Function library
Code table
10
411
EDS82EV903   EN   3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
13 DCTRL1−PAR2/
4
255
Not assigned (FIXED−FREE)
Change over parameter set
(only possible if C0988 = 0)
C0410/13 and C0410/14 must
have the same source in all used
parameter sets. Otherwise
changeover between parameter
sets is not possible (error message
CE5 or CE7).
14
DCTRL1−PAR3/
4
255
Not assigned (FIXED−FREE)
C0410/13
C0410/
14
LOW
LOW
HIGH
LOW
LOW
HIGH
HIGH
HIGH
Active
PAR1
PAR2
PAR3
PAR4
15
MCTRL1−DCB
3
Digital input X3/E3
DC injection brake
16
(A)
PCTRL1−RFG2−
LOADI
255
Not assigned (FIXED−FREE)
Connect actual process controller
value (PCTRL1−ACT) to process
controller ramp function
generator (PCTRL1−RFG2)
17
DCTRL1−H/Re
255
Not assigned (FIXED−FREE)
Manual/remote changeover
18
PCTRL1−OFF
255
Not assigned (FIXED−FREE)
Switch off I component of the
process controller
19
PCTRL1−OFF
255
Not assigned (FIXED−FREE)
Switch off process controller
20
Reserved
255
Not assigned (FIXED−FREE)
Do not change 255!
21
PCTRL1−STOP
255
Not assigned (FIXED−FREE)
Stop process controller ("freeze"
value)
22
DCTRL1−CW/
QSP
255
Not assigned (FIXED−FREE)
Fail−safe change of the direction
of rotation
23
DCTRL1−CCW/
QSP
255
Not assigned (FIXED−FREE)
24
DFIN1−ON
255
Not assigned (FIXED−FREE)
0 = frequency input inactive
1 = frequency input active 
Configure frequency input with
C0425 and C0426
Extract pictures pdf - Select, copy, paste PDF images in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support PDF Image Extraction from a Page, a Region on a Page, and PDF Document
extract images from pdf online; how to extract pictures from pdf files
Extract pictures pdf - VB.NET PDF Image Extract Library: Select, copy, paste PDF images in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support PDF Image Extraction from a Page, a Region on a Page, and PDF Document
extract images from pdf acrobat; extract text from pdf image
Function library
Code table
10
412
EDS82EV903  EN  3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0410
(Cont.)
  343
25
(A)
PCTRL1−FOLL1−
0
255
Not assigned (FIXED−FREE)
Run follow−up controller to "0"
along reset ramp C0193
26
(A)
Reserved
255
Not assigned (FIXED−FREE)
27
(A)
NSET1−TI1/3
255
Not assigned (FIXED−FREE)
Connect acceleration times
28
(A)
NSET1−TI2/3
255
Not assigned (FIXED−FREE)
C0410/27
C0410/
28
LOW
LOW
HIGH
LOW
LOW
HIGH
HIGH
HIGH
Active
C0012;
C0013
T
ir
1; T
if
1
T
ir
2; T
if
2
T
ir
3; T
if
3
29
(A)
PCTRL1−
FADING
255
Not assigned (FIXED−FREE)
Fade−in (LOW)/fade−out (HIGH)
process controller output
30
(A)
PCTRL1−INV−
ON
255
Not assigned (FIXED−FREE)
Invert process controller output
31
(A)
PCTRL1−NADD−
OFF
255
Not assigned (FIXED−FREE)
Switch off additonal setpoint
32
(A)
PCTRL1−RFG2−0
255
Not assigned (FIXED−FREE)
Ramp function generator input −
run process controller to "0" along
ramp C0226
33
(A)
NSET1−JOG4/5
/6/7
255
Not assigned (FIXED−FREE)
VB.NET PDF Convert to Word SDK: Convert PDF to Word library in vb.
application. In addition, texts, pictures and font formatting of source PDF file are accurately retained in converted Word document file.
extract images from pdf file; extract image from pdf in
VB.NET Image: VB.NET Codes to Load Images from File / Stream in .
