load pdf in webbrowser control c# : Extract jpg from pdf Library software class asp.net windows azure ajax E82EV__8200%20vector%200.25-90kW__v3-0__EN34-part1608

Function library
Free interconnection of analog signals  
Free configuration of analog process data output words
10
341
EDS82EV903   EN   3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0421
*
(Cont.)
Possible analog signals for C0421
  338
26
Output frequency normalised without
slip (MCTRL1−NOUT−NORM)
214  C0011
27
Output frequency without slip
(MCTRL1−NOUT)
24000  480 Hz
28
Actual process controller value
(PCTRL1−ACT)
29
Process controller setpoint
(PCTRL1−SET1)
30
Process controller output without
feedforward control (PCTRL1−OUT)
31
Ramp function generator input
(NSET1−RFG1−IN)
32
Ramp function generator output
(NSET1−NOUT)
33 (A)
PID controller output
(PCTRL1−PID−OUT)
34 (A)
Process controller output
(PCTRL1−NOUT)
35
Input signal at X3/8 (standard I/O) or
X3/1U or X3/1I (application I/O),
assessed with gain (C0414/1 or C0027)
and offset (C0413/1 or C0026)
(AIN1−OUT)
1000  Maximum value of analog
input signal (5 V, 10 V, 20 mA, 10
kHz)
Condition: The gain of the analog
input or frequency input is set to:
C0414/x, C0426 = 20/C0011 [%]
36
Input signal at frequency input X3/E1,
assessed with gain (C0426) and offset
(C0427) (DFIN1−OUT)
37
Motor potentiometer output
(MPOT1−OUT)
38 (A)
Input signal at X3/2U or X3/2I,
assessed with gain (C0414/2) and
offset (C0413/2) (AIN2−OUT)
40
AIF input word 1 (AIF−IN.W1)
Setpoints to the controller from
communication module on AIF
Normalisation via AIF
41
AIF input word 2 (AIF−IN.W2)
50
CAN−IN1.W1 or FIF−IN.W1
Setpoints to controller from
function module on FIF
Normalisation via CAN or FIF
51
CAN−IN1.W2 or FIF−IN.W2
52
CAN−IN1.W3 or FIF−IN.W3
53
CAN−IN1.W4 or FIF−IN.W4
60
CAN−IN2.W1
61
CAN−IN2.W2
62
CAN−IN2.W3
63
CAN−IN2.W4
255
Not assigned (FIXED−FREE)
Signal linkage
The process data output words are linked with internal analog signals by entering the
selection figure of the internal signal in the corresponding subcode of C0421. C0421 can
be different for the parameter sets.
Extract jpg from pdf - Select, copy, paste PDF images in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support PDF Image Extraction from a Page, a Region on a Page, and PDF Document
extract color image from pdf in c#; extract image from pdf c#
Extract jpg from pdf - VB.NET PDF Image Extract Library: Select, copy, paste PDF images in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support PDF Image Extraction from a Page, a Region on a Page, and PDF Document
extract images pdf acrobat; extract image from pdf file
Function library
Free interconnection of analog signals  
Free configuration of analog process data output words
10
342
EDS82EV903  EN  3.0
Examples
ƒ
C0421/3   5: The monitoring signal Motor voltage" is the signal source for
CAN−OUT1/word1.
ƒ
C0421/8   61: The process data input wordCAN−IN2/word2 is the signal source for
CAN−OUT2/word 2.
Note!
ƒ
The process data output words CAN−OUT1.W1/FIF−OUT.W1, CAN−OUT2.W1
and FIF−OUT.W2 can also be assigned to C0417 and C0418 with 16 bit status
information each:
–With digital configuration under C0417 or C0418 no simultaneous analog
assignment with C0421 (C0421/x = 255)!
–With analog configuration under C0421 no simultaneous digital
assignment with C0417 and C0418 (C0417/x = 255, C0418/x = 255)!
–Otherwise the output signal would be incorrect.
ƒ
The process data input words CAN−IN1.W1/FIF−IN.W1,
CAN−IN1.W2/FIF−IN.W2, CAN−IN2.W1 and CAN−IN2.W2 can be defined as
analog word or digital word (16 bit). If you link them with analog process
data output words (C0421/x = 50, 51 or 60, 61), they must be defined as
analog input words. Otherwise the output signal would be incorrect.
