how to upload and view pdf file in asp net c# : Select text pdf file software SDK dll winforms wpf windows web forms Nomad3_UserGuide-M211756EN-A1-part266

NOMAD 3 USER’S GUIDE 
VAISALA 
1-3 
1.3 
RECYCLING 
Recycle all applicable material. 
Dispose of batteries and the unit according to statutory regulations. 
Do not dispose of with regular household refuse. 
1.4 
REGULATORY COMPLIANCES 
The Nomad 3 Data Logger complies with the following performance and environmental test 
standards:  
1.5 
TRADEMARKS 
Vaisala
®
is a registered trademark of Vaisala Oyj 
Nomad
®
is a registered trademark of Vaisala Oyj 
SkyServe
®
is a registered trademark of Vaisala Oyj 
Velcro
®
is a registered trademark of Velcro Industries B.V. 
Windographer
TM
is a trademark of AWS TruePower LLC 
1.6 
SOFTWARE LICENSE 
This product contains software developed by Vaisala. Use of the software is governed by license 
terms and conditions included in the applicable supply contract or, in the absence of separate license 
terms and conditions, by the General License Conditions of Vaisala Group.  
This product may contain open source software (OSS) components. In the event this product 
contains OSS components, then such OSS is governed by the terms and conditions of the applicable 
OSS licenses, and you are bound by the terms and conditions of such licenses in connection with 
your use and distribution of the OSS in this product. Applicable OSS licenses are included in the 
product itself or provided to you on any other applicable media, depending on each individual 
product and the product items delivered to you.  
The software licenses may be viewed at www.vaisala.com/nomad3. 
Select text pdf file - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
pdf search and replace text; search pdf files for text programmatically
Select text pdf file - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
how to select all text in pdf; pdf text search tool
NOMAD 3 USER’S GUIDE 
1-4 
M211756EN-A 
1.7 
WARRANTY 
The Vaisala Nomad 3 Data Logger comes with a standard 12 month warranty.  For standard 
warranty terms and conditions, visit www.vaisala.com/warranty. 
Please observe that any such warranty may not be valid in case of damage due to normal wear and 
tear, exceptional operating conditions, negligent handling or installation, or unauthorized 
modifications. Please see the applicable supply contract or Conditions of Sale for details of the 
warranty for each product. 
C# PDF Image Extract Library: Select, copy, paste PDF images in C#
Extract various types of image from PDF file, like XObject Image, XObject Form, Inline Image, etc. C#: Select An Image from PDF Page by Position.
how to select all text in pdf file; convert pdf to searchable text
VB.NET PDF Image Extract Library: Select, copy, paste PDF images
RsterEdge XDoc PDF SDK for .NET, VB.NET users are able to extract image from PDF page or file and specified VB.NET : Select An Image from PDF Page by
search text in multiple pdf; pdf select text
NOMAD 3 USER’S GUIDE 
VAISALA 
2-1 
CHAPTER 2  TECHNICAL DESCRIPTION 
2.1 
INTRODUCTION 
The Nomad 3 Data Logger is used in both the wind and solar energy industries to record 
environmental measurements made by the leading manufacturers of anemometers, wind vanes, 
pressure, temperature, and humidity sensors, pyranometers, and many other sensors available on the 
market today. Nomad 3 is used in wind and solar resource assessment and condition monitoring for 
renewable energy applications.  
While most commonly used as part of a meteorological tower installation, Nomad 3 can also be used 
as part of a weather station and in more specialized applications. 
2.2 
THEORY OF OPERATION 
The Nomad 3 Data Logger and supporting software comprise an easy-to-use system for measuring 
and recording wind speed, direction, temperature, pressure, and other environmental variables. 
Figure 2-1 summarizes the operation of the Nomad 3.  
1.  The user logs onto the Vaisala SkyServe website. 
2.  The Nomad 3 Toolbox is used to create Nomad 3 setup files to enable site information, sensor 
configuration, telemetry, data transfer and data security.  
3.  The setup files are transferred to the Nomad 3 with a USB flash drive. Vaisala provides an 
offline version of the Nomad 3 Toolbox for users without internet access referred to as the 
Offline Nomad 3 Toolbox.  
4.  When installed in the field, the Nomad 3 records sensor data which can be exported to a USB 
flash drive.  
5.  Nomad 3 can also send data via email or FTP if a modem is present and telemetry is enabled 
using an active SIM card. 
