TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered.  If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
• Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.
• All electronic components have 120 volt ac and low voltage dc potential on their terminals.  Shorting of
terminals or the application of external voltages may result in board failure.
• Intermittent operation of electronic circuit boards is unlikely.  Board failure will normally be permanent.  If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
• Solenoid removal requires interrupting the water supply to the valve.  Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
• The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened.  This will help
to avoid twists and kinks in the tubing.
• Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
• This brewer is heated at all times.  Keep away from combustibles.
WARNING – • Exercise extreme caution when servicing electrical equipment.
• Unplug the brewer when servicing, except when electrical tests are specified.
• Follow recommended service procedures.
• Replace all protective shields or safety notices.
Before troubleshooting this brewer, check for the following:
Control Boards
1. Make sure ribbon cable is properly attached to the control board (ALL PINS INSERTED INTO PLUG).
2. Make sure there is a nylon insulating washer under each screw head that holds the control board to the plastic
front end cap. This is important for proper operation.
3. Make sure before servicing brewer that voltage is present at control board.
4. Press any warmer switch or observe if any indicator lights are glowing on the control panel. If so, proceed
with testing. If not, check for voltage across pins 1 & 2 of the ten pin J1 connector (black and white wires). If
voltage is present, replace the control board. If voltage is not present, check wiring and voltage across terminal
block (black and white). Correct the problem and retest before proceeding with testing.
35582 041503
Add text to pdf document in preview - insert text into PDF content in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
XDoc.PDF for .NET, providing C# demo code for inserting text to PDF file
add text pdf; how to add a text box in a pdf file
Add text to pdf document in preview - VB.NET PDF insert text library: insert text into PDF content in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Providing Demo Code for Adding and Inserting Text to PDF File Page in VB.NET Program
add text to pdf acrobat; how to add text to a pdf in preview
Page 12
Will not fill or refill
PROBABLE CAUSE
REMEDY
PROBLEM
1. Power off to brewer
2. Water shut off
3. Display flashing
4. ON/OFF Switch
5. Lime build up on Probe
6. Refill Valve or Control Board
7.  Water  is  too  conductive  for
proper operation when using the
factory setting of sensing thresh-
old.
Press warmer switches on control
panel to determine if power is ON.
Make sure water is ON.
Brewer  has  shut  down  due  to
malfunction (See Diagnostic Chart
in manual, Page 21, or under top
lid of brewer).
Make sure ON/OFF Switch is "ON"
and indicator is lit.
Remove the Probe and check for
lime  deposit  on  tip. Clean  and
reinstall.
Disconnect the brewer from the
power source and remove wires
from refill valve coil. Check for
continuity across the terminals of
the solenoid coil. If continuity is
not present, replace the refill valve
(See  page  29).  If  continuity  is
present,  the  coil may  be stuck
closed. Shut water off to brewer.
Set the ON/OFF switch to the "OFF"
position. Open the faucet and drain
water down in the tank until flow
stops or slows to a trickle. Attach
a voltmeter to the terminals of the
refill solenoid. Connect the brewer
to the power source. Press the
switch "ON". Within five seconds,
voltage should be present at the
solenoid terminals. If voltage is
not present, refer to the  wiring
diagrams and check the wiring
harness.
TROUBLESHOOTING (cont.)
REFILL CIRCUIT
Reset the 
Water Sensing Thresh-
old Adjustment Procedures
on
page 9.
35582 041503
How to C#: Preview Document Content Using XDoc.Word
With the SDK, you can preview the document content according to the preview thumbnail by the ways as following. C# DLLs for Word File Preview. Add references:
how to add text to pdf file with reader; how to add text box to pdf
How to C#: Preview Document Content Using XDoc.PowerPoint
C# DLLs: Preview PowerPoint Document. Add necessary XDoc.PowerPoint DLL libraries into your created C# application as references. RasterEdge.Imaging.Basic.dll.
add text field to pdf; adding text to a pdf form
Page 13
TROUBLESHOOTING (cont.)
