mvc view pdf : Add text to pdf document online Library software class asp.net winforms windows ajax 72T18125L10BB-Integrated-Device-Technology-datasheet-53173821-part1483

11
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
DC ELECTRICAL CHARACTERISTICS
(Commercial: V
CC 
= 2.5V ± 0.125V, T
= 0
°
C to +70
°
C;Industrial: V
CC 
= 2.5V ± 0.125V, T
= -40
°
C to +85
°
C)
Symbol
Parameter
Min.
Max.
Unit
I
LI
Input Leakage Current
–10
10
µ
A
I
LO
Output Leakage Current
–10
10
µ
A
V
OH(5)
Output Logic “1” Voltage,
I
OH
= –8 mA @V
DDQ
= 2.5V 
±
0.125V (LVTTL)
V
DDQ
-0.4
V
I
OH
= –8 mA @V
DDQ
= 1.8V 
±
0.1V (eHSTL)
V
DDQ
-0.4
V
I
OH
= –8 mA @V
DDQ
= 1.5V 
±
0.1V (HSTL)
V
DDQ
-0.4
V
V
OL
Output Logic “0” Voltage,
I
OL
= 8 mA
@V
DDQ
= 2.5V 
±
0.125V (LVTTL)
0.4V
V
I
OL
= 8 mA
@V
DDQ
= 1.8V 
±
0.1V (eHSTL)
0.4V
V
I
OL
= 8 mA
@V
DDQ
= 1.5V 
±
0.1V (HSTL)
0.4V
V
IDT72T1845/72T1855/72T1865/72T1875/72T1885/72T1895
I
CC1(1,2)
Active V
CC
Current (V
CC
= 2.5V)
I/O = LVTTL
40
mA
I/O = HSTL
60
mA
I/O = eHSTL
60
mA
I
CC2(1)
Standby V
CC
Current (V
CC
= 2.5V) I/O = LVTTL
10
mA
I/O = HSTL
50
mA
I/O = eHSTL
50
mA
IDT72T18105/72T18115/72T18125
I
CC1(1,2)
Active V
CC
Current (V
CC
= 2.5V)
I/O = LVTTL
50
mA
I/O = HSTL
70
mA
I/O = eHSTL
70
mA
I
CC2(1)
Standby V
CC
Current (V
CC
= 2.5V) I/O = LVTTL
20
mA
I/O = HSTL
60
mA
I/O = eHSTL
60
mA
NOTES:
1. Both WCLK and RCLK toggling at 20MHz. Data inputs toggling at 10MHz. 
WCS
= HIGH, 
REN
or 
RCS
= HIGH.
2. For  the IDT72T18105/72T18115/72T18125, typical I
CC1 
calculation  (with  data outputs  in  Low-Impedance)
:
for LVTTL I/O I
CC1
(mA) = 1.0 x fs, fs = WCLK = RCLK frequency (in MHz)
for HSTL or eHSTL I/O I
CC1
(mA) = 30 + (1.0 x fs), fs = WCLK = RCLK frequency (in MHz)
For  the  IDT72T1845/72T1855/72T1865/72T1875/72T1885/72T1895,  typical  I
CC1 
calculation  (with  data  outputs  in  Low-Impedance)
:
for LVTTL I/O I
CC1
(mA) = 0.7mA x fs, fs = WCLK = RCLK frequency (in MHz)
for HSTL or eHSTL I/O I
CC1
(mA) = 30 + (0.7 x fs), fs = WCLK = RCLK frequency (in MHz).
3. For all  devices, typical I
DDQ 
calculation: with data outputs in High-Impedance: I
DDQ 
(mA) = 0.15 x fs, fs = WCLK = RCLK frequency (in MHz)
with data outputs in Low-Impedance: I
DDQ 
(mA) = (C
x V
DDQ 
x fs
x N)/2000
fs = WCLK = RCLK frequency (in MHz), V
DDQ 
= 2.5V for LVTTL; 1.5V for HSTL; 1.8V for eHSTL, C
L
= capacitive load (pf), t
A
= 25°C,
N=  Number  of outputs  switching.
4. Total Power consumed: PT = (V
CC
x I
CC
) + V
DDQ
x I
DDQ
).
5. Outputs are not 3.3V tolerant.
Add text to pdf document online - insert text into PDF content in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
XDoc.PDF for .NET, providing C# demo code for inserting text to PDF file
how to insert text box on pdf; add text to pdf using preview
Add text to pdf document online - VB.NET PDF insert text library: insert text into PDF content in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Providing Demo Code for Adding and Inserting Text to PDF File Page in VB.NET Program
adding text to pdf; add text to pdf acrobat
12
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
AC ELECTRICAL CHARACTERISTICS
(1)
⎯ SYNCHRONOUS TIMING
(Commercial: V
CC 
= 2.5V 
±
5%, T
= 0
°
C to +70
°
C;Industrial: V
CC 
= 2.5V 
±
5%, T
= -40
°
C to +85
°
C)
NOTES:
1. All AC timings apply to both Standard IDT mode and First Word Fall Through mode.
2. Industrial temperature range product for the 5ns speed grade is available as a  standard device. All other speed grades are available by special order.
