how to upload pdf file in c# windows application : Find text in pdf image Library software API .net winforms html sharepoint plecsmanual56-part705

Switched Reluctance Machine
The total torque T
e
of the machine is given by the sum of the individual phase
torques.
Mechanical System
Rotor speed:
d
dt
!=
1
J
(T
e
F!  T
m
)
Rotor angle:
d
dt
= !
Parameters
Stator resistance
Stator resistance R in ohms ( ).
Unaligned stator inductance
Stator inductance L
u
in the unaligned rotor position, in henries (H).
Initial aligned stator inductance
Initial stator inductance L
a
in the aligned rotor position, in henries (H).
Saturated aligned stator inductance
Saturated stator inductance L
sat
in the aligned rotor position, in henries
(H).
Aligned saturation flux linkage
Flux linkage  
sat
at which the stator saturates in the aligned position, in
Vs.
Inertia
Combined rotor and load inertia J in Nms
2
.
Friction coefficient
Viscous friction F in Nms.
Initial rotor speed
Initial mechanical speed !
m;0
in radians per second (s
1
).
Initial rotor angle
Initial mechanical rotor angle 
m;0
in radians.
Initial stator currents
Athree-element vector containing the initial stator currents i
a;0
,i
b;0
and
i
c;0
of phases a, b and c in amperes (A).
539
Find text in pdf image - search text inside PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn how to search text in PDF document and obtain text content and location information
pdf find and replace text; pdf text search tool
Find text in pdf image - VB.NET PDF Text Search Library: search text inside PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Learn How to Search Text in PDF Document and Obtain Text Content and Location Information in VB.NET application
how to select all text in pdf file; cannot select text in pdf
13
Component Reference
Probe Signals
Stator phase currents
The three-phase stator winding currents i
a
,i
b
and i
c
,in A. Currents flow-
ing into the machine are considered positive.
Back EMF
The back EMF voltages e
a
,e
b
,e
c
in volts (V).
Stator flux linkage
The flux linkages in the individual phases of the machine in Vs.
Rotational speed
The rotational speed !
m
of the rotor in radians per second (s
1
).
Rotor position
The mechanical rotor angle 
m
in radians.
Electrical torque
The electrical torque T
e
of the machine in Nm.
References
D.A. Torrey, J.A. Lang, “Modelling a nonlinear variable-reluctance motor
drive”, IEE Proceedings, Vol. 137, Pt. B, No. 5, Sept. 1990.
D.A. Torrey, X.-M. Niu, E.J. Unkauf, “Analytical modelling of variable-
reluctance machine magnetisation characteristic”, IEE Proceedings Elec-
tric Power Applications, Vol. 142, No. 1, Jan. 1995.
540
C# Word - Search and Find Text in Word
C# Word - Search and Find Text in Word. Learn How to Search Text in PDF Document and Obtain Text Content and Location Information. Overview.
how to select text in pdf and copy; find and replace text in pdf
C# PowerPoint - Search and Find Text in PowerPoint
C# PowerPoint - Search and Find Text in PowerPoint. Learn How to Search Text in PDF Document and Obtain Text Content and Location Information. Overview.
how to select text in pdf image; how to search text in pdf document
Symmetrical PWM
Symmetrical PWM
Purpose
Generate PWM signal using symmetrical triangular carrier
Library
Control / Modulators
Description
2-level PWM generator with a symmetrical triangular carrier. The input m is
the modulation index, and the output s is the switching function. If the mod-
ulation index is a vector the switching function is also a vector of the same
width.
The block can be used to control the IGBT Converter (see page 370) or the
ideal Converter (see page 358). In these cases the modulation index must have
awidth of 3 according to the number of inverter legs.
The block offers different sampling methods for the modulation index. The fig-
ure below illustrates Natural Sampling.
−1
0
1
Switching function
−1
0
1
Natural Sampling
Modulation index
1/f
The following figures illustrate the different Regular Sampling methods. In
the figure on the left, double edge sampling is used, i.e. the modulation in-
dex is updated at both tips of the triangular carrier. In the right figure, single
541
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
When you have downloaded the RasterEdge Image SDK for .NET, you can unzip the package to find the RasterEdge.Imaging.PDF.dll in the bin folder under the root
select text in pdf file; how to search pdf files for text
VB.NET PDF File & Page Process Library SDK for vb.net, ASP.NET
document page modifying page, you will find detailed guidance is the programmatic representation of a PDF document newly created blank pages or image-only pages
text searchable pdf file; how to search a pdf document for text
13
Component Reference
edge sampling is employed. Here, the modulation index is updated only at the
upper tips of the carrier.
−1
0
1
Switching function
−1
0
1
Double edge sampling
Modulation index
1/f
Single edge sampling
