open pdf from windows form c# : How to erase pdf text application Library utility html .net windows visual studio ReferenceManual_ApplicationsMaster_(English)_5422-part1759

Reference Manual ApplicationsMaster 
Page 213 
DELETE 
MEASURE- 
MENT 
To delete a single already existing measurement, press this 
button. 
TRANSFORM. 
PARAMETERS 
The  table  contains  the  transformation  parameters 
(translations,  rotation,  affinity,  scales)  and  the  sigma  0 
depending on the transformation type. 
Sigma0 should correspond to app. 1/3 of a pixel. 
Sigma0=SQRT([vv] / n-u) 
r.m.s = root mean square = SQRT([vv]/n) 
The scale should correspond to the pixel size. 
v=residual, n=number of observations, u=unknowns 
For more information on  checking the results refer to the 
chapter "Analyzing Results 
Checking Interior Orientat-
ion". 
TRANSFORM. 
TYPE 
The  combo  box  includes  an  option  menu  which  permits 
selecting one of three different transformation types. 
4 Parameter also  known  as HELMERT 
transformation. It includes two translations, one 
scale  factor  and  one  rotation.  Use  this  type 
when  you  need  to  detect  systematic  film 
deformation  in  transportation  direction.  The 
residuals  will  indicate  the  deformation.  To 
compensate  this  effect  you  need  to  use  a  6 
parameter transformation. 
5 Parameter involves  two  translations,  two 
scale factors and one rotation. This helps for a 
scanner that produces non-quadratic pixels. 
6 Parameter also  known  as AFFIN 
transformation.  Admits  two  translations,  two 
scale factors and two rotations. This helps for 
cases  where  systematic  errors  occur  as  a 
result of warped film. 
CURSOR 
DEFINITION 
Clicking  on  this  button  will  open  an  extended  dialog  to 
specify the cursor color and the necessary parameters for 
the semi-automatic least squares measurement of fiducial 
marks. 
COLOR 
Use the color combo box to set the color of the measure 
cursor. Also the measured position (cross) is displayed with 
the specified color. 
How to erase pdf text - delete, remove text from PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# developers to use mature APIs to delete and remove text content from PDF document
remove text watermark from pdf online; how to edit and delete text in pdf file online
How to erase pdf text - VB.NET PDF delete text library: delete, remove text from PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Programming Guide to Delete Text from PDF File
how to delete text from pdf document; erase pdf text
Reference Manual ApplicationsMaster 
Page 214 
MATCH 
TEMPLATE 
Activate  this  checkbox  to  use  the  semi-automatic  least 
squares matching mode for the fiducial mark measurement. 
In the semiautomatic mode, it is enough to measure only 2 
fiducial  marks  manually.  The  remaining  ones  will  be 
measured automatically. If this option is active, the selected 
cursor size is used to calculate the size of the template.  
The  least  squares  matching  technique  overlays  the 
template  over  the  image  to  automatically  center  your 
measurement.  Since  this  needs  good  initial  values  to 
converge, the manual measurements necessarily should be 
1-2  pixels  accurate  and  the  template  (cursor)  should  be 
more  or  less  adjusted  to  the  size  of  the  fiducial  mark 
element. 
To use the semi-automatic mode with negative images you 
will have to check the Negative Template checkbox. 
NEGATIVE 
TEMPLATE 
Used to invert the template for the semi-automatic mode, 
i.e.  if  this  option  is  active  a  dark  mark  on  a  bright 
background is generated. Use this option only, if you are 
using  negative  imagery.  Refer  to  the Match Template 
function to find more information. 
CIRCLE 
CROSS 
BOX 
SIZE 
WIDTH 
ROTATION 
If  the  semi-automatic  measurement  is  activated,  it  is 
necessary to define the shape and size of the template that 
is used for least squares matching. 
Select the shape of the fiducial mark element that should 
automatically  be  measured  by  pressing  one  of  the  radio 
buttons labeled CircleCross or Box 
Depending  on  the  shape,  adjust  the SizeRotation  and 
Width of the cursor by moving the corresponding slider. 
