open pdf file in c# web application : Adding a text field to a pdf software control cloud windows azure wpf class 2071-rm001_-en-p6-part786

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
61
Standard Drive Parameters Appendix A
Table 1 - Setting Values for Parameters [Pr - 0.10]…[Pr - 0.21]
[Pr - 0.21]
Allocation of Input Signals 12
Data Size
4 digits
Digit
Description
Default
Unmapped IO 
Status
0
Reserved 
0x0
OFF
1
Reserved
0x0
OFF
2
Reserved 
0x0
OFF
3
Reserved
0x0
OFF
When Enabled
Reserved 
Applicable Operating Mode
Indexing 
Modbus Address 
22 
Setting Value 
(1)
(1) Setting values are reserved (not available) for [Pr - 0.19]
and [Pr - 0.20]
B
A
9
6
7
Input Channel No.  Input 
Signal
19  9 
Input 
Signal 
CN1 Pin No. 
On 
26  27  29  9 
Off 
[Pr - 0.22]
Allocation of Output Signals 1
Range for all digits
0…3, where 0 is Off and 1…6 are digital outputs
Data Size
4 digits
Digit
Description
Default
0
Within position window (P-COM) 
0x1
1
Up to speed (TG-ON) 
0x2
2
Brake control (BK) 
0x3
3
Within speed window (V-COM) 
0x0
When Enabled
Servo-Off -> Setting 
(1)
(1) Refer toSetting Values for Parameters [Pr - 0.22]…[Pr - 0.32] on page66
Applicable Operating Mode
All
Modbus Address 
23 
Adding a text field to a pdf - insert text into PDF content in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
XDoc.PDF for .NET, providing C# demo code for inserting text to PDF file
how to add text to a pdf document; how to add text box to pdf
Adding a text field to a pdf - VB.NET PDF insert text library: insert text into PDF content in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Providing Demo Code for Adding and Inserting Text to PDF File Page in VB.NET Program
how to add text to a pdf in acrobat; adding text to pdf reader
62
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A
Standard Drive Parameters
[Pr - 0.23]
Allocation of Output Signals 2
Range for all digits
0…3, where 0 is Off and 1…6 are digital outputs
Data Size
4 digits
Digit
Description
Default
0
Current limited (T_LMT)
0x0
1
Velocity limited (V-LMT)
0x0
2
Near position (NEAR)
0x0
3
Warning (WARN)
0x0
When Enabled
Servo-Off -> Setting 
(1)
(1) Refer toSetting Values for Parameters [Pr - 0.22]…[Pr - 0.32] on page66
Applicable Operating Mode
All
Modbus Address 
24 
[Pr - 0.24]
Allocation of Output Signals 3
Range for all digits
0…3, where 0 is Off and 1…6 are digital outputs
Data Size
4 digits
Digit
Description
Default
0
Absolute position valid (A_VLD)
0x0
1
Ready
0x0
2
Reserved
0x0
3
Reserved
0x0
When Enabled
Servo-Off -> Setting 
(1)
(1) Refer toSetting Values for Parameters [Pr - 0.22]…[Pr - 0.32] on page66
Applicable Operating Mode
All
Modbus Address 
25 
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Support adding PDF page number. Offer PDF page break inserting function. DLLs for Adding Page into PDF Document in VB.NET Class. Add necessary references:
add text pdf; add text to pdf document in preview
VB.NET PDF Library SDK to view, edit, convert, process PDF file
Support adding protection features to PDF file by adding password, digital signatures and redaction feature. Various of PDF text and images processing features
adding text to a pdf in preview; add editable text box to pdf
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
63
Standard Drive Parameters Appendix A
[Pr - 0.25]
Allocation of Output Signals 4
Range for all digits
0…3, where 0 is Off and 1…6 are digital outputs
Data Size
4 digits
Digit
Description
Default
0
In Motion (IMO) 
0x0
1
In Dwell (I_DW) 
0x0
2
Axis Homed (HOMC) 
0x0
3
Index Select 0 Out (O_ISEL0) 
0x0
When Enabled
Servo-Off -> Setting 
(1)
(1) Refer toSetting Values for Parameters [Pr - 0.22]…[Pr - 0.32] on page66
Applicable Operating Mode
Indexing
Modbus Address 
26 
C# PDF insert image Library: insert images into PDF in C#.net, ASP
Insert images into PDF form field. To help you solve this technical problem, we provide this C#.NET PDF image adding control, XDoc.PDF for .NET.