3. Pulse  widths less than  minimum values are not allowed.
4. Values guaranteed by  design, not currently tested.
Commercial
Com’l & Ind’l
(2)
Commercial
Commercial
IDT72T1845L4-4
IDT72T1845L5
IDT72T1845L6-7
IDT72T1855L4-4
IDT72T1855L5
IDT72T1855L6-7
IDT72T1865L4-4
IDT72T1865L5
IDT72T1865L6-7
IDT72T1875L4-4
IDT72T1875L5
IDT72T1875L6-7
IDT72T1885L4-4
IDT72T1885L5
IDT72T1885L6-7
IDT72T1895L4-4
IDT72T1895L5
IDT72T1895L6-7
IDT72T18105L4-4 IDT72T18105L5 IDT72T18105L6-7 IDT72T18105L10
IDT72T18115L4-4 IDT72T18115L5 IDT72T18115L6-7 IDT72T18115L10
IDT72T18125L4-4 IDT72T18125L5 IDT72T18125L6-7 IDT72T18125L10
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Unit
f
C
Clock Cycle Frequency (Synchronous)
225
200
150
100
MHz
t
A
Data Access Time
0.6
3.4
0.6
3.6
0.6
3.8
0.6
4.5
ns
t
CLK
Clock Cycle Time
4.44
5
6.7
10
ns
t
CLKH
Clock High Time
2.0
2.3
2.8
4.5
ns
t
CLKL
Clock Low Time
2.0
2.3
2.8
4.5
ns
t
DS
Data Setup Time
1.2
1.5
2.0
3.0
ns
t
DH
Data Hold Time
0.5
0.5
0.5
0.5
ns
t
ENS
Enable Setup Time
1.2
1.5
2.0
3.0
ns
t
ENH
Enable Hold Time
0.5
0.5
0.5
0.5
ns
t
LDS
Load Setup Time
1.2
1.5
2.0
3.0
ns
t
LDH
Load Hold Time
0.5
0.5
0.5
0.5
ns
t
WCSS
WCS 
setup time
1.2
1.5
2.0
3.0
ns
t
WCSH
WCS 
hold time
0.5
0.5
0.5
0.5
ns
f
S
Clock Cycle Frequency (SCLK)
10
10
10
10
MHz
t
SCLK
Serial Clock Cycle
100
100
100
100
ns
t
SCKH
Serial Clock High
45
45
45
45
ns
t
SCKL
Serial Clock Low
45
45
45
45
ns
t
SDS
Serial Data In Setup
15
15
15
15
ns
t
SDH
Serial Data In Hold
5
5
5
5
ns
t
SENS
Serial Enable Setup
5
5
5
5
ns
t
SENH
Serial Enable Hold
5
5
5
5
ns
t
RS
Reset Pulse Width
(3)
30
30
30
30
ns
t
RSS
Reset Setup Time
15
15
15
15
ns
t
HRSS
HSTL Reset Setup Time
4
4
4
4
µ
s
t
RSR
Reset Recovery Time
10
10
10
10
ns
t
RSF
Reset to Flag and Output Time
10
12
15
15
ns
t
WFF
Write Clock to 
FF
or 
IR
3.4
3.6
3.8
4.5
ns
t
REF
Read Clock to 
EF
or 
OR
3.4
3.6
3.8
4.5
ns
t
PAFS
Write Clock to Synchronous Programmable Almost-Full Flag
3.4
3.6
3.8
4.5
ns
t
PAES
Read Clock to Synchronous Programmable Almost-Empty Flag
3.4
3.6
3.8
4.5
ns
t
ERCLK
RCLK to Echo RCLK output
3.8
4
4.3
5
ns
t
CLKEN
RCLK to Echo 
REN
output
3.4
3.6
3.8
4.5
ns
t
RCSLZ
RCLK to Active from High-Z
(4)
3.4
3.6
3.8
4.5
ns
t
RCSHZ
RCLK to High-Z
(4)
3.4
3.6
3.8
4.5
ns
t
SKEW1
Skew time between RCLK and WCLK for 
EF
/
OR
and 
FF
/
IR
3.5
4
5
7
ns
t
SKEW2
Skew time between RCLK and WCLK for 
PAE
and 
PAF
4
5
6
8
ns
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
Protect. Password: Set File Permissions. Password: Open Document. Edit Digital Highlight Text. Add Text. Add Text Box. Drawing Markups. PDF Print. Work with
how to insert a text box in pdf; how to add text field to pdf
VB.NET PDF insert image library: insert images into PDF in vb.net
try with this sample VB.NET code to add an image As String = Program.RootPath + "\\" 1.pdf" Dim doc New PDFDocument(inputFilePath) ' Get a text manager from
adding text to a pdf form; how to insert text in pdf file
13
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
AC ELECTRICAL CHARACTERISTICS ⎯ ASYNCHRONOUS TIMING
(Commercial: V
CC 
= 2.5V 
±
5%, T
= 0
°
C to +70
°
C;Industrial: V
CC 
= 2.5V 
±
5%, T
= -40
°
C to +85
°
C)
Commercial
Com’l & Ind’l
(2)
Commercial
Commercial
IDT72T1845L4-4
IDT72T1845L5
IDT72T1845L6-7
IDT72T1855L4-4
IDT72T1855L5
IDT72T1855L6-7
IDT72T1865L4-4
IDT72T1865L5
IDT72T1865L6-7
IDT72T1875L4-4
IDT72T1875L5
IDT72T1875L6-7
IDT72T1885L4-4
IDT72T1885L5
IDT72T1885L6-7
IDT72T1895L4-4
IDT72T1895L5
IDT72T1895L6-7
IDT72T18105L4-4 IDT72T18105L5 IDT72T18105L6-7 IDT72T18105L10
IDT72T18115L4-4 IDT72T18115L5 IDT72T18115L6-7 IDT72T18115L10
IDT72T18125L4-4 IDT72T18125L5 IDT72T18125L6-7 IDT72T18125L10
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Unit
f
A
Cycle Frequency (Asynchronous)
100
83
66
50
MHz
t
AA
Data Access Time
0.6
8
0.6
10
0.6
12
0.6
14
ns
t
CYC
Cycle Time
10
12
15
20
ns
t
CYH
Cycle HIGH Time
4.5
5
7
8
ns
t
CYL
Cycle LOW Time
4.5
5
7
8
ns
t
RPE
Read Pulse after 
EF
HIGH
8
10
12
14
ns
t
FFA
Clock to Asynchronous 
FF
8
10
12
14
ns
t
EFA
Clock to Asynchronous 
EF
8
10
12
14
ns
t
PAFA
Clock to Asynchronous Programmable Almost-Full Flag
8
10
12
14
ns
t
PAEA
Clock to Asynchronous Programmable Almost-Empty Flag
8
10
12
14
ns
t
OLZ
Output Enable to Output in Low Z
(3)
0
0
0
0
ns
t
OE
Output Enable to Output Valid
3.4
3.6
3.8
4.5
ns
t
OHZ
Output Enable to Output in High Z
(3)
3.4
3.6
3.8
4.5
ns
t
HF
Clock to 
HF
8
10
12
14
ns
NOTES:
1. All AC timings apply to both Standard IDT mode and First Word Fall Through mode.
2. Industrial  temperature range product for  the 5ns speed grade is available as a standard device. All other speed grades are available by special order.
3. Values guaranteed  by  design, not  currently  tested.
DocImage SDK for .NET: Web Document Image Viewer Online Demo
on the client side without additional add-ins and Microsoft PowerPoint: PPTX, PPS, PPSX; PDF: Portable Document HTML5 Document Viewer Developer Guide. To see
add text to pdf file online; adding text fields to a pdf
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
Protect. Password: Set File Permissions. Password: Open Document. Edit Digital Highlight Text. Add Text. Add Text Box. Drawing Markups. PDF Print. Work with
how to insert text in pdf using preview; add text to pdf document in preview
14
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
Input Pulse Levels
0.25 to 1.25V
Input Rise/Fall Times
0.4ns
Input Timing Reference Levels
0.75
Output Reference Levels
V
DDQ
/2
HSTL
1.5V AC TEST CONDITIONS
Figure 2b. Lumped Capacitive Load, Typical Derating
AC TEST LOADS
Figure 2a. AC Test Load
Input Pulse Levels
0.4 to 1.4V
Input Rise/Fall Times
0.4ns
Input Timing Reference Levels
0.9
Output Reference Levels
V
DDQ
/2
EXTENDED HSTL
1.8V AC TEST CONDITIONS
Input Pulse Levels
GND to 2.5V
Input Rise/Fall Times
1ns
Input Timing Reference Levels
V
CC
/2
Output Reference Levels
V
DDQ
/2
2.5V LVTTL
2.5V AC TEST CONDITIONS
5909 drw04
50
V
DDQ
/2
I/O
Z
0
= 50
5909 drw04a
6
5
4
3
2
1
20 30 50
80 100
200
Capacitance (pF)
tCD
(Typical, ns)
NOTE:
1. V
DDQ
= 1.5V±.
NOTE:
1. V
DDQ
= 1.8V±.
NOTE:
1. For LVTTL V
CC
= V
DDQ
.
VB.NET PDF Password Library: add, remove, edit PDF file password
allowed. passwordSetting.IsCopy = True ' Allow to assemble document. passwordSetting.IsAssemble = True ' Add password to PDF file.
how to add text field to pdf form; add text to pdf without acrobat
C# HTML5 PDF Viewer SDK to annotate PDF document online in C#.NET
versions. Users can add sticky note to PDF document. Able to Highlight PDF text. Able to underline PDF text with straight line. Support
how to enter text into a pdf form; adding text box to pdf
15
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
OUTPUT ENABLE & DISABLE TIMING
V
IH
OE
V
IL
t
OE &
t
OLZ
V
CC
2
V
CC
2
100mV
100mV
t
OHZ
100mV
100mV
Output
Normally
LOW
Output
Normally
HIGH
V
OL
V
OH
V
CC
2
V
CC
2
5909 drw04b
Output
Enable
Output
Disable
READ CHIP SELECT ENABLE & DISABLE TIMING
VIH
RCS
VIL 
t
ENS
t
ENH
t
RCSLZ
RCLK
V
CC
2
V
CC
2
100mV
100mV
t
RCSHZ
100mV
100mV
Output
Normally
LOW
Output
Normally
HIGH
VOL
VOH 
V
CC
2
V
CC
2
5909 drw04c
NOTES:
1.
REN
is HIGH.
2.
RCS
is LOW.
NOTES:
1.
REN
is HIGH.
2.
OE
is LOW.
VB.NET PDF Text Extract Library: extract text content from PDF
NET programming language, you may use this PDF Document Add-On for With this advanced PDF Add-On, developers are able to extract target text content from
add text box in pdf document; add text pdf professional
C# PDF Text Extract Library: extract text content from PDF file in
How to C#: Extract Text Content from PDF File. Add necessary references: RasterEdge.Imaging.Basic.dll. RasterEdge.Imaging.Basic.Codec.dll.
how to add text to pdf; add text to pdf document online
16
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
FUNCTIONAL DESCRIPTION
TIMING MODES: IDT STANDARD vs FIRST WORD FALL THROUGH
(FWFT) MODE
The  IDT72T1845/72T1855/72T1865/72T1875/72T1885/72T1895/
72T18105/72T18115/72T18125 support two different timing modes of opera-
tion: IDT Standard mode or First Word Fall Through (FWFT) mode. The
selection of which mode will operate is determined during Master Reset, by the
state of the FWFT/SI input.
If, at the time of Master Reset, FWFT/SI is LOW, then IDT Standard mode
will be selected. This mode uses the Empty Flag (
EF
) to indicate whether or not
there are any words present in the FIFO. It also uses the Full Flag function (
FF
)
to indicate whether or not the FIFO has any free space for writing. In IDT
Standard mode, every word read from the FIFO, including the first, must be
requested using the Read Enable (
REN
) and RCLK.
