Technical data
Operation with rated power (normal operation)
Rated data for 400 V mains voltage
4
41
EDS82EV903   EN   3.0
Typical motor power −
three−phase asynchronous
motor (4−pole)
P
rated
[kW]
15
22
30
P
rated
[hp]
20
30
40
8200 vector type
With mains filter
E82xV153K4B3xx
E82xV223K4B3xx
E82xV303K4B3xx
Without mains filter
E82xV153K4B2xx 3)
E82xV223K4B2xx 3)
E82xV303K4B2xx 3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke/mains
filter
I
mains
[A]
43.5
With mains choke/mains filter
I
mains
[A]
29
42
55.0
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
10.2
4
0
Rated output
current at
switching
frequency
1 kHz sin
I
r
[A]
32
47
59
2 kHz sin
4 kHz sin
8 kHz sin
I
r
[A]
29
43
47
4)
16 kHz sin
2)
I
r
[A]
21
30
35
1 kHz
I
r
[A]
32
47
59
2 kHz
4 kHz
8 kHz
I
r
[A]
32
47
59
16 kHz 2)
I
r
[A]
24
35
44
Max. permissible
output current for
60 s at switching
frequency
1 kHz sin
I
max
[A]
48
70.5
89
2 kHz sin
4 kHz sin
8 kHz sin
I
max
[A]
43
64
70
4)
16 kHz sin
2)
I
max
[A]
31
46
53
1 kHz
I
max
[A]
48
70.5
89
2 kHz
4 kHz
8 kHz
I
max
[A]
48
70.5
89
16 kHz
2)
I
max
[A]
36
53
66
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
430
640
810
E82DV... inside/outside
P
loss
[W]
143/287
213/427
270/540
E82CV... inside/cooler
P
loss
[W]
143/287
213/427
Dimensions
Dependent on the mounting variant (  61)
Mass with mains
filter
E82EV...
m [kg]
34
34
E82DV...
m [kg]
34
34
E82CV...
m [kg]
Separate mains filter
Mass without
mains filter
E82EV...
m [kg]
15
15
E82DV...
m [kg]
15
15
E82CV...
m [kg]
13
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if  reaches max. − 5 °C
3)
Operation only permitted with mains choke (  106)
4)
Only operate with automatic switching frequency reduction (C144 = 1). Ensure that the specified current values are
not exceeded.
Extract images from pdf file - Select, copy, paste PDF images in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support PDF Image Extraction from a Page, a Region on a Page, and PDF Document
extract pictures from pdf; how to extract images from pdf in acrobat
Extract images from pdf file - VB.NET PDF Image Extract Library: Select, copy, paste PDF images in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support PDF Image Extraction from a Page, a Region on a Page, and PDF Document
extract images from pdf; extract images from pdf file
Technical data
Operation with rated power (normal operation)
Rated data for 400 V mains voltage
4
42
EDS82EV903  EN  3.0
Typical motor power −
three−phase asynchronous
motor (4−pole)
P
rated
[kW]
45
55
P
rated
[hp]
60
75
8200 vector type
With mains filter
E82xV453K4B3xx
E82xV553K4B3xx
Without mains filter
E82xV453K4B2xx 3)
E82xV553K4B2xx 3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke/mains
filter
I
mains
[A]
With mains choke/mains filter
I
mains
[A]
80
100
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
5.1
0
Rated output
current at
switching
frequency
1 kHz sin
I
r
[A]
89
110
2 kHz sin
4 kHz sin
8 kHz sin
I
r
[A]
59
4)
76
4)
16 kHz sin
2)
I
r
[A]
46
60
1 kHz
I
r
[A]
89
110
2 kHz
4 kHz
8 kHz
I
r
[A]
89
110
16 kHz
2)
I
r
[A]
54
77
Max. permissible
output current for
60 s at switching
frequency
1 kHz sin
I
max
[A]
134
165
2 kHz sin
4 kHz sin
8 kHz sin
I
max
[A]
88
4)
114
4)
16 kHz sin
2)
I
max
[A]
69
78
1 kHz
I
max
[A]
134
165
2 kHz
4 kHz
8 kHz
I
max
[A]
134
165
16 kHz
2)
I
max
[A]
81
100
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
1100
1470
E82DV... inside/outside
P
loss
[W]
367/733
490/980
E82CV... inside/cooler
P
loss
[W]
Dimensions
Dependent on the mounting variant (  61)
Mass with mains
filter
E82EV...
m [kg]
60
66
E82DV...
m [kg]
60
66
E82CV...
m [kg]
Mass without
mains filter
E82EV...
m [kg]
36
38
E82DV...
m [kg]
36
38
E82CV...
m [kg]
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if  reaches max. − 5 °C
3)
Operation only permitted with mains choke (  106)
4)
Only operate with automatic switching frequency reduction (C144 = 1). Ensure that the specified current values are
not exceeded.
