT
50msec per division
50msec per division
Without switching Resolution on the Fly Implementation
With switching Resolution on the Fly Implementation
APPLICATION TIPS AND EXAMPLES
104
Example  #6: Using  Major  Carry (MC)  and
Direction (U) in Multiturn Applications
The MC and U lines of some S/Ds or R/Ds can
be  used in multiturn applications as shown in
Figures 11.7 and 11.8. The MC signal is similar
to the four-bit up-down counter CO (Carry OUT),
that is, it is normally high and goes low for all 1's
when counting up or all 0's when counting down.
The Direction Output, U, is at a logic 1 to count
up and a logic 0 to count down. The logic level
at U is valid at least 0.5 µs before and at least 
20 ns after the leading edge of CB (Converter
Busy).
Example #7: An On-Line Self-Test
In some systems the internal BIT
(Built-in-Test) func-
tion of an S/D or R/D is not adequate and an addi-
tional level of built-in-test is required. One approach,
shown in Figure 11.9, is to connect a solid-state CT
(SSCT) to the input and output of the S/D or R/D and
monitor the Error Output (e) with a threshold detec-
tor. The SSCT inputs are the analog input angle θ
and the S/D output angle (digital) φ. The AC error
output (e) will  be the  difference, or more exactly 
sin(θ - φ). The threshold detector must be set con-
sistent with the accuracy of the S/D or R/D, the SSCT
and the expected transient errors due to acceleration
UP/DOWN
COUNTER
C0
C1
MC
U
CB
U
T
SDC-19204 
OR RDC-19200
4 BITS
TURNS COUNTING
Figure 11.7.Turns Counting Connection Diagram.
DIRECTION (U)
0.5 µs MIN
MAJOR CARRY
MC
DON'T CARE
UP
COUNT
DOWN
COUNT
20 ns MIN
0.5 µs MIN
0.5 µs MIN
0.5 µs MIN
CB
0.5 µs MIN
Figure 11.8.Direction Output (U) Timing.
DIGITAL
COMPARATOR
B.I.T.E.
OUTPUT
REF
DIGITAL
INPUT
D/S OR D/R
CONVERTER
S/D OR R/D
CONVERTER
REF
S3
S1
S2
ANALOG OUTPUT
TO SYSTEM
S4
Figure 11.10.On-Line Self-Test for D/S.
S/D (OR R/D)
CONVERTER
SSCT
CONVERTER
THRESHOLD
DETECTOR
AC ERROR
S1
S2
S3
DIGITAL
OUTPUT
TO SYSTEM
B.I.T.E.
OUTPUT
REF
ANALOG
INPUT
S4
θ
φ
sin (θ − φ)
Figure 11.9.On-Line Self-Test for S/D.
APPLICATION TIPS AND EXAMPLES
105
D/R
CONVERTER
POWER AMPLIFIERS
Vy
Vx
-
+
-
+
MULTIPLE
RESOLVERS
Figure 11.11.Boosting Output of D/R Converter.
D/S
CONVERTER
10k
10k
10k
Vref
TORQUE SYNCHRO
Figure 11.12.Using Two Power Amplifiers to Drive a
Three-Wire Synchro from a D/S Converter.
in the system. The advantage of this scheme is that
it is on line and monitors continuously.
A similar scheme can be implemented for D/S or D/R
converters as shown in Figure 11.10. Here, the D/S
or D/R is followed by an S/D or R/D and a digital
comparator. The same factors must be taken into
consideration here too. Also, be careful to allow
enough settling time for the S/D or R/D, particularly
in the case of step inputs.
Example #8: Boosting the Output of D/S and D/R 
Converters
Figure 11.11 shows the use of differential operational
amplifiers to boost both the average and the peak
power capabilities of a digital-to-resolver converter.
(The same amplifiers may be used to boost the out-
put capabilities of digital-to-synchro, synchro-to-DC
and synchro-to-sine/cosine DC converters). Modern
synchro-drive amplifiers are generally available with
output voltage ranges up to ±90 Volts, at voltampere
levels as high as ±25 VA. They are especially well
suited to driving multiple synchros.
It is important to note that not all high power ampli-
fiers  are  suitable  for  use  as  synchro  drivers
because of the low power factor of the load. In dri-
ving a highly inductive load, most of the real power
must be dissipated in the amplifier, since the cur-
rent levels  and phase  shifts can  be  quite high.
Another important consideration is overload pro-
tection and/or current limiting. If a synchro torque
receiver (TR) locks up at 180° from the D/S con-
verter angle, the TR essentially acts as a generator
aiding the D/S converter output rather than bucking
it as it does in normal operation. In this situation
the amplifier will be called upon to drive the resis-
tive portion of the TR's impedance (Z
SO
) and to
absorb an additional equal current from the TR.
Some form of protection is very desirable in this sit-
uation to prevent burning out the amplifiers and/or
synchro.
Figure 11.12 shows how 
two
external power ampli-
fiers may be used to drive one or more 
three-wire
synchro receivers in parallel (or a high-power torque
synchro). This is possible because of the Y-connec-
tion configuration of the synchro receiver stator wind-
ings. It can be shown that supplying the high-level
energy to two of the three input lines, and directly
connecting the third (ground is the common connec-
tion) is just as effective as using three power boost-
ers. One word of caution: do not allow the ground-
return current from the third terminal to flow through
any of the low-level analog-circuit ground paths -
e.g., the ±15 V power-supply common. Instead, con-
nect the third synchro input directly to the third out-
put terminal on the D/S converter, and ground that
third output terminal to common.
Caution: Modular D/S converters that have trans-
former isolation on the output may have one out-
put tied to ground; hybrid D/S converters that
have amplifier outputs cannot have one output
tied to ground—damage to the hybrid may result.
APPLICATION TIPS AND EXAMPLES
106
MASTER
MOTOR
SLAVE
MOTOR
S/D OR R/D
CONVERTER
SSCT
CONVERTER
SHAFT #1
SHAFT #2
Cx
Cx
REF
MOTOR
CONTROLLER
PHASE
SENSITIVE
DETECTOR
SHAPING
CIRCUIT
AMP
AC
ERROR
START-UP
CIRCUIT
e
REF
Figure 11.13.Synchronizing Two Shafts.
Figure 11.14.Synchronizing Two Shafts (method# 2).
MASTER
MOTOR
SLAVE
MOTOR
S/D OR R/D
CONVERTER
S/D OR R/D
CONVERTER
SHAFT #1
SHAFT #2
Cx
Cx
REF
µP
MOTOR
CONTROLLER
D/A
CONVERTER
SHAPING
CIRCUIT
AMP
REF
Example #9: Synchronizing Two Rotating Shafts
In  some  applications  the  phase  and  speed  of
remotely located shafts must be synchronized as if
they were locked together by gears. This can be
accomplished in two ways.
The first is shown in Figure 11.13. In this method
one shaft (the master) has a CX and S/D or R/D
while the other has a CX and aSSCT. The output of
the master S/D feeds the digital input of the SSCT
whose analog input is the slave shaft CX. The SSCT
output will now be the difference of the input angles,
AC Error (e). This is for use in driving the slave shaft
motor. A separate start-up circuit is needed because
the output of the SSCT is only linear over a small
angular range, usually about 10-12 degrees.
The second method is to simply use two S/Ds or
R/Ds, a µP and a D/A as shown in Figure 11.14. The
advantage of this scheme is the simplified start up
synchronizing because the µP can bring the speeds
Documents you may be interested