If, at the time of Master Reset, FWFT/SI is HIGH, then FWFT mode will be
selected. This mode uses Output Ready (
OR
) to indicate whether or not there
is valid data at the data outputs (Q
n)
. It also uses Input Ready (
IR
) to indicate
whether or not the FIFO has any free space for writing. In the FWFT mode, the
first word written to an empty FIFO goes directly to Q
n
after three RCLK rising
edges, 
REN
= LOW is not necessary. Subsequent words must be accessed
using the Read Enable (
REN
) and RCLK.
Various signals, both input and output signals operate differently depending
on which timing mode is in effect.
IDT STANDARD MODE
In this mode, the status flags, 
FF
PAF
HF
PAE
, and 
EF
operate in the
manner outlined in Table 3. To write data into to the FIFO, Write Enable (
WEN
)
must be LOW. Data presented to the DATA IN lines will be clocked into the FIFO
on subsequent transitions of the Write Clock (WCLK). After the first write is
performed, the Empty Flag (
EF
) will go HIGH. Subsequent writes will continue
to fill up the FIFO. The Programmable Almost-Empty flag (
PAE
) will go HIGH
after n + 1 words have been loaded into the FIFO, where n is the empty offset
value. The default setting for these values are stated in the footnote of Table 2.
This parameter is also user programmable. See section on Programmable Flag
Offset Loading.
If one continued to write data into the FIFO, and we assumed no read
operations were taking place, the Half-Full flag (
HF
) would toggle to LOW once
(D/2 + 1) words were written into the FIFO. If x18 Input or x18 Output bus Width
is selected, (D/2 + 1) = the 1,025th word for the IDT72T1845, 2,049th word for
IDT72T1855, 4,097th word for the IDT72T1865, 8,193rd word  for the
IDT72T1875, 16,385th word for the IDT72T1885, 32,769th word for the
IDT72T1895, 65,537th word for the IDT72T18105, 131,073rd word for the
IDT72T18115 and 262,145th word for the IDT72T18125. If both x9 Input and
x9 Output bus Widths are selected, (D/2 + 1) = the 2,049th word for the
IDT72T1845, 4,097th word for IDT72T1855, 8,193rd word for the IDT72T1865,
16,385th word for the IDT72T1875, 32,769th word for the IDT72T1885,
65,537th word for the IDT72T1895, 131,073rd word for the IDT72T18105,
262,145th word for the IDT72T18115 and 524,289th word for the IDT72T18125.
Continuing to write data into the FIFO will cause the Programmable Almost-Full
flag (
PAF
) to go LOW. Again, if no reads are performed, the 
PAF
will go LOW
after (D-m) writes to the FIFO. If x18 Input or x18 Output bus Width is selected,
(D-m) = (2,048-m) writes for the IDT72T1845, (4,096-m) writes for the
IDT72T1855, (8,192-m) writes for the IDT72T1865, (16,384-m) writes for the
IDT72T1875, (32,768-m) writes for the IDT72T1885, (65,536-m) writes for the
IDT72T1895, (131,072-m) writes for the IDT72T18105, (262,144-m) writes
for the IDT72T18115 and (524,288-m) writes for the IDT72T18125. If both x9
Input and x9 Output bus Widths are selected, (D-m) = (4,096-m) writes for the
IDT72T1845, (8,192-m) writes for the IDT72T1855, (16,384-m) writes for the
IDT72T1865, (32,768-m) writes for the IDT72T1875, (65,536-m) writes for the
IDT72T1885, (131,072-m) writes for the IDT72T1895, (262,144-m) writes for
the IDT72T18105, (524,288-m) writes for the IDT72T18115 and (1,048,576-m)
writes for the IDT72T18125. The offset “m” is the full offset value. The default
setting for these values are stated in the footnote of Table 2. This parameter is
also user programmable. See section on Programmable Flag Offset Loading.
When the FIFO is full, the Full Flag (
FF
) will go LOW, inhibiting further write
operations. If no reads are performed after a reset, 
FF
will go LOW after D writes
to the FIFO. If the x18 Input or x18 Output bus Width is selected, D = 2,048 writes
for the IDT72T1845, 4,096 writes for the IDT72T1855, 8,192 writes for the
IDT72T1865, 16,384 writes for the IDT72T1875, 32,768 writes for the
IDT72T1885, 65,536 writes for the IDT72T1895, 131,072 writes for the
IDT72T18105, 262,144 writes for the IDT72T18115 and 524,288 writes for the
IDT72T18125. If both x9 Input and x9 Output bus Widths are selected, D = 4,096
writes for the IDT72T1845, 8,192 writes for the IDT72T1855, 16,384 writes for
the IDT72T1865, 32,768 writes for the IDT72T1875, 65,536 writes for the
IDT72T1885, 131,072 writes for the IDT72T1895, 262,144 writes for the
IDT72T18105, 524,288 writes for the IDT72T18115 and 1,048,576 writes for
the IDT72T18125, respectively.
If the FIFO is full, the first read operation will cause 
FF
to go HIGH.
Subsequent read operations will cause 
PAF
and 
HF
to go HIGH at the conditions
described in Table 3. If further read operations occur, without write operations,
PAE
will go LOW when there are n words in the FIFO, where n is the empty
offset value. Continuing read operations will cause the FIFO to become empty.
When the last word has been read from the FIFO, the 
EF
will go LOW inhibiting
further read operations. 
REN
is ignored when the FIFO is empty.
When configured in IDT Standard mode, the 
EF
and 
FF
outputs are double
register-buffered outputs.
Relevant timing diagrams for IDT Standard mode can be found in Figure
11, 12, 13 and 18.