Changes  in  those  settings  take  immediate  effect  on  the 
fiducial mark display. 
STATUS BAR 
The  status  bar  holds  online  help  information  and  the 
camera ID associated with the currently opened image file. 
C# WinForms Viewer: Load, View, Convert, Annotate and Edit PDF
Draw PDF markups. PDF Protection. • Sign PDF document with signature. • Erase PDF text. • Erase PDF images. • Erase PDF pages. Miscellaneous.
remove text from pdf acrobat; pull text out of pdf
C# WPF Viewer: Load, View, Convert, Annotate and Edit PDF
Draw markups to PDF document. PDF Protection. • Add signatures to PDF document. • Erase PDF text. • Erase PDF images. • Erase PDF pages. Miscellaneous.
how to delete text from a pdf document; delete text from pdf preview
Reference Manual ApplicationsMaster 
Page 215 
7.1.12.  Manual IO - Measuring Procedure 
The program requires images with at least one overview, i.e. an image with two 
image pyramid levels. Usually image pyramid levels are previously generated 
with the "Image Commander" tool. 
Steps to work through 
Select the image to be processed in the "Main Window List View" of the 
interior orientation dialog  by  left clicking its ID. Press the manual interior 
orientation  tool button  or select Start Manual IO from the IO sub-menu. 
The <Project Filecontains the file names of the images and the name of 
the  assigned  camera.  The  program  reads  the  fiducial  mark  coordinates 
from the <CAMERAfile. 
Before  zooming  into  the  fiducial  mark  views,  it  is  helpful  to  coarsely 
measure two fiducial marks. With two fiducial marks, the scale of the interior 
orientation is known already, so the centering of the fiducial marks in the 
individual  views  can be  performed  more  accurately.  The  next  images to 
measure will use the interior orientation results of the previously measured 
IO as approximation for the centering. 
Check if the displayed fiducial mark applies to the fiducial mark ID shown in 
the center part of  the viewer  window (e.g.  check the fiducial mark  index 
from  the Index  column  and  compare  this  to  the  displayed  fiducial  mark 
image). If the image has to be rotated, change the Scan Position in the 
"Main Window List View" (the manual interior orientation dialogs does not 
need to be closed for that). If no Scan Position is given at all, the center 
shows '?
‟ for each fiducial mark, select a fiducial mark ID to be measured in 
the  "Manual Interior Orientation" dialog and  subsequently measure the 
fiducial mark by left clicking in the corresponding fiducial mark image. 
To measure a fiducial mark, first a fiducial mark ID has to be activated for 
the  measurement.  Either  left  click  into  the  fiducial  mark  image  view,  or 
select a fiducial mark ID from the fiducial mark table in the "Manual Interior 
Orientation" dialog. The active view will be displayed with a red frame. 
To  pick  the  measurement  in  an  active  view,  left  click  into  the  correct 
position. A little cross will be placed to show the measured location. The 
fiducial mark ID in the center of the window will change to a green color to 
indicate, that this fiducial mark has already been measured.  
In some cases it might be easier to select a circle as measurement cursor 
for semi-automatic measurement and adjust its size so it fits to the fiducial 
mark - then, Instead of clicking into the image for a measurement, keep the 
left mouse button pressed and drag the circular cursor to its desired position. 
Semi-automatic measurement does not need to be activated to do that. 
For the semi-automatic measurement procedure it would be good enough 
to  measure  two  fiducial  marks  manually.  Before  that,  it  is  necessary  to 
activate Match Template in the extended dialog opened by clicking onto 
the Cursor Definition tool button. Change the template style (cross, circle, 
box) and the size / rotation of the template with the corresponding sliders. 
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit PDF
Redact tab on viewer empower users to redact and erase PDF text, erase PDF images and erase PDF pages online. Miscellaneous. • RasterEdge XDoc.
how to delete text in a pdf file; remove text from pdf
C# PDF Text Redact Library: select, redact text content from PDF
Free online C# source code to erase text from adobe PDF file in Visual Studio. How to Use C# Code to Erase PDF Text in C#.NET. Add necessary references:
pdf text watermark remover; delete text from pdf acrobat
Reference Manual ApplicationsMaster 
Page 216 
The template style and the  size should correspond to the element that is 
used  to  automatically  measure  the  fiducial  marks,  and  to  automatically 
center the two manual measurements. Usually, the dot is used to perform 
the semi-automatic measurement. 
