Manual Vector XL log Config  
Tree view 
© Vector Informatik GmbH 
Version 4.1 
- 49 - 
On CAN ID 
Trigger if a CAN message with a specified ID is 
received. 
On CAN DLC 
Trigger if a CAN message with a specified DLC is 
received. 
On CAN data 
Trigger if specified CAN data is received. 
On LIN ID 
Trigger if a LIN message with a specified ID is 
received. 
On LIN DLC 
Trigger if a LIN message with a specified DLC is 
received. 
On LIN data 
Trigger if specified LIN data is received. 
On Symbolic message 
Trigger if specified symbolic message is received. 
This dialog will appear if On Symbolic message is 
selected. A message from a previous added 
database can be selected there. 
Pdf searchable text - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
how to select text in pdf and copy; how to select text in pdf image
Pdf searchable text - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
how to search pdf files for text; pdf find and replace text
Tree view 
Manual Vector XL log Config 
- 50 - 
Version 4.1 
© Vector Informatik GmbH 
On Symbolic signal 
Trigger if specified symbolic signal inside a symbolic 
message is received and its condition is valid. 
This dialog appears if  On Symbolic signal is 
selected . A signal from a previous added database 
can be selected there. After the selections has been 
made, the dialog Modify conditions appears. 
On CAN Error frame 
Trigger if an Error frame is received. 
On Start 
Trigger immediately after boot. 
On Sync pulse 
Trigger if sync pulse from synchronization line is re-
ceived. 
On CAN Busload 
Trigger if defined percentage is reached. 
On LIN CRC error 
Trigger if a LIN CRC error occurs. 
On LIN RX error 
Trigger if a LIN Receive error occurs. 
On LIN TX error 
Trigger if a LIN Transmit error occurs. 
On LIN Sync error 
Trigger if a LIN Sync error occurs. 
On LIN sleep 
Trigger if a LIN sleep occurs. 
On LIN wakeup 
Trigger if a LIN wakeup occurs. 
On trigger count 
Trigger if the number of occurred triggers matches 
the defined condition. 
C# PDF Convert to Text SDK: Convert PDF to txt files in C#.net
NET project. Powerful .NET control for batch converting PDF to editable & searchable text formats in C# class. Free evaluation library
convert pdf to searchable text; find and replace text in pdf
Online Convert PDF to Text file. Best free online PDF txt
PDF document conversion SDK provides reliable and effective .NET solution for Visual C# developers to convert PDF document to editable & searchable text file.
convert a scanned pdf to searchable text; search pdf files for text programmatically
Manual Vector XL log Config  
Tree view 
© Vector Informatik GmbH 
Version 4.1 
- 51 - 
Trigger types 
Single trigger 
Triggers always, when trigger condition is valid. 
Starts logging on SD card with set pre and post 
trigger times. Logging can only be stopped by a 
hardware reset 
Single trigger once 
Same as Single trigger but only one time. 
Logging on 
Starts logging on SD card. Logging will stop when a 
Logging off action occurs or by a hardware reset. 
This feature is not available for Multiple file Ring 
buffer. 
Logging off 
Stops logging if it was started by a Logging on 
action before. This feature is not available for 
Multiple file Ring buffer. 
Logging off +  
post-trigger time 
Stops logging if it was started by a Logging on 
action before with additional logging follow-up time. 
This feature is not available for Multiple file Ring 
buffer. 
End measurement 
Stops the measurement. No further logging will be 
done. This feature is not available for Multiple file 
Ring buffer. 
Trigger action 
None 
No action will be done when the trigger occurs. 
Sync pulse 
A sync pulse is generated when the trigger occurs. 
Beep 
A beep on the piezo summer will be generated when 
the trigger occurs 
Beep and sync pulse 
Combination of Beep and Sync pulse (see above). 
Send message… 
Sends a specified CAN message when the defined 
trigger occurs. This trigger action is only available in 
the context menu (right click on the list view Modify 
action | Send message…). Please note that the 
Silent Mode has to be deactivated before (see 
section Channel 1/2 on page 37). 
37). 
VB.NET PDF Convert to Text SDK: Convert PDF to txt files in vb.net
keeping original layout. VB.NET control for batch converting PDF to editable & searchable text formats. Support .NET WinForms, ASP
pdf searchable text; how to make a pdf document text searchable
VB.NET Image: Robust OCR Recognition SDK for VB.NET, .NET Image
for VB.NET provides users fast and accurate image recognition function, which converts scanned images into searchable text formats, such as PDF, PDF/A, WORD
search a pdf file for text; search pdf for text
Tree view 
Manual Vector XL log Config 
- 52 - 
Version 4.1 
© Vector Informatik GmbH 
CCP/XCP command… 
Sends a specified CCP/XCP command. E.g. this 
setting can be used to connect to an ECU or to start 
requesting data, if it was set to No in the CCP/XCP 
Property Panel CONNECT on power-up: 
This trigger action is only available in the context 
menu (right-click on the list view Modify action | 
CCP/XCP command…). 
