open pdf file in iframe in asp.net c# : Remove text from pdf online SDK control service wpf azure asp.net dnn NSi_AutoStore_AdminGuide_en39-part1089

Admin Guide – AutoStore 6.0 
391   
Version 1.2 
Copyright 2012 Notable Solutions, Inc. 
Name 
Type  
Propertie
Value 
Example 
Contrast  
numbe
(short)  
N/A 
1-100 
Form.ScanSettings.Contrast=60 
Threshold 
numbe
(short)  
N/A 
1-255 
Form.ScanSettings.Threshold=7
Lock 
Object   
Form.scansettings.lock.color=tr
ue 
Form.scansettings.lock.color=fal
se 
Brightness 
-100 to 100  
default 0 
PageSize 
PS_AUTO =0, 
PS_A4LETTER=1, 
PS_B5LETTER = 2, 
PS_USLETTER = 3, 
PS_USLEGAL = 4, 
PS_A5 = 5, 
PS_B4 = 6, 
PS_B6 = 7, 
PS_USLEDGER = 9, 
PS_USEXECUTIVE = 10, 
PS_A3 = 11, 
PS_B3 = 12, 
PS_A6 = 13, 
PS_C4 = 14, 
PS_C5 = 15, 
PS_C6 = 16, 
PS_4A0 = 17, 
PS_2A0 = 18, 
PS_A0 = 19, 
PS_A1 = 10, 
PS_A2 = 21, 
PS_A7 = 22, 
PS_A8 = 23, 
PS_A9 = 24, 
PS_A10 = 25, 
PS_ISOB0 = 26, 
PS_ISOB1 = 27,v PS_ISOB2 = 28, 
PS_ISOB5 = 29, 
PS_ISOB7 = 30, 
PS_ISOB8 = 31, 
PS_ISOB9 = 32, 
PS_ISOB10 = 33, 
Remove text from pdf online - delete, remove text from PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# developers to use mature APIs to delete and remove text content from PDF document
how to delete text from a pdf in acrobat; delete text pdf acrobat professional
Remove text from pdf online - VB.NET PDF delete text library: delete, remove text from PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Programming Guide to Delete Text from PDF File
remove text watermark from pdf; delete text pdf preview
Admin Guide – AutoStore 6.0 
392   
Version 1.2 
Copyright 2012 Notable Solutions, Inc. 
Name 
Type  
Propertie
Value 
Example 
PS_JISB0 = 34, 
PS_JISB1 = 35, 
PS_JISB2 = 36, 
PS_JISB3 = 37, 
PS_JISB4 = 38, 
PS_JISB6 = 39, 
PS_JISB7 = 40, 
PS_JISB8 = 41, 
PS_JISB9 = 42, 
PS_JISB10 = 43, 
PS_C0 = 44, 
PS_C1 = 45, 
PS_C2 = 46, 
PS_C3 = 47, 
PS_C7 = 48, 
PS_C8 = 49, 
PS_C9 = 50, 
PS_C10 = 51, 
PS_USSTATEMENT = 52, 
PS_BUSINESSCARD = 53 
Default PS_USLETTER 
Lock Object Properties
Name 
Type 
Color 
Boolean 
Contrast  Boolean  
Duplex 
Boolean  
JpegQuality Boolean  
Format 
Boolean  
ImageType Boolean  
Threshold   Boolean  
Resolution  Boolean  
Brightness  Boolean  
PageSize  Boolean  
C# PDF remove image library: remove, delete images from PDF in C#.
Delete Text from PDF. Text: Replace Text in PDF. Image: Insert Image to PDF. Image: Remove Image from PDF Page. Image: Copy, Paste, Cut
delete text from pdf online; remove text from pdf online
VB.NET PDF remove image library: remove, delete images from PDF in
Remove PDF image in preview without adobe PDF reader PDF SDK library download and online VB.NET Except PDF text processing function, RasterEdge XDoc.PDF for
remove text from pdf acrobat; how to copy text out of a pdf
Admin Guide – AutoStore 6.0 
393   
Version 1.2 
Copyright 2012 Notable Solutions, Inc. 
Welcome to POP3 Email component  
POP3 Email is a Capture (source) component used to retrieve Email messages from a mail server that 
supports POP3 protocol. This component retrieves and processes the Email messages including any 
attachments from the designated mailbox one at a time. The content of each email message including 
any attachments will be retrieved and processed as a single job. Upon completion of the processing by 
this component, the email message will be removed from the designated mailbox. 
POP3 stands for Post Office Protocol, Version 3. POP3 is a mail protocol that's used only to retrieve mail 
(from a POP3 enabled mail server), not to send mail. This component uses the POP3 protocol over TCP 
to query a POP3 enabled mail server for new mail messages. 
