Steps to work through 
Select  the  “
Process  Type
” 
Point/vector  data    processing and define 
which “
Process steps
” should be performed:
- Tile: point data files (no lines) into regular patches (rectangles) which 
might  be  used  as  input  to  following  processing  steps.  The  tiles  are 
stored in  format ASPRS  LAS.  Additional informations to each tile  like 
processing  status,  editing  status,  file  names  are  managed  in  ESRI 
shape files (*.tpix.shp, *.tpix.shx, *.tpix.dbf, *.tpix_fli.dbf). A median filter 
and qualitative thin out algorithm might be added to eliminate redundant 
points. 
A Tile Navigator enables an easy selection of tiles for further processing 
steps like filter/classify, gap filling, surface modeling and contouring. 
Filter / Classify: point/vector data files. Predefined LIDAR or MATCH-T 
DSM filter strategies might be selected in order to separate ground and 
non-ground points. After the filtering a median filter and qualitative thin 
out algorithm might be used to eliminate redundant points. Working with 
Tiles,  the  filter  step  modifies  the  tiles,  no  new  files  are  written.  For 
SCOP++-filtering,  SCOP++  is  started  in  batch  mode.  So  an  installed 
SCOP++  version  and  a  SCOP++  LIDAR  license  is  necessary. 
Additionally  two  fast-filter  strategies  are  available.  To  use  the  fast 
filtering a DTMToolKit license is necessary. 
- Gap Filling: after classifying the point cloud it is possible to fill the gaps 
in the data set automatically. It is possible to define, that you want to use 
the ground points only. The input format can be LAS or the tile navigator 
format *.tpix.shp. 
The new “fill points” are written into the
ground layer 
(classification value=2) with a cla
ssification bit field encoding “Synthetic” 
(classification bit 5). The distance of the filled points can be defined. In 
DTMaster these points are visualized in an external layer. 
Delete text pdf acrobat professional - delete, remove text from PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# developers to use mature APIs to delete and remove text content from PDF document
delete text pdf; how to delete text from pdf
Delete text pdf acrobat professional - VB.NET PDF delete text library: delete, remove text from PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Programming Guide to Delete Text from PDF File
remove text from pdf preview; delete text in pdf file online
Reference Manual ApplicationsMaster 
Page 314 
Surface Modeling: interpolates  a  SCOP  DTM grid  file  from  different 
kind of input data. Mass points and vector lines might be integrated into 
the  DTM  generation.  The  resulting  DTM  has  an  hybrid  structure 
combining various input data types to one accurate and detailed model. 
The grid size, mean accuracy and limits and two different interpolation 
methods may be chosen.  
Contour lines generates a file(s) in format DXF or/and TIF. It contains 
isolines derived from one or several SCOP DTM file(s).  Contour lines 
might be generated with labels using two intervals or without any text 
notation.  To  use  Contour  line  generation  a  DTMToolKit  or  SCOP++ 
KERNEL license is necessary. 
The processing steps can be started separately or combined. For point cloud 
processing  it  is  recommendet  to  start  with Tile  and Filter/Classify. After 
checking the results, it is possible to fill gaps and to generate the DTMs and 
contour lines for selected tiles or for the complete area. If the data are tiled, the 
further process steps considers the neighboured tiles so the edges fit together. 
But it is also possible to use only Surface Modeling to generate a DTM from 
given terrain data (points and/or lines), or only Contour lines to get contours 
from a given DTM. 
Load the input files that should be processed. Multiple files can be loaded 
by  pressing Add....  To  remove  already  loaded  files  select  one  or  more 
entries from the file list and click the Remove button.  
View Area…
displays 
the extensions of all loaded files. 
Description of items 
MAIN TABLE 
The Main Table shows all files loaded into the DTMToolkit. 
To add or remove items from the table, use the buttons on 
the right side of the table. 
ADD... 
Click this button to open a file selection box to load one or 
.NET PDF Document Viewing, Annotation, Conversion & Processing
Redact text content, images, whole pages from PDF file. Annotate & Comment. Edit, update, delete PDF annotations from PDF file. Print.
how to delete text from pdf reader; how to delete text in a pdf file
C# PDF Converter Library SDK to convert PDF to other file formats
Allow users to convert PDF to Text (TXT) file. can manipulate & convert standard PDF documents in other external third-party dependencies like Adobe Acrobat.
how to delete text in pdf converter professional; delete text from pdf
Reference Manual ApplicationsMaster 
Page 315 
multiple files into the Main Table. Supported input formats 
are dependent on the selected processing step. 
REMOVE 
Select one or more entries from the Main Table and click 
the Remove button to delete them from the list. 
VIEW AREA 
Shows a schematic view of all loaded input files. The total 
area is hatched, surrounded by red vectors. The borders of 
the input files to be merged are represented by dark blue 
rectangles. If a Tile Manager File *.tpix.shp is selected, no 
view area is possible. 