C# PDF Text Extract Library: extract text content from PDF file in
Ability to extract highlighted text out of PDF control provides text extraction from PDF images and image extracting PDF text to another PDF file, TXT and SVG
pdf image extractor c#; extract images pdf acrobat
VB.NET PDF Text Extract Library: extract text content from PDF
Extract highlighted text out of PDF document. control provides text extraction from PDF images and image extracting PDF text to another PDF file, and other
extract image from pdf java; how to extract images from pdf file
Technical data
Operation with rated power (normal operation)
Rated data for 400 V mains voltage
4
43
EDS82EV903   EN   3.0
Typical motor power −
three−phase asynchronous
motor (4−pole)
P
rated
[kW]
75
90
P
rated
[hp]
100
125
8200 vector type
With mains filter
E82xV753K4B3xx
E82xV903K4B3xx
Without mains filter
E82xV753K4B2xx 3)
E82xV903K4B2xx 3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke/mains
filter
I
mains
[A]
With mains choke/mains filter
I
mains
[A]
135
165
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
28.1
40.8
Rated output
current at
switching
frequency
1 kHz sin
I
r
[A]
150
159
4)
2 kHz sin
4 kHz sin
8 kHz sin
I
r
[A]
92
4)
100
4)
16 kHz sin
2)
I
r
[A]
67
72
1 kHz
I
r
[A]
150
180
2 kHz
4 kHz
8 kHz
I
r
[A]
150
171
16 kHz
2)
I
r
[A]
105
108
Max. permissible
output current for
60 s at switching
frequency
1 kHz sin
I
max
[A]
225
238
4)
2 kHz sin
4 kHz sin
8 kHz sin
I
max
[A]
138
4)
150
4)
16 kHz sin
2)
I
max
[A]
87
94
1 kHz
I
max
[A]
225
270
2 kHz
4 kHz
8 kHz
I
max
[A]
225
221
16 kHz
2)
I
max
[A]
136
140
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
1960
2400
E82DV... inside/outside
P
loss
[W]
653/1307
800/1600
E82CV... inside/cooler
P
loss
[W]
Dimensions
Dependent on the mounting variant (  61)
Mass with mains
filter
E82EV...
m [kg]
112
E82DV...
m [kg]
112
E82CV...
m [kg]
Mass without
mains filter
E82EV...
m [kg]
59
E82DV...
m [kg]
59
E82CV...
m [kg]
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if  reaches max. − 5 °C
3)
Operation only permitted with mains choke (  106)
4)
Only operate with automatic switching frequency reduction (C144 = 1). Ensure that the specified current values are
not exceeded.
VB.NET PDF File Compress Library: Compress reduce PDF size in vb.
Reduce image resources: Since images are usually or large size, images size reducing can help to reduce PDF file size effectively.
extract image from pdf; pdf image text extractor
C# PDF File Compress Library: Compress reduce PDF size in C#.net
Reduce image resources: Since images are usually or large size, images size reducing can help to reduce PDF file size effectively.