C# PDF Convert to Jpeg SDK: Convert PDF to JPEG images in C#.net
NET library to batch convert PDF files to jpg image files. High Turn multiple pages PDF into single jpg files respectively online. Support
extract text from image pdf file; extract jpeg from pdf
VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.
PDF to images, C#.NET PDF file & pages edit, C#.NET PDF pages extract, copy, paste, C# NET components to batch convert adobe PDF files to jpg image files.
extract text from pdf image; extract jpg pdf
Function library
Free interconnection of digital signals
Free configuration of digital input signals
10
343
EDS82EV903   EN   3.0
10.12
Free interconnection of digital signals  
10.12.1
Free configuration of digital input signals 
Description
ƒ
Internal digital signals can be freely assigned to external digital signal sources. It is
thus possible to achieve a freely configured control of the controller
–Digital inputs X3/E1 ... X3/E6
–Digital process data input words
ƒ
A signal source can be assigned to several targets. Please ensure reasonable
assignments. Otherwise it is possible to activate functions which cannot be
operated together (e.g. a digital signal linked with quick stop and DC braking at the
same time).
Note!
Use C0007 to configure some internal digital signals with the digital inputs
X3/E1 ... X3/E4 block by block. The corresponding subcodes of C0410 will be
adapted automatically.
Note!
The default setting defines the signals for the most frequently used function
modules of the standard I/O and application I/O. If the default setting is
changed, all unused signals must be set to FIXED−FREE in order to ensure
trouble−free operation.
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze
Selection
C0410
Free
configuration
of digital input
signals
Linking of digital signal sources to internal
digital signals
A selection in C0007 is copied to
the corresponding subcode of
C0410. A change in C0410 sets
C0007 = 255!
  343
1
NSET1−JOG1/3
NSET1−JOG1/3
/5/7 (A)
1
Digital input X3/E1
Selection of fixed
setpoints
C0410/1
C0410/
2
C0410/33
LOW
LOW
LOW
HIGH LOW
LOW
LOW
HIGH LOW
...
...
...
HIGH HIGH HIGH
Active
C0046
JOG1
JOG2
...
JOG7
2
NSET1−JOG2/3
NSET1−JOG2/3
/6/7 (A)
2
Digital input X3/E2
3
DCTRL1−CW/
CCW
4
Digital input X3/E4
CW = clockwise
rotation
CCW =
counter−clockwise
rotation
LOW
HIGH
4
DCTRL1−QSP
255
Not assigned (FIXED−FREE)
Quick stop (via terminal
LOW−active)
5
NSET1−RFG1−
STOP
255
Not assigned (FIXED−FREE)
Stop main setpoint of ramp
function generator
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
String inputFilePath = @"C:\input.pdf"; String outputFilePath = @"C:\output.jpg"; // Convert PDF to jpg. C# sample code for PDF to jpg image conversion.
extract photos pdf; some pdf image extractor
C# Image Convert: How to Convert Tiff Image to Jpeg, Png, Bmp, &
RasterEdge.XDoc.PDF.dll. String inputFilePath = @"C:\input.tif"; String outputFilePath = @"C:\output.jpg"; // Convert tiff to jpg.
extract images from pdf c#; how to extract a picture from a pdf
Function library
Free interconnection of digital signals
Free configuration of digital input signals
10
344
EDS82EV903  EN  3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
6 NSET1−RFG1−0
255
Not assigned (FIXED−FREE)
Set ramp function generator input
for main setpoint to "0"
7
MPOT1−UP
255
Not assigned (FIXED−FREE)
Motor potentiometer functions
8
MPOT1−DOWN
255
Not assigned (FIXED−FREE)
9
Reserved
255
Not assigned (FIXED−FREE)
Do not change 255!
10
DCTRL1−CINH
255
Not assigned (FIXED−FREE)
Controller inhibit (via terminal
LOW−active)
11
DCTRL1−TRIP−
SET
255
Not assigned (FIXED−FREE)
External fault (via terminal
LOW−active)
12
DCTRL1−TRIP−
RESET
255
Not assigned (FIXED−FREE)
Reset fault
13
DCTRL1−PAR2/
4
255
Not assigned (FIXED−FREE)
Change over parameter set
(only possible if C0988 = 0)
C0410/13 and C0410/14 must
have the same source in all used
parameter sets. Otherwise
changeover between parameter
sets is not possible (error message
CE5 or CE7).
