Using TestWorks 4
Editing Configuration Items
81
If the channel being edited has an assistant associated with it, the 
Formula Assistant dialog will appear. You can then select from the 
Formula Options shown.
If the channel has no assistant, you must click the Edit button next to 
the Formula text box to edit the formula. This will bring up the 
Formula Editor dialog – Definer/Creator users only.
Advanced tab
8. To switch between Fixed and Scientific notation when reporting the 
channel values, change the selection in the Notation combo-box.
9. The Effect of Increasing Extension combo-box sets the relationship 
between the crosshead/actuator channel and the current channel 
(*Option only available to Definer/Creator level users).
Note
This setting only applies if “Auto” has been selected as the 
crosshead or actuator rod direction for a “GoTo” test segment. It 
determines which direction, crosshead up/actuator rod retract or 
crosshead down/actuator rod extend, that the crosshead or actuator 
rod must move in order to complete the test segment.
10. The Advanced tab also contains the following settings for the channel:
Calculate During Test
A check mark inside this box indicates that the channel data will be 
calculated while a test is being performed.
Recalculate Post-Test
A check mark inside this box indicates that the channel will be recalculated 
immediately after each test has been completed. A formula with this option 
selected will be calculated at the end of the test regardless of its When 
setting.
Never Recalculate
A check mark inside this box indicates that the variable will only be 
calculated once and cannot be recalculated.
Hidden
A check mark inside this box indicates that the variable will be hidden from 
view on the Test and Review pages.
Locked
A checkmark inside this box indicates that the variable will be locked. The 
variable can only be deleted by a user with the Definer/Creator privilege 
level.
Allow Formula Editor
A check mark inside this box indicates that the Formula Assistant for the 
channel or formula that you are editing will have an Edit button available. 
The Edit button gives you access to the Formula Editor. 
Find and replace text in pdf file - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
search text in pdf using java; text searchable pdf file
Find and replace text in pdf file - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
can't select text in pdf file; searching pdf files for text
Using TestWorks 4
Channels
Editing Configuration Items
82
Adding a hardware
channel
A hardware channel is inserted into a test method by:
1. Right-click within the Channels table view and select Add Hardware 
Channel. A menu of available hardware channels will appear. Select the 
desired channel within the Insert Hardware Channel option dialog and 
click OK. This will insert the channel into the method.
2. Refer to the above instructions on editing the channel.
Adding a software
channel
Note
Only Definer/Creator Level Users can add software channels.
1. Right-click within the Channels table view and select Add Software 
Channel. Select Add Software Channel. The Insert New Variable dialog 
will appear.
2. Type the Internal Name of the new variable into the Internal Name text 
box. The Internal Name is the name that is used by TestWorks 4 to 
identify channels. It cannot contain spaces. Although each TestWorks 4 
channel must have an internal name, a channel can also have a display 
name that contains spaces.
3. Specify what the new formula will be Added To. Select either the 
Sample or Specimen option.
Sample
Makes the formula contain one value for an entire 
sample. Each specimen in the sample will have the same 
value for the formula.
Specimen  Makes the formula contain one value for each specimen. 
Each specimen will have a unique value for the formula.
4. Refer to the above instructions on editing the channel.
Note
Adding a software channel will require the knowledge of formula 
writing. This manual does not cover formula writing. Please contact 
the MTS HelpLine for further information.
Deleting a channel
Note
Only Definer/Creator Level Users can delete hardware channels.
1. By accessing the Edit Channel dialog, highlight the channel you wish to 
delete. Right-click and select Delete. This will remove the channel from 
the method.
VB.NET PDF replace text library: replace text in PDF content in vb
and ASP.NET webpage. Find and replace text in PDF file in preview without adobe PDF reader component installed. Able to pull text
how to select text in pdf; how to select text on pdf
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
project along with sample codes, which you can find in the Demos folder under RasterEdge.Imaging.Demo directory with the file name RasterEdge.Imaging.Demo.PDF.
find and replace text in pdf; how to search pdf files for text
Formulas
Using TestWorks 4
Editing Configuration Items
83
Formulas
The Formula Configuration Item displays the formulas available to you for 
each specific method. To access the Edit Formula dialog:
2. Click on the menu option Method, highlight Edit Method, highlight 
Configuration Items, and select Formulas (by highlighting).
