how to upload pdf file in c# windows application : Find and replace text in pdf control Library platform web page .net azure web browser plecsmanual53-part702

Signal From
Signal From
Purpose
Reference signal from Signal Goto block by name
Library
System
Description
The Signal From block references another signal from a Signal Goto block. All
Signal From blocks connect to the Signal Goto block with the same tag within
the given scope. If no matching Signal Goto block is found an error message
will be displayed when starting a simulation.
The parameter dialog of the Signal From block provides a link to the corre-
sponding Signal Goto block. Note that the link is not updated until you click
the Apply button after changing the tag name or scope.
Parameters
Tag name:
The tag names of the Signal From and Signal Goto blocks must match to
establish a connection.
Scope:
The scope specifies the search depth for the matching Signal Goto block.
Using the value Global the complete PLECS circuit is searched. When
set to Schematic only the schematic containing the Signal From block
is searched. The setting Masked Subsystem causes a lookup within the
hierarchy of the masked subsystem in which the block is contained. If the
block is not contained in a masked subsystem a global lookup is done.
509
Find and replace text in pdf - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
pdf find and replace text; pdf find highlighted text
Find and replace text in pdf - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
how to select all text in pdf file; how to select text on pdf
13
Component Reference
Signal Goto
Purpose
Make signal available by name
Library
System
Description
The Signal Goto block forwards its input signal to a number of Signal From
blocks within the same scope. All Signal From blocks connect to the Signal
Goto block with the same tag within the given scope. It is not allowed to have
multiple Signal From blocks with the same tag name within the same scope.
The parameter dialog of the Signal Goto block provides a list of links to the
corresponding blocks, i.e. all Signal From blocks with a matching tag name
and scope. Note that the list is not updated until you click the Apply button
after changing the tag name or scope.
Parameters
Tag name:
The tag names of the Signal From and Signal Goto blocks must match to
establish a connection.
Scope:
The scope specifies the search depth for the matching Signal From blocks.
Using the value Global the complete PLECS circuit is searched. When
set to Schematic only the schematic containing the Signal From block
is searched. The setting Masked Subsystem causes a lookup within the
hierarchy of the masked subsystem in which the block is contained. If the
block is not contained in a masked subsystem a global lookup is done.
510
VB.NET PDF replace text library: replace text in PDF content in vb
and ASP.NET webpage. Find and replace text in PDF file in preview without adobe PDF reader component installed. Able to pull text
how to search a pdf document for text; how to make a pdf document text searchable
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
When you have downloaded the RasterEdge Image SDK for .NET, you can unzip the package to find the RasterEdge.Imaging.PDF.dll in the bin folder under the root
search pdf files for text; pdf select text
Signal Inport
Signal Inport
Purpose
Add signal input connector to subsystem
Library
System
Description
1
Inports are used to feed signals from a schematic into a subschematic. In the
PLECS Blockset, inports are also used to feed signals from a Simulink model
into a PLECS circuit. If you copy an input block into a schematic an input ter-
minal will be created on the corresponding subsystem block. The name of the
input block will appear as the terminal label. If you choose to hide the block
name by unselecting the show button in the dialog box the terminal label will
also disappear.
Input Blocks in a Top-Level Circuit
If an input block is placed in a top-level schematic a unique input port number
is assigned to the block. In the PLECS Blockset, this port number determines
the position of the corresponding input terminal of the PLECS Circuit block in
the Simulink model.
For top-level inputs in the PLECS Blockset you can also specify whether the
input signal is used as a continuous signal in order to control e.g. sources or
as a discrete gate signal in order to feed control the gate of a switch or semi-
conductor. Continuous signal inputs have direct feedthrough which can lead to
algebraic loops if there is a direct path from a circuit output to a (continuous)
circuit input. In contrast, gate signal inputs do not have direct feedthrough.
However, they are expected to change only at discrete instants. Using a gate
signal input to feed a continuous signal into a Circuit block can lead to un-
expected results. The standard setting
auto
causes PLECS to determine the
signal type based on the internal connectivity.
Input Blocks in a Subsystem
If placed in a subschematic the inputs are not identified by numbers since ter-
minals on subsystem blocks can be freely positioned. Which terminal corre-
sponds to which input block can only be seen from the block name. In order to
move a terminal with the mouse around the edges of a subsystem block hold
down the Shift key while dragging the terminal with the left mouse button or
use the middle mouse button.
511
VB.NET PDF File & Page Process Library SDK for vb.net, ASP.NET
document. If you find certain page in your PDF document is unnecessary, you may want to delete this page directly. Moreover, when
select text in pdf reader; make pdf text searchable
VB.NET Create PDF Library SDK to convert PDF from other file
Create writable PDF file from text (.txt) file in VB.NET To get this RasterEdge PDF document file creator library the RasterEdge .NET Image SDK and find the PDF
convert a scanned pdf to searchable text; search pdf for text
13
Component Reference
Parameters
Width
The width of the input signal. The default
auto
means that the width is
inherited from connected blocks.
Signal type
The input signal type (see the description above). This parameter appears
only in the PLECS Blockset if the block is placed in a top-level schematic.
Port number
The terminal number of the input block. This parameter appears only in
the PLECS Blockset if the block is placed in a top-level schematic.