When evaluating this VB.NET imaging library with pictures of your own We are dedicated to provide powerful & profession imaging controls, PDF document, image to
extract jpeg from pdf; extract photo from pdf
Function library
Code table
10
413
EDS82EV903   EN   3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0410
(Cont.)
Possible digital signal sources for
C0410
  343
0
Not assigned (FIXED−FREE)
1
Digital input X3/E1 (DIGIN1)
2
Digital input X3/E2 (DIGIN2)
3
Digital input X3/E3 (DIGIN3)
4
Digital input X3/E4 (DIGIN4)
5 (A)
Digital input X3/E5 (DIGIN5)
6 (A)
Digital input X3/E6 (DIGIN6)
7
PTC input (X2.2/T1, X2.2/T2)
Only connect potential−free
switches to T1/T2!
T1/T2 is active ("HIGH") when the
switch is closed
AIF control word (AIF−CTRL)
10
Bit 0
...
...
25
Bit 15
CAN−IN1.W1 or FIF−IN.W1
30
Bit 0
...
...
45
Bit 15
CAN−IN1.W2 or FIF−IN.W2
50
Bit 0
...
...
65
Bit 15
CAN−IN2.W1
70
Bit 0
...
...
85
Bit 15
CAN−IN2.W2
90
Bit 0
...
...
105
Bit 15
Status application I/O
Only active for operation with
application I/O
140
Torque threshold 1 reached
(MCTRL1−MSET1=MOUT)
141
Torque threshold 2 reached
(MCTRL1−MSET2=MOUT)
142
Limitation of process controller output
reached (PCTRL1−LIM)
143...1
72
Reserved
200
Bit−by−bit assignment of control words
(FIF−CTRL1, FIF−CTRL2) of the fieldbus
function module to FIF (e.g. INTERBUS
or PROFIBUS−DP)
Also see C0005
Digital output signals
201
As in C0415, selection 1
...
...
231
As in C0415, selection 31
255
Not assigned (FIXED−FREE)
C#: Use OCR SDK Library to Get Image and Document Text
a digital camera, scanned document or image-only PDF using C# color image recognition for scanned documents and pictures in C#. Steps to Extract Text from Image.
pdf image extractor online; some pdf image extract
VB.NET Image: Sharpen Images with DocImage SDK for .NET
VB.NET Coding. When you have made certain corrections in your VB.NET project photo or image files, you might want to sharpen your pictures before saving them
extract image from pdf c#; how to extract images from pdf in acrobat
Function library
Code table
10
414
EDS82EV903  EN  3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0411
Level inversion
− digital inputs
0
0
Level inversion switched off
By entering the sum of the
selected values you can invert
several inputs.
C0114 and C0411 are the same
The "Change over parameter
set" cannot be inverted!
1
E1 inverted
2
E2 inverted
4
E3 inverted
8
E4 inverted
16
E5 inverted
Only application I/O
32
E6 inverted
Only application I/O
64
T1/T2 inverted
Only connect potential−free
switches to T1/T2.
T1/T2 is active when the switch is
open.
VB.NET Image: VB.NET Code to Create Watermark on Images in .NET
image one onto it, and whether to burn it to the pictures to make We are dedicated to provide powerful & profession imaging controls, PDF document, tiff files
extract images pdf acrobat; extract images pdf
VB.NET Image: Codings for Image Filter Processing with .NET Image
RasterEdge .NET Image SDK provides many different and interesting filters for your pictures / photos with simple and a few Visual Basic .NET programming codings
extract jpg pdf; extract text from pdf image
Function library
Code table
10
415
EDS82EV903   EN   3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0412
Free
configuration
of analog input
signals
Linking analog signal sources to internal analog
signals
A selection in C0005 or C0007 is
copied to the corresponding
subcode of C0412. A change in
C0412 sets C0005 = 255 and
C0007 = 255!
