NOMAD 3 USER’S GUIDE 
VAISALA 
3-13 
3.9.2  TOWER MOUNTING 
The following procedure describes the method for mounting the Nomad 3 to a round tower. The 
bands included in the mounting kit will fit a tower diameter up to 16" [406mm]. Alternate mounting 
methods inside a larger enclosure or to a lattice tower should be planned using the four plastic 
mounting feet instead of the band clamp kit. 
Figure 3-4  Data Logger Enclosure-Tower Mounting 
STEP 
ACTION 
Add 6" [150mm] to the diameter of your tower and cut the two (2) band clamps in the mounting 
kit to length using metal shears. 
Secure the two mounting brackets to the back of the enclosure with the provided 10-32 screws. 
Tighten with a Phillips screwdriver. 
Thread the band clamps through the slots in the mounting brackets. 
Position the enclosure to the tower, and tighten the band clamps to the tower using a 5/16" nut 
driver. 
Pdf text search - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
search a pdf file for text; pdf text search tool
Pdf text search - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
how to select text in pdf and copy; converting pdf to searchable text format
NOMAD 3 USER’S GUIDE 
3-14 
M211756EN-A 
3.9.3  GROUNDING ENCLOSURE 
The following procedure describes the proper method for grounding the Nomad 3. Use of a 6AWG 
ground wire is recommended for use with the Nomad 3 for electrical protection against lightning 
strikes.  
Figure 3-5  Ground Wire Connections 
STEP 
ACTION 
Route a 6AWG ground wire from the ground post along the tower to the bottom of the logger. 
Route the ground wire into the logger through the outer hole in the bottom gland. 
Route the ground wire to the ground lug and tighten in place with a flat head screwdriver. 
C# Word - Search and Find Text in Word
C# Word - Search and Find Text in Word. Learn How to Search Text in PDF Document and Obtain Text Content and Location Information. Overview.
find text in pdf files; pdf find text
C# PowerPoint - Search and Find Text in PowerPoint
C# PowerPoint - Search and Find Text in PowerPoint. Learn How to Search Text in PDF Document and Obtain Text Content and Location Information. Overview.
pdf search and replace text; text searchable pdf file
NOMAD 3 USER’S GUIDE 
VAISALA 
3-15 
3.9.4  CONNECT POWER SOURCE 
If a power source other than the Nomad 3 Power Enclosure is installed, the source must provide 
12VDC at 1.25A with proper fusing. The Nomad 3 requires a minimum of 10.5VDC. Do not exceed 
16VDC. 
WARNING 
Follow all ESD and safety procedures while working on electronic equipment. 
Figure 3-6  Nomad 3 to Power Enclosure Wiring 
C# PDF delete text Library: delete, remove text from PDF file in
The following C# coding example illustrates how to perform PDF text deleting function in your .NET project, according to search option. // Open a document.
how to select text in a pdf; select text in pdf reader
C# PDF replace text Library: replace text in PDF content in C#.net
The following C# coding example illustrates how to perform PDF text replacing function in your .NET project, according to search option. // Open a document.
select text pdf file; make pdf text searchable
NOMAD 3 USER’S GUIDE 
3-16 
M211756EN-A 
STEP 
ACTION 
Mount the power enclosure to tower. Use instructions for the logger enclosure in section 3.9.2. 
Make sure the fused trailer hitch between the battery and the charge regulator is disconnected 
before routing power cables. Twist and pull to disconnect it. 
Route included power cable through bottom cable gland of power enclosure. 
Mount the solar panel to the solar bracket with the adjustable slide clamps. Mount the solar 
bracket to the tower with the included hose clamps. Adjust the direction and angle of the solar 
panel for maximum charging at the site. 
Route the solar panel wires through the gland in the bottom of the Power Enclosure. 
Strip back the jacketing of the power cable and connect the RED wire to X2.5 (DCout/Switch) 
and the BLACK wire to X2.4 (GND) on the Charge Regulator. 
On the logger side, route the other end of the power cable through the PG21 cable gland. Strip 
the wires back and connect the RED wire to 12V Power, and the BLACK wire to GND in the 
two pin connector on the Main PCB. 
Strip back the jacketing of the solar panel wires and connect the RED wire to X1.5 (SOL1in+) 
and the BLACK wire to X1.4 (GND) on the Charge Regulator. Remove the connector for ease of 
routing if needed. 
