mvc view pdf : Adding text to pdf in reader control application platform web page azure wpf web browser 72T18125L10BB-Integrated-Device-Technology-datasheet-53173824-part1486

41
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
Figure 17 . 
R
C
S
R
C
S
R
C
S
R
C
S
R
C
S
 and 
R
E
N
R
E
N
R
E
N
R
E
N
R
E
N
 Read Operation (FWFT Mode)
NOTES:
1.It is very important that the REN
 be held HIGH for at least one cycle after RCS
 has gone LOW. If REN goes LOW on the same cycle as RCS
 or earlier, then Word, W1 will be lost, Word, W2 will be read on the output when the
bus goes to LOW-Z.
2.The 1st Word will fall through to the output register regardless of REN and RCS. However, subsequent reads require that both REN and RCS
 be active, LOW.
WCLK
RCLK
REN
Qn
1
2
WEN
3
tENS
tENH
tENS
tENS
tENS
tENH
tENS
tREF
tREF
RCS
OR
tRCSLZ
W1
W2
tRCSHZ
tRCSLZ
tA
W2
tSKEW
tENS
tENH
W2
Dn
tDH
tDS
tDH
tDS
W1
1st Word falls through to
O/P register on this cycle
5909 drw21
HIGH-Z
Adding text to pdf in reader - insert text into PDF content in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
XDoc.PDF for .NET, providing C# demo code for inserting text to PDF file
adding a text field to a pdf; add text to pdf without acrobat
Adding text to pdf in reader - VB.NET PDF insert text library: insert text into PDF content in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Providing Demo Code for Adding and Inserting Text to PDF File Page in VB.NET Program
how to add text to pdf file with reader; how to add text field to pdf form
42
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
tREF
tENS
tENH
5909 drw22
tENS
WMK-1
WCLK
RCLK
REN
RT
EF
PAF
HF
PAE
Qn
1
2
1
tPAFS
tREF
2
WEN
tENS
tA
tENS
WMK
WMK+1
tA
tA
WMK+n
tA
WMK
WMK+1
tA
tENS
MARK
tENH
tENS
(tPAES
tA
tSKEW2
tHF
3
Figure 18.  Retransmit from Mark (IDT Standard Mode)
NOTES:
1.Retransmit setup is complete when EF returns HIGH.
2.  OE = LOW;RCS
 = LOW.
3.RT
 must be HIGH when reading from FIFO.
4.Once Mark is set, the write pointer will not increment past the ‘marked’ location, preventing overwrites of Retransmit data.
5.Before a “MARK” can be set there must be at least 32 bytes of data between the Write Pointer and Read Pointer locations for the IDT72T1845/72T1855/72T1865/72T1875/72T1885/72T1895, 64 bytes of data for the IDT72T18105/
72T18115 and 128 bytes of data for the IDT72T18125. (32 bytes = 16 words = 8 long words).
6.A transition in the PAE
 flag may occur one RCLK cycle earlier than shown, (on cycle 2).
C# PDF Annotate Library: Draw, edit PDF annotation, markups in C#.
C# source code for adding or removing annotation from PDF Support to take notes on adobe PDF file without Support to add text, text box, text field and crop
how to input text in a pdf; add text pdf
VB.NET PDF Text Box Edit Library: add, delete, update PDF text box
Barcoding. XImage.Barcode Reader. XImage.Barcode Generator. Others. Provide VB.NET Users with Solution of Adding Text Box to PDF Page in VB.NET Project.
add text boxes to a pdf; how to enter text in pdf
43
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
Figure 19.  Retransmit from Mark (First Word Fall Through Mode)
tREF
tENS
tENH
5909 drw23
tENS
WMK-1
WCLK
RCLK
REN
RT
OR
PAF
HF
PAE
Qn
1
2
1
tPAFS
tREF
2
WEN
tENS
tA
tENS
WMK
WMK+1
tA
tA
WMK+n
tA
WMK+1
WMK+2
tA
tENS
MARK
tENH
tENS
(tPAES
tA
tSKEW2
tHF
WMK
tA
3
NOTES:
1.Retransmit setup is complete when OR returns LOW.
2.  OE = LOW;RCS
 = LOW.
3.RT must be HIGH when reading from FIFO.
4.Once Mark is set, the write pointer will not increment past the ‘marked’ location, preventing overwrites of Retransmit data.
5.Before a “MARK” can be set there must be at least 32 bytes of data between the Write Pointer and Read Pointer locations for the IDT72T1845/72T1855/72T1865/72T1875/72T1885/72T1895, 64 bytes of data for the IDT72T18105/
72T18115 and 128 bytes of data for the IDT72T18125. (32 bytes = 16 words = 8 long words).
6.A transition in the PAE
 flag may occur one RCLK cycle earlier than shown, (on cycle 2).
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Support adding PDF page number. Offer PDF page break inserting function. DLLs for Adding Page into PDF Document in VB.NET Class. Add necessary references:
adding text pdf file; add text pdf file
C# PDF Text Box Edit Library: add, delete, update PDF text box in
Provide .NET SDK library for adding text box to PDF document in .NET WinForms application. Adding text box is another way to add text to PDF page.
add text to pdf document in preview; how to insert text in pdf reader
44
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
Figure 20.  Serial Loading of Programmable Flag Registers (IDT Standard and FWFT Modes)
NOTES:
1. x9 to x9 mode: X =12 for the IDT72T1845, X = 13 for the IDT72T1855, X = 14 for the IDT72T1865, X = 15 for the IDT72T1875, X = 16 for the IDT72T1885, X = 17 for the IDT72T1895,
X = 18 for the IDT72T18105, X = 19 for the IDT72T18115 and X = 20 for the IDT72T18125.
2. All other modes: X=11 for the IDT72T1845, X = 12 for the IDT72T1855, X = 13 for the IDT72T1865, X = 14 for the IDT72T1875, X = 15 for the IDT72T1885 and X = 16 for the IDT72T1895,
X = 17 for the IDT72T18105, X = 18 for the IDT72T18115 and X = 19 for the IDT72T18125.
SCLK
SEN
SI
5909 drw24
LD
EMPTY OFFSET
FULL OFFSET
BIT X
(1)
t
SENS
t
LDS
t
SDS
t
SENH
t
LDS
BIT X
(1)
BIT 1
t
ENH
t
LDH
t
SDH
t
SCLK
t
SCKH
t
SCKL
BIT 1
NOTES:
1.  
OE
= LOW.
2. The timing diagram illustrates reading of offset registers with an output bus width of 18 bits.
3. The offset registers cannot be read on consecutive RCLK cycles. The read must be disabled (
REN
= HIGH) for a minimum of one RCLK cycle in between register accesses.
Figure 22.  Parallel Read of Programmable Flag Registers (IDT Standard and FWFT Modes)
Figure 21.  Parallel Loading of Programmable Flag Registers (IDT Standard and FWFT Modes)
NOTES:
1.   This  timing diagram is based on programming with  a  x18 bus width.
2. Overwrites  previous  offset  value.
WCLK
LD
WEN
D
0
- D
17
5909 drw25
t
LDS
t
ENS
PAE OFFSET
t
DS
t
DH
t
LDH
t
ENH
t
CLK
t
CLKH
t
CLKL
PAF OFFSET
PAE(2) OFFSET
PAF(2) OFFSET
t
DH
t
DH
t
DH
t
DS
t
DS
t
DS
t
LDH
t
ENH
RCLK
LD
REN
Q
0
- Q
17
DATA IN OUTPUT REGISTER
PAE OFFSET VALUE
PAF OFFSET VALUE
5909 drw26
t
LDH
t
ENH
t
CLK
t
CLKL
t
CLKH
t
A
t
LDS
t
LDH
t
LDS
t
LDH
t
LDS
t
ENS
t
ENH
t
ENS
t
ENH
t
ENS
t
A
PAE OFFSET
t
A
VB.NET PDF Library SDK to view, edit, convert, process PDF file
Support adding protection features to PDF file by adding password, digital signatures and redaction feature. Various of PDF text and images processing features
adding text field to pdf; how to insert text box on pdf
C# PDF insert image Library: insert images into PDF in C#.net, ASP
supports inserting image to PDF in preview without adobe PDF reader installed. technical problem, we provide this C#.NET PDF image adding control, XDoc
add text to pdf file online; adding text fields to a pdf
45
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
NOTES:
1. m = 
PAF
offset .
2. D = maximum  FIFO depth.
In IDT Standard mode: if x18 Input or x18 Output bus Width is selected, D = 2,048 for the IDT72T1845, 4,096 for the IDT72T1855, 8,192 for the IDT72T1865, 16,384 for the IDT72T1875,
32,768 for the IDT72T1885, 65,536 for the IDT72T1895, 131,072 for the IDT72T18105, 262,144 for the IDT72T18115 and 524,288 for the IDT72T18125. If both x9 Input and x9
Output bus Widths are selected, D = 4,096 for the IDT72T1845, 8,192 for the IDT72T1855, 16,384 for the IDT72T1865, 32,768 for the IDT72T1875, 65,536 for the IDT72T1885,
131,072 for the IDT72T1895, 262,144 for the IDT72T18105, 524,288 for the IDT72T18115 and 1,048,576 for the IDT72T18125.
In FWFT mode: if x18 Input or x18 Output bus Width is selected, D = 2,049 for the IDT72T1845, 4,097 for the IDT72T1855, 8,193 for the IDT72T1865, 16,385 for the IDT72T1875,
32,769 for the IDT72T1885, 65,537 for the IDT72T1895, 131,073 for the IDT72T18105, 262,145 for the IDT72T18115 and 524,289 for the IDT72T18125. If both x9 Input and x9
Output bus Widths are selected, D = 4,097 for the IDT72T1845, 8,193 for the IDT72T1855, 16,385 for the IDT72T1865, 32,769 for the IDT72T1875, 65,537 for the IDT72T1885,
131,073 for the IDT72T1895, 262,145 for the IDT72T18105, 524,289 for the IDT72T18115 and 1,048,577 for the IDT72T18125.
3. t
SKEW2
is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that 
PAF
will go HIGH (after one WCLK cycle plus t
PAFS
). If the time between the
rising edge of RCLK and the rising edge of WCLK is less than t
SKEW2
, then the 
PAF
deassertion time may be delayed one extra WCLK cycle.
4.
PAF
is asserted and updated on the rising edge of WCLK only.
5. Select this mode by setting PFM HIGH during Master Reset.
6.
RCS
is LOW.
Figure 23.  Synchronous Programmable Almost-Full Flag Timing (IDT Standard and FWFT Modes)
WCLK
WEN
PAF
RCLK
REN
5909 drw27
1
2
1
2
D-(m+1) words
in FIFO
(2)
D - m words in FIFO
(2)
D - (m +1) words in FIFO
(2)
t
ENH
t
ENS
t
PAFS
t
ENS
t
ENH
t
CLKL
t
SKEW2
(3)
t
PAFS
t
CLKL
NOTES:
1. n = 
PAE
offset.
2. For IDT Standard mode
3. For  FWFT  mode.
4.
t
SKEW2
is the minimum time between a rising WCLK edge and a rising RCLK edge to guarantee that 
PAE
will go HIGH (after one RCLK cycle plus t
PAES
).  If the time between the
rising  edge  of WCLK and  the  rising  edge  of  RCLK is  less  than  t
SKEW2
,  then  the 
PAE
deassertion  may be  delayed  one  extra  RCLK  cycle.
5.
PAE
is asserted and updated on the rising edge of WCLK only.
6. Select this mode by setting PFM HIGH during Master Reset.
7.
RCS
= LOW.
Figure 24.  Synchronous Programmable Almost-Empty Flag Timing (IDT Standard and FWFT Modes)
WCLK
WEN
PAE
RCLK
1
2
1
2
REN
5909 drw28
n + 1 words in FIFO
(2)
,
n + 2 words in FIFO
(3)
t
ENS
t
SKEW2
(4)
t
ENH
t
PAES
n words in FIFO
(2)
,
n + 1 words in FIFO
(3)
t
PAES
n  words in FIFO
(2)
,
n + 1 words in FIFO
(3)
t
ENS
t
ENH
t
CLKH
t
CLKL
VB.NET PDF Text Add Library: add, delete, edit PDF text in vb.net
Barcoding. XImage.Barcode Reader. XImage.Barcode Generator. Others. Professional VB.NET Solution for Adding Text Annotation to PDF Page in VB.NET.
how to insert a text box in pdf; add text to pdf file
C# PDF Page Insert Library: insert pages into PDF file in C#.net
By using reliable APIs, C# programmers are capable of adding and inserting (empty) PDF page or pages from various file formats, such as PDF, Tiff, Word, Excel
how to add text fields to pdf; add editable text box to pdf
46
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
NOTES:
1. m = 
PAF
offset.
2. D =  maximum FIFO depth.
In IDT Standard mode: if x18 Input or x18 Output bus Width is selected, D = 2,048 for the IDT72T1845, 4,096 for the IDT72T1855, 8,192 for the IDT72T1865, 16,384 for the IDT72T1875,
32,768 for the IDT72T1885, 65,536 for the IDT72T1895, 131,072 for the IDT72T18105, 262,144 for the IDT72T18115 and 524,288 for the IDT72T18125. If both x9 Input and x9
Output bus Widths are selected, D = 4,096 for the IDT72T1845, 8,192 for the IDT72T1855, 16,384 for the IDT72T1865, 32,768 for the IDT72T1875, 65,536 for the IDT72T1885,
131,072 for the IDT72T1895, 262,144 for the IDT72T18105, 524,288 for the IDT72T18115 and 1,048,576 for the IDT72T18125.
In FWFT mode: if x18 Input or x18 Output bus Width is selected, D = 2,049 for the IDT72T1845, 4,097 for the IDT72T1855, 8,193 for the IDT72T1865, 16,385 for the IDT72T1875,
32,769 for the IDT72T1885, 65,537 for the IDT72T1895, 131,073 for the IDT72T18105, 262,145 for the IDT72T18115 and 524,289 for the IDT72T18125. If both x9 Input and x9
Output bus Widths are selected, D = 4,097 for the IDT72T1845, 8,193 for the IDT72T1855, 16,385 for the IDT72T1865, 32,769 for the IDT72T1875, 65,537 for the IDT72T1885,
131,073 for the IDT72T1895, 262,145 for the IDT72T18105, 524,289 for the IDT72T18115 and 1,048,577 for the IDT72T18125.
3.
PAF
is asserted to LOW on WCLK transition and reset to HIGH on RCLK transition.
4. Select this mode by setting PFM LOW during Master Reset.
5.
RCS
is LOW.
Figure 25.  Asynchronous Programmable Almost-Full Flag Timing (IDT Standard and FWFT Modes)
WCLK
WEN
PAF
D - (m + 1) words
in FIFO
RCLK
t
PAFA
REN
5909 drw29
D - m words
in FIFO
D - (m + 1) words in FIFO
t
ENS
t
PAFA
t
ENH
t
ENS
t
CLKL
t
CLKH
NOTES:
1. n = 
PAE 
offset.
2. For IDT Standard Mode.
3. For  FWFT  Mode.
4.
PAE
is asserted LOW on RCLK transition and reset to HIGH on WCLK transition.
5. Select this mode by setting PFM LOW during Master Reset.
6.
RCS
= LOW.
Figure 26.  Asynchronous Programmable Almost-Empty Flag Timing (IDT Standard and FWFT Modes)
WCLK
WEN
PAE
n words in FIFO
(2)
,
n + 1 words in FIFO
(3)
RCLK
REN
5909 drw30
t
PAEA
n + 1 words in FIFO
(2)
,
n + 2 words in FIFO
(3)
t
PAEA
t
ENS
t
ENS
t
ENH
t
CLKL
t
CLKH
 words in FIFO
(2)
,
n + 1 words in FIFO
(3)
47
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
NOTES:
1. In IDT Standard mode: D = maximum FIFO depth. If x18 Input or x18 Output bus Width is selected, D = 2,048 for the IDT72T1845, 4,096 for the IDT72T1855, 8,192 for the IDT72T1865,
16,384 for the IDT72T1875, 32,768 for the IDT72T1885, 65,536 for the IDT72T1895, 131,072 for the IDT72T18105, 262,144 for the IDT72T18115 and 524,288 for the IDT72T18125.
If both x9 Input and x9 Output bus Widths are selected, D = 4,096 for the IDT72T1845, 8,192 for the IDT72T1855, 16,384 for the IDT72T1865, 32,768 for the IDT72T1875, 65,536
for the IDT72T1885, 131,072 for the IDT72T1895, 262,144 for the IDT72T18105, 524,288 for the IDT72T18115 and 1,048,576 for the IDT72T18125.
2. In FWFT mode: D = maximum FIFO depth. If x18 Input or x18 Output bus Width is selected, D = 2,049 for the IDT72T1845, 4,097 for the IDT72T1855, 8,193 for the IDT72T1865,
16,385 for the IDT72T1875, 32,769 for the IDT72T1885, 65,537 for the IDT72T1895, 131,073 for the IDT72T18105, 262,145 for the IDT72T18115 and 524,289 for the IDT72T18125.
If both x9 Input and x9 Output bus Widths are selected, D = 4,097 for the IDT72T1845, 8,193 for the IDT72T1855, 16,385 for the IDT72T1865, 32,769 for the IDT72T1875, 65,537
for the IDT72T1885, 131,073 for the IDT72T1895, 262,145 for the IDT72T18105, 524,289 for the IDT72T18115 and 1,048,577 for the IDT72T18125.
3.
RCS
= LOW.
Figure 27.  Half-Full Flag Timing (IDT Standard and FWFT Modes)
WCLK
t
ENS
t
ENH
WEN
HF
t
ENS
t
HF
RCLK
t
HF
REN
5909 drw31
t
CLKL
t
CLKH
D/2 words in FIFO(1),
[
+ 1
]
words in FIFO
(2)
D-1
2
D/2 + 1 words in FIFO
(1)
,
[
+ 2
]
words in FIFO
(2)
D/2 words in FIFO(1),
[
+ 1
]
words in FIFO
(2)
D-1
2
D-1
2
48
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
Figure 28.  Echo Read Clock & Read Enable Operation (IDT Standard Mode Only)
tENS
tENH
tENS
RCS
RCLK
REN
Qn
tERCLK
tENS
5909 drw32
ERCLK
tENH
EREN
tCLKEN
tCLKEN
tCLKEN
tCLKEN
tREF
EF
WD-4
tA
tOLZ
tOHZ
tA
tOLZ
tA
tA
Last Word, WD
WD-3
WD-3
WD-2
WD-1
tCLKEN
tCLKEN
NOTES:
1.The EREN output is an “ANDed” function of RCS
 and REN and will follow these inputs provided that the FIFO is not empty. If the FIFO is empty, EREN
 will go HIGH, thus preventing any reads.
2.The EREN
 output is synchronous to RCLK.
49
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
Qn
O/P
Reg.
t
A
t
REF
OR
5909 drw33
t
RCSLZ
REN
t
ENS
t
ENH
RCS
t
ENS
RCLK
a
b
c
d
e
f
g
h
i
W
n+1
WCLK
WEN
D0 - Dn
t
SKEW1
t
ENS
t
DS
t
ENH
W
n+2
W
n+3
ERCLK
EREN
t
CLKEN
t
CLKEN
t
CLKEN
t
CLKEN
W
n+1
W
n+2
W
n+3
t
A
t
REF
W
n+1
W
n+2
W
n+3
t
A
W
Last Word
t
A
t
A
t
DH
t
DH
t
DH
t
DS
t
DS
1
2
t
ERCLK
HIGH-Z
Figure 29. Echo RCLK and Echo 
RREENNNNN
Operation (FWFT Mode Only)
NOTE:
1. The O/P Register is the internal output register. Its contents are available on the Qn output bus only when 
RCS
and 
OE
are both active, LOW, that is the bus is not in High-
Impedance state.
2.
OE
is LOW.
Cycle:
a&b. At this point the FIFO is empty, 
OR
is HIGH.
RCS
and 
REN
are both disabled, the output bus is High-Impedance.
c.
Word Wn+1 falls through to the output register, 
OR
goes active, LOW.
RCS
is HIGH, therefore the Qn outputs are High-Impedance. 
EREN
goes LOW to indicate that a new word has been placed on the output register.
d.
EREN
goes HIGH, no new word has been placed on the output register on this cycle.
e.
No  Operation.
f.
RCS
is LOW on this cycle, therefore the Qn outputs go to Low-Impedance and the contents of the output register (Wn+1) are made available.
NOTE: In FWFT mode is important to take 
RCS
active LOW at least one cycle ahead of 
REN
, this ensures the word (Wn+1) currently in the output register is made
available  for at least  one  cycle.
g.
REN
goes active LOW, this reads out the second word, Wn+2.
EREN
goes active LOW to indicate a new word has been placed into the output register.
h.
Word Wn+3 is read out, 
EREN
remains active, LOW indicating a new word has been read out.
NOTE: Wn+3 is the last word in the FIFO.
i.
This is the next enabled read after the last word, Wn+3 has been read out. 
OR
flag goes HIGH and 
EREN
goes HIGH to indicate that there is no new word available.
50
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72T1845/55/65/75/85/95/105/115/125 2.5V TeraSync™ 18-BIT/9-BIT FIFO
2Kx18/4Kx9, 4Kx18/
8Kx9, 8Kx18/16Kx9, 16Kx18/32Kx9, 32Kx18/64Kx9, 64Kx18/128Kx9, 128Kx18/256Kx9, 256Kx18/512Kx9, 512Kx18/1Mx9
FEBRUARY 10, 2009
Figure 30.  Asynchronous Write, Synchronous Read, Full Flag Operation (IDT Standard Mode)
Figure 31.  Asynchronous Write, Synchronous Read, Empty Flag Operation (IDT Standard Mode)
RCLK
REN
5909 drw34
FF
Qn
W
0
t
A
W
1
t
ENH
t
ENS
t
FFA
t
FFA
t
FFA
WR
t
CYH
Dn
t
DS
W
D
t
DH
W
D+1
t
CYC
RCLK
REN
5909 drw35
Qn
Last Word
t
A
W
0
t
ENH
t
ENS
t
SKEW
WR
Dn
W
0
t
DH
1
2
t
A
W
1
t
REF
t
REF
EF
t
CYL
t
DS
t
CYH
W
1
t
DH
t
DS
t
CYC
NOTE:
1.
OE
= LOW, 
WEN
= LOW and 
RCS
= LOW.
NOTE:
1.
OE
= LOW, 
WEN
= LOW and 
RCS
= LOW.