Figure 2-1  Nomad 3 Theory of Operation Diagram 
SkyServe
Setup Files
Data File
VB.NET PDF Text Redact Library: select, redact text content from
Convert PDF to SVG. Convert PDF to Text. Convert PDF to JPEG. Convert PDF to Png, Gif, Bitmap Images. File & Page Process. File: Merge, Append PDF Files. File
select text in pdf file; text searchable pdf file
C# PDF Text Redact Library: select, redact text content from PDF
Enable users abilities to adjust color and transparency while scraping text from PDF file. Able to redact selected text in PDF document.
select text in pdf reader; search pdf for text
NOMAD 3 USER’S GUIDE 
2-2 
M211756EN-A 
2.2.1  NOMAD 3 DATA LOGGER 
The Nomad 3 offers advanced functionality and simplified installation while reducing system costs.  
•  The Nomad 3 Toolbox contains a list of a number of market-leading weather sensors with pre-
loaded parameters for use. Custom slopes and offsets may also be loaded for these sensors as 
well as other sensors not listed. 
•  Utilize up to 12 counter inputs, and 12 analog single-ended or 6 analog differential inputs. 
•  GPS maintains precise time synchronization. 
•  Smart power management extends battery life and an optional solar package keeps the system 
running even longer. The Nomad 3 can also be directly powered from a 12VDC power source. 
•  Remote communication options offer many ways to transmit data via Email and FTP. Once 
activated on SkyServe
through the Nomad 3 Account Manager, the Nomad 3 can send regular 
status updates for effective device health monitoring. 
Figure 2-2  Nomad 3 Data Logger 
2.2.2  SENSORS 
The Nomad 3 Data Logger is designed to work with a majority of market-leading anemometers, 
wind vanes, and other environmental sensors used in the wind and solar industries; 
•  Anemometers to measure wind speed 
•  Wind vanes to measure wind direction 
•  Sensors to measure temperature, humidity, pressure, voltage and other weather and power 
conditions 
There are currently two types of sensor interfaces supported by the Nomad 3:  
•  The anemometer circuits are designed to count on/off pulses and are called Counter Inputs.  
•  The Analog Input interface circuitry connects to voltage-output devices. The Nomad 3 input 
circuits can be configured by creating an Input Setup file and loading it onto the logger with a 
USB flash drive. 
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
is loaded as sample file for viewing on the viewer. See screeshot as below. Tools Tab. Item. Name. Description. 1. Select tool. Select text and image on PDF document
search text in pdf using java; how to select text in pdf and copy
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
is loaded as sample file for viewing on the viewer. See screeshot as below. Tools Tab. Item. Name. Description. 1. Select tool. Select text and image on PDF document
how to make pdf text searchable; how to select text on pdf
NOMAD 3 USER’S GUIDE 
VAISALA 
2-3 
2.2.2.1  COUNTER INPUTS 
Nomad 3 counter inputs (CTR) are designed to measure and record wind speed or other frequency-
based data. Nomad 3 Toolbox Input Setup files control three (3) fundamental settings for each CTR 
that is activated: 
•  Slope: engineering units/Hz (e.g. Meters/second) 
•  Offset: engineering units (e.g. Meters/second) 
•  Threshold: either 0V or 1.4V 
The counter inputs can be configured to operate in two (2) different modes corresponding to the two 
(2) most frequently used types of anemometers.  
The first is an alternating current (AC) output anemometer. These devices are self-powered and are 
preferred for extremely low power applications. The transducer consists of a magnet connected to 
the rotating anemometer cups or propeller and a stationary pick-up coil. The AC output signal 
frequency is in direct proportion to the rotational speed and is the basis of the measurement. The 
input circuits trigger a pulse count when the AC signal crosses zero (ground) potential whether the 
signal is rising or falling. This is designated as 0V threshold in the Input Setup file as shown in 
Figure 2-3. 
Figure 2-3  Input with 0V Threshold 
The circuit used in the 0V threshold mode is designed for the outputs typical of anemometers. As the 
measured input frequency increases, the peak-to-peak voltage also increases and the input circuit’s 
minimum voltage threshold is a function of frequency. The circuit employs a low-pass filter to reject 
noise that might be induced in the sensor cable. The highest frequency that can be measured in this 
mode is 1400 Hz. Figure 3-14 shows two (2) SW/Vaisala C3 anemometers wired to the Nomad 3 
counter inputs. 
The second threshold mode is for a square-wave output anemometer. These types of sensors require 
12V power and are selected to minimize current use. The sensor’s transducer is typically an "optical-
chopper" where a signal from an LED light source is interrupted by a slotted disc rotating on the 
sensor’s shaft. The output voltage is determined by the 12V supply decreased by the 
photodiode/detector loss. The input circuits trigger a pulse count when the signal crosses 1.4 volts 
potential whether the signal is increasing or decreasing. This is designated as 1.4V threshold in the 
Input Setup file as shown in Figure 2-4. 