Remove the slack in all cables routed through the Power Enclosure cable gland and tighten the 
gland nut around the cables. 
10 
Check all wiring is correct and secured properly. Re-connect fused trailer hitch between the 
battery and the Charge Regulator. Twist and push together to connect it. 
VB.NET PDF replace text library: replace text in PDF content in vb
The following coding example illustrates how to perform PDF text replacing function in your VB.NET project, according to search option.
pdf select text; how to select all text in pdf
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
PDF Read. Text: Extract Text from PDF. Text: Search Text in PDF. Image: Extract Image from PDF. Easy to search PDF text in whole PDF document.
how to select text in pdf; pdf text select tool
NOMAD 3 USER’S GUIDE 
VAISALA 
3-17 
3.9.5  CONNECT SENSORS TO DATA LOGGER 
Mount sensors according to the manufacturer’s instructions. Mark each end of the sensor wire to 
identify the sensor connected to it. Follow the steps in this procedure to route the sensor wires to the 
Nomad 3. Follow best practices when wiring sensors such as incorporating a "drip loop" in all 
cabling to prevent water ingress from traveling down the cables in to any connection points. 
STEP 
ACTION 
Plan where to connect each sensor on the front panel (see Figure 3-7). Make note of the terminal 
block (A-F) and the input connector (AN 1-12 or CTR 1-12) for each sensor using the template 
below. The sensor connection information will be used to create an Input Setup file for the 
Nomad 3. 
For installation, use the white board inside the front cover of the Nomad 3 to note the sensor 
connections as well. 
Cut sensor cables to a blunt end except for the GPS cable which has protective tubing over the 
pre-terminated cables. 
Poke a hole in the multi-gland using a screwdriver for each sensor cable. 
Push the cables through the holes in the multi-gland from the outside of the enclosure. 
C# PDF Text Highlight Library: add, delete, update PDF text
The following C# coding example illustrates how to perform PDF text highlight function in your .NET project, according to search option. // Open a document.
search multiple pdf files for text; how to select text in pdf reader
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
Page: Rotate a PDF Page. PDF Read. Text: Extract Text from PDF. Text: Search Text in PDF. Easy to search PDF text in whole PDF document.
search pdf for text in multiple files; search pdf documents for text
NOMAD 3 USER’S GUIDE 
3-18 
M211756EN-A 
STEP 
ACTION 
Remove the protective tube on the GPS cable and route the wires to the GPS input connector. See 
Figure 3-8 for proper wiring. 
Strip the end of the other sensor wires and terminate them to the appropriate input connectors. 
See Figure 3-8 through Figure 3-18 and the sensor manufacturer’s wiring to determine voltage, 
ground and data connections. 
- Analog sensors are connected to the top row (green labels with AN xx). 
NOTE 
For differential analog inputs, the odd AN inputs are positive while 
the even AN inputs are for negative voltage. 
- Counter sensors are connected to the middle row (bright blue labels with CTR xx).  
- Special sensors are connected to the bottom row. 
NOTE 
Special sensors apart from the GPS are not currently available, but 
will be field upgradable with future firmware releases. 
Each sensor block has an earth ground connection (yellow/green) for attaching the shield wire. 
The shield wire is suggested for use to prevent possible lightning damage to the Nomad 3 and the 
sensor. 
Pull the slack out of the wires so that the outside of the gland’s membrane pops back out around 
the cable. 
NOMAD 3 USER’S GUIDE 
VAISALA 
3-19 
Figure 3-7  Input Types and Sensor Wiring 
 ANALOG 
 COUNTER 
 SPECIAL 
NOMAD 3 USER’S GUIDE 
3-20 
M211756EN-A 
Figure 3-8  Sensor Connection for Vaisala Low Power Sensors 
NOMAD 3 USER’S GUIDE 
VAISALA 
3-21 
Figure 3-9  Sensor Connection for NRG Low Power Sensors 
NOMAD 3 USER’S GUIDE 
3-22 
M211756EN-A 
3.9.5.1  ANALOG OUTPUT SENSORS USING DIFFERENTIAL INPUT MODE WIRING 
The following figures show the typical wiring for analog output sensor using differential input mode. 
This wiring is recommended for tower top sensors or cases with very long cables. 
•  Wiring for the Vaisala HMP155 Temperature and Humidity Probe is shown in Figure 3-10. 