14
DCTRL1−PAR3/
4
255
Not assigned (FIXED−FREE)
C0410/13
C0410/
14
LOW
LOW
HIGH
LOW
LOW
HIGH
HIGH
HIGH
Active
PAR1
PAR2
PAR3
PAR4
15
MCTRL1−DCB
3
Digital input X3/E3
DC injection brake
16
(A)
PCTRL1−RFG2−
LOADI
255
Not assigned (FIXED−FREE)
Connect actual process controller
value (PCTRL1−ACT) to process
controller ramp function
generator (PCTRL1−RFG2)
17
DCTRL1−H/Re
255
Not assigned (FIXED−FREE)
Manual/remote changeover
18
PCTRL1−OFF
255
Not assigned (FIXED−FREE)
Switch off I component of the
process controller
19
PCTRL1−OFF
255
Not assigned (FIXED−FREE)
Switch off process controller
20
Reserved
255
Not assigned (FIXED−FREE)
Do not change 255!
21
PCTRL1−STOP
255
Not assigned (FIXED−FREE)
Stop process controller ("freeze"
value)
22
DCTRL1−CW/
QSP
255
Not assigned (FIXED−FREE)
Fail−safe change of the direction
of rotation
23
DCTRL1−CCW/
QSP
255
Not assigned (FIXED−FREE)
24
DFIN1−ON
255
Not assigned (FIXED−FREE)
0 = frequency input inactive
1 = frequency input active 
Configure frequency input with
C0425 and C0426
C# Create PDF from images Library to convert Jpeg, png images to
Batch convert PDF documents from multiple image formats, including Jpg, Png, Bmp, Gif, Tiff, Bitmap, .NET Graphics, and REImage.
extract image from pdf using; extract image from pdf java
VB.NET PDF - Convert PDF with VB.NET WPF PDF Viewer
read PDF, VB.NET convert PDF to text, VB.NET extract PDF pages, VB PDF to image file formats with high quality, support converting PDF to PNG, JPG, BMP and
pdf image extractor c#; how to extract pictures from pdf files
Function library
Free interconnection of digital signals
Free configuration of digital input signals
10
345
EDS82EV903   EN   3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0410
(Cont.)
  343
25
(A)
PCTRL1−FOLL1−
0
255
Not assigned (FIXED−FREE)
Run follow−up controller to "0"
along reset ramp C0193
26
(A)
Reserved
255
Not assigned (FIXED−FREE)
27
(A)
NSET1−TI1/3
255
Not assigned (FIXED−FREE)
Connect acceleration times
28
(A)
NSET1−TI2/3
255
Not assigned (FIXED−FREE)
C0410/27
C0410/
28
LOW
LOW
HIGH
LOW
LOW
HIGH
HIGH
HIGH
Active
C0012;
C0013
T
ir
1; T
if
1
T
ir
2; T
if
2
T
ir
3; T
if
3
29
(A)
PCTRL1−
FADING
255
Not assigned (FIXED−FREE)
Fade−in (LOW)/fade−out (HIGH)
process controller output
30
(A)
PCTRL1−INV−
ON
255
Not assigned (FIXED−FREE)
Invert process controller output
31
(A)
PCTRL1−NADD−
OFF
255
Not assigned (FIXED−FREE)
Switch off additonal setpoint
32
(A)
PCTRL1−RFG2−0
255
Not assigned (FIXED−FREE)
Ramp function generator input −
run process controller to "0" along
ramp C0226
33
(A)
NSET1−JOG4/5
/6/7
255
Not assigned (FIXED−FREE)
C# WPF PDF Viewer SDK to convert and export PDF document to other
C#.NET PDF file & pages edit, C#.NET PDF pages extract, copy, paste PDF to image file formats with high quality, support converting PDF to PNG, JPG, BMP and
extract image from pdf; extract image from pdf in
VB.NET Create PDF from images Library to convert Jpeg, png images
Support create PDF from multiple image formats in VB.NET, including Jpg, Png, Bmp, Gif, Tiff, Bitmap, .NET Graphics, and REImage.
pdf extract images; extract images from pdf files
Function library
Free interconnection of digital signals
Free configuration of digital input signals
10
346
EDS82EV903  EN  3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0410
(Cont.)
Possible digital signal sources for
C0410
  343
0
Not assigned (FIXED−FREE)
1
Digital input X3/E1 (DIGIN1)
2
Digital input X3/E2 (DIGIN2)
3
Digital input X3/E3 (DIGIN3)
4
Digital input X3/E4 (DIGIN4)
5 (A)
Digital input X3/E5 (DIGIN5)
6 (A)
Digital input X3/E6 (DIGIN6)
7
PTC input (X2.2/T1, X2.2/T2)
Only connect potential−free
switches to T1/T2!