To delete measurements select the fiducial mark from the fiducial marks list 
and  press the Delete  button. Or press Delete All to delete all measure-
ments. 
When all fiducial marks are measured, select the transformation type.  
 Parameters (Helmert 
 translations,  1  rotation,  1  scale):  This 
transformation  type  has  to  be  selected,  whenever  less  than  three 
measurements are existing (this type then is automatically selected). In 
all other cases, this type is only used for checking purpose - to get better 
information  on  film  deformations  through  residuals  at  fiducial  mark 
measurements.  
5  Parameters (2 translations, 1 rotation, 2 scales). This helps for a 
scanner that produces non-quadratic pixels. 
6 Parameters (Affine 
2, translations, 2 rotations, 2 scales). Generally 
this type should be used. It is the only transformation type that can cope 
with film distortions that show any affinity. 
Check  the  transformation  parameters,  especially  the  sigma  0. Sigma 0 
should normally correspond to 1/3 of a pixel (however, there is a threshold 
of 5 micron, so even if you have a smaller pixel size, it is hard to get any 
better than 5 micron). If your results are even worse, reasons might be of 
course  wrong  fiducial  mark  measurements  or  an  inadequate  camera 
calibration  or  poor  geometric  quality  (calibration)  of  the  scanner.  In  any 
case you should  be aware of the  effect,  which a  bad  interior  orientation 
would have on the triangulation result. 
If the IO results are approved, save the interior orientation with the Apply 
button. 
To load the next image to be processed, select it from the "Main Window 
List View". This image is directly loaded into the manual interior orientation 
dialog, which is still opened.  
Proceed  with  those  steps  until  all  interior  orientations  have  been  done. 
When finished, save the results  and quit  the user interface  with  the OK 
button. 
The interior orientation results are now written to the "Main Window List 
View". Orientations are finally written to the project file, by selecting Save 
from the File menu of the main dialog. 
C# HTML5 PDF Viewer SDK to view, annotate, create and convert PDF
setting PDF file permissions. Help C# users to erase PDF text content, images and pages online in ASP.NET. RasterEdge C#.NET HTML5
how to delete text from pdf with acrobat; how to delete text from pdf
C# PDF Image Redact Library: redact selected PDF images in C#.net
Same as text redaction, you can specify custom text to appear over the image redaction area. How to Erase PDF Images in .NET Using C# Class Code.
deleting text from a pdf; erase text in pdf document
Reference Manual ApplicationsMaster 
Page 217 
8.  Basics 
Exterior Orientation 
8.1. General Remarks 
ID_GINTRO 
Exterior Orientation is part of Inpho
‟s
software package and is designed to do 
the exterior orientations for aerial and satellite images. The orientation is done 
via  a  space  resection  of  aerial  images  or  via  calculating  rational  polynomial 
coefficients (RPCs) of satellite images by measuring 3D control points. 
The 3D control points can be either 
given by a control point list 
or  derived  by  digitizing  2D  points  in  a  georeferenced  digital  image 
(orthophoto or map) 
or a digital map delivered in a DXF file format. 
The  height  is  derived  from  a  DTM  which  is  needed  in  case  of  digitized  2D 
points.  The  space  resection  is  computed  with  an  integrated  robust  bundle 
solution.  The  RPC  values  are  computed  by  a  free  or  a  Keplerian  model  to 
describe the satellite path in the orbit.  
Exterior Orientation runs currently under Windows 2000 and Windows XP. 