In order to use this component, a "POP3 account name" and its associated password for a specific mail 
server must be supplied. POP3 account name is a unique name of an electronic mailbox. This 
information must be unique so only the intended owner of a mailbox can gain access to it. 
Getting Started 
Feature highlights  
Major features of this component are: 
Retrieve email messages including attachments from a designated mailbox on a mail server that 
supports POP3 protocol. 
Save the email message as text or html file
Using POP3 Email component  
The following provides examples of common usage scenarios: 
Scan documents using a local scanner and email the scanned documents in to a designated POP3 
Email mailbox for processing.  
Forward incoming faxes in to a designated mailbox for processing. 
A company requires all project data to be converted to PDF and maintained into an archived 
database, can setup a process with POP3 Email as the source component, PDF Converter as a 
filter component, followed by the Folder Store as destination component. In this scenario, POP3 
Email inbox reads the email and converts the email and attachment(s) to PDF format and stores it 
in to a directory. In this situation, employees are able to archive documents, simply by sending 
VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
Ability to remove consecutive pages from PDF file in VB Enable specified pages deleting from PDF in Visual Basic Online source codes for quick evaluation in VB
remove text from pdf reader; acrobat remove text from pdf
VB.NET PDF Password Library: add, remove, edit PDF file password
Remove password from PDF. Dim outputFilePath As String = Program.RootPath + "\\" Remove.pdf" ' Remove password in the input file and output to a new file.
how to erase text in pdf; deleting text from a pdf
Admin Guide – AutoStore 6.0 
394   
Version 1.2 
Copyright 2012 Notable Solutions, Inc. 
email with attachment into the designated POP3 Email account and the process automatically 
reads the POP3 Email and converts the attachment to PDF for storage into the archival system. 
Configuring 
General tab  
Use this tab to set the following options: 
Server
User Name
Password
Port Number
Save the message as file
Server  
Enter the name or IP address of the mail server that the email message will be retrieved form. This mail 
server should support the POP3 protocol. 
User Name  
Enter the account user name that will be used to connect to the mail server. POP3 account user name is 
a unique name of an electronic mailbox. This information must be unique so only the intended owner of 
a mailbox can gain access to it. The POP3 account name is very often the first part of an email address. 
For example, if an email address is "
johndoe@xyz.com
", the POP3 account name is probably "johndoe". 
Password  
Enter the password for the user name that will be used to connect to the mail server. 
Port Number  
The port number that will be used by the POP3 Email component to establish a TCP connection to the 
mail server. 
The default port for POP3 connection is 110. 
Save email message as file  
The option will save the email header (i.e., To, From, Subject, …) and the email body as a text or html 
file. 
C# PDF Digital Signature Library: add, remove, update PDF digital
Delete Text from PDF. Text: Replace Text in PDF. Image: Insert Image to PDF. Image: Remove Image from PDF Page. Image: Copy, Paste, Cut
how to delete text from a pdf document; erase text from pdf
C# PDF Page Delete Library: remove PDF pages in C#.net, ASP.NET
Free online C# class source code for deleting specified PDF pages in .NET console application. Able to remove a single page from PDF document.
how to delete text in pdf using acrobat professional; how to delete text in pdf converter professional
Admin Guide – AutoStore 6.0 
395   
Version 1.2 
Copyright 2012 Notable Solutions, Inc. 
Using this option will not have any effect on the existing email file attachments. A new file be created 
that contains only the email header and body content.  
Component Setting tab  
Click on this tab and a list of all process component names and their description appears. Highlight the 
desired component and click on Configure
to configure all the attributes of that component. 
Runtime Replacement Tag (RRT) 
What are RRTs?  
Runtime Replacement Tags (RRT) are tags placed within the configuration file for replacement by 
metadata values during execution time. At runtime (when a component is executed within the 
application), each component is responsible for searching all items within the configuration memory 
structure and replacing their assigned RRTs with actual metadata values. The RRTs were formerly known 
as Field Value References or FVRs. 
RRT naming convention 
The figure below provides you with an illustration of the RRT definition. Each part of the RRT is designed 
to create a standard field tag replacement that can be expanded to all components designed and 
developed within the component framework. 
Important Note:
RRT’s are case sensitive. You must follow the proper case for all RRTs. You cannot 
introduce space characters in between the RRT segments. 
C# PDF Password Library: add, remove, edit PDF file password in C#
Support to add password to PDF document online or in C# String outputFilePath = Program.RootPath + "\\" Remove.pdf"; // Remove password in the input file and
pdf text remover; remove text from pdf preview
C# PDF bookmark Library: add, remove, update PDF bookmarks in C#.