FIRST WORD FALL THROUGH MODE (FWFT)
In this mode, the status flags, 
IR
PAF
HF
PAE
, and 
OR
operate in the
manner outlined in Table 4. To write data into to the FIFO, 
WEN
must be LOW.
Data presented to the DATA IN lines will be clocked into the FIFO on subsequent
transitions of WCLK. After the first write is performed, the Output Ready (
OR
)
flag will go LOW. Subsequent writes will continue to fill up the FIFO. 
PAE
will go
HIGH after n + 2 words have been loaded into the FIFO, where n is the empty
offset value. The default setting for these values are stated in the footnote of
Table 2. This parameter is also user programmable. See section on Program-
mable Flag Offset Loading.
If one continued to write data into the FIFO, and we assumed no read
operations were taking place, the 
HF
would toggle to LOW once the (D/2 + 2)
words were written into the FIFO. If x18 Input or x18 Output bus Width is selected,
(D/2 +  2) = the 1,026th word for the IDT72T1845, 2,050th word for IDT72T1855,
4,098th word for the IDT72T1865, 8,194th word for the IDT72T1875, 16,386th
word for the IDT72T1885, 32,770th word for the IDT72T1895, 65,538th word
for the IDT72T18105, 131,074th word for the IDT72T18115 and 262,146th
word for the IDT72T18125. If both x9 Input and x9 Output bus Widths are
selected, (D/2 + 2) = the 2,050th word for the IDT72T1845, 4,098th word for
IDT72T1855, 8,194th word for the IDT72T1865, 16,386th word for the
IDT72T1875, 32,770th word for the IDT72T1885, 65,538th word for the
IDT72T1895, 131,074th word for the IDT72T18105, 262,146th word for the
IDT72T18115 and 524,290th word for the IDT72T18125. Continuing to write
data into the FIFO will cause the 
PAF
to go LOW. Again, if no reads are
performed, the 
PAF
will go LOW after (D-m) writes to the FIFO. If x18 Input or
x18 Output bus Width is selected, (D-m) = (2,049-m) writes for the IDT72T1845,
C# PDF insert image Library: insert images into PDF in C#.net, ASP
freeware download and online C#.NET class source code. How to insert and add image, picture, digital photo, scanned signature or logo into PDF document page in
add text field to pdf; add text pdf acrobat professional
C# PDF Password Library: add, remove, edit PDF file password in C#
in C#.NET framework. Support to add password to PDF document online or in C#.NET WinForms for PDF file protection. Able to create a
add text field to pdf; add text to pdf using preview
17
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
IDT72T18125. If both x9 Input and x9 Output bus Widths are selected, D = 4,097
writes for the IDT72T1845, 8,193 writes for the IDT72T1855, 16,385 writes
for the IDT72T1865, 32,769 writes for the IDT72T1875, 65,537 writes for the
IDT72T1885, 131,073 writes for the IDT72T1895, 262,145 writes for the
IDT72T18105, 524,289 writes for the IDT72T18115 and 1,048,577 writes for
the IDT72T18125, respectively. Note that the additional word in FWFT mode
is due to the capacity of the memory plus output register.
If the FIFO is full, the first read operation will cause the 
IR
flag to go LOW.
Subsequent read operations will cause the 
PAF
and 
HF
to go HIGH at the
conditions described in Table 4. If further read operations occur, without write
operations, the 
PAE
will go LOW when there are n + 1 words in the FIFO, where
n is the empty offset value. Continuing read operations will cause the FIFO to
become empty. When the last word has been read from the FIFO, 
OR
will go
HIGH inhibiting further read operations.
REN
is ignored when the FIFO is
empty.
When configured in FWFT mode, the 
OR
flag output is triple register-
buffered, and the 
IR
flag output is double register-buffered.
Relevant timing diagrams for FWFT mode can be found in Figure 14, 15,
16 and 19.
PROGRAMMING FLAG OFFSETS
Full and Empty Flag offset values are user programmable. The IDT72T1845/
72T1855/72T1865/72T1875/72T1885/72T1895/72T18105/72T18115/
72T18125 have internal registers for these offsets. There are eight default offset
values selectable during Master Reset. These offset values are shown in Table
2. Offset values can also be programmed into the FIFO in one of two ways; serial
or parallel loading method. The selection of the loading method is done using
the 
LD
(Load) pin. During Master Reset, the state of the 
LD
input determines
whether serial or parallel flag offset programming is enabled. A HIGH on 
LD
during Master Reset selects serial loading of offset values. A LOW on 
LD
during
Master Reset selects parallel loading of offset values.
In addition to loading offset values into the FIFO, it is also possible to read
the current offset values. Offset values can be read via the parallel output port
Q
0
-Qn, regardless of the programming mode selected (serial or parallel). It is
not possible to read the offset values in serial fashion.
Figure 3, Programmable Flag Offset Programming Sequence, summaries
the control pins and sequence for both serial and parallel programming modes.
For a more detailed description, see discussion that follows.
The offset registers may be programmed (and reprogrammed) any time
after Master Reset, regardless of whether serial or parallel programming has
been selected. Valid programming ranges are from 0 to D-1.
SYNCHRONOUS  vs  ASYNCHRONOUS  PROGRAMMABLE  FLAG
TIMING SELECTION
The  IDT72T1845/72T1855/72T1865/72T1875/72T1885/72T1895/
72T18105/72T18115/72T18125 can be configured during the Master Reset
cycle with either synchronous or asynchronous timing for 
PAF
and 
PAE
flags
by use of the PFM pin.
If synchronous 
PAF
/
PAE
configuration is selected (PFM, HIGH during
MRS
), the PAF is asserted and updated on the rising edge of WCLK only and
not RCLK. Similarly, 
PAE
is asserted and updated on the rising edge of RCLK
only and not WCLK. For detail timing diagrams, see Figure 23 for synchronous
PAF
timing and Figure 24 for synchronous 
PAE
timing.