how to add a text box to a pdf; how to add text fields to a pdf
C# PDF Page Insert Library: insert pages into PDF file in C#.net
By using reliable APIs, C# programmers are capable of adding and inserting (empty) PDF page or pages from various file formats, such as PDF, Tiff, Word, Excel
adding text to pdf file; add text to pdf file online
64
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A
Standard Drive Parameters
[Pr - 0.26]
Allocation of Output Signals 5
Range for all digits
0…3, where 0 is Off and 1…6 are digital outputs
Data Size
4 digits 
Digit
Description
Default
0
Index Select 1 Out (O_ISEL1)
0x0
1
Index Select 2 Out (O_ISEL2)
0x0
2
Index Select 3 Out (O_ISEL3)
0x0
3
Index Select 4 Out (O_ISEL4)
0x0
When Enabled
Servo-Off -> Setting 
(1)
(1) Refer toSetting Values for Parameters [Pr - 0.22]…[Pr - 0.32] on page66
Applicable Operating Mode
Indexing
Modbus Address 
27 
[Pr - 0.27]
Allocation of Output Signals 6
Range for all digits
0…3, where 0 is Off and 1…6 are digital outputs
Data Size
4 digits 
Digit
Description
Default
0
Index Select 5 Out (O_ISEL5)
0x0
1
End of Sequence (E_SEQU)
0x0
2
Reserved
0x0
3
Reserved
0x0
When Enabled
Servo-Off -> Setting 
(1)
(1) Refer toSetting Values for Parameters [Pr - 0.22]…[Pr - 0.32] on page66
Applicable Operating Mode
Indexing 
Modbus Address 
28 
[Pr - 0.28]
Allocation of Output Signals 7
Range for all digits
0…3, where 0 is Off and 1…6 are digital outputs
Data Size
4 digits
Digit
Description
Default
0
Reserved
0x0
1
Reserved
0x0
2
Reserved
0x0
3
Reserved
0x0
When Enabled
Reserved 
Applicable Operating Mode
Indexing
Modbus Address 
29 
VB.NET PDF Text Box Edit Library: add, delete, update PDF text box
Auto Fill-in Field Data. Field: Insert, Delete, Update Field. VB.NET PDF - Add Text Box to PDF Page in VB Provide VB.NET Users with Solution of Adding Text Box to
add text pdf acrobat; adding text fields to a pdf
C# PDF Text Box Edit Library: add, delete, update PDF text box in
Provide .NET SDK library for adding text box to PDF document in .NET WinForms application. Adding text box is another way to add text to PDF page.
add text pdf professional; add text to pdf in preview
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
65
Standard Drive Parameters Appendix A
[Pr - 0.29]
Allocation of Output Signals 8
Range for all digits
0…3, where 0 is Off and 1…6 are digital outputs
Data Size
4 digits 
Digit
Description
Default
0
Reserved
0x0
1
Reserved
0x0
2
Reserved
0x0
3
Reserved
0x0
When Enabled
Reserved 
Applicable Operating Mode
Indexing
Modbus Address 
30 
[Pr - 0.30]
Allocation of Output Signals 9
Range for all digits
0…3, where 0 is Off and 1…6 are digital outputs
Data Size
4 digits 
Digit
Description
Default
0
Reserved
0x0
1
Reserved
0x0
2
Reserved
0x0
3
Reserved
0x0
When Enabled
Reserved 
Applicable Operating Mode
Indexing
Modbus Address 
31 
C# PDF Annotate Library: Draw, edit PDF annotation, markups in C#.
Provide users with examples for adding text box to PDF and edit font size and color in text box field in C#.NET program. C#.NET: Draw Markups on PDF File.
adding text to a pdf document acrobat; add text to pdf acrobat
C# PDF Digital Signature Library: add, remove, update PDF digital
VB.NET read PDF, VB.NET convert PDF to text, VB.NET the Security of Your PDF File by Adding Digital Signatures. Search unsigned signature field in PDF document.
how to add text to a pdf document using reader; how to add text to a pdf in reader
66
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A
Standard Drive Parameters
[Pr - 0.31]
Allocation of Output Signals 10
Range for all digits
0…3, where 0 is Off and 1…6 are digital outputs
Data Size
4 digits
Digit
Description
Default
0
Reserved
0x0
1
Reserved
0x0
2
Reserved
0x0
3
Reserved
0x0
When Enabled
Reserved 
Applicable Operating Mode
Indexing
Modbus Address 
32 
[Pr - 0.32]
I/O Control Authority
Applicable Operating Mode
All
Data Size 
2 digits
Digit 0
Modbus Input Function Control
Ultraware Name
Modbus Input Function Control 
Range
Value
Description
0x0
Disable
0x1
Enable
Default
0
Digits 1
Modbus Run Function Control
Ultraware Name
Modbus Run Function Control 
Range
Value
Description
0x0
Disable
0x1
Enable
Default
0
When Enabled
Servo-Off -> Setting 
(1)
(1) Refer to Setting Values for Parameters [Pr - 0.22]…[Pr - 0.32]
in the table immediately below. 
Applicable Operating Mode
All 
Modbus Address 
33 
Setting Values for Parameters [Pr - 0.22]
[Pr - 0.32]
Setting Value 
(1)
(1) Setting Values are reserved (not available) for [Pr - 0.28]
and [Pr - 0.31]
Input ChannelNo. 
AL #3 
AL #2 
AL#1 
DO#3 
DO#2 
DO#1 
Input Signal 
CN1 Pin No. 