how to extract text from pdf image file; some pdf image extractor
Technical data
Operation with rated power (normal operation)
Rated data for 500 V mains voltage
4
44
EDS82EV903  EN  3.0
4.4.3
Rated data for 500 V mains voltage
Basis of the data
AC mains connection
U
r
3/PE AC 400 V − 0 % ... 550 V + 0 %; 45 Hz − 0 % ... 65 Hz + 0 %
DC−mains connection
(alternatively)
U
DC
DC 565 V − 0 % ... 775 V + 0 %
Output voltage
With mains choke
V
M
3 ~ 0 ... approx. 94 % U
mains;
0 ... 650 Hz
without mains choke
V
M
3 ~ 0 ... U
mains;
0 ... 650 Hz
Periodic load change
60 s overcurrent with I
max
and 120 s base load with 75 % I
rated
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
0.55
0.75
P
rated
[hp]
0.75
1.0
8200 vector type
EMC filter integrated
E82xV551K4C0xx 
3)
E82xV751K4C0xx 
3)
Without EMC filter
E82xV551K4C4xx 3)
E82xV751K4C2xx 3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke
I
mains
[A]
2.0
2.6
with mains choke
I
mains
[A]
1.4
1.8
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
0.3
0.1
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
1.4
1.9
4 kHz sin
8 kHz sin
I
r
[A]
1.4
1.9
16 kHz sin 2)
I
r
[A]
0.9 4)
1.2 4)
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
2.7
3.6
4 kHz sin
8 kHz sin
I
max
[A]
2.7
3.6
16 kHz sin 2)
I
max
[A]
1.35 4)
1.85 4)
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
50
60
E82DV... inside/outside
P
loss
[W]
17/33
20/40
E82CV... inside/cooler
P
loss
[W]
17/33
20/40
Dimensions
Dependent on the mounting variant (  61)
Mass
E82EV...
m [kg]
1.2
E82DV...
m [kg]
1.2
E82CV...
m [kg]
0.9
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if  reaches max. − 5 °C
3)
Operation with mains voltages 484 V − 0 % ... 550 V + 0 % only permissible with brake resistor!
4)
Max. motor cable length 10 m!
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
VB.NET Components to combine various scanned images to PDF, such as tiff, jpg, png, gif, bmp, etc. Append one PDF file to the end of another one in VB.NET.
pdf image extractor; how to extract a picture from a pdf
C# PDF File Merge Library: Merge, append PDF files in C#.net, ASP.
Combine scanned images to PDF, such as tiff, jpg, png, gif, bmp, etc. Merge Microsoft Office Word, Excel and PowerPoint data to PDF form. Append one PDF file to
extract images from pdf files; extract jpg from pdf
Technical data
Operation with rated power (normal operation)
Rated data for 500 V mains voltage
4
45
EDS82EV903   EN   3.0
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
1.5
2.2
P
rated
[hp]
2.0
3.0
8200 vector type
EMC filter integrated
E82xV152K4C0xx 3)
E82xV222K4C0xx 3)
Without EMC filter
E82xV152K4C4xx 3)
E82xV222K4C2xx 3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke
I
mains
[A]
4.4
5.8
with mains choke
I
mains
[A]
3.1
4.1
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
1.1
0.4
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
3.1
4.5
4 kHz sin
8 kHz sin
I
r
[A]
3.1
4.5
16 kHz sin 
2)
I
r
[A]
2.0
2.9
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
5.9
8.4
4 kHz sin
8 kHz sin
I
max
[A]
5.9
8.4
16 kHz sin 2)
I
max
[A]
3.0
4.4
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
100
130
E82DV... inside/outside
P
loss
[W]
33/67
43/87
E82CV... inside/cooler
P
loss
[W]
33/67
43/87
Dimensions
Dependent on the mounting variant (  61)
Mass
E82EV...
m [kg]
1.6
E82DV...
m [kg]
1.6
E82CV...
m [kg]
1.1
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if  reaches max. − 5 °C
3)
Operation with mains voltages 484 V − 0 % ... 550 V + 0 % only permissible with brake resistor!
VB.NET PDF Page Extract Library: copy, paste, cut PDF pages in vb.
Dim outputFilePath As String = Program.RootPath + "\\" 1.pdf" newDoc.Save( outputFilePath). VB.NET: Extract All Images from PDF Document.
extract pdf pages to jpg; how to extract images from pdf
C# PDF File Split Library: Split, seperate PDF into multiple files
Application. Best and professional adobe PDF file splitting SDK for Visual Studio .NET. outputOps); Divide PDF File into Two Using C#.