For  new  users,  it  is  recommended  reading  first  the  section Working with 
Exterior Orientation 
Note: Exterior Orientation is hardlock protected. Starting without a hardlock, the 
program  runs  in demo mode  and  does  not  allow  saving  results  and  also 
corrupts slightly the display of the EO parameters
8.1.1.  Provision of Input Data 
To run Exterior Orientation various input data have to be provided: 
For projects with aerial images: the Inpho project file containing image and 
camera information 
For projects with  satellite images: the  Inpho project file containing  image 
and meta data information 
3D ground control points or georeferenced images (orthophoto or map) with 
DTM data 
How to C#: Special Effects
Erase. Set the image to current background color, the background color can be set by:ImageProcess.BackgroundColor = Color.Red. Encipher.
how to delete text in a pdf acrobat; remove text watermark from pdf online
Customize, Process Image in .NET Winforms| Online Tutorials
Include crop, merge, paste images; Support for image & documents rotation; Edit images & documents using Erase Rectangle & Merge Block function;
how to delete text in pdf using acrobat professional; delete text from pdf
Reference Manual ApplicationsMaster 
Page 218 
The following satellites are currently supported: 
Satellite 
Sensor 
Format 
Level 
IRS 1 C/D 
PAN/LISS/ WiFS  Eosat FST 
Oriented 
CartoSat-1 
(IRS P5) 
PAN 
GeoTIFF 
(Data in IKONOS 
format with 
metadata and 
RPCs) 
Raw 
Oriented 
Oriented 
Spot 1-4 
PAN/XI/XS 
Cap 
Eosat FST 
CCRS 
Raw, oriented 
Oriented 
Oriented 
Spot 5 
PAN/HI  
Dimap 
Raw, Oriented 
Landsat 4-5 
TM 
LGSWOG (CEOS) 
Eosat FST 
Nlaps 
Oriented 
Oriented 
Oriented 
Landsat 7 
ETM+ 
HDF 
Eosat FST 
LGSWOG (CEOS) 
Oriented 
Oriented 
Oriented 
IKONOS 2 
PAN/MSI 
Tiff / GeoTIFF 
Oriented 
Quickbird 2 
PAN/MS 
Tiff / GeoTIFF 
Raw, oriented 
Worldview 1 + 
PAN/MS 
Tiff / GeoTIFF 
Raw, oriented 
GeoEye 1 
PAN/MSI 
Tiff / GeoTIFF 
Oriented 
ALOS (PRISM, 
AVNIR-2) 
PAN/MSI 
Tiff / GeoTIFF 
1A, 1B1, 1B2 
(Restriction: 
RPC files  
required) 
Raw level:  
Normally, only sensor specific corrections have been made to images at this 
level.  Earth curvature and other geometric corrections have not been made.  
Radiometric corrections may have been made.  
Oriented level:  
Sensor  specific  corrections,  earth  curvature  corrections  and  possibly 
radiometric corrections have been made to images of this level.  The images 
normally have  been  oriented either  with  the  orbit  or  a  map  projection  using 
orbital parameters only.  The images of this level have not been rectified with 
ground control points or a digital terrain model.  
Note: 
Images of higher processing levels are not supported.  Images of higher levels 
have  normally  been  rectified  with  ground control  points  and/or  digital terrain 
.NET Imaging Processing SDK | Process, Manipulate Images
Provide basic transformation functions, like Crop, Rotate, Resize, Flip and more; Basic image edit function support, such as Erase Rectangle, Merge Block, etc.
delete text from pdf with acrobat; how to delete text in a pdf file
Reference Manual ApplicationsMaster 
Page 219 
models,  and  during  this  process,  the  original  geometry  of  the  image  is 
destroyed. 
Note
CartoSat meta files must be delivered in the IKONOS format. 
8.2. Working with Exterior Orientation 
ID_GSTART_selections 
This chapter gives a short explanation of the main features of the user interface 
and  an  outline  of  a  typical  workflow,  from  program  start  up  to  point 
measurement.  
8.2.1.  User Interface 
The  application  is  operated  via  a  graphical  user  interface  (GUI).  The  main 
window of the GUI contains three parts. 
Menu bar: Project handling, parameter settings and data import are controlled 
via the menu. For a detailed description see chapter Menu.  
Toolbar: The toolbar allows controlling the image to be oriented, to rotate 
images, to get information about images and measured points and to activate 
respectively  deactivate  certain  functions.  Details  can  be  found  in  section 
Toolbar
”. 