Fill or refill does not shut "OFF"
(ON/OFF Switch "ON")
Fill or refill does not shut "OFF"
(ON/OFF Switch "OFF")
PROBABLE CAUSE
REMEDY
PROBLEM
1. Lime build up on probe
2. Water Level Probe Sensing Sys-
tem
3. Refill valve or control board
4.  Water  is  too  conductive  for
proper operation when using the
factory setting of sensing thresh-
old.
1. Refill valve or control board
Remove Probe and check for lime
deposits on tip. Clean and reinstall.
Disconnect the brewer from the
power source. Disconnect the J3
connector from the control board.
Check for continuity from the nut
on top of the level probe to pin 1 of
the  plug,  continuity  should  be
present.  Pull  the  temperature
probe up about an inch from the
grommet.  Check  for  continuity
from the outside surface of the
temperature probe and pin 4 of the
plug, continuity should be present.
Connect the J3 plug to the control
board and proceed to step 3.
Press ON/OFF switch to "ON" (In-
dicator lamp should be lit). If wa-
ter continuously flows out of air
vent tube, disconnect the brewer
from the power source. If water
flow  stops,  replace  the  control
board. If water flow does not stop,
repair or replace the refill sole-
noid. (See page 29)
Reset the 
Water Sensing Thresh-
old Adjustment Procedures
on
page 9.
If water continuously flows out of
air  vent  tube,  disconnect  the
brewer from the power source. If
water flow does not stop, repair or
replace the refill solenoid. If the
valve closes when power is re-
moved, replace the control board.
(See page 23)
REFILL CIRCUIT (cont.)
35582 091503
C# WinForms Viewer: Load, View, Convert, Annotate and Edit PDF
Highlight PDF text. • Add text to PDF document in preview. • Add text box to PDF file in preview. • Draw PDF markups. PDF Protection.
how to insert text in pdf reader; add editable text box to pdf
C# WPF Viewer: Load, View, Convert, Annotate and Edit PDF
PDF Annotation. • Add sticky notes to PDF document. • Highlight PDF text in preview. • Add text to PDF document. • Insert text box to PDF file.
how to add text field to pdf form; how to insert a text box in pdf
Page 14
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
HEATING CIRCUIT
1. Display flashing
2. Water not touching tempera-
ture probe
3. Dry Plug In Probe Sensing Sys-
tem
Brewer has shut down due to mal-
function (See Diagnostic Chart in
manual, Page 21, or under top lid).
Remove probe and grommet. Look
into hole on tank lid. Water must
be within one inch from top of
tank.
Disconnect the brewer from the
power source. Disconnect the J3
connector from the control board.
Check for continuity from the tank
mounting screw where the green
wire mounts,  to pin 2 of the plug,
continuity should be present. Pull
the temperature probe up about
an inch from the grommet. Check
for  continuity  from  the  outside
surface of the temperature probe
and pin 4 of the plug, continuity
should be present. Connect the J3
plug to the control board and pro-
ceed to step 4.
Water  does  not heat  to  proper
temperature
IMPORTANT: Make sure no tem-
perature tests are taken before the
ready light is "ON". Tank tempera-
ture must be stabilized before read-
ings are taken.
35582 091503
VB.NET PDF File Compress Library: Compress reduce PDF size in vb.
target PDF document file. Remove bookmarks, annotations, watermark, page labels and article threads from PDF while compressing. Also a preview component enables
adding text to a pdf in reader; adding text to pdf form
VB.NET PDF insert image library: insert images into PDF in vb.net
try with this sample VB.NET code to add an image As String = Program.RootPath + "\\" 1.pdf" Dim doc New PDFDocument(inputFilePath) ' Get a text manager from
add text to pdf file reader; how to add text to a pdf file
Page 15
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
Water  does  not heat  to  proper
temperature (cont.)