T1/T2 is active ("HIGH") when the
switch is closed
AIF control word (AIF−CTRL)
10
Bit 0
...
...
25
Bit 15
CAN−IN1.W1 or FIF−IN.W1
30
Bit 0
...
...
45
Bit 15
CAN−IN1.W2 or FIF−IN.W2
50
Bit 0
...
...
65
Bit 15
CAN−IN2.W1
70
Bit 0
...
...
85
Bit 15
CAN−IN2.W2
90
Bit 0
...
...
105
Bit 15
Status application I/O
Only active for operation with
application I/O
140
Torque threshold 1 reached
(MCTRL1−MSET1=MOUT)
141
Torque threshold 2 reached
(MCTRL1−MSET2=MOUT)
142
Limitation of process controller output
reached (PCTRL1−LIM)
143...1
72
Reserved
200
Bit−by−bit assignment of control words
(FIF−CTRL1, FIF−CTRL2) of the fieldbus
function module to FIF (e.g. INTERBUS
or PROFIBUS−DP)
Also see C0005
Digital output signals
201
As in C0415, selection 1
...
...
231
As in C0415, selection 31
255
Not assigned (FIXED−FREE)
Function library
Free interconnection of digital signals
Free configuration of digital input signals
10
347
EDS82EV903   EN   3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0411
Level inversion
− digital inputs
0
0
Level inversion switched off
By entering the sum of the
selected values you can invert
several inputs.
C0114 and C0411 are the same
The "Change over parameter
set" cannot be inverted!
1
E1 inverted
2
E2 inverted
4
E3 inverted
8
E4 inverted
16
E5 inverted
Only application I/O
32
E6 inverted
Only application I/O
64
T1/T2 inverted
Only connect potential−free
switches to T1/T2.
T1/T2 is active when the switch is
open.
Signal linkage
The internal digital signals are linked with an external signal source by entering the
selection figure of the external signal in the corresponding subcode of C0410. C0410 can
be different for the parameter sets.
Examples
ƒ
C0410/10 = 2   Terminal X3/E2 is the signal source for controller inhibit (CINH)
ƒ
C0410/15 = 32   CAN−IN1/word1, Bit 3 is the signal source for the DC injection
brake (DCB)
Note!
The process data input words CAN−IN1.W1, CAN−IN1.W2, CAN−IN2.W1 and
CAN−IN2.W2 can be defined as analog word or as digital word (16 bit). If you
link internal digital signals (C0410/x = 30 ... 105), they must be defined as
digital input words. Otherwise the controller would interpret the bit control
information incorrectly.
Signal level
ƒ
Terminals (X3/E1 ... X3/E6):
–HIGH = +12 V ... +30 V
–LOW = 0 V ... +3 V
ƒ
Process data input words:
–HIGH = bit logic 1
–LOW = bit logic 0
ƒ
Response times: 1.5 ... 2.5 ms
Function library
Free interconnection of digital signals
Free configuration of digital outputs
10
348
EDS82EV903  EN  3.0
10.12.2
Free configuration of digital outputs 
Description
ƒ
The digital outputs (X3/A1, X3/A2, relay output K1, relay output K2) can be freely
assigned to internal digital signals.
ƒ
A signal source can be assigned to several targets.
Note!
ƒ
Use C0008 to assign some internal signal sources to the relay output D1.
C0415/1 is automatically adapted.
ƒ
Use C0117 to assign some internal signal sources to the digital output
X3/A1. C0415/2 is automatically adapted.
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze
Selection
C0415
Free
configuration
of digital
outputs
Output of digital signals to terminals
  348
1
Relay output
K1 (RELAY,
motec version
151:)
Digital
switching
output K1
(motec version
152, 153)
25
TRIP error message (DCTRL1−TRIP)
A selection in C0008 is copied into
C0415/1. Change of C0415/1 sets
C0008 = 255!
2
Digital output
X3/A1
(DIGOUT1)
16
Ready for operation (DCTRL1−RDY)
A selection in C0117 is copied into
C0415/2. Change of C0415/2 sets
C0117 = 255!
3
(A)
Digital output
X3/A2
(DIGOUT2)
255
Not assigned (FIXED−FREE)
Function library
Free interconnection of digital signals
Free configuration of digital outputs
10
349
EDS82EV903   EN   3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0415
(Cont.)
