open pdf from windows form c# : Pull text out of pdf software control project winforms azure wpf UWP ReferenceManual_ApplicationsMaster_(English)_541-part1745

Reference Manual ApplicationsMaster 
Page   3 
SHORTCUTS 
On user interfaces, especially on main windows with a 
main menu, shortcuts are available to navigate. Press 
Alt + underlined character to select an entry. In some 
applications  shortcuts  can  be  defined  and  modified 
with the Options 
Preferences dialog. 
TABLES 
SELECTION 
Use the mouse, to select items. For multi selection use 
mouse and keyboard: 
mouse  +  shift:  selection  of  a  complete 
block 
mouse + ctrl: additive selection 
ctrl + a: select all items 
INLINE EDITING 
If a table heading is flagged with * (e.g. Save As*), the 
Pull text out of pdf - delete, remove text from PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# developers to use mature APIs to delete and remove text content from PDF document
acrobat delete text in pdf; how to erase in pdf text
Pull text out of pdf - VB.NET PDF delete text library: delete, remove text from PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Programming Guide to Delete Text from PDF File
how to copy text out of a pdf; how to delete text from a pdf in acrobat
Reference Manual ApplicationsMaster 
Page   4 
values  can  directly  be  edited  inside  the  table  cell. 
Clicking once into the table changes to edit mode. Hit 
return to accept the changes. 
SELECTION 
COUNTER 
In the lower left corner of a table there is a counter to 
display  the  number  of  currently  selected  items 
compared to the total number of elements. 
TABLE  UNITS 
If not displayed in the table headings, the units used in 
the table are displayed at the lower right corner of the 
table. 
MULTIPLE EDIT 
If multiple table entries have to be edited, the "Element 
Properties" dialogs (Edit...) have some parameters 
locked  that  are  not  editable  for  a  multiple  selection. 
Other elements have to be activated by clicking into a 
check box. Only those entries that are activated will be 
replaced. 
VB.NET PDF replace text library: replace text in PDF content in vb
PDF reader component installed. Able to pull text out of selected PDF page or all PDF document in VB.NET. Support .NET WinForms, ASP
how to delete text from a pdf document; pdf text remover
Reference Manual ApplicationsMaster 
Page   5 
FIND DIALOGUE 
To search for entries in a window table, this dialog is 
used. Key in the string(s) / words to search for into the 
Find text box. Select the Scope, i.e. the entry type to 
to 
search for. 
Optionally,  activate Case Sensitive  search  or  to 
to 
search Whole Words Only  (no  sub-string  search). 
h). 
Define  whether  to  search Forwards  or Backwards 
ds 
from  the current  cursor position. To start the  search, 
press the Find button. 
COLUMNS 
DIALOGUE 
Reference Manual ApplicationsMaster 
Page   6 
To deactivate or reactivate columns to be displayed in 
a window table, use the "Select Columns" dialog. 
Displayed table columns are  indicated by 
an activated check box. 
Click  into  a  check  box  to  activate  or 
deactivate the column. 
Use the Default button to reset the display 
to the state after the software was installed 
first. 
Activate Sort ID numerically (1, 2, 3...10, 
11,  12),  if  IDs  should  not  be  sorted  by 
characters (1,10,11...2,20,21...) 
SORT ID 
NUMERICALLY 
To change the sorting sequence from alphanumeric (1, 
10,11...2,20
,21…) to numerical sorting (1,2,3...10, 11, 
12),  activate  the  respective  selection  box  on  the 
different listing dialogs. 
2.2. Project Generation 
In version 5.x, project 
definition, editing and 
management have been 
combined into the “
Project 
Editor
“. All data necessary to 
set up a project can be 
assigned and loaded using the 
functionalities integrated in the 
Project Editor
” To start the 
project generation, press the 
menu entry labeled New or the 
corresponding tool button. 
Reference Manual ApplicationsMaster 
Page   7 
2.2.1.  Define General Parameters   
The  first  project  generation  step  consists  in  specifying  some  basic  settings. 
They are globally defined and will therefore apply to the entire project. These 
parameters have to be set at the beginning. However, they can be changed 
later by calling the 
“Basics” 
dialog within the 
Project Editor
”. 
But note if you 
change later on the coordinates system or unit settings, already existing data in 
the project is not changed. Therefore be careful in setting the correct coordinate 
system and units with the project generation and don‟t change it later on.
Settings 
Administrative project description and the operators name 
Log Filecontains error messages 
Select from the Units option menus the coordinate system and the units 
according to your project requirements: 
By default, a local coordinate system is defined. Using the ”
Other
” 
option 
makes  it  possible  to  select  an  already  existing  coordinate  system  or  to 
define a  new  one.   Please  refer  to  the  “
Coordinate  System
“ section  for 
more information. 
The default unit in image space is mm, in object space m respectively. For 
feet, take care to select the correct specification (international feet (ISO) / 
US feet). Changing the  units does NOT convert any values in  the project 
(e.g. ground control coordinates or IMU observations). 
Activate correction for Atmospheric Refraction and 
Earth’s
Curvature by 
clicking into the corresponding check box. 
Corrections 
The applications (e.g. MATCH-AT) are capable to take different corrections into 
account  to improve measured coordinates.  The following corrections can be 
activated in the 
Project Editor
Reference Manual ApplicationsMaster 
Page   8 
Lens distortion 
correction, activated in the “
Camera Editor
” is one of the 
standard corrections applied in block adjustments. Radial distortion values, 
coefficients  or  distortion  grids  are  entered  or  loaded  together  with  other 
camera calibration data in the “
Camera Editor
”. 
Some  digital  cameras  produce  already  corrected  images  so  a  distortion 
correction would not be necessary. This has to be decided according to the 
input data. 