Available commands: 
None 
No command is sent. 
CONNECT 
If the trigger occurs, the CANcaseXL log tries to 
connect to the specified (database) ECU. 
DISCONNECT 
If the trigger occurs, the CANcaseXL log 
disconnects from specified (database) ECU, if 
possible. 
START 
If the trigger occurs, the CANcaseXL log starts 
measurement (DAQ list must be configured and 
initialized before). 
STOP 
If the trigger occurs, the CANcaseXL log stops 
measurement, if possible. 
INIT 
Re-Initialization of DAQ list for CCP/XCP 
measurement. 
C# PDF: C# Code to Draw Text and Graphics on PDF Document
Draw and write searchable text on PDF file by C# code in both Web and Windows applications. C#.NET PDF Document Drawing Application.
how to search text in pdf document; searching pdf files for text
C# Create PDF Library SDK to convert PDF from other file formats
The PDF document file created by RasterEdge C# PDF document creator library is searchable and can be fully populated with editable text and graphics
text searchable pdf; pdf text searchable
Manual Vector XL log Config  
Tree view 
© Vector Informatik GmbH 
Version 4.1 
- 53 - 
Trigger AND Groups Trigger AND groups can be used to combine several trigger conditions. The group is 
created by a click on the Triggers list view with the right mouse button New group… | 
AND group. The following dialog appears. 
Message ID 
When an AND group is inserted, it can be either message ID dependent or ID 
independent. Instead of specifying a message ID a symbolic name can be chosen 
with the button [Symbolic]. Ensure, that at least one database is listed in Log 
Configuration | Databases. 
ID independent 
AND group 
In certain cases it might be not needed to check for a specified message ID. For this 
purpose change the trigger condition of the AND group (first AND group item) to 
Don’t care. 
Additional conditions For further conditions click with the right mouse button onto the new created AND 
group and select Add trigger condition followed by your desired condition. 
n. 
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit Word
C# users can convert Convert Microsoft Office Word to searchable PDF online, create multi empowered to add annotations to Word, such as add text annotations to
select text in pdf file; how to select all text in pdf file
VB.NET Create PDF from Text to convert txt files to PDF in vb.net
Best VB.NET adobe text to PDF converter library for Visual Studio .NET project. Batch convert editable & searchable PDF document from TXT formats in VB.NET
pdf text search; pdf find highlighted text
Tree view 
Manual Vector XL log Config 
- 54 - 
Version 4.1 
© Vector Informatik GmbH 
AND group validation An AND group contains one ore more additional conditions which are checked 
sequential for their truth, started with the condition of the AND group main item  (first 
item), followed by all inserted items in the AND group. If one if the items is invalid no 
trigger will be fired. 
Example 1: AND group with ID 0x100 and  
- On CAN data[0] == 255 
- Symbolic Signal 1 (ID 0x200) > 20   
- Symbolic Signal 2 (ID 0x100) == 32 
The whole AND group is checked only, when a CAN message with ID 0x100 is 
received. Afterwards the first data byte is checked for value 255, and then the last 
known value of Symbolic Signal 1 (ID 0x200) is checked for greater 20. Please note: 
Values are stored internally for this purpose. If no known value is available the AND 
group validation will abort and no trigger will be fired. Otherwise if the last known 
value of Signal 1 is greater 20, finally the Signal 2 (with 0x100) is checked. In this 
case the value to be checked is the CAN message itself (ID 0x100). If Signal 2 of this 
message is exactly 32 a trigger will be fired here, else not. 
Example 2: AND group with Don’t care and  
- DLC == 5 
- Symbolic Signal 1 (ID 0x200) > 20   
- Symbolic Signal 2 (ID 0x100) == 32 
The whole AND group is checked only, when a message with ID 0x100 or ID 0x200 is 
received. Afterwards the DLC is checked for value 5, and then the last known (or just 
received) value of Symbolic Signal 1 (ID 0x200) and Symbolic Signal 2 (ID 0x100) 
are checked. If the current message signal and the last known value respectively are 
not valid, the AND group validation aborts. 
Example 3: AND group with Don’t care and  
- DLC == 5 
- On CAN data[0] == 255 
The whole AND group is checked when any message is received. Afterwards the 
DLC is checked for value 5 and then the first data byte is checked for value 255. 
Example 4: AND group with ID 0x300 and  
- DLC == 5 
- Symbolic Signal 1 (ID 0x200) > 20   
- Symbolic Signal 2 (ID 0x100) == 32 
The whole AND group is checked only, when a message with ID 0x300 was received. 