Possible digital signals for C0415
  348
0
Not assigned (FIXED−FREE)
1
Parameter set 2 or parameter set 4 is
active (DCTRL1−PAR−B0)
PAR−B1 PAR−B0
LOW
LOW
LOW
HIGH
HIGH
LOW
HIGH
HIGH
Active
PAR1
PAR2
PAR3
PAR4
2
Pulse inhibit active (DCTRL1−IMP)
3
I
max
limit reached (MCTRL1−IMAX)
(C0014 = −5−: torque setpoint reached)
4
Frequency setpoint reached
(DCTRL1−RFG1=NOUT)
5
Ramp function generator 1: input =
output (NSET1−RFG1−I=O)
RFG1 = ramp function generator −
main setpoint
6
Values have fallen below frequency
threshold Q
min
(f < C0017)
(PCTRL1−QMIN)
LOW active
7
Output frequency = 0
(DCTRL1−NOUT=0)
8
Controller inhibit active (DCTRL1−CINH)
9...12
Reserved
13
Group signal
(DCTRL1−OH−PTC−LP1−FAN1−WARN):
Warning − overtemperature (
max
− 5
°C) (DCTRL1−OH−WARN)
or
Warning − motor overtemperature
(DCTRL1−LP1−PTC−WARN)
or
Set C0119 = 2 or C0119 = 5
Motor phase failure warning
(DCTRL1−LP1−WARN)
or
Set C0597 = 2
Warning − fan failure
(only active with 8200 motec)
With 8200 vector, C0608 must be
set to 0
14
DC bus overvoltage (DCTRL1−OV)
15
CCW rotation (DCTRL1−CCW)
16
Ready for operation (DCTRL1−RDY)
17
Parameter set 3 or parameter set 4
active (DCTRL1−PAR−B1)
PAR−B1 PAR−B0
LOW
LOW
LOW
HIGH
HIGH
LOW
HIGH
HIGH
Active
PAR1
PAR2
PAR3
PAR4
18
Values have fallen below TRIP or Q
min
or pulse inhibit (IMP) is active
(DCTRL1−TRIP−QMIN−IMP)
19
PTC warning (DCTRL1−PTC−WARN)
Set C0119 = 2 or C0119 = 5
Status of relay K
SR
Only with 8200 vector 15 ...90 kW,
variant "safe standstill":
HIGH = pulse inhibit active by
"safe standstill"
LOW = no pulse inhibit by "safe
standstill"
Function library
Free interconnection of digital signals
Free configuration of digital outputs
10
350
EDS82EV903  EN  3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0415
(Cont.)
Possible digital signals for C0415
  348
20
Apparent motor current < current
threshold (DCTRL1−IMOT<ILIM)
V−belt monitoring
Apparent motor current = C0054
Current threshold = C0156
Frequency threshold Q
min
= C0017
21
Apparent motor current < current
threshold and output frequency >
Frequency threshold Q
min
(DCTRL1−(IMOT<ILIM)−QMIN)
22
Apparent motor current < current
threshold and ramp function generator
1: input = output
(DCTRL1−(IMOT<ILIM)−RFG−I=0)
23
Motor phase failure warning
(DCTRL1−LP1−WARN)
Set C0597 = 2
24
Min. output frequency reached
(f  C0010) (PCTRL1−NMIN)
LOW active
25
TRIP error message (DCTRL1−TRIP)
26
Motor is running (DCTRL1−RUN)
27
Motor is running / CW rotation
(DCTRL1−RUN−CW)
28
Motor is running / CCW rotation
(DCTRL1−RUN−CCW)
29
Process controller input = process
controller output (PCTRL1−SET=ACT)
30
Reserved
31
Apparent motor current 
>
Current
threshold and ramp function generator
1: input = output
(DCTRL1−(IMOT>ILIM)−RFG−I=0)
Overload monitoring
Apparent motor current = C0054
Current threshold = C0156
32
Digital input X3/E1
Digital inputs
33
Digital input X3/E2
34
Digital input X3/E3
35
Digital input X3/E4
36 (A)
Digital input X3/E5
37 (A)
Digital input X3/E6
38
PTC input X2.2/T1, X2.2/T2
Only connect potential−free
switches to T1/T2!
T1/T2 is active ("HIGH") when the
switch is closed
Documents you may be interested