how to upload pdf file in c# windows application : Convert pdf to searchable text online Library software class asp.net winforms .net ajax plecsmanual14-part659

Thermal Editor
Adding Custom Variables
Custom variables, such as gate resistance or stray inductance, that you wish
to use in the definition of device losses may be defined on the Variables tab.
Use the Add
,Remove
,Up
and Down
buttons on the left to add or
remove custom variables or to reorder them. Note that the first three lines
in the list are reserved for the intrinsic variables and may not be removed or
reordered.
When you add a custom variable, you may specify a Prompt, which should
provide a brief description of the purpose variable, and a Variable, which
must be a unique identifier. This identifier may then be used in the formula
expressions that define the device losses.
In the Min and Max columns you may enter minimum and maximum al-
lowed values for both intrinsic and custom variables. During a simulation,
PLECS will monitor the actual values of the variables and raise a diagnostic
message if a variable value exceeds a specified limit. The default action is to
show an error and stop the simulation but this may be changed in the simu-
lation parameters dialog using the diagnostic parameter Loss variable limit
exceeded (see “PLECS Blockset Parameters” on page 93 and “PLECS Stan-
dalone Parameters” on page 97).
119
Convert pdf to searchable text online - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
how to select text in pdf image; pdf editor with search and replace text
Convert pdf to searchable text online - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
pdf make text searchable; how to search text in pdf document
4
Thermal Modeling
Specifying custom variable values
When you select a thermal description with custom variables on the Thermal
tab of a semiconductor parameter dialog, the dialog will show additional pa-
rameter fields for the custom variables using the prompts mentioned above.
An example dialog is shown below.
Instead of static values that remain constant during a simulation you may
also specify the label of a Signal Goto block (see page 510) for a custom vari-
able. The label is a string consisting of a prefix for the scope (
g:
for global,
s:
for schematic and
m:
for masked subsystem) and the tag name of the Goto
block. For example, if your model contains a Goto block with global scope and
the tag name
Rg
,you would enter
’g:Rg’
(including the quotation marks) in
order to reference this signal in a custom variable of a thermal description.
This can be used e.g. to simulate the effect of a gate drive that can dynami-
cally change the effective gate resistance.
Adding Custom Lookup Tables
Custom lookup tables are defined on the Custom tables tab. To add a new ta-
ble, click on New... and specify a unique name and the number of dimensions
of the new table. Use the Duplicate..., Rename... and Remove buttons to
duplicate, rename or remove an existing custom table.
120
Online Convert PDF to Text file. Best free online PDF txt
convert PDF document to editable & searchable text file text converter control toolkit can convert PDF document to Download and try RasterEdge.XDoc.PDF for .NET
text select tool pdf; search pdf files for text
C# PDF Convert to Text SDK: Convert PDF to txt files in C#.net
PDF document conversion SDK provides reliable and effective .NET solution for Visual C# developers to convert PDF document to editable & searchable text file.
pdf select text; pdf text search tool
Thermal Editor
Custom tables can be used in function expressions for device losses using the
lookup
function, which is called with a string specifying custom table name
and one to three numeric arguments depending on the number of dimensions
of the table.
For example, consider that you have defined a custom variable
Rg
for the gate
resistance and a custom table
Gate Resistance Eon Scaler
that describes
how the turn-on losses scale in terms of the gate resistance. You could then
use the Lookup table and formula method on the Turn-on loss tab, spec-
ify the nominal losses in the turn-on-loss lookup table and enter the following
function expression:
E*lookup('Gate Resistance Eon Scaler', Rg)
Editing Lookup Tables
When editing an intrinsic lookup table on one of the three loss tabs or a cus-
tom lookup table, you can add and remove new interpolation points for a ta-
ble dimension with the Edit menu or the context menu in the table. To enter
multiple values at once, separate them by semicolons or spaces.
To rotate and tilt a three-dimensional table view, click on an empty space with
the left mouse button and drag the mouse while keeping the mouse button
pressed.
Lookup method
When calculating function values from a lookup table, PLECS uses linear in-
terpolation if an input value lies within the index range for the corresponding
table dimension. If the input value lies outside the index range, PLECS will
extrapolate using the first or last pair of index values.