The following components of the Formula table appear when the Formula 
configuration item has been selected:
Note
You can sort a table based on any column in the table. To sort the 
table, click on the heading for the column you want to sort by. Click 
on the heading a second time to sort in the opposite direction. For 
example, to sort the table by display name, click on the Display 
Name column.
VB.NET PDF File & Page Process Library SDK for vb.net, ASP.NET
find detailed guidance on creating, loading, merge and splitting PDF pages and Files, adding a page into PDF document, deleting unnecessary page from PDF file
select text pdf file; pdf text search
VB.NET Create PDF Library SDK to convert PDF from other file
Create writable PDF file from text (.txt) file in VB with a demo project, which you can find in the programming, you can use specific APIs to create PDF file.
make pdf text searchable; converting pdf to searchable text format
Using TestWorks 4
Formulas
Editing Configuration Items
84
Display Name
This column lists all of the formulas by their display name.
Units
This column displays the units of the variables.
Report Order
This column within the table displays the order in which the variable will be 
reported in relation to the other variables of the same type.
Formula Option
The Formula Option displays the type of formula being used to calculate the 
result formula. For some formulas, TestWorks 4 will allow you to alter the 
formula by selecting from the different options.
Formula Options are provided in TestWorks 4 to help the user define the 
formula option of a formula without having to manually configure a formula.
Status
There are two possible entries in the Formula table status column:
Calculated
The formula is enabled and will be calculated.
Not Calculated  The formula is disabled and will therefore 
NOT be calculated.
The Formula Configuration Item contains the settings for all formulas 
available within the test method. The Formula Settings dialog is a tabled 
dialog located beneath the Formula Table window. This dialog allows you to 
define formula characteristics, such as display name, units, and the manner 
in which TestWorks 4 will handle the results.
Note
The type of changes you can make to the formula are based on your 
user privilege level.
Follow these steps to define your formula characteristics:
General tab
1. Place a check mark in the Calculated box to activate the formula.
2. Type a display name in the Display Name text box. 
3. Click on the Units combo-box to select the type of unit to be used by 
the formula. 
Note
If you need Units that do not appear, click on the “Unit Class” 
button to select a different Unit Class. Be careful not to use the 
incorrect Unit Class. This will result in inaccurate results.
4. Click on the Decimal Places combo-box to select the number of 
decimal places that the formula result will display.
C# PDF File Permission Library: add, remove, update PDF file
Text: Replace Text in PDF. Image: Insert Image to PDF. Image: Remove read PDF, VB.NET convert PDF to text, VB.NET the following code table, you will find a piece
search pdf for text in multiple files; text searchable pdf
VB.NET PDF File Permission Library: add, remove, update PDF file
Text to PDF. Text: Delete Text from PDF. Text: Replace Text in PDF. NET rotate PDF pages, C#.NET search text in PDF In the following code table, you will find a VB
pdf text searchable; pdf find text
Formulas
Using TestWorks 4
Editing Configuration Items
85
5. Place a check mark in the Result checkbox if you want this formula to 
be displayed as a result on the Review Page and on your Reports and 
your Export files. Click the Result Order button to bring the Result 
Order dialog (this will set the order in which the results are seen).
Description tab
6. Type a description in the Description text box.
Formula tab
7. To view or edit the formula, click on the Formula tab.
If the formula being edited has an assistant associated with it, the 
Formula Assistant dialog will appear. You can then select from the 
Formula Options shown. If the formula has no assistant, you must click 
the Edit button next to the Formula text box to edit the formula.
Advanced tab
8. The Advanced tab allows the set up of advanced properties in the 
formula, such as:
A. Click on the Category combo-box to select a category. A category 
allows you to organize formulas for easier accessibility.
B. Click on the When combo-box to select when the formula will be 
calculated.
C. Click on the Notation combo-box to select the format in which 
your data will appear. You can select either Fixed or Scientific 
notations.
D. Enter a default value in the Default Value text box. (In most cases, 
the default value of the formula is irrelevant). The default value is 
used when the formula has not yet been calculated. It is also used 
when the Reset to Default option has been selected. 
E. Place a check mark in the Recalculate Post-Test box if you want 
the formula to calculate itself after the test is completed.
F. Place a check mark in the Never Recalculate box if you do NOT 
want the formula to calculate itself when the user chooses the 
“Recalculate Sample” or “Recalculate Specimen” menu item.
G. Place a check mark in the Sample Level if this formula should be 
stored at the sample level (i.e. all specimens will have the same 
formula value).
H. Place a check mark in the Reset to the Default Values box if you 
want this formula to reset to its default values before each test is 
run.
C# HTML5 PDF Viewer SDK deployment on Visual Studio .NET
C#.NET rotate PDF pages, C#.NET search text in PDF, C# Unzip the download package and you can find a project Once done debugging with x86 dlls, replace the x86
pdf find and replace text; cannot select text in pdf file
VB.NET PDF - Deploy VB.NET HTML5 PDF Viewer on Visual Studio.NET
C#.NET rotate PDF pages, C#.NET search text in PDF, C# Unzip the download package and you can find a project Once done debugging with x86 dlls, replace the x86
how to search text in pdf document; pdf editor with search and replace text
Using TestWorks 4
Formulas
Editing Configuration Items
86
I. Place a check mark in the Hidden box if you want to make sure 
this formula does not appear on any TestWorks 4 user screens or 
report printouts.
J. Place a check mark in the Locked box if you want to make sure 
this formula will not be deleted.
K. Place a check mark in the Allow Formula Editor box if you want 
the Edit button on the Formula tab to be enabled for users with 
Definer privileges.
9. If the unit class of the formula is an Integer, a Marker tab will be 
available.
A. Place a check mark in the Marker box if you want a marker to 
appear on the Review Graph at the index value calculated by the 
formula.
B. Place a check mark in the Movable Marker box if you want the 
marker to be movable by the user. If the marker is moved on the 
review graph, the formula will be updated to reflect the new value.
C. In the Symbol text box, type the test that will be used as the marker 
symbol.
Inserting a formula
A formula can be inserted into a test method by the following:
1. Access the Edit Formula dialog screen by clicking on the Method menu 
option, highlighting Edit Method, selecting Configuration Items, and 
highlighting Formulas.
2. Place the cursor within the Formula table section and right-click. This 
displays a menu dialog. Highlight either Add Formula (to add a result 
calculation) or Add Marker Formula (to add a marker to the review 
graph).
3. Once selected, the Formula Builder will be displayed. Refer to“Formula 
Builder - (Creating Formulas)” on page 111, for instructions.
Deleting a formula
A formula can be deleted from a method by the following:
1. Highlight the formula, within the Formula table, to be deleted by 
clicking on it.
2. Right-click and select Delete. This will erase the formula from the 
method.
Inputs
Using TestWorks 4
Editing Configuration Items
87
Inputs
The Input Configuration Item displays the inputs available to you for each 
specific method. To access the Edit Input dialog:
1. Click on the menu option Method, highlight Edit Method, highlight 
Configuration Items, and select Inputs (by highlighting this option).
The following components of the Input Table appear when the Input 
Configuration Item has been selected:
Note
You can sort a table based on any column in the table. To sort the 
table, click on the heading for the column you want to sort by. Click 
on the heading a second time to sort in the opposite direction. For 
example, to sort the table by display name, click on the Display 
Name column.
Using TestWorks 4
Inputs
Editing Configuration Items
88
Display Name
This column lists all of the variables by their display name(s).
Default Value
This column lists the default values for each input within the Inputs table. 