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit OpenOffice
pptx) on webpage, Convert CSV to PDF file online, convert CSV to save signatures to OpenOffice and CSV file. Viewer particular text tool can select text on all
cannot select text in pdf; how to make a pdf file text searchable
VB.NET PDF - View PDF with WPF PDF Viewer for VB.NET
PDF to text, C#.NET convert PDF to images, C#.NET PDF file & pages Pan around the PDF document. Select text and image to copy and paste using Ctrl+C and Ctrl+V
convert a scanned pdf to searchable text; text searchable pdf
NOMAD 3 USER’S GUIDE 
2-4 
M211756EN-A 
Figure 2-4  Input with 1.4V Threshold 
Refer to Figure 3-17 to see how these sensors are typically wired. The 1.4V threshold setup is also 
used for rain gauges and reed switch devices to discern High vs. Low. This typically requires using a 
10 k-ohm pull-up resistor between the CTR input and 12V. For example, reed-switch anemometers 
are setup this way as shown in Figure 3-13. The highest frequency that can be measured in this mode 
is approximately 2 kHz. 
The 1.4V threshold is also used when the CTR input is used as a State input. The State input is used 
when a simple On/Off state is to be measured and recorded. 
2.2.2.2  ANALOG INPUTS 
Nomad 3 has 12 analog (AN) inputs which can be used in either single-ended mode or in differential 
mode. The Input Setup file controls the voltage range of the input and whether it is used as single-
ended or paired for a differential sensor. 
•  Differential mode requires two (2) available AN inputs in the same connector block. 
•  Single-Ended Mode designates a voltage measurement made with respect to ground and is the 
most commonly used mode. In this mode any of the 12 analog inputs can be configured to 
measure the voltage output of a sensor. This mode is typical for standard potentiometer wind 
vanes which use the 2.5V excitation voltage. Other voltage output sensors require 12V power 
from the Nomad 3 and are called active sensors. The Nomad 3 Toolbox provides default setups 
for a variety of analog temperature, humidity, and pressure sensors. The required settings for 
these sensors are range (2.5V or 5.0V) and scaling (slope and offset). Refer to Figure 3-8 for 
wiring examples of single ended type sensors. 
Analog inputs can be setup in sample mode for slowly varying measurements like temperature or 
barometric pressure. This type of setup uses the 12 volt switched power (12V SW) to minimize 
battery use. The 12 volt supply is turned on continuously when viewing analog inputs on the GUI 
screen. 
The Nomad 3 also has 2.5V excitation for passive sensors like potentiometer vanes and the 
SW/Vaisala thermistor. The 2.5V is pulsed for a brief period (approx. 12 milliseconds) during each 
1-second sample to save power.  The 2.5 volt supply is turned on continuously when viewing analog 
inputs on the GUI screen. 
The input setup for analog wind vanes is different than for other types of single-ended analog 
sensors. An input setup file for analog wind vanes includes settings to note the position and size of 
the North mark, called the deadband for potentiometer vanes. The deadband is the region where the 
sensor is unable to provide a reading. The Nomad 3 supports an algorithm to minimize this error by 
adjusting the scaling based on the arc angle of the deadband. Default settings for the deadband width 
and compass bearing are prefilled in the Nomad 3 Toolbox, though the user is able to enter a specific 
C# WPF PDF Viewer SDK to view PDF document in C#.NET
PDF to text, C#.NET convert PDF to images, C#.NET PDF file & pages Pan around the PDF document. Select text and image to copy and paste using Ctrl+C and Ctrl+V
how to select all text in pdf; select text in pdf
C# WPF PDF Viewer SDK to annotate PDF document in C#.NET
Default create. Click to select drawing annotation with default properties. Other Tab. 17. Text box. Click to add a text box to specific location on PDF page.
how to make a pdf file text searchable; find and replace text in pdf
NOMAD 3 USER’S GUIDE 
VAISALA 
2-5 
value if it differs. Nomad 3 also provides a function to record the instantaneous wind direction at the 
moment of maximum gust as set in the Nomad 3 Toolbox as shown in Figure 2-5. Refer to section 
4.3 to create an Input Setup file using the Nomad 3 Toolbox for an analog wind vane. 
Figure 2-5  Analog Potentiometer Wind Vane Toolbox Setup 
Figure 2-6  Wind Vane Wired for Single-Ended Mode 
Nomad 3 supports a limited range of differential analog input measurement intended to eliminate 
error from using a common ground to power the sensor. Figure 2-7 shows the wiring for a Vaisala 
PTB110 barometer. The sensor power references the ground (GND) terminal, while the analog 
output ground (AGND) is wired to AN 12 (–). The Nomad 3 input connector block shows the 
polarity restrictions for differential mode with a red (+) for the odd inputs and a black (–) for the 
even inputs. 