Copy, Paste and Scaling
Thermal data can be copied and pasted within the tables of the thermal edi-
tor, and to or from other programs, like e.g. Microsoft Excel. This can be done
using the context menu or by pressing Ctrl-C/Ctrl-V (or cmd-C/cmd-V on
Mac OS X). To specify the target location for the data, you have to select a
part of the table that has the same number of rows and columns as the copied
121
VB.NET PDF Convert to Text SDK: Convert PDF to txt files in vb.net
& searchable text formats. Support .NET WinForms, ASP.NET MVC in IIS, ASP.NET Ajax, Azure cloud service, DNN (DotNetNuke), SharePoint. Convert PDF document page
find text in pdf image; select text in pdf reader
VB.NET Image: Robust OCR Recognition SDK for VB.NET, .NET Image
more companies are trying to convert printed business on artificial intelligence to extract text from documents will be outputted as searchable PDF, PDF/A,TXT
find text in pdf files; convert pdf to searchable text online
4
Thermal Modeling
data. When copying from another program, only the first correctly format-
ted number in each table cell will be copied, any additional information (e.g.
units) will be discarded.
Values selected in a table can be scaled by a given factor by right-clicking and
choosing Scale selected values... from the context menu. To convert a value
from 0.23 J to 0.23 mJ, e.g., you can scale it with a factor of 0.001. To only
change the unit but not the actual value, i.e. to change 0.23 J to 230 mJ, use
the Energy scale drop box at the top right.
122
C# Create PDF Library SDK to convert PDF from other file formats
PDF document file created by RasterEdge C# PDF document creator library is searchable and can be fully populated with editable text and graphics
search pdf for text in multiple files; pdf text searchable
VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.
Why do we need to convert PDF document to HTML webpage One is that compared with HTML file, PDF file (a not be easily edited), is less searchable for search
pdf text search; how to search a pdf document for text
Semiconductor Loss Specification
Semiconductor Loss Specification
Care must be taken to ensure the polarity of the currents and voltages are
correct when specifying conduction and switching loss data for semiconductor
switches and diodes. If one or both polarities are in the wrong direction, the
losses will be zero or incorrect. The voltage and current polarities of a single
semiconductor switch, diode and semiconductor switch with diode are defined
in PLECS as shown in the figure below.
Voltage and current polarity of single semiconductor switch, diode and semi-
conductor switch with diode
Single Semiconductor Switch Losses
The blocking voltage experienced by a single semiconductor switch is positive;
therefore, switching losses are defined in the positive voltage/positive current
region. Conduction losses are also defined in the positive voltage/positive cur-
rent region.
Diode Losses
The voltage and current waveforms during a typical diode switching cycle are
shown in the next figure. Turn on losses occur at t = t
1
and turn off losses at
t= t
2
.The switching energy loss in both cases is calculated by PLECS using
the negative blocking voltage and positive conducting current at the switching
instant. These values are shown in the figure as dots. Therefore, the lookup
tables for the turn-on and turn-off switching losses must be specified in the
negative voltage/positive current region.
Conduction losses occur when t
1
<t < t
2
.During this time period, the current
and voltage are both positive. Therefore the conduction loss profile must be
specified in the positive voltage/positive current region.
123
VB.NET PDF Convert to Word SDK: Convert PDF to Word library in vb.
Word documents from both scanned PDF and searchable PDF files without Convert PDF document to DOC and DOCX formats in to export Word from multiple PDF files in
convert a scanned pdf to searchable text; search a pdf file for text
C# PDF: C# Code to Draw Text and Graphics on PDF Document
This online guide content is Out Dated! Draw and write searchable text on PDF file by C# code in both Web and Windows applications.