Specify  the  object unit  of  the  input  data. Currently  [m], [feet (US)],  [feet 
(ISO)} and [ft (GEO)]. 
Description of items   
Define  the File prefix and Output directory path  for  the  output  files. 
DTMToolkit
” creates subdirectories for each tile. 
C# powerpoint - PowerPoint Conversion & Rendering in C#.NET
other external third-party dependencies like Adobe Acrobat. Using this .NET professional PowerPoint document conversion library PowerPoint to PDF Conversion.
delete text from pdf online; acrobat delete text in pdf
C# Word - Word Conversion in C#.NET
using other external third-party dependencies like Adobe Acrobat. Using this .NET professional Word document conversion library toolkit Word to PDF Conversion.
how to delete text from a pdf; how to erase text in pdf file
Reference Manual ApplicationsMaster 
Page 316 
FILE PREFIX 
Define a prefix which will be added to all file names gener-
ated during the tiling and filtering process. 
OUTPUT 
DIRECTORY 
PATH 
Use the Browse  (...) button to launch  a  selection box  in 
order to define the target directory. The files and directories 
generated with “
DTMToolkit
” are shown below.
The following directory structure will be generated: 
Using process step Tile 
In the  defined “Directory Path” all the tiles are stored in format LAS and 
additionally the Tile Manager files: 
<file_prefix_LeftLower_RightUpper>.las  : for each tile 
<file_prefix>.tpix.shp  
: Tile Manager file, ESRI shp file 
<file_prefix>.tpix.shx  
: ESRI shx file 
<file_prefix>.tpix.dbf  
: ESRI dbf file, meta data for tiles 
<file_prefix>.tpix_fli.dbf 
: ESRI dbf file, meta data for input 
<file_prefix>.tpix.dtm  
: overview SCOP DTM  
Using process step Filter/Classify after Tile 
The classification flags in the LAS files for the tiles are directly modified. 
Additionally for each processed tile a subdirectory is created with the name 
<file_prefix_LeftLower_RightUpper>. In each directory the report files from 
a filter/classify step are stored: 
Filter_dtmtoolkit.log   
: Report file from SCOP++ filtering 
Filter_dtmtoolkit.err   
: Error file from SCOP++ filtering 
Filter_dtmtoolkit.lim   
: stores the tile limits 
Filter_dtmtoolkit.cmf  
: command file for SCOP++ 
Filter_scop++.log   
: System SCOP++ report file 
<file_prefix_ LeftLower_RightUpper>_lastfilterstep.dtm : DTM used for the 
last classification step. Only for overview purpose. 
If a problem with the filtering occurs, please send to support@Inpho.de the 
Filter_* files. 
Note: If Filter/Classify is selected without using tiling before, the original 
file/files is/are modified 
Using process step Gap filling after Tile 
C# Windows Viewer - Image and Document Conversion & Rendering in
without using other external third-party dependencies like Adobe Acrobat. Using this .NET professional raster image and document conversion Convert to PDF.
pdf editor online delete text; erase pdf text online
VB.NET PowerPoint: VB Code to Draw and Create Annotation on PPT
other documents are compatible, including PDF, TIFF, MS free hand, free hand line, rectangle, text, hotspot, hotspot more plug-ins needed like Acrobat or Adobe
how to delete text from pdf document; how to remove text watermark from pdf
Reference Manual ApplicationsMaster 
Page 317 
The classification flags in the LAS files for the tiles are directly modified. In 
each  directory  <file_prefix_LeftLower_RightUpper> the report files from a 
“filling gap”
step are stored: 
gapfilling_dtmtoolkit.log 
: Report file from gap filling 
If a problem with the filling gaps occurs, please send to support@Inpho.de 
the gapfilling_* files and the dtmtoolkit.log file. 
Note: If Gap filling is selected without using tiling before, the original 
file/files is/are modified 
Using process step Surface Modeling after Tile 
For  each  processed  tile  a  subdirectory  is  created  with  the  name 
<file_prefix_LeftLower_RightUpper>.  In  each  directory  the  following  files 
after a Surface Modeling step are stored: 
<file_prefix>_surfacemodel.dtm   
: DTM file format SCOP DTM 
<file_prefix>_surfacemodel.dtm_bitmat.tif: overview DTM format TIF (1 bit) 
<file_prefix>_surfacemodel.dtm.txt  
: report file from DTM generation 
If  a  problem  with  the  DTM  generation  occurs,  please  send  to 
support@Inpho.de the <file_prefix>_ surfacemodel.dtm.txt file. 