IMPORTANT: Make sure no tem-
perature tests are taken before the
ready light is "ON". Tank tempera-
ture must be stabilized before read-
ings are taken.
Spitting or excessive steaming
4. Temperature Probe
5. Limit Thermostat
6. Tank Heater
1. Lime build up on temperature
probe, tank or tank heater
Remove the probe from the grom-
met and submerge in a water bath
of approximately 70°F(21°C). Con-
nect an ohmmeter to pins 3 and 4
of the J3 connector. At 60°F(16°C)
the reading should be 15.3k ± 2k
OHMS, at 70°F(21°C) the reading
should be 11.8k ± 2k OHMS, and
at 80°F(27°C) the reading should
be 9.3k ± 2k OHMS. If the probe is
within these parameters, recon-
nect the J3 plug to the  control
board.
Disconnect the brewer from the
power source. Check for continu-
ity across the limit thermostat ter-
minals.  Continuity  should  be
present. If not replace the limit
thermostat.(See page 26)
Disconnect the brewer from the
power source. Check for continu-
ity between the white terminal of
the terminal block (or Red termi-
nal on 208/240 volt models) and
the black wire on the relay on the
control board. There should be a
low OHM reading. If no continuity
is present, check for a wiring prob-
lem, then replace the tank heater if
no wiring problem is found. (See
page 27)
Inspect probe and tank assembly
for excessive lime deposits. Delime
as required.
HEATING CIRCUIT (cont.)
35582 041503
C# PDF insert image Library: insert images into PDF in C#.net, ASP
supports inserting image to PDF in preview without adobe How to insert and add image, picture, digital photo scanned signature or logo into PDF document page in
add text to pdf using preview; add text to pdf in acrobat
How to C#: Preview Document Content Using XDoc.excel
following. C# DLLs: Preview Excel Document without Microsoft Office Installed. Add necessary references: RasterEdge.Imaging.Basic.dll.
add text to pdf document in preview; add text pdf file
Page 16
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
Spitting  or  excessive  steaming
(cont.)
Brewer is making unusual noises
2. Temperature Probe
3. Control Board
1. Plumbing lines
2. Water supply
3. Lime build up
Remove the probe from the grom-
met and submerge in a water bath
of approximately 70°F(21°C). Con-
nect an ohmmeter to pins 3 and 4
of the J3 connector. At 60°F(16°C)
the reading should be 15.3k ± 2k
OHMS, at 70°F(21°Cº the reading
should be 11.8k ± 2k OHMS, and
at 80°F(27°C) the reading should
be 9.3k ± 2k OHMS. If the probe is
within these parameters, recon-
nect the J3 plug to the  control
board.
Set  the  temperature  to  200°F
(93°C). Let tank temperature sta-
bilize.  If  temperature  in tank is
above temperature setting by more
than 7°F(3.9°C), replace the con-
trol board.(See page 23)
Plumbing lines should not rest on
the counter top.
The brewer must be connected to
a cold water supply.
Remove the  tank  lid  and  clean
inside of tank with a deliming agent,
if necessary.
HEATING CIRCUIT (cont.)
35582 041503
Page 17
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
BREWING CIRCUIT
Brew cycle will not start
1. Display flashing
2. No water
3. No power or incorrect voltage to
the brewer
4. ON/OFF switch not in the "ON"
position
5. Low water temperature (Brew
lockout is enabled)
6. Water not touching refill probe
inside tank
7. Switch panel
Brewer  has  shut  down  due  to
malfunction (See Diagnostic Chart
in manual, Page 21, or under top
lid of brewer).
Water  lines  and  valves  to  the
brewer must be open.
Check for voltage across the black
and white terminals at the termi-
nal block.
The indicator lamp must be lit
Allow brewer to heat until ready
lamp is lit, or disable the brew
lockout feature. (See page 8)
Press ON/OFF  switch  (indicator
must be lit). Brewer will refill until
water touches probe inside tank.