NOMAD 3 USER’S GUIDE 
2-6 
M211756EN-A 
Figure 2-7  PTB110 Wired for Differential Mode 
A differential pair must be sequential: AN 1(+), AN 2(–); AN 3(+), AN 4(–); etc… The purpose of 
the differential measurement is to eliminate error from sharing power ground. Analog negative (–) 
must be at ground potential or higher; up to 100mV above ground. This is a sufficient range for 
typical low current sensors and cable resistance. 
2.2.3  REMOTE COMMUNICATIONS 
The Nomad 3 Data Logger can be equipped with an optional 2G GSM modem. The user is 
responsible for acquiring a SIM card and setting up a local cellular data plan with a local provider. 
The SIM card is inserted in the modem and allows for data transmission via Email and FTP.  When 
activated on SkyServe, the Nomad 3 can send regular status updates to the Nomad 3 Account 
Manager site.  
NOTE 
It is suggested to test the modem in house to reduce troubleshooting issues 
before field installation of the Nomad 3. 
NOMAD 3 USER’S GUIDE 
VAISALA 
3-1 
CHAPTER 3  INSTALLATION 
3.1 
INTRODUCTION 
This chapter contains instructions for installation of the Nomad 3 Data Logger. 
3.2 
STANDARD DATA LOGGER PACKING LIST 
The following items are included in the delivery of the Nomad 3 Data Logger.  
ITEM 
QUANTITY 
NOTES 
Nomad 3 
1 ea. 
USB Flash Drive 
1 ea. 
Use to load setup files, update firmware, or export 
data direct from the Nomad 3 
0.025" [0.64mm] Flathead Screwdriver  1 ea. 
For use when wiring up sensors to connector blocks 
Quick Start Guide 
1 ea. 
Activation Card 
1 ea. 
Included inside the Nomad 3 enclosure 
Wet Erase Marker w/ Velcro 
1 ea. 
Attach this to the Velcro strip inside the front cover 
of the Nomad 3 
Mounting Hardware Kit 
1 ea. 
Includes two [2] pole mount brackets, four [4] 10-
32×3/8" SEMS screws, and two [2] worm drive 
clamps 
Mounting Foot Kit 
1 ea. 
Option for mounting to flat surface (or inside 
another enclosure) 
USB-A to USB-B Cable 
1 ea. 
For later use when computer to Nomad 3 
communications are available 
Extra 6-32×5/8" SEMS Screws 
2 ea. 
Extra 10-32×5/8" SEMS Screws 
2 ea. 
Extra 5-Pin Terminal Blocks 
2 ea. 
Extra 7-Pin Terminal Blocks 
2 ea. 
NOMAD 3 USER’S GUIDE 
3-2 
M211756EN-A 
3.3 
TOOLS AND EQUIPMENT  
The following tools and equipment are required for installation of the Nomad 3 Data Logger. 
ITEM 
QUANTITY 
USED FOR 
#2 Philips Screwdriver 
1 ea. 
Removing PCB/cover to access modem for SIM installation 
and antenna connection 
5/16" Nut-Driver 
1 ea. 
Securing and tightening hose clamps to tower 
Metal Shears 
1 ea. 
Cutting hose clamps to length for pole mounting 
Wire Strippers 
1 ea. 
Preparing ends of sensor cable for connector termination 
Adjustable Wrench 
1 ea. 
Tightening PG glands 
Electrical Tape 
1 roll 
Ensure safety while wiring power connections 
Box Cutter 
1 ea. 
Cutting cable gland to route terminated cables 
Wire ties 
+20 ea. 
Cable management 
Mini SIM card (optional) 
1 ea. 
Cellular modem communications 
3.4 
SITE INFORMATION 
Site preparation requires that onsite facilities, materials, services, and equipment are completely 
defined and available prior to installation. When installing on a met tower, ensure that all wiring and 
cabling are done properly at the sensor prior to installation. Label sensor cables to facilitate wiring at 
the Nomad 3. 
3.5 
UNPACKING AND REPACKING 
Carefully unpack all equipment from crates and boxes while inspecting for damage.  Retain original 
packaging or similar materials for repacking. 
When storing: 
•  Disconnect all power sources and batteries.   
•  Remove any fuses.   
•  Ensure that any exposed holes in the wiring glands are plugged shut with a short piece of wire or 
a billet plug.   
•  Latch the door shut and store in a warm and dry room.  
•  Do not store outside when not in use. 
3.6 
SITE SAFETY 
Site safety procedures shall be observed when following any and all procedures in this document. 
Documents you may be interested