  328
1
Setpoint 1
(NSET1–N1)
1
Analog input 1 (AIN1−OUT):
X3/8 (standard I/O)
X3/1U or X3/1I (application I/O)
Either NSET1−N1 or
NSET1−N2 active
Changeover with
C0410/17
Parameter
channel:
C0046
2
Setpoint 2
(NSET1−N2)
1
Parameter
channel:
C0044
3
Additional
setpoint
(PCTRL1−NADD)
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
Acts additively on
NSET1−N1,
NSET1−N2, JOG
values and the 
functionof the
keypad
Parameter
channel:
C0049
4
Process
controller
setpoint 1
(PCTRL1−SET1)
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
Application of the motor
potentiometer for the selection of
the process controller setpoint
(C0142/4 = 3) is only permissible
in conjunction with the
application I/O!
5
Actual process
controller
value
(PCTRL1−ACT)
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
Parameter
channel:
C0051 if
C0238 = 1,
2
6
Torque
setpoint or
torque limit
(MCTRL1−
MSET)
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
Observe C0014!
An actual torque
value is not
required.
16384  100 %
torque setpoint
Condition if
selection via
terminal
(C0412/6 = 1, 2 or
4):
–The gain of the
analog input is
set to: C0414/x,
C0426 =
32768/C0011
[%]
Parameter
channel:
C0047
7
Reserved
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
8
MCTRL1−VOLT−
ADD
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
For special applications only.
Alterations only after consultation
with Lenze!
9
MCTRL1−PHI−
ADD
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
C# Imaging - Scan RM4SCC Barcode in C#.NET
& decode RM4SCC barcode from scanned documents and pictures in your Decode RM4SCC from documents (PDF, Word, Excel and PPT) and extract barcode value as
how to extract images from pdf file; how to extract text from pdf image file
VB Imaging - VB Code 93 Generator Tutorial
Visual VB examples here for developers to create and write Code 93 linear barcode pictures on PDF documents, multi-page TIFF, Microsoft Office Word, Excel and
extract images from pdf files without using copy and paste; extract images from pdf files
Function library
Code table
10
416
EDS82EV903  EN  3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0412
(Cont.)
Possible analog signal sources for
C0412
  328
0
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
1
Analog input 1 (AIN1−OUT)
X3/8 (standard I/O)
X3/1U or X3/1I (application I/O)
2
Frequency input (DFIN1−OUT)
Observe C0410/24, C0425, C0426,
C0427
3
Motor potentiometer (MPOT1−OUT)
4 (A)
Analog input 2 (AIN2−OUT)
X3/2U or X3/2I
5 ... 9
Input signal is constant = 0 (FIXED0)
10
AIF input word 1 (AIF−IN.W1)
Only evaluated if C0001 = 3!