If  distortion  correction  is  not  applied,  the  block  might  be  bending  in  the 
center,  so  it  is  better  to  activate  distortion  correction  even  if  only  small 
values are to be corrected. 
Earth Curvature and Atmospheric Refraction  corrections  are standard 
corrections,  too. Correction values are scientifically determined. So these 
corrections are independent from block geometry or control points.  
If small local object coordinate systems are used (no projections like UTM, 
GK...),  which  is  usually  not  the  case  in  aerial  photogrammetry,  earth 
curvature has to be deactivated in order not to correct for something that is 
already corrected. 
Note: No earth curvature correction should be applied, if a project is 
transformed from a projected system into a local coordinate system with a 
rigorous Rectangular Cartesian Coordinate System. 
Reference Manual ApplicationsMaster 
Page   9 
2.2.2.  Camera Editor 
Setting up a new project should 
start with the assignment of one 
or  several  camera(s)  because 
the  image  import  requires  an 
already  defined  camera.  The 
camera  editor  is  used  to  add 
and import as well as to edit the 
cameras. 
The 
“Camera  Editor”
dialog 
presents  all  camera  calibration 
data available  for  any  selected 
camera.  New  cameras  can  be 
defined,  others  deleted  or 
existing  camera  data  can  be 
modified.  All  information  about 
the  camera(s)  is  stored  in  the 
project file (*.prj). 
2.2.3.  Adding Photos  
For the photo definition, the “
Project Editor
” is equipped with the “
Add Photos
” 
dialogs  allowing  the  user  to  add  single  images  or  to  import  whole  photo 
directories. It  is  also  possible  to  change  attributes to all  selected  subsets of 
photos (e.g. camera) or to change the file paths of all selected photos.  
Additionally, an individual terrain height may be specified for each  photo and 
exterior  orientation  parameters  can  be  initialized  from  data  entered  in  the 
"GNSS/IMU" dialog or from GNSS and the "Strips" definition (Kappa values). 
2.2.4.  GNSS / IMU Data 
Following the image assignment all approximated or differtial GNSS (DGNSS) 
projection coordinates and if available approximated or given photo orientations 
(IMU also called INS) have to be loaded using the 
GNSS / IMU
” 
dialog. 
For definition of UltraCam cameras with IMU see also chapter 14.1.3 
2.2.5.  Strip Generation 
Strips play an important role in the automated aerial triangulation (MATCH-AT). 
The  following  section deals  with  some  general  remarks concerning  the  strip 
definition. Special information regarding the use of strips in MATCH-AT is given 
in the corresponding manual. 
The  “
Strip  Definition
”  dialog  enables  the  user  to  arrange  manually  or 
automatically images into strips. 
Reference Manual ApplicationsMaster 
Page  10 
Steps to work through: 
1. Possibility 
Select the "Frame Photos" dialog from the "Project 
Editor" main menu to import / add the additional photos.  
When using the "Photo Importer", select Initialize with 
existing  GNSS/IMU  orientations if full GNSS/IMU is 
available for the photos to be imported. 
When using the "Add Photos" dialog, select Initialize EO 
from  GNSS/IMU if full GNSS/IMU is available for the 
photos to be imported. 
Both  options  require  that  the  GNSS  /  IMU  data  has 
already been imported to the project file. 
2. Possibility: 
Select the "GNSS / IMU" dialog from the "Project Editor" 
main  menu,  to  import  /  add  additional  photo  centers 
needed for the photos to be added. 
Remember  that  for  each  photo,  an  approximate  photo 
center is needed to run the automatic aerial triangulation. 
In the import wizard on the last page, there is an option to 
Initialize  the  exterior  orientation  (EO)  of  existing 
photos... Activate this option to store the data as 
approximations for the photos. 
If  the  EO  is  not initialized  from here, it  has later to  be 
done in the "Photos" dialog 
Reference Manual ApplicationsMaster 
Page  11 
3. Possibility: 
Select the "Strips" dialog from the "Project Editor" main 
main 
menu, to edit or create strips with the new photos. 
If  the  new  photos  were  not  initialized  with  IMU  data,  a 
message will be prompted "strip violates kappa value 
integrity". You can let the software correct the kappa 
values for the photos automatically by computing it from 
the  strip  azimuth.  The  photos  have  to  be  previously 
initialized with the approximate photo centers (GNSS). 
The message indicates a difference  between the kappa 
value stored in the EO parameters of the photos and the 
computed  kappa  from  the  strip  azimuth  larger  than  18 
deg.  So  it  may  also  be  an  indicator  for  a  wrong  strip 
direction (check that in the "Strips" dialog) or an indicator 
or 
for  a  wrong  kappa  (e.g.  kappa  180deg)  definition  of 
imported IMU data. In addition, the mount rotation of the 
camera setup might need to be changed. 
If the (approximate) EO of the added photos has not been 
init
ialized correctly yet, go back to the “
Photos
” dialog. 
Check the EO parameters XYZ, omega, phi, kappa and if 
necessary  select  the  photos  to  be  edited.  Launch  the 
Edit
”  dialog  and
Initialize EO from GNSS/Null, from 
GNSS/Strip, or from  GNSS/IMU (if available). 
Reference Manual ApplicationsMaster 
Page  12 
2.2.6.  Standard Deviations 
For all observations (object points, image measurements, GNSS, IMU) used in 
the aerial triangulation, standard deviations a priori ("input accuracy") have to 
be specified. In every element editor dialog standard deviations can be defined. 
The  “
Standard  Deviations
“  dialog  opened  by  clicking  this  tool  button  will 
launch a window showing all standard deviations for all observation types to be 
edited. 
Documents you may be interested
Documents you may be interested