MOSFETwith Diode
Device current
The current through the device. The current is positive if it flows through
the MOSFET from drain to source and negative if it flows through the
diode from source to drain.
Device gate signal
The gate input signal of the device.
Device conductivity
Conduction state of the internal switch. The signal outputs 0 when the
device is blocking, and 1 when it is conducting.
Device junction temperature
Temperature of the first thermal capacitor in the equivalent Cauer net-
work.
Device conduction loss
Continuous thermal conduction losses in watts (W). Only defined if the
component is placed on a heat sink.
Device switching loss
Instantaneous thermal switching losses in joules (J). Only defined if the
component is placed on a heat sink.
439
Pdf text searchable - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
convert pdf to searchable text online; how to make a pdf document text searchable
Pdf text searchable - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
pdf select text; searching pdf files for text
13
Component Reference
MOSFET with Limited di/dt
Purpose
Dynamic MOSFET model with finite current slopes during turn-on and turn-
off
Library
Electrical / Power Semiconductors
Description
In contrast to the ideal MOSFET model (see page 435) that switches instan-
taneously, this model includes drain current transients during switching.
Thanks to the continuous current decay during turn-off, stray inductances
may be connected in series with the device.
This MOSFET model is used to simulate overvoltages produced by parasitic
inductances and the reverse recovery effect of diodes. Due to simplified voltage
and current transient waveforms, the model is not suited for the simulation
of switching losses. The dynamic behavior of this MOSFET model is identical
with the one of the IGBT with limited di/dt (see page 379).
Note
• Due to the small time-constants introduced by the turn-onand turn-off tran-
sients a stiff solver isrecommended for thisdevice model.
• If multiple MOSFETs are connected inseries the off-resistance may not be
infinite.
Parameters
Blocking voltage
Maximum voltage V
DSS
in volts (V) that under any conditions should be
applied between drain and source.
Continuous drain current
Maximum dc current I
D
in amperes (A) that the MOSFET can conduct.
On-resistance
The resistance R
on
of the conducting device, in ohms ( ). The default is
0
.
Off-resistance
The resistance R
o
of the blocking device, in ohms ( ). The default is
1e6
.
This parameter may be set to
inf
unless multiple MOSFETs are con-
nected in series.
440
C# PDF Convert to Text SDK: Convert PDF to txt files in C#.net
NET project. Powerful .NET control for batch converting PDF to editable & searchable text formats in C# class. Free evaluation library
how to select text on pdf; find text in pdf image
C# Create PDF Library SDK to convert PDF from other file formats
The PDF document file created by RasterEdge C# PDF document creator library is searchable and can be fully populated with editable text and graphics
how to select text in pdf; can't select text in pdf file
MOSFETwith Limited di/dt
Rise time
Time t
r
in seconds between instants when the drain current has risen from
10 % to 90 % of the continuous drain current I
D
.
Fall time
Time t
f
in seconds between instants when the drain current has dropped
from 90 % to 10 % of its initial value along an extrapolated straight line
tangent the maximum rate-of-change of the current.
Fall time
Time t
f
in seconds between instants when the drain current has dropped
from 90 % to 10 % of its initial value along an extrapolated straight line
tangent the maximum rate-of-change of the current decay.
Stray inductance
Internal inductance L
in henries (H) measured between the drain and
source terminals.
Initial current
The initial current through the component at simulation start, in amperes
(A). The default is
0
.
Probe Signals
MOSFET voltage
The voltage measured between drain and source.
MOSFET current
The current through the MOSFET flowing from drain to source.
MOSFET conductivity
Conduction state of the internal switch. The signal outputs 0 when the
MOSFET is blocking, and 1 when it is conducting.