Ability to remove and delete bookmark and outline entry.GetLocation()); Console.WriteLine("Text: " + entry.GetText NET Sample Code: Update PDF Document Outline
how to delete text from a pdf; how to delete text in pdf acrobat
Admin Guide – AutoStore 6.0 
396   
Version 1.2 
Copyright 2012 Notable Solutions, Inc. 
The table below provides details on each segment of the RRT: 
Segment 
Name 
Description 
Markers 
Special characters used to mark the beginning and the ending of each RRT. The “~” is 
used to mark each end. Note that you cannot use the same character anywhere within 
the other parts of the RRT. Having “~” appear as a value of a special field is not 
supported with this new RRT design. 
RRT ID 
Special three characters identifying the component owning the RRT and responsible for 
replacing the tags with the actual values. 
Separators 
Double colon “::” characters used to separate the Component RRT ID from the actual 
Replacement Tag Name. Double colon is now reserved and cannot be used within other 
parts of the RRT. Example of an illegal use of :: is “~MYC::Invoice::Number~” where the 
double colon is repeated within the replacement tag name 
Replacement 
Tag Name 
The Replacement Tag Name or RTN can be the name of the metadata collected from a 
content source (e.g., device, etc.), or a metadata generated by the component itself 
(e.g., XML data field, etc.). The following types of RTN are currently supported:  
i.
Reserved (RRTN)
– Each component is allowed to create and maintain a set of 
reserved RTN or RRTN. Within the boundaries of each component reserved names 
have special meaning. Each component defines a list of RRTNs.  
ii.
Field (FRTN)
- Some components that support field names allow the fields to be 
referenced using the special enclosure character: “%”. An example of field name 
used within RRT is:  
~MYC::%Invoice Number%~  
This example allows replacement for a field called “Invoice Number” within the 
MYC component with the value of the field Invoice Number.  
iii.
Special Sets (SSRTN)
- These are special set of characters providing you with 
useful information on the job such as document date, document time, etc. It’s 
important to note that not all components support the SSRTN values. Look in 
documentation for each component to find the components that do support 
SSRTNs  
How does it work?  
When you create a process that consists of a series of components, the components are executed in 
order from left to right (Capture to Route). Each component, prior to its termination, searches all 
configuration entries and replaces all its own RRTs with actual metadata values. As an example, the XML 
Admin Guide – AutoStore 6.0 
397   
Version 1.2 
Copyright 2012 Notable Solutions, Inc. 
Knowledge Package Loader component will search for RRT’s starting with “~ASX::” and replaces them 
with actual metadata values. 
The order of execution of components within a process is significant. Due to the component execution 
order (Capture to Route), RRT’s owned by components that appear later in a process cannot be placed 
within components that appear earlier in a process. As an example, placement of Folder Store 
component RRT’s within a Capture component such as Poll Directory is invalid and will not be replaced 
at runtime.  
Component's RRT  
This component’s ID for field value replacements is POP. The following Runtime Replacement Tags may 
be used in any of the components following the POP3 Email component as desired. 
For example if there is a SharePoint Process component defined in the process where POP3 Email is the 
Capture component, you can define the SharePoint Process (filter) "Subject" field as "~POP::Subject~. 
Others include: 
~POP::From~ 
~POP::To~ 
~POP::CC~ 
~POP::Subject~ 
~POP::Date~ 
~POP::Body~ 
Troubleshooting tips  
Problem Description 
Solution 
Status monitor 
indicates the 
component is unable 
to connect to the 
POP3 Email server. 
Verify that the POP3 protocol is enabled on the mail server. 
Verify that POP3 support is not disabled for the user's mailbox. 
Verify that the client can ping the server using the mail server's Internet 
protocol (IP) address and the mail server's computer name 
Try using an email client such as Microsoft Outlook Express to connect to 
user’s mailbox. 
Use a telnet tool to verify connection to the POP3 mail server. To do so, 
follow these steps:  
Open a telnet tool such as HyperTerminal. For the host name, type 
the name of the Mail Server computer, and for the port type, type 
110. If a "term type" is requested, do not type anything. For 
example, type telnet server 110. Then press ENTER. A message 
similar to the following should be displayed: + OK Microsoft 
Admin Guide – AutoStore 6.0 
398   
Version 1.2 
Copyright 2012 Notable Solutions, Inc. 
Problem Description 
Solution 
Exchange 2000 POP3 server version 6.0.6249.0 ready.
Enable local echo and Send line ends with line feed for the current 
telnet session. 
Type the following command, and then press ENTER: user 
domain\username\mailbox.
If the domain is the name of the 
domain in which the user's account is located, username is the user 
name, and mailbox is the user's mailbox. Note that the mailbox 
portion of the above command is only necessary if it is different 
from the username portion. When you press ENTER, +OK
should be 
displayed. 