Map Window: Graphics interface to display on the left side: the selected aerial 
or  satellite  image  and  additionally  measured  photo  points  on  the  right  side: 
available control points and additionally orthophotos or digital maps  
Reference Manual ApplicationsMaster 
Page 220 
Furthermore  the  „Map  Window“  contains:  General  „Map  Window“  Tools:
Functions to handle the „Map Window“ like zooming, panning. For details see 
section G
eneral „Map Window“ Tools
Status Bar: Display of coordinates and progression of data import and export. 
Details can be found in section “
Status Bar
”.
8.2.2.  Workflow 
Different  typical  workflows  are  described  in  the  “
Tutorial  of  the  Exterior 
Orientation
”. 
8.3. Menu  
The main menu is shown belowAny of the menu commands can be chosen by 
clicking with the mouse or by pressing Alt + the underlined character (e.g. Alt 
+ P  opens the Project sub-menu). 
There are following menus: 
Project Menu 
Project  menu  commands  are  used  for  project handling,  i.e.  for opening  and 
saving existing Inpho projects and for displaying project information. 
Parameters Menu 
Parameters menu commands are used for parameter handling, i.e. for setting 
proper values for environmental and computational parameters. 
Data Menu 
Data menu commands are used for data handling: mainly for importing data like 
digital terrain models and orthophotos. 
Help Menu 
Help menu commands are used for on-line help. 
Language Selection 
The language for the user interface can be changed in the language menu. 
Reference Manual ApplicationsMaster 
Page 221 
8.3.1.  Project Menu 
The Project Menu provides a number of functions to administrate an Exterior 
Orientation session. 
8.3.1.1. Open Inpho Project 
ID_GPROJECT_OPEN 
Open Inpho Project opens a standard file selection box for selecting an Inpho 
project  file  (*.prj).  If  “
Exterior  Orientation
is  started  from  the 
“ApplicationsMaster”
GUI  with  a  loaded  project,  the  project  file  needed  by 
Exterior Orientation is passed to Exterior Orientation and you will not have to 
open it by yourself. 
8.3.1.2. Save Project 
ID_GPROJECT_SAVE 
Save Project saves the current state in the project file. (Results of the exterior 
orientation  computation,  parameter settings,  loaded  reference  images, height 
models).  Activating  the  computation  of  orientations  and  then  saving  of  the 
project will generate an additional text file in the project directory (name with 
time  stamp  e.g.  eo-20100517-152927_3644.log).  This  file  will  contain  the 
residuals of the measured points per image. 
8.3.1.3. Project Info 
ID_GPROJECT_INFO 
Project  Info opens the project 
information  window  and  gives  an 
overview  of  imported  files,  coordinate 
minimum  and  maximum,  list  of 
elements etc. 
8.3.1.4. Exit 
Exit terminates Exterior Orientation. If 
changes  were  made  to  the  project, 
Exterior Orientation asks for saving the 
project before it terminates. 
Reference Manual ApplicationsMaster 
Page 222 
8.3.2.  Parameters Menu 
Parameters  menu  is  used  to  display  and  edit  environment  and  computation 
parameters. Following functions are available: 
Display Map Window 
is used to modify the graphics attributes of the „Map Window“ and the fonts 
used in various lists. 
Units 
is used to define the metric and angular units and the number of decimals for 
output values 
Computation 
is  used  to  define  the  computation  parameters  for  satellite  images,  e.g. 
sensor model 
Miscellaneous 
is used for miscellaneous parameters, e.g. configuration of the logbook. 
8.3.2.1. Display Map Window 
The appearance of the „
Map Window
“ is user definable for the display on the 
monitor and for the output on a printer. To modify it, various parameters can be 
defined. The dialog boxes for screen and printer are identical. Fonts enable the 
selection of fonts for several output files.  
The  following  dialogs  are  used  to  modify  the  „Map  Window“  parameters:
General, Elements, DTM, Cursor; Footprints and Image Observations. 
8.3.2.1.1.  General 
ID_general
Documents you may be interested
Documents you may be interested