441
VB.NET Image: Robust OCR Recognition SDK for VB.NET, .NET Image
for VB.NET provides users fast and accurate image recognition function, which converts scanned images into searchable text formats, such as PDF, PDF/A, WORD
select text in pdf; pdf make text searchable
VB.NET PDF Convert to Text SDK: Convert PDF to txt files in vb.net
keeping original layout. VB.NET control for batch converting PDF to editable & searchable text formats. Support .NET WinForms, ASP
select text in pdf file; pdf text search
13
Component Reference
Moving Average
Purpose
Continuously average input signal over specified time period
Library
Control / Filters
Description
The Moving Average filter averages a continuous input signal u over the spec-
ified averaging time T. The output y is continuously updated in every simula-
tion step:
y(t) =
1
T
t
t T
u()d
The implementation of this block avoids accumulating numerical integration
errors typically associated with continuous-time implementations of FIR fil-
ters. However, the Moving Average filter is computationally more expensive
and less accurate than the similar Periodic Average (see page 454).
Parameters
Averaging time
The length of the averaging period in sec.
Initial buffer size
Size of the internal ring buffer at simulation start. The buffer size will be
increased during the simulation if required.
Probe Signals
Input
The input signal.
Output
The filtered output signal.
442
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit Word
C# users can convert Convert Microsoft Office Word to searchable PDF online, create multi empowered to add annotations to Word, such as add text annotations to
how to search a pdf document for text; make pdf text searchable
Online Convert PDF to Text file. Best free online PDF txt
PDF document conversion SDK provides reliable and effective .NET solution for Visual C# developers to convert PDF document to editable & searchable text file.
pdf search and replace text; pdf searchable text
Mutual Inductor
Mutual Inductor
Purpose
Ideal mutual inductor
Library
Electrical / Passive Components
Description
This component provides two or more coupled inductors. Electrically, it is
equivalent with a vectorized Inductor (see page 403). In contrast to the vec-
torized Inductor, this component displays the individual inductors in the
schematic as separate windings.
In the symbol of the mutual inductor, the positive terminal of winding 1 is
marked with a little circle. The positive terminals of all other windings are
marked with dots.
Note An inductor may not be connected in series with a current source. Doing
so would create a dependency between an input variable (the source current)
and a state variable (the inductor current) in the underlyingstate-space equa-
tions.
Parameters
Number of windings
The number of ideal inductors represented by the component.
Inductance
The inductance in henries (H). All finite positive and negative values are
accepted, including
0
.
If the parameter is a scalar or a vector no coupling exists between the
windings. In order to model a magnetic coupling between the windings a
square matrix must be entered. The size n of the matrix corresponds to
the number of windings. L
i
is the self inductance of the internal inductor
and M
i;j
the mutual inductance:
2
6
6
6
6
6
6
4
v
1
v
2
.
.
.
v
n
3
7
7
7
7
7
7
5
=
2
6
6
6
6
6
6
4
L
1
M
1;2
 M
1;n
M
2;1
L
2
 M
2;n
.
.
.
.
.
.
.
.
.
.
.
.
M
n;1
M
n;2
 L
n
3
7
7
7
7
7
7
5
2
6
6
6
6
6
6
4
d
dt
i
1
d
dt
i
2
.
.
.
d
dt
i
n
3
7
7
7
7
7
7
5
443
VB.NET Create PDF from Text to convert txt files to PDF in vb.net
Best VB.NET adobe text to PDF converter library for Visual Studio .NET project. Batch convert editable & searchable PDF document from TXT formats in VB.NET
search pdf for text in multiple files; search pdf for text
C# Create PDF from Text to convert txt files to PDF in C#.net, ASP
Visual Studio .NET project. .NET control for batch converting text formats to editable & searchable PDF document. Free .NET library for
convert pdf to searchable text; pdf find text
13
Component Reference
The inductance matrix must be invertible, i.e. it may not be singular. A
singular inductance matrix results for example when two or more induc-
tors are ideally coupled. To model this, use an inductor in parallel with an
Ideal Transformer (see page 359).
The relationship between the coupling factor k
i;j
and the mutual induc-
tance M
i;j
is
M
i;j
=M
j;i
=k
i;j
p
L
i
L
j
Initial current
The initial current in the windings at simulation start, in amperes (A).