Type the following command, and then press ENTER: pass password
Where password is the user's password. When you press ENTER, the 
following message should be displayed: +OK User successfully 
logged on.
To determine if the user has new messages, type stat
and then press 
ENTER. After you press ENTER, the following message should be 
displayed: +OK xyyyy
. Where x is the number of new messages and 
yyyy is the total size of the messages in bytes. This is known as a 
"drop listing."  
To end the Telnet session, type quit
, and then press ENTER, a 
message similar to the following should be displayed:+ OK Microsoft 
Exchange 2000 POP3 server version 6.0.6249.0 signing off.
.
Restrictions and limitations  
Messages are not accessible from another email client once they are downloaded to the local hard disk. 
Admin Guide – AutoStore 6.0 
399   
Version 1.2 
Copyright 2012 Notable Solutions, Inc. 
Welcome to Ricoh ESA component  
Ricoh ESA component allows direct integration of Ricoh device panel with the server.  This component 
provides key functionality such as: 
Device level authentication including Windows, Active Directory, and NetWare and custom script 
authentication. 
Multi-Layer menu definition that allows ease of use and quick indexing. 
Centralized meta-data form definition providing full centralized control over the indexing forms. 
Support for String, String list, Boolean, Date, Number, Database Lookup and Folder Browse field 
types to provide document indexing flexibility. 
Device groupings allow devices to be divided into functional or organizational groups. 
Extensible forms through VBscript. You can create more interactive forms and validate before a 
document is scanned. 
Access control support to menus and forms. 
Support for Duplex and Color Scanning. 
Create Send to Email forms, SharePoint 2007 forms and SharePoint 2010 forms. 
Ricoh ESA integration utilizes the latest in ESA technology and is designed to provide enterprise level 
functionality. 
Getting Started 
Device Setup & Configuration 
Supported Devices  
Please refer to http://www.nsius.com
for a complete up-to-date list of supported devices. 
Using this component  
Use this component to capture documents from the Ricoh ESA device and process the digitized 
document to transform the document for final storage in a repository or distribution of the document as 
email or fax. 
This component allows the Ricoh devices with ESA capability to integrate directly with the application. 
Additionally use the scripting capability provided by this component to create dynamic forms and fields 
that are connected with your applications.  Validation of form fields can also be done directly against the 
back-end application databases providing the user with a quality control indexing station directly on top 
of the Ricoh ESA devices. 
Admin Guide – AutoStore 6.0 
400   
Version 1.2 
Copyright 2012 Notable Solutions, Inc. 
This component provides a rich set of form fields to allow the user to capture String, String List, Date, 
Number, Boolean, Label field values.  Creation of forms using these devices is now very simple and easy 
to manage since all devices are centrally controlled from the AutoStore server. 
This implementation is truly an enterprise solution that can provide device grouping, scan setting 
control from a single location (no need to login to every device), centralized indexing form management, 
as well as support for Server Farms and load balancing for larger deployment of devices.  Use this 
component to allow your devices to access a rich set of workflows and reach the document capture 
efficiency beyond any other product in the marketplace.  
Install 
Install JavaTM Platform  
1.
Make sure that the Main Power of the Ricoh Device is turned OFF
2.
Insert SD card into available slot. Power ON
the Ricoh Device. 
3.
Press “User Tools/Counter/Inquiry
” hard button on the Ricoh Device control panel. 
4.
Press “Extended Feature Settings
” button in the bottom left of the screen to display the 
Extended Feature Settings Menu. 
5.
Press the "Extended Feature Settings"
button to display the Extended Feature Settings screen. 
6.
Press the “Install”
tab to display the "SD Card"
and "Web Server"
installation sources. 
7.
Press the "SD Card" button to display the JavaTM Platform. 
8.
Select the "JavaTM Platform
" to start the installation. 
9.
Select the appropriate SD Card slot as the destination installation and press the "Next
" button. 
10.
To start the installation press the "OK
" button on the Extended feature information screen.  A 
screen Installing the extended feature will appear showing that the installation process is being 
performed. 
11.
Once installation has completed press "Exit
" to end the installation. 
12.
To startup the JavaTM platform, press the "Startup Setting
" tab. 
13.
Press the "JavaTM Platform
" button. 
14.
Startup settings will be valid after turning the power of the machine on again. 
Install AutoStoreXlet  
Installation through Ricoh Device Manager 
1.
Locate the Ricoh Device Manager application.  The file will be in <Install 
Directory>\Distributables\Ricoh ESA\.  The name of the file is RicohDeviceManager.exe. 
2.
Double-click the file and start the application. 
3.
Select Add to add a Ricoh device.  Alternatively, select Import to add several Ricoh devices. 
4.
Select the Ricoh device(s) and click Install. 
Documents you may be interested