The default value is the initial value and can be changed by the user or in the 
test flow.
Units
This column displays the default units of the variables.
The Input Settings dialog is a tabbed dialog located beneath the Input Table 
window. This dialog allows you to define input characteristics such as 
display name, units, and default value
Note
The type of changes you can make to the input are based on your 
user privilege level.
Follow these steps to define your input characteristics:
General tab
1. Type a display name into the Display Name text box. 
2. Click on the Units combo-box to select the type of units. If you need a 
unit that does not appear, select the Unit Class button to change the unit 
class.
Note
If you need Units that do not appear, click on the “Unit Class” 
button to select a different Unit Class. Be careful not to use 
incorrect Unit Class. This will result in inaccurate results.
3. Type a default value in the Default Value text box.
4. Click on the Decimal Places combo-box to indicate the number of 
decimal places to be used by the input.
5. Place a check mark in the Result checkbox if you want this input to be 
displayed as a result on the Review page and on your Reports and in 
your Export files. Click the Result Order button to bring the Result 
Order dialog.
Description tab
6. Type a description into the Description text box.
Limits tab
7. Click on the Limits tab to enter minimum and maximum values for the 
input. Place a check mark in the Minimum box and enter the minimum 
value for the input into the text box to specify a minimum value. Place a 
check mark in the Maximum box and enter the maximum value for the 
input into the text box to specify a maximum value for the input. Limits 
will allow you to lock in a range, reducing the chance of entering 
incorrect values.
Inputs
Using TestWorks 4
Editing Configuration Items
89
Options tab
8. The Options tab allows the setting of the following options:
Input Required
A check mark inside this box indicates that a value will be requested for 
this input during the test. The input will be requested by the Required 
Inputs test segment that is in the test section specified by the input’s 
WHEN setting.
For example, if the WHEN setting of an input is Pre-Specimen, the input 
value will be requested by the Required Inputs test segment inside the Pre-
Specimen test section.
Panel Input
A check mark inside this box indicates that the input will be listed 
within the Input panel of the Test page. This makes the input easy to 
view and edit.
Display Only
A check mark inside this box indicates that the input will only be 
displayed when it appears on the Test page or the Review page. You 
will not be able to edit or change the value of the input from these 
locations.
To edit a Display Only input, you must edit it from the Define page or the 
Edit Method menu option.
Editable Post-Test
A check mark inside this box indicates that you can edit the input after a 
specimen has been tested. 
Reset to Default Values
A check mark inside this box indicates that the formula or input will be 
automatically reset to its default value for the next test.
Hidden
A check mark inside this box indicates that the variable will be hidden 
from view on the Test and Review pages.
Choice List
A check mark inside this box indicates that a list of default values is 
available for the input. When you enter a value for the input, you can 
select from this list of values through the Choice List combo-box.
To modify the choice list of an input, click on the Edit button that appears 
beside the input's default value.
Only Allow Choices
A check mark inside this box indicates that you can only select a value 
from the choice list of the input. You cannot enter a unique value.
Using TestWorks 4
Inputs
Editing Configuration Items
90
Advanced tab
9. Click on the When combo-box to select when the input will be 
requested.
10. Select an item in the Category combo-box to change the input’s 
category.
11. Click on the Notation combo-box to select the notation of the input. 
Select either Fixed or Scientific.
12. Set the following options as desired:
Locked 
A check mark inside this box indicates that the 
variable will be locked. A user will need 
sufficient privileges to delete the input. 
Sample-Level  A check mark inside this box indicates that 
the formula or input will be a sample-level 
formula or input and will have the same 
value for every specimen in the sample.
13. If you have System Channels enabled on your system, you will have a 
Source tab on the Input Settings dialog. On this tab, you can click on 
the Source combo-box to select the source of the input value. Keyboard 
Only is the typical setting.
In the Statistics combo-box, select the statistic that will be applied 
to the incoming values.
In the Number of Readings box, type the number of readings that 
are expected.
Documents you may be interested
Documents you may be interested