extract images from pdf; how to extract images from pdf files
Technical data
Operation with rated power (normal operation)
Rated data for 500 V mains voltage
4
46
EDS82EV903  EN  3.0
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
3.0
4.0
5.5
P
rated
[hp]
4.0
5.0
7.5
8200 vector type
EMC filter integrated
E82xV302K4C0xx
E82xV402K4C0xx
E82xV552K4C0xx
Without EMC filter
E82xV302K2C4xx
E82xV402K4C2xx
E82xV552K4C2xx
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke
I
mains
[A]
7.2
9.8
13.4
with mains choke
I
mains
[A]
5.6
7.0
9.6
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
1.7
0.8
1.1
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
5.8
7.6
10.4
4 kHz sin
8 kHz sin
I
r
[A]
5.8
7.6
10.4
16 kHz sin
2)
I
r
[A]
3.8
4.9
6.8
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
11.0
14.2
19.5
4 kHz sin
8 kHz sin
I
max
[A]
11.0
14.2
19.5
16 kHz sin
2)
I
max
[A]
5.7
7.9
10.0
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
145
180
230
E82DV... inside/outside
P
loss
[W]
48/97
60/120
77/153
E82CV... inside/cooler
P
loss
[W]
48/97
60/120
77/153
Dimensions
Dependent on the mounting variant (  61)
Mass
E82EV...
m [kg]
2.9
E82DV...
m [kg]
2.9
E82CV...
m [kg]
2.4
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if  reaches max. − 5 °C
Technical data
Operation with rated power (normal operation)
Rated data for 500 V mains voltage
4
47
EDS82EV903   EN   3.0
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
7.5
11
P
rated
[hp]
10.0
15
8200 vector type
EMC filter integrated
E82xV752K4C0xx
E82xV113K4C0xx 3)
Without EMC filter
E82xV752K4C4xx
E82xV113K4C2xx 3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke
I
mains
[A]
17.2
with mains choke
I
mains
[A]
12.0
16.8
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
1.5
0
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
13.2
18.8
4 kHz sin
8 kHz sin
I
r
[A]
13.2
18.8
16 kHz sin
2)
I
r
[A]
8.6
12.2
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
24.8
35.3
4 kHz sin
8 kHz sin
I
max
[A]
24.8
35.3
16 kHz sin
2)
I
max
[A]
12.9
18.3
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
300
410
E82DV... inside/outside
P
loss
[W]
100/200
137/273
E82CV... inside/cooler
P
loss
[W]
100/200
137/273
Dimensions
Dependent on the mounting variant (  61)
Mass
E82EV...
m [kg]
3.6
E82DV...
m [kg]
3.6
E82CV...
m [kg]
3.0
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if  reaches max. − 5 °C
3)
Operation only permitted with mains choke or mains filter (  106)
Technical data
Operation with rated power (normal operation)
Rated data for 500 V mains voltage
4
48
EDS82EV903  EN  3.0
Typical motor power −
three−phase asynchronous
motor (4−pole)
P
rated
[kW]
18.5
30
37
P
rated
[hp]
25
40
50
8200 vector type
With mains filter
E82xV153K4B3xx
E82xV223K4B3xx
E82xV303K4B3xx
Without mains filter
E82xV153K4B2xx 3)
E82xV223K4B2xx 3)
E82xV303K4B2xx 3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke/mains
filter
I
mains
[A]
43.5
With mains choke/mains filter
I
mains
[A]
29
42
55
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
11.8
4.6
0
Rated output
current at
switching
frequency
1 kHz sin
I
rated
[A]
5)
30.5
45
56
2 kHz sin
4 kHz sin
8 kHz sin
I
r
[A]
27
41
44
4)
16 kHz sin
2)
I
r
[A]
19
28
30
1 kHz
I
r
[A]
32
47
56
2 kHz
4 kHz
8 kHz
I
r
[A]
32
47
56
16 kHz
2)
I
r
[A]
22
33
41
Max. permissible
output current for
60 s at switching
frequency
1 kHz sin
I
max
[A]
46
66.5
65
2 kHz sin
4 kHz sin
8 kHz sin
I
max
[A]
41
61
65
4)
16 kHz sin
2)
I
max
[A]
29
42
45
1 kHz
I
max
[A]
48
70.5
84
2 kHz
4 kHz
8 kHz
I
max
[A]
48
70.5
84
16 kHz
2)
I
max
[A]
33
49
61
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
430
640
810
E82DV... inside/outside
P
loss
[W]
143/287
213/427
270/540
E82CV... inside/cooler
P
loss
[W]
Dimensions
Dependent on the mounting variant (  61)
Mass with mains
filter
E82EV...
m [kg]
34
34
E82DV...
m [kg]
34
34
E82CV...
m [kg]
Separate mains filter
Mass without
mains filter
E82EV...
m [kg]
15
15
E82DV...
m [kg]
15
15
E82CV...
m [kg]
13
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if  reaches max. − 5 °C
3)
Operation only permitted with mains choke or mains filter (  106)
4)
Only operate with automatic switching frequency reduction (C144 = 1). Ensure that the specified current values are
not exceeded.