Using process step Contour Lines 
For  each  processed  tile  a  subdirectory  is  created  with  the  name 
<file_prefix_LeftLower_RightUpper>.  In  each  directory  the  following  files 
after a Contour Lines step are stored: 
<file_prefix>_contours.dxf   
: Contour lines in format DXF 
<file_prefix>_contours.tif   
: Contour lines in format TIF (8 bit) 
Different Options are available for the Tile, Filter/Classify, Gap filling and  
Surface modeling modes. The settings are described in detail in the next 
sections of this documentation. 
To review the settings, a summary shows the input file path, type, mode 
and formats. 
Start the process by selecting Next. 
A summary of the parameters is listed in the log file. To visualize the log file 
press View Logfile. The log file is stored under Windows XP in directory: 
C:\Documents and settings\All Users\Application Data\Inpho\ApplicationsMaster5\Settings\ 
DTMToolkit.log
. Under Windows  Vista or Windows7 you find  the file under: 
C:\ProgramData\Inpho\ApplicationsMaster5\Settings\DTMToolkit
C# Excel - Excel Conversion & Rendering in C#.NET
using other external third-party dependencies like Adobe Acrobat. Using this .NET professional Excel document conversion library Excel to PDF Conversion.
pdf editor delete text; how to delete text from pdf document
VB.NET PDF: How to Create Watermark on PDF Document within
users need no external application plugin, like Adobe Acrobat. Add Image Watermark to PDF. Besides text, users also image__2.Save("C:\1-watermark.pdf") End If.
how to delete text in pdf file; erase pdf text
Reference Manual ApplicationsMaster 
Page 318 
11.2.1.  Tiling of Point Clouds 
Point clouds might be divided into handy working patches for further automatic 
or manual processing. Parameters like the size and amount of tiles have to be 
specified.  An  ESRI  shape  file  containing  the  structure  and  position  of  the 
created  tiles  and  additional  meta  data  will  be  generated  during  the  tiling 
process.  This  files  are  required  as  meta  information  for  the  following  filter 
process. 
Note: Vector data like break lines cannot be used as input data. The tiling 
works only on point cloud files! But it is possible to define the morphological 
data to be used for further processing like filtering and DTM generation. 
Note  The filtering process will always take into account one center tile and a 
certain portion of the 8 adjacent tiles to avoid wrong classification results at the 
tile borders. The number of points in one tile is restricted to 45 million points 
(more possible for tiling but not recommended in the workflow). 
Using  SCOP++  32bit  version  for  filtering: Up to 20 million points can be 
filtered in one step. Please make sure that the tile size is chosen in a way that 
the  amount  of  points  may  not  exceed  15  million  points  per  tile.  The 
approximated number of points per square meter can be determined utilizing for 
instance “DTMaster” or any  other visualization  tool. The software  checks  the 
amount of points in one tile and reports an error, if a tile includes more than the 
max. allowed points.  
Description of items 
Define the Reference pointTile size and Quantity of tiles per direction. 
A schematic overview about the project area and the defined tiles might be 
launched by pressing the View Area
button. 
A certain Name pattern for the tiles might be defined using the Name 
pattern editor 
Finallyredundant points may be eliminated to reduce the size of the point 
cloud. The Thin out routine utilizes the Minimum thinned out distance and 
the Maximum thin out distance and the specified Height tolerance as 
input parameters. 
Note: Point clouds must not be thinned out when a classification process should 
be applied afterwards. The classification step requires the full resolution of the 
input data. However, points might be thinned out when “only” a ground against 
Reference Manual ApplicationsMaster 
Page 319 
non ground point filtering should be done. The filtering process will require less 
time. 
REFERENCE 
POINT 
Key in the lower left corner of one map sheet Tile that will 
reference the complete tiling definition. If the Default button 
Reference Manual ApplicationsMaster 
Page 320 
is  clicked,  the  reference  point  is  automatically  set  to  the 
lower left corner of the rectangle combining all loaded input 
files (X = East, Y = North). 
SIZE  
Enter the size of each Tile (map sheet) defined in ground 
units.  If  the Default  button  is  clicked,  the  size  is 
automatically  set  to  the  complete  size  of  the  rectangle 
combining all loaded input files. 
QUANTITY  
PER DIRECT-
ION 
For  each  direction  (east,  west,  north,  south)  enter  the 
quantity  of  tiles  starting  at  the Reference Point.  If  the 
Default button is clicked, only 1 tile to the north and to the 
west  will  be  generated,  as  the  complete  rectangle 
combining all loaded input files is selected as one tile. 
VIEW AREA…
Shows  a  schematic  view  on  the  rectangle  combining  all 
loaded input files. The total area is hatched, surrounded by 
red vectors. The borders of the input files to be merged are 
represented by dark blue rectangles. 
Tiles (map sheets) are displayed as white rectangles 
starting from the Reference Point (green dot). 