39
38
37
47,48
43,44 
41,42 
Off 
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
67
Standard Drive Parameters Appendix A
Group 1 - Gain Control 
[Pr - 1.00]
Velocity Regulator Response Level
Ultraware Name
Velocity Regulator Response level
Range
1…150
Default
50
Units
%
When Enabled 
Immediately 
Applicable Operating Mode 
All 
Modbus Address
100 
[Pr - 1.01]
System Gain 
Ultraware Name
System Gain
Range
10...500
Default
50
Units
Hz 
When Enabled 
Immediately 
Applicable Operating Mode 
All 
Modbus Address
101 
[Pr - 1.02]
Velocity Regulator P Gain 
Ultraware Name
Main Velocity Regulator Gains: Proportional Gain 
Range
0…10,000
Default
60
Units
-
When Enabled 
Immediately 
Applicable Operating Mode 
Follower, Analog Speed, Preset
Modbus Address
102 
[Pr - 1.03]
Velocity Regulator I Gain
Ultraware Name
Main Velocity Regulator Gains: Integral Gain
Range
0…60,000
Default
26
Units
-
When Enabled 
Immediately 
Applicable Operating Mode 
Follower, Analog Speed, Preset
Modbus Address
103 
68
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A
Standard Drive Parameters
[Pr - 1.04]
Velocity Regulator D gain
Ultraware Name
Main Velocity Regulator Gains: Derivative Gain 
Range
0…1000
Default
0
Units
-
When Enabled 
Immediately 
Applicable Operating Mode 
Follower, Analog Speed, Preset
Modbus Address
104 
[Pr - 1.05]
Velocity Error Filter
Ultraware Name
Calibration: Error Filter Bandwidth
Range
0…2500
Default
30
Units
Hz
When Enabled 
Immediately 
Applicable Operating Mode 
Follower, Analog Speed, Preset
Modbus Address
105 
[Pr - 1.06]
Position Regulator Kp Gain
Ultraware Name
Main Position Regulator Gains: Kp
Range
0…700
Default
20
Units
Hz
When Enabled 
Immediately 
Applicable Operating Mode 
Follower, Analog Speed, Preset
Modbus Address
106 
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
69
Standard Drive Parameters Appendix A
[Pr - 1.07]
Current Command Lowpass Filter Bandwidth
Ultraware Name
Main Current Regulator Gains: Low Pass Filter Bandwidth
Range
0…10,000
Default
300
Units
Hz
Applicable Operating Mode
All
When Enabled
Immediately
When Enabled 
Immediately 
Applicable Operating Mode 
All 
Modbus Address
107 
[Pr - 1.08]
Velocity Command Lowpass Filter Bandwidth
Ultraware Name
Main Velocity Regulator Gains: Low Pass Filter Bandwidth
Range
0…10,000
Default
1000
Units
Hz
When Enabled 
Immediately 
Applicable Operating Mode 
Follower, Analog Speed, Preset
Modbus Address
108 
[Pr - 1.09] 
Position Command Lowpass Filter Bandwidth
Ultraware Name
Main Position Regulator Gains: Low Pass Filter Bandwidth
Range
0…1000
Default
0
Units
Hz
When Enabled 
Immediately 
Applicable Operating Mode 
Follower 
Modbus Address
109 
[Pr - 1.10]
1st Resonant Frequency Suppression Filter
Ultraware Name
Main Current Regulator Gains: 1st Resonant Frequency 
Suppression Filter
Description
Suppresses Vibration by cutting off Current Command in 
assigned frequency band
Range
0…10,000
Default
10,000
Units
Hz
When Enabled 
Immediately 
Applicable Operating Mode 
All 
Modbus Address
110 
70
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A
Standard Drive Parameters
[Pr - 1.11]
1st Resonant Frequency Suppression Filter Width
Ultraware Name
Main Current Regulator Gains: 1st Resonant Frequency 
Suppression Filter Width
Description
Set up the notch width of 1st resonance suppressing filter 
in 20 steps. Higher the setup, larger the notch width you 
can obtain.
Range
1…20
Default
10
Units
When Enabled 
Immediately 
Applicable Operating Mode 
All 
Modbus Address
111 
[Pr - 1.12]
2nd Resonant Frequency Suppression Filter
Ultraware Name
2nd Main Current Regulator Gains: 2nd Resonant 
Frequency Suppression Filter
Description
Suppresses Vibration by cutting off Current Command in 
assigned frequency band
Range
0…10,000
Default
10,000
Units
Hz
When Enabled 
Immediately 
Applicable Operating Mode 
All 
Modbus Address
112 
[Pr - 1.13]
2nd Resonant Frequency Suppression Filter Width
Ultraware Name
Main Current Regulator Gains: 2nd Resonant Frequency 
Suppression Filter Width
Description
Set up the notch width of 2nd resonance suppressing 
filter in 20 steps. The higher the setup, larger the notch 
width you can obtain.
Range
1…20
Default
10
Units
-
When Enabled 
Immediately 
Applicable Operating Mode 
All 
Modbus Address
113 