Afterwards the DLC is checked for value 5, and then the last known value of 
Symbolic Signal 1 (ID 0x200) is checked for greater 20. Please note: Values are 
stored internally for this purpose. If no known value is available the AND group 
validation will abort and no trigger will be fired. Otherwise if the last known value of 
Signal 1 is greater 20, finally the Symbolic Signal 2 (0x100) is checked. If Signal 2 
is exactly 32 a trigger will be fired here, else not. 
C# Create PDF from Text to convert txt files to PDF in C#.net, ASP
Visual Studio .NET project. .NET control for batch converting text formats to editable & searchable PDF document. Free .NET library for
text select tool pdf; how to select text in a pdf
VB.NET Create PDF from Word Library to convert docx, doc to PDF in
Export all Word text and image content into high quality PDF without losing formatting. Easy to create searchable and scanned PDF files from Word.
pdf make text searchable; find text in pdf image
Manual Vector XL log Config  
Tree view 
© Vector Informatik GmbH 
Version 4.1 
- 55 - 
6.3.4  CCP/XCP 
CCP/XCP 
The CANcaseXL log is able to measure ECU related data over the CCP or XCP. In 
order to do this, a database must be created and supplemented with CCP/XCP 
commands. This supplement can be done in CANape only. After the database has 
been created, it has to be added in the CCP/XCP list view. 
Note: In order to generate a database containing CCP/XCP commands, check the 
following requirements please: 
An existing CANape configuration must exists 
A working ECU must be available in CANape (online measurements) 
Select the desired ECU measurement signals in CANape 
Check the ECU settings in CANape  
Tools | Device configuration… | Edit,  
click [Next] followed by [Driver settigs].  
Open tab Other and activate Generate a CANalyzer database. 
Open tab General and click [Extended driver settings…].  
Scroll down to CANDB_CCP_CONF and set it to Yes. 
Start and stop the measurement to generate the database. 
. 
Info: Polling of measurement signals is not supported. 
Info: A database can also be generated using an A2L file (ASAP2). Detailed 
information can be found in Tools | Generate CCP Database (see chapter  
Tools on page 28). 
Global settings 
The property panel has two options as follows: 
CONNECT on power-up 
If set to yes, the CANcaseXL log tries to connect to the specified (database) ECU 
when it is switched on. 
On communication error 
If the communication to the ECU is broken, the logging can be either stopped or 
continued. 
List view column 
Tree view 
Manual Vector XL log Config 
- 56 - 
Version 4.1 
© Vector Informatik GmbH 
Filename 
Filename of the database. 
Channel 
Channel where the database is assigned to. 
Init delay 
Delay in ms after the CANcaseXL log has been 
switched to logger mode. Afterwards the CCP/XCP 
commands are sent. 
Cmd timeout 
Time segment in which the ECU has to respond to a 
CCP/XCP command. 
Status check 
Enables the cyclically CCP/XCP check of the 
configured ECU. 
Execute cfg 
Enables/disables the transmission of the CCP/XCP 
commands from the database. 
Path 
Location of the database. 
List view   
context menu 
The list view is right click sensitive and offers a context menu as follows: 
Add database… 
Adds a new database. Ensure that this database 
contains CCP/XCP commands. 
Edit database… 
Opens CANdb++ editor for editing. Ensure that 
CANdb++ was installed previously. An installation 
file is found on the installation CD. 
Disable/Enable CCP/XCP 
feature 
Disables or enables the CCP/XCP feature of the 
added database. The database itself is still 
accessible. 
Edit assigned parameters… 
Opens the dialog for CCP/XCP configuration. 
Modify channel assignment… 
Modifies the channel assignment where the 
database is assigned to. 
Remove 
Removed the database from the list view. 
Note: The menu entries depend on the selected item/column in the list view. 
Manual Vector XL log Config  
Tree view 
© Vector Informatik GmbH 
Version 4.1 
- 57 - 
Modify CCP/XCP 
configuration 
This dialog can be opened by a right-click on the list view Edit assignment 
parameters… or by a double-click on an item: 
Init delay 
Cmd timeout 
Status check 
Dialog 
Init delay [ms] 
Delay in ms after the CANcaseXL log has been 
switched to logger mode. Afterwards the CCP/XCP 
commands are sent. 
Connection retry delay [ms] 
Time between a failed connection and next retry. 
Command timeout 
Time segment in which the ECU has to respond to a 
CCP/XCP command. 
Status check method 
Enables the cyclically CCP/XCP check of the 
configured ECU device. 
Execute configuration 
Enables/Disables the transmission of the CCP/XCP 
commands from the database. 
Documents you may be interested
Documents you may be interested