This parameter may either be a scalar or a vector corresponding to the
number of windings. The direction of the initial current inside the com-
ponent is from the positive to the negative terminal. The default of the
initial current is
0
.
Probe Signals
Winding i current
The current flowing through winding i, in amperes (A).
Winding i voltage
The voltage measured across winding i, in volts (V).
444
VB.NET Create PDF from Word Library to convert docx, doc to PDF in
Export all Word text and image content into high quality Professional .NET PDF batch conversion control. Easy to create searchable and scanned PDF files from
find and replace text in pdf file; how to make pdf text searchable
VB.NET Create PDF from PowerPoint Library to convert pptx, ppt to
PDF, VB.NET convert PDF to text, VB.NET multiple pages PowerPoint to fillable and editable PDF documents. Easy to create searchable and scanned PDF files from
cannot select text in pdf; select text in pdf reader
Mutual Inductance (2 Windings)
Mutual Inductance (2 Windings)
Purpose
Magnetic coupling between two lossy windings
Library
Electrical / Transformers
Description
This component implements a magnetic coupling between two separate wind-
ings. For both windings the self inductance and resistance are specified in-
dividually. The mutual inductance and resistance are modeled as linear ele-
ments.
The electrical circuit for this component is given below:
1:1
i
2
i
1
R
m
L
m
L
1
−Lm
R
1
−R
m
L
2
−L
m
R
2
−R
m
In the symbol of the mutual inductance, the positive terminal of the primary
winding is marked with a little circle. The positive terminal of the secondary
winding is marked with a dot.
Parameters
Self inductance
Atwo-element vector containing the self inductance for the primary wind-
ing L
1
and the secondary winding L
2
.The inductivity is given in henries
(H).
Winding resistance
Atwo-element vector containing the self resistance of the primary winding
R
1
and the secondary winding R
2
,in ohms ( ).
Mutual inductance
The mutual inductance L
m
,in henries (H).
Mutual resistance
The mutual resistance R
m
,in ohms ( ).
Initial current
Atwo-element vector containing the initial currents on the primary side
i
1
and the secondary side i
2
,in amperes (A). The direction of the initial
445
13
Component Reference
current inside the component is from the positive to the negative terminal.
The default value is
[0 0]
.
Probe Signals
Winding i current
The current flowing through winding i, in amperes (A).
Winding i voltage
The voltage measured across winding i, in volts (V).
446
Mutual Inductance (3 Windings)
Mutual Inductance (3 Windings)
Purpose
Magnetic coupling between three lossy windings
Library
Electrical / Transformers
Description
This component implements a magnetic coupling between three separate
windings. For all windings the self inductance and resistance are specified in-
dividually. The mutual inductance and resistance are modeled as linear ele-
ments.
The electrical circuit for this component is given below:
R
3
−R
m
i
1
R
m
L
m
L
1
−Lm
R
1
−R
m
1:1:1
i
3
L
3
−L
m
i
2
L
2
−L
m
R
2
−R
m
In the symbol of the mutual inductance, the positive terminal of the primary
winding is marked with a little circle. The positive terminals of the secondary
and tertiary windings are marked with dots.
Parameters
Self inductance
Athree-element vector containing the self inductance for the primary
winding L
1
,the secondary winding L
2
and the tertiary winding L
3
.The
inductivity is given in henries (H).
Winding resistance
Athree-element vector containing the self resistance of the primary wind-
ing R
1
,the secondary winding R
2
and the tertiary winding R
3
,in ohms
( ).
Mutual inductance
The mutual inductance L
m
,in henries (H).
Mutual resistance
The mutual resistance R
m
,in ohms ( ).
447
13
Component Reference
Initial current
Athree-element vector containing the initial currents on the primary side
i
1
,the secondary side i
2
and the tertiary side i
3
,in amperes (A). The direc-
tion of the initial current inside the component is from the positive to the
negative terminal. The default value is
[0 0 0]
.
Probe Signals
Winding i current
The current flowing through winding i, in amperes (A).
Winding i voltage
The voltage measured across winding i, in volts (V).
448
Documents you may be interested
Documents you may be interested