Meter (3-Phase)
Meter (3-Phase)
Purpose
Measure voltages and currents of 3-phase system
Library
Electrical / Meters
Description
The meter block acts as a set of volt- and ammeters. Voltages can be mea-
sured from line to ground (V
a
,V
b
and V
c
)or from line to line (V
ab
,V
bc
,V
ca
)de-
pending on the Voltage measurement parameter. The output for voltage and
current is a vectorized signal with three elements.
Parameter
Voltage measurement
Determine whether the voltages are measured from line to ground or from
line to line.
Probe Signals
Measured voltage
The measured voltages as a vector with three elements.
Measured current
The measured currents as a vector with three elements.
429
Pdf find text - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
search text in pdf using java; pdf make text searchable
Pdf find text - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
searching pdf files for text; search a pdf file for text
13
Component Reference
Minimum / Maximum
Purpose
Output input signal with highest resp. lowest value
Library
Control / Math
Description
The Minimum / Maximum block compares its input signals against each other.
If the Operation parameter is set to
Minimum
,the output will be set to the
value of the input signal with the lowest value. If the Operation parameter
is set to
Maximum
,the output will be set to the value of the input signal with
the highest value.
In case of a single input, all elements of the input vector are compared. Vec-
torized input signals of the same width are compared element wise and result
in a vectorized output signal. If vectorized and scalar input signals are mixed,
the scalar input signals are expanded to the width of the vectorized input sig-
nals.
Parameters
Operation
Selects between
Minimum
and
Maximum
as described above.
Number of inputs
The number of inputs.
Probe Signals
Input i
The ith input signal.
Output
The block output signal.
430
C# Word - Search and Find Text in Word
C# Word - Search and Find Text in Word. Learn How to Search Text in PDF Document and Obtain Text Content and Location Information. Overview.
convert a scanned pdf to searchable text; select text in pdf
C# PowerPoint - Search and Find Text in PowerPoint
C# PowerPoint - Search and Find Text in PowerPoint. Learn How to Search Text in PDF Document and Obtain Text Content and Location Information. Overview.
how to select all text in pdf; converting pdf to searchable text format
MMF Meter
MMF Meter
Purpose
Output the measured magneto-motive force
Library
Magnetic
Description
The MMF Meter measures the magneto-motive force between its two mag-
netic terminals and provides it as a signal at the output of the component.
Apositive MMF is measured when the magnetic potential at the terminal
marked with a “+” is greater than at the unmarked one. The output signal
can be made accessible in Simulink with an Output block (see page 514) or by
dragging the component into the dialog box of a Probe block.
Note The MMF Meter is ideal, i.e. it has an zero internal permeance. Hence,
if multiple meters are connected in series the MMF across an individual meter
is undefined. This produces a run-time error.
Probe Signal
MMF
The measured magneto-motive force in ampere-turns (A).
431
C# Excel - Search and Find Text in Excel
Easy to search and find text content and get its location details. Allow to search defined Excel file page or the whole document. C# PDF: Example of Finding Text
search pdf files for text; how to make a pdf file text searchable
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
When you have downloaded the RasterEdge Image SDK for .NET, you can unzip the package to find the RasterEdge.Imaging.PDF.dll in the bin folder under the root
pdf text select tool; pdf find highlighted text
13
Component Reference
MMF Source (Constant)
Purpose
Generate a constant magneto-motive force
Library
Magnetic
Description
The Constant MMF Source generates a constant magneto-motive force (MMF)
between its two magnetic terminals. The MMF is considered positive at the
terminal marked with a “+”.
Note An MMF source may not be short-circuited or connected in parallel to a
permeance or any other MMF source.
Parameter
Voltage
The magnitude of the MMF, in ampere-turns (A). The default value is
1
.
Probe Signal
MMF
The magneto-motive force of the source, in ampere-turns (A).
432
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit Excel
HTML5 Viewer for C# .NET, users can convert Excel to PDF document, export C#.NET RasterEdge HTML5 Viewer also enable users to quickly find text content by
how to search pdf files for text; search pdf documents for text
VB.NET PDF File & Page Process Library SDK for vb.net, ASP.NET
document. If you find certain page in your PDF document is unnecessary, you may want to delete this page directly. Moreover, when
convert pdf to word searchable text; how to select all text in pdf
MMF Source (Controlled)
MMF Source (Controlled)
Purpose
Generate a variable magneto-motive force
Library
Magnetic
Description
The Controlled MMF Source generates a variable magneto-motive force
(MMF) between its two terminals. The MMF is considered positive at the ter-
minal marked with a “+”. The momentary MMF is determined by the signal
fed into the input of the component.
Note An MMF source may not be short-circuited or connected in parallel to a
permeance or any other MMF source.
Parameter
Allow state-space inlining
For expert use only! When set to
on
and the input signal is a linear com-
bination of magnetic measurements, PLECS will eliminate the input vari-
able from the state-space equations and substitute it with the correspond-
ing output variables. The default is
off
.
Probe Signal
MMF
The magneto-motive force of the source, in ampere-turns (A).
433
C# WPF Viewer: Load, View, Convert, Annotate and Edit Excel
function will help users to freely convert Excel document to PDF, Tiff and Text search and select functionalities and manipulate help to find text contents on
text searchable pdf; search pdf files for text programmatically
XDoc.Word for .NET, Support Processing Word document and Page in .
Able to view and edit Word rapidly. Convert. Convert Word to PDF. Convert Word to ODT. Text & Image Process. Search and find text in Word. Insert image to Word page
how to select text in pdf image; cannot select text in pdf file
13
Component Reference
Monoflop
Purpose
Generate pulse of specified width when triggered
Library
Control / Logical
Description
The output of the monoflop changes to 1 when the trigger condition is ful-
filled. When the trigger condition is no longer fulfilled the output stays 1 for
the given duration and changes to 0 afterwards.