NAME 
PATTERN 
Name Patterns can be used to automatically create output 
file names for the Tiles (map sheets). Name Patterns may 
include: 
Coordinate values (east, north) 
Incremental indices (east-west, south-north) 
Simple text 
The easiest way  to  define  a Name Pattern  is to  use the 
"Name Pattern Editor launched  by  the Edit (...)  button 
next  to the  pattern  text  field.    Refer  to  the  section  “
Split 
DTM Files
” for a detailed description of the "
Name Pattern 
Editor" 
Pattern fields can have the following values: 
e, n  =  index  number  east-west,  south-north 
(starting with %+field definition) 
cx, cy, ulx, uly, llx, lly = coordinate values (x, 
y) for the tile center, upper left corner or lower 
left corner (Starting with %+field definition) 
text = any descriptive text at any place in the 
pattern.  
Reference Manual ApplicationsMaster 
Page 321 
Field definitions have the following syntax: 
= starting a new field 
%0 = starting a new field padded with leading 
zeros  if the value  is  too  small  for  the  defined 
field width 
%03 = starting a new field padded with leading 
zeros  if the value  is  too  small  for  the  defined 
field width (3 digits). If the value to be displayed 
is larger than 3 digits the first digits are cut off. 
%03.2  starting  a  new  field  padded  with 
leading zeros  if  the  value  is  too  small for  the 
defined field width (3 digits), only showing the 
first digits cutting of the last 2 of the displayed 
value. 
e.g. project_%03eEast_%03nNorth_E%6.2ulx_N%6.2uly 
project(descriptive string) 
%03e  (index  number,  east-west,  three  digits 
with leading zeros) 
East(descriptive string) 
%03n (index number, south-north, three digits 
with leading zeros) 
North_E (descriptive string) 
%6.2ulx (x  coordinate  upper left  tile corner, 6 
digits, cutting off the last two digits, no leading 
zeros) 
_N (descriptive string) 
%6.2uly (y  coordinate  upper left  tile corner, 6 
digits, cutting off the last two digits, no leading 
zeros 
DEFAULT 
Clicking the Default button loads default values for the tile 
(map sheet)  definition.  One  single  tile  covering the whole 
area is defined. 
THIN OUT 
Eliminates redundant points in order to reduce the size of 
the  point  cloud.  The  thin  out routine utilizes the minimum 
and  maximum  thin  out  distance  and  the  specified  height 
tolerance as input parameters. 
Reference Manual ApplicationsMaster 
Page 322 
Note: Point clouds must not be thinned out when 
classification  process  should  be  applied  afterwards.  The 
classification  step  requires  the  full  resolution  of  the  input 
data. However, points might be thinned out when “only” a 
ground against non ground point filtering should be done. 
The filtering process will require less time.  
MINIMUM 
THINNED OUT 
DISTANCE 
MAXIMUM 
THINNED OUT 
DISTANCE 
The Minimum Thinned Out Distance defines the cell width 
for a median filtering. The  result is one  point in each cell 
generated with  a median filter. It can be combined with a 
qualified  filtering  by  defining  the Maximum Thinned Out 
Distance. 
Value used for the qualified thinning. 
Recommendation: not larger than 4*grid width proposed by 
MATCH-T DSM for the used generation and terrain type or 
the  average  point  spacing  of  the  LIDAR  data.  
The  parameter  defines  the  maximum  distance  to  an 
arbitrary  point  (radius).  So  it  is  possible  that  you  have 
2*max. distance between the resulting points after thinning. 
HEIGHT 
TOLERANCE 
Value used for the qualified thinning. 
Recommendation:  not  larger  than  2*height  accuracy 
(compare MATCH-T DSM log file: estimated internal height 
accuracy) or LIDAR data specification.  
11.2.2.  Point Cloud Filtering / Classification 
Point  cloud  files  produced  either  from  airborne  LIDAR  scanners  or  from 
MATCH- T DSM
” might be filtered / classified utilizing the predefined strategies 
provided by the “
DTMToolkit
”. Very large data sets divided in working patches 
might be processed in one run.  
The “
DTMToolkit
” is based on the technology of “
SCOP++ LIDAR
” which
offers 
quite  powerful  classification  and  filter  algorithms.  A  “
SCOP++  LIDAR
” 
installation and license has to be available to use the SCOP++ classification / 
filtering mode. Details about the theoretical background and the different kind of 
parameters  and 
option  provided  by  “
SCOP++  LIDAR
”  are  given  in 
the 
corresponding user manual. 
Using the fast filter methods a DTMToolKit license is necessary.These method 
is faster than the SCOP++ filter method but less accurate. 
Point clouds might either be classified in seven different classes (buildings, low 
medium 
high  vegetation,  ground,  below  ground,  unclassified)  with  the 
SCOP++  filter  method  or  separated  into  building,  ground,  low-  and  high 
vegetation points with the fast filter methods.  