1/f
Parameters
Sampling
Select a sampling method. If you select Natural Sampling the carrier
signal may begin with 0 or 1 at simulation start. The Regular Sampling
method lets you choose between double edge or single edge sampling.
Carrier frequency
The frequency f of the triangular carrier signal, in Hz.
Carrier offset
The time offset of the carrier signal, in p.u. of the carrier period.
Input limits
The range of the modulation index. The default is
[-1 1]
.
Output values
Values of the switching function in off-state and on-state. The default is
[-1 1]
.
542
VB.NET Image: How to Draw Annotation on Doc Images with Image SDK
like multi-page TIFF, Microsoft Office Word and PDF file). and also font style / size for the text annotation to the user manuals listed below, or find more on
select text in pdf; pdf searchable text converter
C# WPF Viewer: Load, View, Convert, Annotate and Edit Excel
functionalities and manipulate help to find text contents on Convert Microsoft Office Excel to PDF (.pdf). Microsoft Office Excel to Tiff image (.tif, .tiff
how to select all text in pdf; how to make pdf text searchable
Symmetrical PWM(3-Level)
Symmetrical PWM (3-Level)
Purpose
Generate 3-level PWM signal using symmetrical triangular carriers
Library
Control / Modulators
Description
3-level PWM generator with two symmetrical triangular carriers. The input m
is the modulation index. The switching function s outputs either 1, 0 or -1. If
the modulation index is a vector the switching function is also a vector of the
same width.
The block can be used to control the 3-Level IGBT Converter (see page 363)
or the ideal 3-Level Converter (see page 357). In these cases the modulation
index must have a width of 3 according to the number of inverter legs.
The figures below illustrate the Natural Sampling method. In the left figure,
the negative carrier signal is obtained by flipping the positive carrier verti-
cally around the time axis. In the right figure, the positive carrier is verti-
cally shifted to construct the negative carrier. The latter technique reduces
the switching frequency and hence the semiconductor stress in three-phase
converters.
−1
0
1
Switching function
−1
0
1
Modulation index
Negative carrier flipped
1/f
Negative carrier shifted
1/f
543
XDoc.Word for .NET, Support Processing Word document and Page in .
Convert. Convert Word to PDF. Convert Word to ODT. Process Word table, row and cell. Text & Image Process. Search and find text in Word. Insert image to Word page
search multiple pdf files for text; how to select text on pdf
C# Raster - Raster Conversion & Rendering in C#.NET
Image Conversion. |. Home ›› XImage.Raster ›› C# Raster: Comversion. How to Convert Raster Image to or from Various Document and Image formats.
how to make a pdf file text searchable; convert pdf to searchable text
13
Component Reference
The figures below illustrate the different Regular Sampling methods offered
by this block. With double edge sampling (left figure) the modulation index
is updated at the carrier tips and zero-crossings. With single edge sampling
(right figure) the modulation index is updated only at the outer tips.
−1
0
1
Switching function
−1
0
1
Double edge sampling
Modulation index
1/f
Single edge sampling
1/f
Parameters
Sampling
Select a sampling method. If you select Natural Sampling the carrier
signal may begin with 0 or 1 at simulation start. The Regular Sampling
method lets you choose between double edge and single edge sampling.
Carrier frequency
The frequency f of the triangular carrier signals, in Hz.
Carrier offset
The time offset of the carrier signal, in p.u. of the carrier period.
Negative carrier
Select the phase shift between the negative and positive carrier signals.
The negative carrier may be constructed from the positive carrier either by
flipping or shifting.
Input limits
The range of the modulation index. The default is
[-1 1]
.
544
Synchronous Machine (Round Rotor)
Synchronous Machine (Round Rotor)
Purpose
Smooth air-gap synchronous machine with main-flux saturation
Library
Electrical / Machines
Description
This synchronous machine has one damper winding on the direct axis and two
damper windings on the quadrature axis of the rotor. Main flux saturation is
modeled by means of a continuous function.
The machine operates as a motor or generator; if the mechanical torque has
the same sign as the rotational speed the machine is operating in motor
mode, otherwise in generator mode. All electrical variables and parameters
are viewed from the stator side. In the component icon, phase a of the stator
winding and the positive pole of the field winding are marked with a dot.
In order to inspect the implementation, please select the component in your
circuit and choose Look under mask from the Subsystem submenu of the
Edit menu. If you want to make changes, you must first choose Break li-
brary link and then Unprotect, both from the same menu.
Electrical System
Stator flux linkages:
 