512
C# HTML5 PDF Viewer SDK deployment on Visual Studio .NET
C#.NET rotate PDF pages, C#.NET search text in PDF, C# Unzip the download package and you can find a project Once done debugging with x86 dlls, replace the x86
cannot select text in pdf; search text in pdf using java
VB.NET PDF - Deploy VB.NET HTML5 PDF Viewer on Visual Studio.NET
C#.NET rotate PDF pages, C#.NET search text in PDF, C# Unzip the download package and you can find a project Once done debugging with x86 dlls, replace the x86
convert pdf to searchable text online; how to search pdf files for text
Signal Multiplexer
Signal Multiplexer
Purpose
Combine several signals into vectorized signal
Library
System
Description
This multiplexer combines several signals into a vectorized signal. The input
signals may be scalars or vectors. In the block icon, the first input is marked
with a dot.
Parameter
Number of inputs
This parameter allows you to specify the number and width of the input
signals. You can choose between the following formats for this parameter:
Scalar: A scalar specifies the number of scalar inputs to the block. If this
format is used the block accepts only signals with a width of 1.
Vector: The length of the vector determines the number of inputs. Each
element specifies the width of the corresponding input signal.
513
C# PDF File Permission Library: add, remove, update PDF file
Text: Replace Text in PDF. Image: Insert Image to PDF. Image: Remove read PDF, VB.NET convert PDF to text, VB.NET the following code table, you will find a piece
select text pdf file; pdf text search tool
VB.NET PDF File Permission Library: add, remove, update PDF file
Text to PDF. Text: Delete Text from PDF. Text: Replace Text in PDF. NET rotate PDF pages, C#.NET search text in PDF In the following code table, you will find a VB
search text in pdf image; pdf text select tool
13
Component Reference
Signal Outport
Purpose
Add signal output connector to subsystem
Library
System
Description
1
Outports are used to feed signals from subschematic to the parent schematic.
In the PLECS Blockset, outports are also used to feed signals from a PLECS
circuit back to Simulink. If you copy an output block into a schematic an out-
put terminal will be created on the corresponding subsystem block. The name
of the output block will appear as the terminal label. If you choose to hide
the block name by unselecting the show button in the dialog box the terminal
name will also disappear.
Output Blocks in a Top-Level Circuit
If an output block is placed in a top-level circuit a unique output port number
is assigned to the block. In the PLECS Blockset, this port number determines
the position of the corresponding output terminal of the PLECS Circuit block
in the Simulink model.
Output Blocks in a Subsystem
If placed in a subschematic the outputs are not identified by numbers since
terminals on subsystem blocks can be freely positioned. Which terminal cor-
responds to which output block can only be seen from the block name. In or-
der to move a terminal with the mouse around the edges of a subsystem hold
down the Shift key while dragging the terminal with the left mouse button or
use the middle mouse button.
Parameters
Width
The width of the output signal. The default
auto
means that the width is
inherited from connected blocks.
Port number
The terminal number of the output block. This parameter appears only if
the block is placed in a top-level circuit.
514
Signal Selector
Signal Selector
Purpose
Select or reorder elements from vectorized signal
Library
System
Description
The Signal Selector block generates an output vector signal that consists of
the specified elements of the input vector signal.
Parameters
Input width
The width of the input signal vector.
Output indices
Avector with the indices of the input elements that the output vector
should contain.
515
13
Component Reference
Signal Switch
Purpose
Select one of two input signals depending on control signal
Library
Control / Discontinuous
Description
While the Signal Switch is in the off-state the output is connected to the in-
put terminal indicated in the icon. When the switch criteria is met, the switch
changes to the on-state and the output is connected to the opposite input ter-
minal.
Parameters
Criteria
The switch criteria which has to be met to put the switch in the on-state.
Available choices are
u >= Threshold
,
u > Threshold
and
u = Threshold
.
Threshold
The threshold value used for the switch criteria.
Probe Signals
Inputs
The block input signals.
Output
The block output signal.
Switch position
The state of the switch. The output is
0
while the switch is in the off-state
and
1
while it is in the on-state.
516
Signum
Signum
Purpose
Provide sign of input signal
Library
Control / Math
Description
The Signum block outputs
1
for positive,
-1
for negative and
0
for
0
input val-
ues.
Probe Signals
Input
The block input signal.
Output
The block output signal.
517
13
Component Reference
Sine Wave
Purpose
Generate time-based sine wave with optional bias
Library
Control / Sources
Description
The Sine Wave block generates a sinusoidal output signal with an optional
bias according to the equation
y= A sin(! t +’)+ C
!= 2f
If a variable-step solver is used, the solver step size is automatically limited to
ensure that a smooth waveform is produced.
Parameters
Amplitude
The amplitude A of the sine wave signal.
Bias
The offset C that is added to the sine wave signal.
Frequency
The frequency of the sine wave in hertz (f) or rad/second (!), see below.
Phase
The phase ’ of the sine wave in rad, per unit (p.u.) or degrees, see below.
The parameter value should be in the range
[0 2]
,
[0 1]
or
[0 360]
re-
spectively.
Units for frequency and phase
The frequency and phase can be expressed in terms of
(rad/sec, rad)
,
(Hz, p.u.)
or
(Hz, degrees)
.If the phase is expressed in per unit (p.u.),
avalue of
1
is equivalent to the period length.
Probe Signal
Output
The block output signal.
518
Documents you may be interested
Documents you may be interested