Depending on the trigger type the behavior is as follows:
rising
The output is set to 1 for the given duration when the input changes from
0to a positive value.
falling
The output is set to 1 for the given duration when the input changes from
apositive value to 0.
level
The output is set to 1 when the input is a positive value. It stays 1 for the
given duration after the input returns to 0.
The monoflop is resettable, i.e. if the trigger condition is fulfilled again while
the output is 1 a new pulse is started.
Parameters
Trigger type
The trigger type as described above.
Pulse duration
The duration for which the output is set to 1.
Probe Signals
Input
The input signal.
Output
The output signal.
434
MOSFET
MOSFET
Purpose
Ideal MOSFET with optional on-resistance
Library
Electrical / Power Semiconductors
Description
The Metal Oxide Semiconductor Field Effect Transistor is a semiconductor
switch that is controlled via the external gate. It conducts a current from
drain to source (or vice-versa) only if the gate signal is not zero.
Parameters
The following parameters may either be scalars or vectors corresponding to
the implicit width of the component:
On-resistance
The resistance R
on
of the conducting device, in ohms ( ). The default is
0
.
Initial conductivity
Initial conduction state of the MOSFET. The MOSFET is initially blocking
if the parameter evaluates to zero, otherwise it is conducting.
Thermal description
Switching losses, conduction losses and thermal equivalent circuit of the
component. For more information see chapter “Thermal Modeling” (on
page 103). If no thermal description is given the losses are calculated
based on the voltage drop v
on
=R
on
i.
Initial temperature
Temperature of all thermal capacitors in the equivalent Cauer network at
simulation start.
Probe Signals
MOSFET voltage
The voltage measured between drain and source.
MOSFET current
The current through the MOSFET flowing from drain to source.
MOSFET gate signal
The gate input signal of the MOSFET.
MOSFET conductivity
Conduction state of the internal switch. The signal outputs 0 when the
MOSFET is blocking, and 1 when it is conducting.
435
13
Component Reference
MOSFET junction temperature
Temperature of the first thermal capacitor in the equivalent Cauer net-
work.
MOSFET conduction loss
Continuous thermal conduction losses in watts (W). Only defined if the
component is placed on a heat sink.
MOSET switching loss
Instantaneous thermal switching losses in joules (J). Only defined if the
component is placed on a heat sink.
436
MOSFET Converter (3ph)
MOSFET Converter (3ph)
Purpose
3-phase MOSFET converter
Library
Electrical / Converters
Description
Implements a three-phase two-level MOSFET converter with reverse diodes.
The gate input is a vector of three signals – one per leg. The upper MOSFET,
connected to the positive dc level, is on if the corresponding gate signal is posi-
tive. The lower MOSFET is on if the gate signal is negative. If the gate signal
is zero both MOSFETs in the leg are switched off.
You can choose between two different converter models:
• The basic MOSFET Converter is modeled using the component MOSFET
with Diode (see page 438). PLECS needs only six internal switches to simu-
late this converter. Only the on-resistances of the MOSFETs can be entered.
• The MOSFET Converter with Parasitics is based on individual MOSFET
(see page 435) and Diode (see page 311) components. In this model you may
specify forward voltages and on-resistances separately for the MOSFETs
and diodes.
Note Due to the switching conditions of the MOSFET with Diode (see page
438), this device cannot be turned off actively while the current is exactly zero.
This may resultinunexpected voltage waveformsif the converter is not loaded.
To resolve thisproblem, either use the MOSFET Converter with Parasitics,
or allow a small non-zero load current to flow by connectinga large load resis-
tance to the converter.
Parameters
For a description of the parameters see the documentation of the MOSFET
with Diode (on page 438), the MOSFET (on page 435) and the Diode (on page
311).
Probe Signals
The two-level MOSFET converters provide six or twelve probe signals, each a
vector containing the appropriate quantities of the individual devices: voltage,
current, conductivity, conduction loss and switching loss. The vector elements
are ordered top-to-bottom, left-to-right: a+, a-, b+, b-, c+, c-.
437
13
Component Reference
MOSFET with Diode
Purpose
Ideal MOSFET with ideal anti-parallel diode
Library
Electrical / Power Semiconductors
Description
This model of a Metal Oxide Semiconductor Field Effect Transistor has an in-
tegrated anti-parallel diode. The diode is usually included in power MOSFET
packages.
This device is modeled as a single ideal switch that closes when the gate sig-
nal is not zero or the voltage becomes negative and opens when the gate sig-
nal is zero and the current becomes positive.
Note Due to the switching conditions described above, this device cannot be
turned off actively while the current is exactly zero. This mayresult in unex-
pected voltage waveforms if the device isused e.g. in an unloaded converter.
To resolve thisproblem, either use an individual MOSFET (see page 435) with
an individual anti-parallel Diode (see page 311), or allow a small non-zero load
current to flow by connecting a large load resistance to the converter.
Parameters
Initial conductivity
Initial conduction state of the device. The device is initially blocking if the
parameter evaluates to zero, otherwise it is conducting. This parameter
may either be a scalar or a vector corresponding to the implicit width of
the component. The default value is
0
.
Thermal description
Switching losses, conduction losses and thermal equivalent circuit of the
component. For more information see chapters “Thermal Modeling” (on
page 103) and “Losses of Semiconductor Switch with Diode” (on page 124).
Initial temperature
Temperature of all thermal capacitors in the equivalent Cauer network at
simulation start. This parameter may either be a scalar or a vector corre-
sponding to the implicit width of the component.
Probe Signals
Device voltage
The voltage measured between drain and source. The device voltage can
never be negative.
438