11
AIF input word 2 (AIF−IN.W2)
20
CAN−IN1.W1 or FIF−IN.W1
± 24000  ± 480 Hz
214  100 % rated motor torque
21
CAN−IN1.W2 or FIF−IN.W2
22
CAN−IN1.W3 or FIF−IN.W3
23
CAN−IN1.W4 or FIF−IN.W4
30
CAN−IN2.W1
31
CAN−IN2.W2
32
CAN−IN2.W3
33
CAN−IN2.W4
200
Word−by−word signal assignment of
the fieldbus function module to FIF
(e.g. INTERBUS or PROFIBUS−DP)
Also see C0005
228 (A)
PCTRL1−ACT
229 (A)
PCTRL1−SET
230 (A)
PCTRL1−OUT
231 (A)
NSET1−RFG1−IN
232 (A)
NSET1−NOUT
233 (A)
PCTRL1−PID−OUT
234 (A)
PCTRL1−NOUT
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
Either NSET1−N1 or NSET1−N2
active
C0413
*
Offset − analog
inputs
−200.0
{0.1 %}
200.0
The upper limit of the setpoint
range from C0034 corresponds to
100 %
  298
1
AIN1−OFFSET
0.0
Setting for X3/8 or X3/1U, X3/1I
C0413/1 and C0026 are the same
2
AIN2−OFFSET
0.0
Setting for X3/2U, X3/2I
(only application I/O)
C0414
*
Gain − analog
inputs
−1500.0
{0.1 %}
1500.0
100.0 % = gain 1
Inverted setpoint selection
through negative gain and
negative offset
1
AIN1−GAIN
100.0
Setting for X3/8 or X3/1U, X3/1I
C0414/1 and C0027 are the same
2
AIN2−GAIN
100.0
Setting for X3/2U, X3/2I
(only application I/O)
C# Imaging - C# Code 93 Generator Tutorial
Visual C# examples here for developers to create and write Code 93 linear barcode pictures on PDF documents, multi-page TIFF, Microsoft Office Word, Excel and
how to extract images from pdf; pdf image extractor online
VB.NET TIFF: How to Draw Picture & Write Text on TIFF Document in
Many users concern about the issue of how to draw pictures or write text We are dedicated to provide powerful & profession imaging controls, PDF document, tiff
some pdf image extractor; extract image from pdf using
Function library
Code table
10
417
EDS82EV903   EN   3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0415
Free
configuration
of digital
outputs
Output of digital signals to terminals
  348
1
Relay output
K1 (RELAY,
motec version
151)
Digital
switching
output K1
(motec version
152, 153)
25
TRIP error message (DCTRL1−TRIP)
A selection in C0008 is copied into
C0415/1. Change of C0415/1 sets
C0008 = 255!
2
Digital output
X3/A1
(DIGOUT1)
16
Ready for operation (DCTRL1−RDY)
A selection in C0117 is copied into
C0415/2. Change of C0415/2 sets
C0117 = 255!
3
(A)
Digital output
X3/A2
(DIGOUT2)
255
Not assigned (FIXED−FREE)
Function library
Code table
10
418
EDS82EV903  EN  3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0415
(Cont.)
Possible digital signals for C0415
  348
0
Not assigned (FIXED−FREE)
1
Parameter set 2 or parameter set 4 is
active (DCTRL1−PAR−B0)
PAR−B1 PAR−B0
LOW
LOW
LOW
HIGH
HIGH
LOW
HIGH
HIGH
Active
PAR1
PAR2
PAR3
PAR4
2
Pulse inhibit active (DCTRL1−IMP)
3
I
max
limit reached (MCTRL1−IMAX)
(C0014 = −5−: torque setpoint reached)
4
Frequency setpoint reached
(DCTRL1−RFG1=NOUT)
5
Ramp function generator 1: input =
output (NSET1−RFG1−I=O)
RFG1 = ramp function generator −
main setpoint
6
Values have fallen below frequency
threshold Q
min
(f < C0017)
(PCTRL1−QMIN)
LOW active
7
Output frequency = 0
(DCTRL1−NOUT=0)
8
Controller inhibit active (DCTRL1−CINH)
9...12
Reserved
13
Group signal
(DCTRL1−OH−PTC−LP1−FAN1−WARN):
Warning − overtemperature (
max
− 5
°C) (DCTRL1−OH−WARN)
or
Warning − motor overtemperature
(DCTRL1−LP1−PTC−WARN)
or
Set C0119 = 2 or C0119 = 5
Motor phase failure warning
(DCTRL1−LP1−WARN)
or
Set C0597 = 2
Warning − fan failure
(only active with 8200 motec)
With 8200 vector, C0608 must be
set to 0
14
DC bus overvoltage (DCTRL1−OV)
15
CCW rotation (DCTRL1−CCW)
16
Ready for operation (DCTRL1−RDY)
17
Parameter set 3 or parameter set 4
active (DCTRL1−PAR−B1)
PAR−B1 PAR−B0
LOW
LOW
LOW
HIGH
HIGH
LOW
HIGH
HIGH
Active
PAR1
PAR2
PAR3
PAR4
18
Values have fallen below TRIP or Q
min
or pulse inhibit (IMP) is active
(DCTRL1−TRIP−QMIN−IMP)
19
PTC warning (DCTRL1−PTC−WARN)
Set C0119 = 2 or C0119 = 5
Status of relay K
SR
Only with 8200 vector 15 ...90 kW,
variant "safe standstill":
HIGH = pulse inhibit active by
"safe standstill"
LOW = no pulse inhibit by "safe
standstill"
Function library
Code table
10
419
EDS82EV903   EN   3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0415
(Cont.)