d
=L
ls
i
d
+L
m;d
i
d
+i
0
f
+i
0
k;d
 
q
=L
ls
i
q
+L
m;q
i
q
+i
0
g
+i
0
k;q
The machine model offers two different implementations of the electrical sys-
tem: a traditional rotor reference frame and a voltage-behind-reactance formu-
lation.
Rotor Reference Frame Using Park’s transformation, the 3-phase circuit
equations in physical variables are transformed to the dq rotor reference
frame. This results in constant coefficients in the stator and rotor equations
making the model numerically efficient. However, interfacing the dq model
with the external 3-phase network may be difficult. Since the coordinate
transformations are based on voltage-controlled current sources, inductors and
naturally commutated devices such as diode rectifiers may not be directly con-
nected to the stator terminals. In these cases, fictitious RC snubbers are re-
quired to create the necessary voltages across the terminals.
545
13
Component Reference
R
s
L
ls
L
m,d
p∙ω
m
∙Ψ
q
+
v
d
+
v'
f
i
d
L'lf
R'f
i'f
L'lk,d
R'k,d
i'k,d
d-axis
R
s
L
ls
L
m,q
p∙ω
m
∙Ψ
q
+
v
q
i
q
L'lk,q2
R'k,q2
i'k,q2
L'lk,q1
R'k,q1 i'k,q1
q-axis
Voltage behind Reactance This formulation allows for direct interfacing of
arbitrary external networks with the 3-phase stator terminals. The rotor dy-
namics are expressed using explicit state-variable equations while the stator
branch equations are described in circuit form. However, due to the resulting
time-varying inductance matrices, this implementation is numerically less effi-
cient than the traditional rotor reference frame.
In both implementations, the value of the main flux inductance L
m
is not con-
stant but depends on the main flux linkage  
m
as illustrated in the  
m
=i
m
di-
agram. For flux linkages  
m
far below the transition flux  
T
,the relationship
between flux and current is almost linear and determined by the unsaturated
magnetizing inductance L
m;0
.For large flux linkages the relationship is gov-
erned by the saturated magnetizing inductance L
m;sat
T
defines the knee
of the transition between unsaturated and saturated main flux inductance.
The tightness of the transition is defined with the form factor f
T
.If you do not
have detailed information about the saturation characteristic of your machine,
f
T
=1 is a good starting value. The function
plsaturation(Lm0,Lmsat,PsiT,fT)
546
Synchronous Machine (Round Rotor)
plots the main flux vs. current curve and the magnetizing inductance vs. cur-
rent curve for the parameters specified.
∂Ψ/∂i = L
m,0
∂Ψ/∂i = L
m,sat
f
T
= 4
f
T
= 2
f
T
= 1
f
T
= 0.5
i
m
Ψ
m
Ψ
T
The model accounts for steady-state cross-saturation, i.e. the steady-state
magnetizing inductances along the d-axis and q-axis are functions of the cur-
rents in both axes. For rotating reference frame formulation, the stator cur-
rents, the field current and the main flux linkage are chosen as state vari-
ables. With this choice of state variables, the representation of dynamic cross-
saturation could be neglected without affecting the performance of the ma-
chine. The computation of the time derivative of the main flux inductance was
not required.
Electro-Mechanical System
Electromagnetic torque:
T
e
=
3
2
p(i
q
 
d
i
d
 
q
)
Mechanical System
Mechanical rotor speed !
m
:
!_
m
=
1
J
(T
e
F!
m
T
m
)
_
m
= !
m
547
13
Component Reference
Parameters
Most parameters for the Salient Pole Synchronous Machine (see page 550) are
also applicable to this round rotor machine. The following parameters are dif-
ferent:
Unsaturated magnetizing inductance
The unsaturated magnetizing inductance L
m;0
.The value in henries (H) is
referred to the stator side.
Saturated magnetizing inductance
The saturated magnetizing inductance L
m;sat
,in H. If no saturation is to
be modeled, set L
m;sat
=L
m;0
.
Damper resistance
Athree-element vector containing the damper winding resistance R
0
k;d
,
R
0
k;q1
and R
0
k;q2
of the d-axis and the q-axis. The values in ohms ( ) are
referred to the stator side.
Damper leakage inductance
Athree-element vector containing the damper winding leakage inductance
L
0
lk;d
,L
0
lk;q1
and L
0
lk;q2
of the d-axis and the q-axis. The values in henries
(H) are referred to the stator side.
Initial field/damper current
Atwo-element vector containing the initial currents i
f;0
in the field wind-
ing and i
0
k;q1;0
in one of the damper windings in amperes (A). The current
in the damper winding is referred to the stator side.
Probe Signals
Most probe signals for the Salient Pole Synchronous Machine (see page 550)
are also available with this machine. Only the following probe signal is differ-
ent:
Damper currents
The damper currents i
0
k;d
,i
0
k;q1
and i
0
k;q2
in the stationary reference frame
in A, referred to the stator side.
References
D. C. Aliprantis, O. Wasynczuk, C. D. Rodriguez Valdez, “A voltage-behind-
reactance synchronous machine model with saturation and arbitrary ro-
tor network representation”, IEEE Transactions on Energy Conversion,
Vol. 23, No. 2, June 2008.
K. A. Corzine, B. T. Kuhn, S. D. Sudhoff, H. J. Hegner, “An improved method
for incorporating magnetic saturation in the Q-D synchronous ma-
chine model”, IEEE Transactions on Energy Conversion, Vol. 13, No. 3,
Sept. 1998.
548
Documents you may be interested