If asynchronous 
PAF
/
PAE
configuration is selected (PFM, LOW during
MRS
), the PAF is asserted LOW on the LOW-to-HIGH transition of WCLK and
PAF
is reset to HIGH on the LOW-to-HIGH transition of RCLK. Similarly, 
PAE
is asserted LOW on the LOW-to-HIGH transition of RCLK. 
PAE
is reset to HIGH
on the LOW-to-HIGH transition of WCLK. For detail timing diagrams, see Figure 25
for asynchronous 
PAF
timing and Figure 26 for asynchronous 
PAE
timing.
(4,097-m) writes for the IDT72T1855, (8,193-m) writes for the IDT72T1865,
(16,385-m) writes for the IDT72T1875, (32,769-m) writes for the IDT72T1885,
(65,536-m) writes for the IDT72T1895, (131,073-m) writes for the IDT72T18105,
(262,145-m) writes for the IDT72T18115 and (524,289-m) writes for the
IDT72T18125. If both x9 Input and x9 Output bus Widths are selected, (D-m)
= (4,097-m) writes for the IDT72T1845, (8,193-m) writes for the IDT72T1855,
(16,385-m) writes for the IDT72T1865, (32,769-m) writes for the IDT72T1875,
(65,537-m) writes for the IDT72T1885, (131,073-m) writes for the IDT72T1895,
(262,145-m)  writes  for  the  IDT72T18105,  (524,289-m)  writes  for  the
IDT72T18115 and (1,048,577-m) writes for the IDT72T18125. The offset m
is the full offset value. The default setting for these values are stated in the footnote
of Table 2.
When the FIFO is full, the Input Ready (
IR
) flag will go HIGH, inhibiting further
write operations. If no reads are performed after a reset, 
IR
will go HIGH after
D writes to the FIFO. If x18 Input or x18 Output bus Width is selected, D = 2,049
writes for the IDT72T1845, 4,097 writes for the IDT72T1855, 8,193 writes for
the IDT72T1865, 16,385 writes for the IDT72T1875, 32,769 writes for the
IDT72T1885, 65,536 writes for the IDT72T1895, 131,073 writes for the
IDT72T18105, 262,145 writes for the IDT72T18115 and 524,289 writes for the
TABLE 2 — DEFAULT PROGRAMMABLE
FLAG OFFSETS
NOTES:
1. n = empty offset for 
PAE
.
2. m = full offset for 
PAF
.
3. As well as selecting serial programming mode, one of the default values will also
be loaded depending on the state of FSEL0 & FSEL1.
4. As well as selecting parallel programming mode, one of the default values will
also be loaded depending on the state of FSEL0 & FSEL1.
IDT72T1845
Offsets n,m
All Other
x9 to x9
*
LD
FSEL1
FSEL0
Modes
Mode
L
H
L
511
511
L
L
H
255
255
L
L
L
127
127
L
H
H
63
63
H
L
L
31
1,023
H
H
L
15
31
H
L
H
7
15
H
H
H
3
7
IDT72T1855, 72T1865, 72T1875, 72T1885,
72T1895, 72T18105, 72T18115, 72T18125
*
LD
FSEL1
FSEL0
Offsets n,m
H
L
L
1,023
L
H
L
511
L
L
H
255
L
L
L
127
L
H
H
63
H
H
L
31
H
L
H
15
H
H
H
7
*
LD
FSEL1
FSEL0
Program Mode
H
X
X
Serial
(3)
L
X
X
Parallel
(4)
*THIS PIN MUST BE HIGH AFTER MASTER RESET TO WRITE
OR READ DATA TO/FROM THE FIFO MEMORY.
18
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
0
1 to n
(1)
(n+1) to 1,024
1,025 to (2048-(m+1))
(2048-m) to 2,047
2,048
0
1 to n
(1)
(n+1) to 2,048
2,049 to (4,096-(m+1))
(4,096-m) to 4,095
4,096
TABLE 3 ⎯ STATUS FLAGS FOR IDT STANDARD MODE
TABLE 4 ⎯ STATUS FLAGS FOR FWFT MODE
FF PAF
HF
PAE EF
H
H
H
L
L
H
H
H
L
H
H
H
H
H
H
H
H
L
H
H
H
L
L
H
H
L
L
L
H
H
5909 drw05
IR
PAF HF PAE OR
L
H
H
L
H
L
H
H
L
L
L
H
H
H
L
L
H
L
H
L
L
L
L
H
L
H
L
L
H
L
Number of
Words in
FIFO
IW = x18 or
OW = x18
IW = OW = x9
IDT72T18105
IDT72T1895
IDT72T18115
IDT72T18125
0
1 to n+1(1)
(n+2) to 32,769
32,770 to (65,537-(m+1))
(65,537-m)   to 65,536
65,537
0
(n+2) to 65,537
65,538 to (131,073-(m+1))
(131,073-m)  to 131,072
131,073
0
(n+2) to 131,073
131,074 to (262,145-(m+1))
262,145
(262,145-m)  to 262,144
IDT72T18105
IDT72T18115
IDT72T18125
IDT72T1895
IDT72T1885
0
(n+2) to 262,145
262,146 to (524,289-(m+1))
(524,289-m)  to 524,288
524,289
0
(n+2) to 524,289
524,290 to (1,048,577-(m+1))
1,048,577
(1,048,577-m)  to 1,048,576
1 to n+1(1)
1 to n+1(1)
1 to n+1(1)
1 to n+1(1)
0
1 to n(1)
(n+1) to 4,096
4,097 to (8,192-(m+1))
(8,192-m)
to 8,191
8,192
0
1 to n
(
1)
(n+1) to 8,192
8,193 to (16,384-(m+1))
(16,384-m)  to 16,383
16,384
Number of
Words in
FIFO
IDT72T1855
IW = x18 or
OW = x18
IW = OW = x9
IDT72T1855
IDT72T1845
IDT72T1865
IDT72T1875
IDT72T1865
IDT72T1875
IDT72T1845
IDT72T1885
0
1 to n
(1)
(n+1) to 16,384
16,385 to (32,768-(m+1))
(32,768-m)  to 32,767
32,768
FF PAF HF PAE EF
H
H
H
L
L
H
H
H
L
H
H
H
H
H
H
H
H
L
H
H
H
L
L
H
H
L
L
L
H
H
Number of
Words in
FIFO
IW = x18 or
OW = x18
IW = OW = x9
IDT72T18105
IDT72T1895
IDT72T18115
IDT72T18125
0
1 to n
(1)
(n+1) to 32,768
32,769 to (65,536-(m+1))
(65,536-m)   to 65,535
65,536
0
1 to n
(1)
(n+1) to 65,536
65,537 to (131,072-(m+1))
(131,072-m)  to 131,071
131,072
0
1 to n(1)
(n+1) to 131,072
131,073 to (262,144-(m+1))
262,144
(262,144-m)  to 262,143
IDT72T18105
IDT72T18115
IDT72T18125
IDT72T1895
IDT72T1885
0
1 to n
(1)
(n+1) to 262,144
262,145 to (524,288-(m+1))
(524,288-m)  to 524,287
524,288
0
1 to n(1)
(n+1) to 524,288
524,289 to (1,048,576-(m+1))
1,048,576
(1,048,576-m)  to 1,048,575
0
(n+2) to 1,025
1,026 to (2049-(m+1))
(2049-m)
to 2,048
2,049
0
(n+2) to 2,049
2,050 to (4,097-(m+1))
(4,097-m) to 4,096
4,097
IR
PAF HF PAE OR
L
H
H
L
H
L
H
H
L
L
L
H
H
H
L
L
H
L
H
L
L
L
L
H
L
H
L
L
H
L
0
(n+2) to 4,097
4,098 to (8,193-(m+1))
(8,193-m)
to 8,192
8,193
0
(n+2) to 8,193
8,194 to (16,385-(m+1))
(16,385-m)
to 16,384
16,385
Number of
Words in
FIFO
IDT72T1855
IW = x18 or
OW = x18
IW = OW = x9
IDT72T1855
IDT72T1845
IDT72T1865
IDT72T1875
IDT72T1865
IDT72T1875
IDT72T1845
IDT72T1885
0
(n+2) to 16,385
16,386 to (32,769-(m+1))
(32,769-m)  to 32,768
32,769
1 to n+1(1)
1 to n+1(1)
1 to n+1(1)
1 to n+1(1)
1 to n+1(1)
NOTE:
1. See table 2 for values for n, m.
NOTE:
1. See table 2 for values for n, m.
2. Number of Words in FIFO = Depth + Output Register.
19
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
Figure 3.  Programmable Flag Offset Programming Sequence
WCLK
RCLK
X
X
X
X
X
X
X
X
LD
0
0
X
1
1
1
0
WEN
0
1
1
0
X
1
1
REN
1
0
1
X
0
1
1
X
SEN
1
1
1
X
X
X
0
No Operation
Write Memory
Read Memory
No Operation
Parallel write to registers:
Serial shift into registers:
Ending with Full Offset (MSB)
I
DT72T1845,
IDT72T1855
IDT72T1865,
IDT72T1875
IDT72T1885,
IDT72T1895
IDT72T18105, IDT72T18115
IDT72T18125
24 bits for the IDT72T1845
26 bits for the IDT72T1855
28 bits for the IDT72T1865
30 bits for the IDT72T1875
32 bits for the IDT72T1885
34 bits for the IDT72T1895
36 bits for the IDT72T18105
38 bits for the IDT72T18115
40 bits for the IDT72T18125
1 bit for each rising SCLK edge
Starting with Empty Offset (LSB)
Serial shift into registers:
Ending with Full Offset (MSB)
22 bits for the IDT72T1845
24 bits for the IDT72T1855
26 bits for the IDT72T1865
28 bits for the IDT72T1875
30 bits for the IDT72T1885
32 bits for the IDT72T1895
34 bits for the IDT72T18105
36 bits for the IDT72T18115
38 bits for the IDT72T18125
1 bit for each rising SCLK edge
Starting with Empty Offset (LSB)
x9 to x9 Mode
All Other Modes
5909 drw06
x18 input
Empty Offset
Full Offset
x18 input
(72T18105/115/125)
Empty Offset (LSB)
Empty Offset (MSB)
Full Offset (LSB)
Full Offset (MSB)
x9 input
Empty Offset (LSB)
Empty Offset (MSB)
Full Offset (LSB)
Full Offset (MSB)
x9 input
(72T1895/105/115/125)
Empty Offset (LSB)
Empty Offset
Empty Offset (MSB)
Full Offset (LSB)
Full Offset
Full Offset (MSB)
Parallel read from registers:
x18 input
Empty Offset
Full Offset
x18 input
(72T18105/115/125)
Empty Offset (LSB)
Empty Offset (MSB)
Full Offset (LSB)
Full Offset (MSB)
x9 input
Empty Offset (LSB)
Empty Offset (MSB)
Full Offset (LSB)
Full Offset (MSB)
x9 input
(72T1895/105/115/125)
Empty Offset (LSB)
Empty Offset
Empty Offset (MSB)
Full Offset (LSB)
Full Offset
Full Offset (MSB)
NOTES:
1. The  programming method  can only be selected at Master Reset.
2. Parallel reading of the  offset registers is always permitted regardless of  which programming method has been selected.