Possible digital signals for C0415
  348
20
Apparent motor current < current
threshold (DCTRL1−IMOT<ILIM)
V−belt monitoring
Apparent motor current = C0054
Current threshold = C0156
Frequency threshold Q
min
= C0017
21
Apparent motor current < current
threshold and output frequency >
Frequency threshold Q
min
(DCTRL1−(IMOT<ILIM)−QMIN)
22
Apparent motor current < current
threshold and ramp function generator
1: input = output
(DCTRL1−(IMOT<ILIM)−RFG−I=0)
23
Motor phase failure warning
(DCTRL1−LP1−WARN)
Set C0597 = 2
24
Min. output frequency reached
(f  C0010) (PCTRL1−NMIN)
LOW active
25
TRIP error message (DCTRL1−TRIP)
26
Motor is running (DCTRL1−RUN)
27
Motor is running / CW rotation
(DCTRL1−RUN−CW)
28
Motor is running / CCW rotation
(DCTRL1−RUN−CCW)
29
Process controller input = process
controller output (PCTRL1−SET=ACT)
30
Reserved
31
Apparent motor current 
>
Current
threshold and ramp function generator
1: input = output
(DCTRL1−(IMOT>ILIM)−RFG−I=0)
Overload monitoring
Apparent motor current = C0054
Current threshold = C0156
32
Digital input X3/E1
Digital inputs
33
Digital input X3/E2
34
Digital input X3/E3
35
Digital input X3/E4
36 (A)
Digital input X3/E5
37 (A)
Digital input X3/E6
38
PTC input X2.2/T1, X2.2/T2
Only connect potential−free
switches to T1/T2!
T1/T2 is active ("HIGH") when the
switch is closed
Function library
Code table
10
420
EDS82EV903  EN  3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0415
(Cont.)
Possible digital signals for C0415
  343
AIF control word (AIF−CTRL)
Permanently assigned bits of
AIF−CTRL:
Bit 3: QSP
Bit 7: CINH
Bit 10: TRIP−SET
Bit 11: TRIP−RESET
40
Bit 0
...
...
55
Bit 15
CAN−IN1.W1 or FIF−IN.W1
60
Bit 0
...
...
75
Bit 15
CAN−IN1.W2 or FIF−IN.W2
80
Bit 0
...
...
95
Bit 15
CAN−IN2.W1
100
Bit 0
...
...
115
Bit 15
CAN−IN2.W2
120
Bit 0
...
...
135
Bit 15
Status application I/O
Only active for operation with
application I/O
140
Torque threshold 1 reached
(MSET1=MOUT)
141
Torque threshold 2 reached
(MSET2=MOUT)
142
Limitation of process controller output
reached (PCTRL1−LIM)
143...1
72
Reserved
255
Not assigned (FIXED−FREE)
C0416
Level inversion
− digital
outputs
0
0
Level inversion switched off
By entering the sum of the
selected values you can invert
several outputs.
  348
1
Relay K1 1 or digital switching output
K1 2
1: applies to version 151
2: applies to version 152
2
X3/A1
4
X3/A2
Only application I/O
8
Relay K2
Relay output K2 only with
8200 vector 15 ... 90 kW