Water  must  be  in  contact with
refill probe before brew cycle will
start.
Disconnect the brewer from the
power source. Disconnect the rib-
bon connector from the control
board.  Check for continuity  be-
tween pins 1 & 2 (An arrow on the
connector  indicates  pin  1).  No
continuity should be present. Press
the  BREW  switch.  Continuity
should be present for as long as
the switch is held "ON". If no con-
tinuity  is  present,  replace  the
switch membrane decal.(See page
24)
35582 041503
Page 18
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
BREWING CIRCUIT (cont.)
If the switch panel is operating
properly, proceed as follows. At-
tach a voltmeter to the terminals
of the dispense solenoid. Connect
the brewer to the power source.
Turn on the brewer and press the
BREW switch. Voltage should be
present at the solenoid terminals.
If voltage is not present, refer to
the  wiring diagrams and check
the wiring harness. If voltage is
present,  check  for  continuity
across the terminals of the sole-
noid  coil.  If  continuity  is  not
present, replace the solenoid (See
page 25). If continuity is present,
the valve may be stuck closed.
Set  up brewer according to in-
structions in section  
Adjustments
-
Brew Volumes. (See page 8) Us-
ing a stop watch or second hand,
time the length of the brew cycle.
Record this time inside the top lid.
If service is ever needed again, use
the time as reference to determine
if time has changed.
Inspect  the dispense  valve  and
spray head for excessive lime de-
posits. Delime as required.
Remove dispense valve and clear
any obstructions. Rebuild or re-
place valve if necessary. (See page
25)
8. Control board or dispense valve
1. Brew volume
2. Lime build up
3. Dispense Valve
Brew cycle will not start (cont.)
Consistently low beverage level in
the dispenser or beverage over-
flows dispenser
35582 041503
Page 19
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
BREWING CIRCUIT (cont.)
Dripping from spray head
Weak beverage
1. Lime build up
2. Dispense valve
1. Sprayhead
2. Water temperature
3. Filter type
4. Coffee grind
5. Funnel loading
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
Remove the dispense valve and
clear any obstructions. Rebuild or
replace the valve if necessary.(See
page 25)
A clean spray-head must be used
for proper extraction.
Place an empty brew funnel on an
empty  decanter  beneath  the
sprayhead. Initiate brew cycle and
check the water temperature im-
mediately  below  the  sprayhead
with a thermometer. The reading
must not be less than 195°F(91°C).
Adjust the temperature setting to
increase the water temperature.
Refer to
 Initial Set-up
instructions.
BUNN
®
paper filters must be used
for proper extraction.
A fine drip or grind must be used
for proper extraction.
The BUNN
®
paper filter must be
centered in the funnel and the bed
of  grounds  leveled  by  shaking
gently.
35582 041503
Page 20
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
BREWING CIRCUIT (cont.)
Dry coffee grounds remain in the
funnel
Low beverage serving tempera-
ture
1. Sprayhead
2. Funnel loading
1. Warmer
Make sure sprayhead is present
and  holes  are  clear  and  unob-
structed.
The BUNN
®
paper filter must be
centered in the funnel and the bed
of grounds leveled by shaking gen-
tly.
Disconnect the brewer from the
power source. Remove the warmer
plate and turn upside down to ex-
pose the warmer terminals. Re-
move the two  wires.  Check for
continuity across the two warmer
terminals.  If  continuity  is  not
present, replace the warmer ele-
ment (See page 30). If continuity
is present, reconnect the wires to
the warmer  element. Check for
voltage at the warmer terminals.
Turn the warmer switch "ON". The
indicator light will come on. Volt-
age should be present at the ter-
minals. If not, disconnect power
supply  and  check  wiring  and
switch.
35582 041503
Documents you may be interested
Documents you may be interested