search pdf files for text programmatically; how to make pdf text searchable
4
Thermal Modeling
I
diode
V
diode
t
1
t
2
t
Diode voltage and current during switching
Losses of Semiconductor Switch with Diode
Semiconductor switches with an integrated diode such as the IGBT with Diode
model allow losses for both the semiconductor switch and diode to be individ-
ually specified using a single set of lookup tables. The conduction and switch-
ing loss tables for the semiconductor switch are specified for the same volt-
age/current regions as for the single semiconductor switch without diode. Due
to the polarity reversal of the diode, the diode losses are appended to the loss
tables of the semiconductor switch by extending the tables in the negative
voltage/negative current direction for the diode conduction losses, and in the
positive voltage/negative current direction for the diode switching losses. An
example turn-off loss table and conduction loss profile for a semiconductor
switch with diode are shown in the next two figures. A summary of the valid
voltage and current regions for defining conduction and switching losses for
the different types of semiconductors is given below:
Switch with Diode
Diode
Switch
Switch
Diode
V
I
V
I
V
I
V
I
Conduction Loss
+
+
+
+
+
+
-
-
Switching Loss
-
+
+
+
+
+
+
-
124
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit Word
C# users can convert Convert Microsoft Office Word to searchable PDF online, create multi to add annotations to Word, such as add text annotations to
how to make a pdf file text searchable; convert pdf to word searchable text
C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net
library also makes PDF document visible and searchable on the Internet by converting PDF document file to Use C#.NET Demo Code to Convert PDF Document to
cannot select text in pdf; how to select text in a pdf
Semiconductor Loss Specification
Turn-off loss lookup table for semiconductor switch with diode
Conduction loss profile for semiconductor switch with diode
125
4
Thermal Modeling
126
5
Magnetic Modeling
Inductors and transformers are key components in modern power electronic
circuits. Compared to other passive components they are rather difficult to
model for the following reasons:
• Magnetic components, especially transformers with multiple windings can
have complex geometric structures. The flux in the magnetic core may be
split into several paths with different magnetic properties. In addition to
the core flux, each winding has its own leakage flux.
• Core materials such as iron alloy and ferrite express a highly non-linear
behavior. At high flux densities, the core material saturates leading to a
greatly reduced inductor impedance. Moreover, hysteresis effects and eddy
currents cause frequency-depending losses.
In PLECS, the user can build complex magnetic components in a special mag-
netic circuit domain. Primitives such as windings, cores and air gaps are pro-
vided in the Magnetics Library. The available core models include saturation
and hysteresis. Frequency dependent losses can be modeled with magnetic
resistances. Windings form the interface between the electrical and the mag-
netic domain.
Alternatively, less complex magnetic components such as saturable inductors
and single-phase transformers can be modeled directly in the electrical do-
main.
Equivalent circuits for magnetic components
To model complex magnetic structures with equivalent circuits, three different
approaches exist: Coupled-inductors, the resistance-reluctance analogy and
the capacitance-permeance analogy.
5
Magnetic Modeling
Coupled inductors
In the coupled inductor approach, the magnetic component is modeled directly
in the electrical domain as an equivalent circuit, in which inductances repre-
sent magnetic flux paths and losses incur at resistors. Magnetic coupling be-
tween windings is realized either with mutual inductances or with ideal trans-
formers.
Using coupled inductors, magnetic components can be implemented in any cir-
cuit simulator since only electrical components are required. This approach is
most commonly used for representing standard magnetic components such as
transformers. The figure below shows an example for a two-winding trans-
former, where L
1
and L
2
represent the leakage inductances, L
m
the non-
linear magnetization inductance and R
fe
the iron losses. The copper resis-
tances of the windings are modeled with R
1
and R
2
.
Lσ1
Rfe
Lσ2
R2
Lm
R1
Ideal Transformer
N1:N2
Transformer implementation with coupled inductors
However, the equivalent circuit bears little resemblance to the physical struc-
ture of the magnetic component. For example, parallel flux paths in the mag-
netic structure are modeled with series inductances in the equivalent circuit.
For non-trivial magnetic components such as multiple-winding transformers
or integrated magnetic components, the equivalent circuit can be difficult to
derive and understand. In addition, equivalent circuits based on inductors are
impossible to derive for non-planar magnetic components.
Reluctance-resistance analogy
The traditional approach to model magnetic structures with equivalent elec-
trical circuits is the reluctance-resistance analogy. The magnetomotive force
(MMF) F is regarded as analogous to voltage and the magnetic flux  as anal-
ogous to current. As a consequence, magnetic reluctance of the flux path R
corresponds to electrical resistance: