Uo
28 V
IIC
80 nF
4 mH
54μH/Ω
Io
93 mA
IIB
640 nF
16 mH 218μH/Ω
Po
650 mW
IIA
2.1 μF
32 mH 436μH/Ω
Uo
21.4 V
IIC
0.16 μF
4 mH
54μH/Ω
Io
93 mA
IIB
1.13 μF
16 mH 218μH/Ω
Po
650 mW
IIA
4.15 μF
32 mH 436μH/Ω
Group
Module 9116B1
Term. 54-52; 51-52 
Module 9116B2
Term. 54-52; 51-52 
Co
Lo
Lo/Ro
Co
Lo
Lo/Ro
Group
Terminal 54-52
Ui
30 V
Ii
120 mA
Pi
900 mW
Ci
3 nF
Li
2μH
Module 9116B 1/2
Hazardous area
Non Hazardous area 
Zone 0, 1, 2, 20, 21, 22
or Zone 2
-20ºC≤Ta ≤+60ºC
T
+
-
54
53
52
51
44
43
42
41
9116
34
33
32
31
14
13
12
11
Power Rail
4501
54
53
52
51
44
43
42
41
9116
34
33
32
31
14
13
12
11
Power Rail
4501
4-20 mA 
Loop-powered 
transmitter
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
U
m:
253 V max. 400 Hz
Status relay, terminal (33,34)
Non hazardous area installation
Voltage max: 125 VAC / 110 VDC 
Power max:
62.5 VA / 32 W
Current max: 0.5 A AC / 0.3 ADC 
Zone 2 installation:
Voltage max: 32 VAC / 32 VDC 
Power max:
16 VA / 32 W
Current max: 0.5 A AC / 1 A DC
Relay output, terminal (13,14)
Non hazardous area installation
Voltage max: 250 VAC / 30 VDC
Power max:
500 VA / 60 W
Current max: 2 A AC / 2 ADC
Zone 2 installation
Voltage max: 32 VAC / 30 VDC
Power max:
64 VA / 60 W
Current max: 2 A AC / 2 ADC
Adding text to pdf document - insert text into PDF content in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
XDoc.PDF for .NET, providing C# demo code for inserting text to PDF file
add text to pdf document online; how to insert a text box in pdf
Adding text to pdf document - VB.NET PDF insert text library: insert text into PDF content in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Providing Demo Code for Adding and Inserting Text to PDF File Page in VB.NET Program
adding text fields to a pdf; add text pdf professional
40 
9116 - Product Version 9116-003
9116QA01  
LERBAKKEN 10, 8410 ROENDE DENMARK
Revisiondate:
2012-07-04
Version Revision
V6R0 
Preparedby:
PB
Page:
4/4
Uo
16.6 V
IIC
0.4 μF
100 mH  25mH/Ω
Io
0.2 mA
IIB
2.3 μF
100 mH 100mH/Ω
Po
0.8 mW
IIA
9.5 μF
100 mH 200mH/Ω
Lo/Ro
Module 9116B 1/2
Term. 52-51, 51-52 
Group
Co
Lo
Terminal 51-52
Ui
30 V
Ii
120 mA
Pi
900 mW
Ci
3 nF
Li
2μH
Module 9116B 1/2
Hazardous area
Non Hazardous area 
Zone 0,1,2, 20, 21, 22
or Zone 2
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
DLLs for Adding Page into PDF Document in VB.NET Class. Add necessary references: RasterEdge.Imaging.Basic.dll. RasterEdge.Imaging.Basic.Codec.dll.
add text boxes to a pdf; add text to pdf in acrobat
C# PDF Annotate Library: Draw, edit PDF annotation, markups in C#.
C#.NET: Add Text Box to PDF Document. Provide users with examples for adding text box to PDF and edit font size and color in text box field in C#.NET program.
how to add text to a pdf in reader; how to add text box to pdf document
9116 - Product Version 9116-003 
41
9116QF01  
LERBAKKEN 10, 8410 ROENDE DENMARK
Revisiondate:
2012-06-08
Version Revision
V6 R0
Preparedby:
PB
Page:
1/4
FM Installation drawing
9116
For safe installation of 9116B the following must be observed. The module shall only be installed by 
qualified personnel who are familiar with the national and international laws, directives and 
standards that apply to this area. 
Year of manufacture can be taken from the first two digits in the serial number.
4501
For Installation in Zone 2 / Division 2 the following must be observed.
The 4501 programming module is to be used solely with PRelectronics modules. It is important 
that the module is undamaged and has not been altered or modified in any way. Only 4501 
modules free of dust and moisture shall be installed.
c-FM-us Certificate    …………………………………………………….. 3038267
Hazardous Classified Location
Class I/II/III, Division 1, Group A,B,C,D,E,F,G 
or Class I, Zone 0/1 Group IIC, [AEx ia] IIC
or Class I, Zone 0/1 Group IIC, [Ex ia] IIC
-20≤Ta ≤+60ºC
Unclassified Location or
Hazardous Classified Location 
Class I, Division 2 Group A,B,C,D  T4
or Class I, Zone 2, Group IIC T4
Simple Apparatus or 
Intrinsic safe apparatus 
with entity parameters:
Vmax (Ui) ≥Vt (Uo)
Imax (Ii) ≥It (Io)
Pi ≥ Pt (Po)
Ca ≥ C
cable
+ Ci
La ≥ L
cable
+ Li
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
U
m:
253V max. 400 Hz
Status relay, terminal (33,34)
Non hazardous area installation
Voltage max: 125 VAC / 110 VDC 
Power max:
62.5 VA / 32 W
Current max: 0.5 A AC / 0.3 ADC 
Zone 2 installation:
Voltage max: 32 VAC/ 32 VDC 
Power max:
16 VA / 32 W
Current max: 0.5 A AC / 1 A DC
Relay output, terminal (13,14)
Non hazardous area installation
Voltage max: 250 VAC / 30 VDC
Power max:
500 VA / 60 W
Current max: 2 A AC / 2 ADC
Zone 2 installation
Voltage max: 32 VAC / 30 VDC
Power max:
64 VA / 60 W
Current max: 2 A AC / 2 ADC
4-wire
2-wire
3-wire
-
TC
RTD / LinR
VB.NET PDF Library SDK to view, edit, convert, process PDF file
Feel free to define text or images on PDF document and extract accordingly. Capable of adding PDF file navigation features to your VB.NET program.
add text box in pdf document; how to insert text into a pdf
VB.NET PDF Text Box Edit Library: add, delete, update PDF text box
C#.NET Winforms Document Viewer, C#.NET WPF Document Viewer. VB.NET PDF - Add Text Box to PDF Page in VB Provide VB.NET Users with Solution of Adding Text Box to
how to enter text in pdf form; how to add text to a pdf file in acrobat
42 
9116 - Product Version 9116-003
9116QF01  
LERBAKKEN 10, 8410 ROENDE DENMARK
Revisiondate:
2012-06-08
Version Revision
V6 R0
Preparedby:
PB
Page:
2/4
Terminal 51-52, 51-53
Terminal 51-52, 51-53
Ui, Vmax
30 V
Ui, Vmax
30 V
Ii, Imax
120 mA
Ii, Imax
120 mA
Pi
900 mW
Pi
900 mW
Ci
3 nF
Ci
3 nF
Li
1μH
Li
1μH
Uo, Voc
28 V
IIC or A,B
80 nF
4 mH
54μH/Ω
Uo, Voc
21.4 V
IIC or A,B
0.16 μF
4 mH
54μH/Ω
Io, Isc
93 mA
IIB or C,E,F
640 nF
16 mH 218μH/Ω
Io, Isc
93 mA
IIB or C,E,F
1.13 μF
16 mH 218μH/Ω
Po
650 mW
IIA or D,G
2.1 μF
32 mH 436μH/Ω
Po
650 mW
IIA or D,G
4.15 μF
32 mH 436μH/Ω
Uo, Voc
28 V
IIC or A,B
80 nF 1000 mH
4 mH/Ω
Uo, Voc
21.4 V
IIC or A,B
0.16 μF 1000 mH
4 mH/Ω
Io, Isc
1.1 mA IIB or C,E,F
640 nF 1000 mH 17 mH/Ω
Io, Isc
1.1 mA IIB or C,E,F
1.13 μF 1000 mH 17 mH/Ω
Po
8 mW
IIA or D,G
2.1 μF 1000 mH 35 mH/Ω
Po
8 mW
IIA or D,G
4.15 μF 1000 mH 35 mH/Ω
Uo, Voc
8.3 V
IIC or A,B
7 μF 1000 mH100 mH/Ω
Uo, Voc
8.3 V
IIC or A,B
7 μF 1000 mH100 mH/Ω
Io, Isc
0.2 mA IIB or C,E,F
73 μF 1000 mH400 mH/Ω
Io, Isc
0.2 mA IIB or C,E,F
73 μF 1000 mH400 mH/Ω
Po
0.4 mW
IIA or D,G
1000 μF 1000 mH800 mH/Ω
Po
0.4 mW
IIA or D,G
1000 μF 1000 mH800 mH/Ω
Uo, Voc
8.3 V
IIC or A,B
7 μF
207 mH
1 mH/Ω
Uo, Voc
8.3 V
IIC or A,B
7 μF
207 mH
1 mH/Ω
Io, Isc
13.1 mA IIB or C,E,F
73 μF
828 mH
5 mH/Ω
Io, Isc
13.1 mA IIB or C,E,F
73 μF
828 mH
5 mH/Ω
Po
27.3 mW IIA or D,G
1000 μF 1000 mH 10 mH/Ω
Po
27.3 mW IIA or D,G
1000 μF 1000 mH 10 mH/Ω
Co
Lo
Lo/Ro
Module 9116B1
Terminal 41,42,43,44 
Group
Co
Group
Co
Lo
Lo/Ro
Module 9116B1
Terminal 51-52 
Group
Co
Lo
Lo/Ro
Module 9116B2
Terminal 51-52 
Group
Co
Lo
Lo/Ro
Module 9116B1
Terminal 51-53 
Group
Co
Lo
Lo/Ro
Module 9116B2
Terminal 51-53 
Group
Module 9116B1
Module 9116B2
Module 9116B1
Terminal 51-54, 52-54
Group
Co
Lo
Lo/Ro
Module 9116B2
Terminal 51-54, 52-54
Group
Lo
Lo/Ro
Module 9116B2
Terminal 41,42,43,44 
Co
Lo
Lo/Ro
Installation notes:
The installation and wiring shall be in accordance with the Canadian Electrical Code for Canada and 
National Electrical Code NFPA 70, Article 500 or 505 for installation in USA.
The module must be supplied from a Power Supply having double or reinforced insulation.
The use of stranded wires is not permitted for mains wiring except when wires are fitted with cable ends.
For installation on the 9400 Power Rail the power must be supplied from Power Control Module Unit 9410.
Install in pollution degree 2 or better, overvoltage categoryI orII.
The module must be installed in an enclosure suitable for the environment for which it is used.
In Class I, Division 2/Zone 2installations, the subject equipment shall be mounted within atool-secured 
enclosure which is capable of accepting one or more of the Class I, Division 2 wiring methods specified in 
the NationalElectrical Code for USA or the Canadian Electrical Code for Canada
The module is galvanic isolated and does not require grounding.
Use 60 / 75 ºC Copper Conductors with wire Size AWG: (26-14).
Warning: Substitution of components may impair intrinsic safety.
Warning: To prevent ignition of the explosive atmospheres, disconnect power before servicing and do not 
separate connectors when energized and an explosive gas mixture is present.
Warning: Do not mount or remove modules from the Power Rail when an explosive gas mixture is present.
C# PDF Text Box Edit Library: add, delete, update PDF text box in
DNN (DotNetNuke), SharePoint. Provide .NET SDK library for adding text box to PDF document in .NET WinForms application. A web based
adding text to pdf reader; adding text to a pdf form
C# PDF Page Insert Library: insert pages into PDF file in C#.net
This C# .NET PDF document page inserting & adding component from RasterEdge is written in managed C# code and designed particularly for .NET class applications
how to enter text in pdf file; adding text pdf files
9116 - Product Version 9116-003 
43
9116QF01  
LERBAKKEN 10, 8410 ROENDE DENMARK
Revisiondate:
2012-06-08
Version Revision
V6 R0
Preparedby:
PB
Page:
3/4
Ui, Vmax
30 V
Ii, Imax
120 mA
Pi
900 mW
Ci
3 nF
Li
2μH
Module 9116B 1/2
Terminal 52-54
Uo, Voc
28 V
IIC or A,B
80 nF
4 mH
54μH/Ω
Io, Isc
93 mA
IIB or C,E,F
640 nF
16 mH 218μH/Ω
Po
650 mW IIA or D,G
2.1 μF
32 mH 436μH/Ω
Uo, Voc
21.4 V
IIC or A,B
0.16 μF
4 mH
54μH/Ω
Io, Isc
93 mA
IIB or C,E,F
1.13 μF
16 mH 218μH/Ω
Po
650 mW IIA or D,G
4.15 μF
32 mH 436μH/Ω
Module 9116B2
Terminal 52-54 
Group
Co
Lo
Lo/Ro
Lo/Ro
Module 9116B1
Terminals 52-54
Group
Co
Lo
T
VB.NET PDF Text Add Library: add, delete, edit PDF text in vb.net
NET Winforms Document Viewer, C#.NET WPF Document Viewer. VB.NET PDF - Annotate Text on PDF Page in VB Professional VB.NET Solution for Adding Text Annotation to
add text to pdf file reader; add text pdf
C# PDF insert image Library: insert images into PDF in C#.net, ASP
Using this C# .NET image adding library control for PDF document, you can easily and quickly add an image, picture or logo to any position of specified PDF
add text field to pdf; add text to pdf acrobat
44 
9116 - Product Version 9116-003
9116QF01  
LERBAKKEN 10, 8410 ROENDE DENMARK
Revisiondate:
2012-06-08
Version Revision
V6 R0
Preparedby:
PB
Page:
4/4
Ui, Vmax
30 V
Ii, Imax
120 mA
Pi
900 mW
Ci
3 nF
Li
2μH
Terminal 51-52
Module 9116B 1/2
Uo, Voc
16.6 V
IIC or A,B
0.4 μF
100 mH  25mH/Ω
Io, Isc
0.2 mA IIB or C,E,F
2.3 μF
100 mH  100mH/Ω
Po
0.8 mW
IIA or D,G
9.5 μF
100 mH  200mH/Ω
Lo
Lo/Ro
Module 9116B 1/2
Terminals 51-52 
Group
Co
+
-
54
53
52
51
44
43
42
41
9116
34
33
32
31
14
13
12
11
Power Rail
4501
54
53
52
51
44
43
42
41
9116
34
33
32
31
14
13
12
11
Power Rail
4501
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
U
m:
253V max. 400 Hz
Hazardous Classified Location
Class I/II/III, Division 1, Group A,B,C,D,E,F,G 
or Class I, Zone 0/1 Group IIC, [AEx ia] IIC 
or Class I, Zone 0/1 Group IIC, [Ex ia] IIC
Unclassified Location or
Hazardous Classified Location 
Class I, Division 2 Group A,B,C,D  T4
or Class I, Zone 2, Group IIC T4
0/4-20 mA 
Current Source
-20ºC ≤Ta ≤+60ºC
Status relay, terminal (33,34)
Unclassified location installation:
Voltage max: 125 VAC / 110 VDC 
Power max:
62.5 VA / 32 W
Current max: 0.5 A AC / 0.3 ADC 
Zone 2 installation:
Voltage max: 32 VAC/ 32 VDC 
Power max:
16 VA / 32 W
Current max: 0.5 A AC / 1 A DC
Relay output, terminal (13,14)
Unclassified location installation:
Voltage max: 250 VAC / 30 VDC
Power max:
500 VA / 60 W
Current max: 2 A AC / 2 ADC
Zone 2 installation
Voltage max: 32 VAC / 30VDC
Power max:
64 VA / 60W
Current max: 2 A AC / 2ADC
Version No. V3R0
Safety manual
unIVeRSal COnVeRteR 
9116 
this safety manual is valid for the following product versions:
9116-003
9116-002
9116-001
Version No. V3R0
1
9116 Universal converter 
safety Manual
 Observed standards ..................................................................................................... 
3
 Acronyms and abbreviations ....................................................................................... 
3
 Purpose of the product ................................................................................................ 
3
 Assumptions and restrictions for use of the product .................................................. 
4
4.1  Basic safety specifications .................................................................................. 
4
4.2  Safety accuracy ................................................................................................... 
4
4.2.1  Minimum span ......................................................................................... 
4
4.2.2  Range limitations ..................................................................................... 
4
4.3  Associated equipment ......................................................................................... 
4
4.3.1  RTD or linear resistance sensor wiring .................................................... 
4
4.3.3  Process calibration .................................................................................. 
5
4.3.4  Analogue output ...................................................................................... 
5
4.3.5  Relay output ............................................................................................. 
5
4.4  Failure rates ......................................................................................................... 
5
4.5  Safe parameterisation .......................................................................................... 
5
4.6  Installation in hazardous areas ............................................................................ 
5
 Functional specification of the safety function ............................................................ 
5
 Functional specification of the non-safety functions ................................................... 
6
 Safety parameters ........................................................................................................ 
6
 Hardware and software configuration .......................................................................... 
7
 Failure category ............................................................................................................ 
8
10 Periodic proof test procedure ...................................................................................... 
9
11 Procedures to repair or replace the product................................................................ 
9
12 Maintenance ................................................................................................................. 
9
13 Documentation for routing diagram ............................................................................. 
9
13.1 In general ............................................................................................................. 
9
13.2 Further explanations ............................................................................................ 
9
13.2.1 Password protection ................................................................................ 
9
13.2.2 Sensor/cable fault information via display front 4501 .............................  10
13.3 Advanced functions (ADV.SET) ............................................................................  10
13.3.1 Memory (MEM) ........................................................................................  10
13.3.2 Display setup (DISP) ................................................................................  10
13.3.3 Password (PASS) .....................................................................................  10
13.3.4 Language (LANG).....................................................................................  10
13.3.5 Process calibration (CAL) ........................................................................  10
13.3.6 Power rail (RAIL) ......................................................................................  10
13.3.7 Simulation (SIM) .......................................................................................  11
13.3.8 Safety integrity level (SIL) ........................................................................  11
14 Safe parameterisation - user responsibility .................................................................  11
14.1 Safety-related configuration parameters .............................................................  11
14.1.1 Common parameters ...............................................................................  11
14.1.2 Parameters related to Relay Output ...........................................................  14
14.1.3. Parameters related to analouge output ...................................................  15
14.2.  Verification procedure ..............................................................................  16
14.2.1 If no password is set ...............................................................................  17
14.2.2 If password is set .....................................................................................  20
14.2.3 If any parameter is found to be incorrect during verification ..................  20
14.3 Functional test .....................................................................................................  20
 COntentS
Version No. V3R0
Safety Manual 
9116 UniverSal converter
15 Fault reaction and restart condition .............................................................................  20
16 User interface ...............................................................................................................  21
16.2 Routing diagram ..................................................................................................  23
16.3 Routing diagram - Advanced settings (ADV.SET)................................................  26
17 Connections diagram ...................................................................................................  27
Version No. V3R0
3
9116 Universal converter 
safety Manual
 Observed standards
 acronyms and abbreviations
 Purpose of the product
Conversion and scaling of temperature (Pt, Ni and TC), voltage, potentiometer, linear resistance 
and current signals from hazardous area.
The device can be mounted in the safe area and in zone 2 / div. 2 and receive signals from zone 
0, 1, 2, 20, 21 and 22 / Class I/II/III, Div. 1, Gr. A-G.
Error events, including cable faults, are monitored and signalled via the individual status relay 
and/or a collective electronic signal via the power rail.
The 9116 has been designed, developed and certified for use in SIL 2 applications according 
to the requirements of IEC 61508.
Acronym / 
Abbreviation 
Designation 
Description 
Element
Term defined by IEC 61508 as “part of a 
subsystem comprising a single component or any 
group of components that performs one or more 
element safety functions”
PFD 
Probability of Failure 
on Demand 
This is the likelihood of dangerous safety function 
failures occurring on demand. 
PFH
Probability of danger-
ous Failure per Hour
The term “Probability” is misleading, as IEC 
61508 defines a Rate.
SFF 
Safe Failure Fraction 
Safe Failure Fraction summarises the fraction of 
failures which lead to a safe state and the fraction 
of failures which will be detected by diagnostic 
measures and lead to a defined safety action.
SIF
Safety Integrity 
Function
Function that provides fault detection (to ensure the 
necessary safety integrity for the safety functions)
SIL 
Safety Integrity Level 
The international standard IEC 61508 specifies four 
discrete safety integrity levels (SIL 1 to SIL 4). Each 
level corresponds to a specific probability range 
regarding the failure of a safety function. 
Standard
Description 
IEC 61508
Functional Safety of electrical / electronic / programmable electronic 
safety-related systems
IEC 61508-
2:2000
Part 2: Requirements for electrical / electronic / programmable electronic 
safety-related systems
IEC 61508-
3:1998
Part 3: Software requirements
IEC 61326-3-
1:2008
Immunity requirements for safety-related systems 
Documents you may be interested
Documents you may be interested