Technical data
Operation with rated power (normal operation)
Rated data for 500 V mains voltage
4
49
EDS82EV903   EN   3.0
Typical motor power −
three−phase asynchronous
motor (4−pole)
P
rated
[kW]
55
75
P
rated
[hp]
75
100
8200 vector type
With mains filter
E82xV453K4B3xx
E82xV553K4B3xx
Without mains filter
E82xV453K4B2xx 3)
E82xV553K4B2xx 3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke/mains
filter
I
mains
[A]
With mains choke/mains filter
I
mains
[A]
80
100
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
5.9
0
Rated output
current at
switching
frequency
1 kHz sin
I
r
[A]
84
104
2 kHz sin
4 kHz sin
8 kHz sin
I
r
[A]
55
4)
71
4)
16 kHz sin
2)
I
r
[A]
39
55
1 kHz
I
r
[A]
84
105
2 kHz
4 kHz
8 kHz
I
r
[A]
84
105
16 kHz
2)
I
r
[A]
58
72
Max. permissible
output current for
60 s at switching
frequency
1 kHz sin
I
max
[A]
126
156
2 kHz sin
4 kHz sin
8 kHz sin
I
max
[A]
82
4)
107
4)
16 kHz sin
2)
I
max
[A]
63
72
1 kHz
I
max
[A]
126
157
2 kHz
4 kHz
8 kHz
I
max
[A]
126
157
16 kHz
2)
I
max
[A]
75
94
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
1100
1470
E82DV... inside/outside
P
loss
[W]
367/733
490/980
E82CV... inside/cooler
P
loss
[W]
Dimensions
Dependent on the mounting variant (  61)
Mass with mains
filter
E82EV...
m [kg]
60
66
E82DV...
m [kg]
60
66
E82CV...
m [kg]
Mass without
mains filter
E82EV...
m [kg]
36
38
E82DV...
m [kg]
36
38
E82CV...
m [kg]
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if  reaches max. − 5 °C
3)
Operation only permitted with mains choke or mains filter (  106)
4)
Only operate with automatic switching frequency reduction (C144 = 1). Ensure that the specified current values are
not exceeded.
Technical data
Operation with rated power (normal operation)
Rated data for 500 V mains voltage
4
50
EDS82EV903  EN  3.0
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
90
110
P
rated
[hp]
125
150
8200 vector type
With mains filter
E82xV753K4B3xx
E82xV903K4B3xx
Without mains filter
E82xV753K4B2xx 3)
E82xV903K4B2xx 3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke/mains
filter
I
mains
[A]
With mains choke/mains filter
I
mains
[A]
135
165
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
32.4
47.1
Rated output
current at
switching
frequency
1 kHz sin
I
r
[A]
141
149
4)
2 kHz sin
4 kHz sin
8 kHz sin
I
r
[A]
86
4)
94
4)
16 kHz sin
2)
I
r
[A]
60
63
1 kHz
I
r
[A]
142
171
2 kHz
4 kHz
8 kHz
I
r
[A]
142
162
16 kHz
2)
I
r
[A]
98
99
Max. permissible
output current for
60 s at switching
frequency
1 kHz sin
I
max
[A]
212
223
4)
2 kHz sin
4 kHz sin
8 kHz sin
I
max
[A]
169
4)
141
4)
16 kHz sin
2)
I
max
[A]
78
83
1 kHz
I
max
[A]
213
256
2 kHz
4 kHz
8 kHz
I
max
[A]
213
211
16 kHz
2)
I
max
[A]
128
130
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
1960
2400
E82DV... inside/outside
P
loss
[W]
653/1307
800/1600
E82CV... inside/cooler
P
loss
[W]
Dimensions
Dependent on the mounting variant (  61)
Mass with mains
filter
E82EV...
m [kg]
112
E82DV...
m [kg]
112
E82CV...
m [kg]
Mass without
mains filter
E82EV...
m [kg]
59
E82DV...
m [kg]
59
E82CV...
m [kg]
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if  reaches max. − 5 °C
3)
Operation only permitted with mains choke or mains filter (  106)
4)
Only operate with automatic switching frequency reduction (C144 = 1). Ensure that the specified current values are
not exceeded.
Documents you may be interested
Documents you may be interested