3. The programming sequence applies to both IDT Standard and FWFT modes.
20
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
Figure 3.  Programmable Flag Offset Programming Sequence (Continued)
x9 to x9 Mode
All Other Modes
# of Bits Used:
12 bits for the IDT72T1845
13 bits for the IDT72T1855
14 bits for the IDT72T1865
15 bits for the IDT72T1875
16 bits for the IDT72T1885
17 bits for the IDT72T1895
18 bits for the IDT72T18105
19 bits for the IDT72T18115
20 bits for the IDT72T18125
Note: All unused bits of the
LSB & MSB are don’t care
# of Bits Used:
Note: All unused bits of the
LSB & MSB are don’t care
11 bits for the IDT72T1845
12 bits for the IDT72T1855
13 bits for the IDT72T1865
14 bits for the IDT72T1875
15 bits for the IDT72T1885
16 bits for the IDT72T1895
17 bits for the IDT72T18105
18 bits for the IDT72T18115
19 bits for the IDT72T18125
D/Q8
D/Q0
EMPTY OFFSET REGISTER
1
2
3
4
5
6
7
8
1st Parallel Offset Write/Read Cycle
2nd Parallel Offset Write/Read Cycle
3rd Parallel Offset Write/Read Cycle
4th Parallel Offset Write/Read Cycle
D/Q8
D/Q0
EMPTY OFFSET REGISTER
9
10
11
12
13
14
15
16
D/Q8
D/Q0
FULL OFFSET REGISTER
1
2
3
4
5
6
7
8
D/Q8
D/Q0
EMPTY OFFSET REGISTER
17
5th Parallel Offset Write/Read Cycle
D/Q8
D/Q0
FULL OFFSET REGISTER
9
10
11
12
13
14
15
16
6th Parallel Offset Write/Read Cycle
D/Q8
D/Q0
17
FULL OFFSET REGISTER
IDT72T1895/72T18105/72T18115/72T18125(1)
x9 Bus Width
D/Q8
D/Q0
EMPTY OFFSET REGISTER
1
2
3
4
5
6
7
8
1st Parallel Offset Write/Read Cycle
2nd Parallel Offset Write/Read Cycle
3rd Parallel Offset Write/Read Cycle
D/Q8
D/Q0
EMPTY OFFSET REGISTER
9
10
11
12
13
14
15
16
D/Q8
D/Q0
FULL OFFSET REGISTER
1
2
3
4
5
6
7
8
4th Parallel Offset Write/Read Cycle
D/Q8
D/Q0
FULL OFFSET REGISTER
9
10
11
12
13
14
15
16
IDT72T1845/72T1855/72T1865/72T1875/
72T1885/72T1895(1)
x9 Bus Width
D/Q17
D/Q0
D/Q16
EMPTY OFFSET  REGISTER
Data Inputs/Outputs
# of Bits Used
9 8 8 7 7 6 6 5 4 4 3 3 2 2 1
10
11
12
13
14
15
16
1st Parallel Offset Write/Read Cycle
Data Inputs/Outputs
2nd Parallel Offset Write/Read Cycle
8 7 7 6 5 4 4 3 3 2 2 1
10
11
12
13
14
15
9
FULL OFFSET REGISTER
9 8 8 7 7 6 6 5 5 4 3 2 2 1
10
11
12
13
14
15
16
8 7 7 6 6 5 5 4 3 2 2 1
10
11
12
13
14
15
9
Non-Interspersed
Parity
Interspersed
Parity
D/Q17
D/Q0
D/Q16
D/Q8
D/Q8
16
16
IDT72T1845/72T1855/72T1865/72T1875/
72T1885/72T1895
x18 Bus Width
4666 drw 06
D/Q17
D/Q0
D/Q16
EMPTY OFFSET (LSB)  REGISTER
Data Inputs/Outputs
# of Bits Used
9 8 8 7 7 6 6 5 5 4 3 3 2 2 1
10
11
12
13
14
15
EMPTY OFFSET (MSB)  REGISTER
Data Inputs/Outputs
17
16
18
1st Parallel Offset Write/Read Cycle
2nd Parallel Offset Write/Read Cycle
Data Inputs/Outputs
Data Inputs/Outputs
3rd Parallel Offset Write/Read Cycle
4th Parallel Offset Write/Read Cycle
8 7 7 6 6 5 4 4 3 3 2 2 1
10
11
12
13
14
15
9
18 17
FULL OFFSET (LSB)  REGISTER
9 8 8 7 7 6 6 5 5 4 4 3 3 2 1
10
11
12
13
14
15
16
8 7 6 5 5 4 4 3 3 2 1
10
11
12
13
14
15
9
FULL OFFSET (MSB)  REGISTER
17
18
18 17
Non-Interspersed
Parity
Interspersed
Parity
D/Q17
D/Q0
D/Q16
D/Q17
D/Q0
D/Q16
D/Q17
D/Q0
D/Q16
D/Q8
D/Q8
16
16
IDT72T18105/72T18115/72T18125
x18 Bus Width
5909 drw07
19
19
19
19
18
19
20
18
19
20
NOTES:
1. When programming the IDT72T1895 with an input bus width of x9 and output bus width of x18, 4 write cycles will be required. When Reading the IDT72T1895 with an output
bus width of x9 and input bus width of x18, 4 read cycles will be required. A total of 6 program/read cycles will be required if both the input and output bus widths are set to x9.
2. Consecutive reads of the offset registers is not permitted. The read operation must be disabled for a minimum of one RCLK cycle in between offset register accesses. (Please
refer to  Figure 22, Parallel Read of Programmable Flag Registers (IDT Standard and FWFT Modes) for more details).