Reference Manual ApplicationsMaster 
Page  63 
later will  be  referenced. A recommendation  is  to add the 
calibration date to the Camera ID . 
SENSOR TYPE The Sensor Type is specified when defining a new 
camera. The type cannot be changed later. The only way to 
correct a false definition consists in creating a new camera. 
The type determines which information has to be entered in 
the Calibration tab: 
Aerial Frame for analogue cameras 
CCD Frame for digital cameras 
Note: Line sensors (ADS40) are not to be entered in the 
camera editor! 
CAMERA 
BRAND 
For  analogue  cameras,  the  following  camera  brands  are 
available: 
RMK-A / RMK-TOP 
RC 10 / 20 / 30 
LMK 
UMK 
LC 10 
Custom (may be selected, if the camera brand 
is unknown) 
For  digital  cameras,  the  following  camera  brands  are 
available: 
DCS 660 
DigiCAM H22 / K14 
DIMAC 2 
DMC 
DSS 301 / 322 / 439 
Pictometry 2*4K / 3*2K 
AIC P20 / P25 / P45 / 65 
UltraCam-D (with all rotations) 
UltraCam-X (with all rotations) 
Custom (may be selected, if the camera brand 
is unknown) 
Remove text watermark from pdf - delete, remove text from PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# developers to use mature APIs to delete and remove text content from PDF document
how to delete text from pdf reader; how to delete text in pdf preview
Remove text watermark from pdf - VB.NET PDF delete text library: delete, remove text from PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Programming Guide to Delete Text from PDF File
remove text from pdf reader; delete text from pdf file
Reference Manual ApplicationsMaster 
Page  64 
EDIT 
BASIC 
CAMERA ID The Camera ID must be unique. With this ID, the photos later 
will be referenced. A recommendation is to add the calibration 
date to the Camera ID. 
SERIAL 
NUMBER 
Optionally, a serial number may be entered for the camera. 
SENSOR 
TYPE 
The Sensor Type is specified when defining the new camera. 
The type cannot be changed later. The only way to correct a 
false definition consists in creating a new camera. 
The type determines which information has to be entered in the 
Calibration tab: 
Aerial Frame for analogue cameras 
CCD Frame for digital cameras 
C# PDF Page Delete Library: remove PDF pages in C#.net, ASP.NET
console application. Able to remove a single page from PDF document. Ability to remove a range of pages from PDF file. Free trial package
how to edit and delete text in pdf file; delete text from pdf acrobat
C# PDF Password Library: add, remove, edit PDF file password in C#
String outputFilePath = Program.RootPath + "\\" Remove.pdf"; // Remove password in the input file and output to a new file. int
how to delete text in pdf using acrobat professional; how to erase text in pdf file
Reference Manual ApplicationsMaster 
Page  65 
Note: Line sensors (ADS40) and satellites are not to be entered 
in the camera editor! 
CAMERA 
BRAND 
The Camera Brand is internally connected with different default 
settings  and  templates.  For  Instance,  the  number  of  fiducial 
marks and their shape are determined by the related brand.    
GNSS 
ANTENNA 
OFFSET 
Enter the offset of the GNSS antenna with respect to the cam-
era‟s principal point. The offset in x, y and z refers to the camera 
co-ordinate  system  and  is  given  in  object  units.  If  the 
eccentricity is not known, Drift Correction has to be applied in 
the triangulation adjustment. 
Illustration: Definition of the antenna eccentricity with refer-
ence to the image coordinate system. 
CAMERA 
MOUNT 
ROTATION     
This  parameter  defines  the  rotation  of  the  image  coordinate 
system  with respect  to  the flight  direction of the aircraft.  The 
parameter is used to calculate the approximate kappa rotation 
from the strip azimuth and is therefore necessary for "Match- 
AT" projects. 
Mount Rotation = 0 deg (= Zeiss default) 
Mount Rotation = 180 deg (= Leica default) 
C# PDF bookmark Library: add, remove, update PDF bookmarks in C#.
Ability to remove and delete bookmark and outline entry.GetLocation()); Console.WriteLine("Text: " + entry.GetText NET Sample Code: Update PDF Document Outline
acrobat remove text from pdf; delete text pdf preview
C# PDF metadata Library: add, remove, update PDF metadata in C#.
Add metadata to PDF document in C# .NET framework program. Remove and delete metadata from PDF file. Also a PDF metadata extraction control.
remove text from pdf preview; erase pdf text online
Reference Manual ApplicationsMaster 
Page  66 
EDIT 
CALIBRATION (analog) 
FOCAL LENGTH 
Here  the  calibrated  focal  length  as  given  in  the 
calibration report of the used camera has to be entered. 
FIDUCIAL MARK 
COORDINATES 
DEFINED WITH 
RESPECT TO 
This  spin  box  compares  to  the  statements  in  the 
calibration report of the camera, to define the origin of 
fiducial mark coordinates. Possible origins are: 
PPS (Principal Point of Symmetry) 
PPA (Principal Point of Autocollimation) 
FC (Fiducial Center) 
PRINCIPAL POINT 
OF 
The Principal Point (PPS) also  known  as  the 
Principle  Point  of  Symmetryindicates the 
intersection of the  image plane with  a direct axial  ray 
passing  through  the  center  of  the  lens  system.  This 
assumes  that  the  focal  plane  is  perpendicular  to  the 
optical axis, but a parameter to correct for misalignment 
may be determined.  
The Principal Point of Autocollimation (PPA) can be 
thought as the foot point of the perpendicular from the 
center  of  the  lens  system  to  the  plane  of  focus  and 
represents the point which would be the ideal origin for 
a coordinate system on the image plane. 
The principal point's coordinates are used to calculate 
the  amount  of  correction  to  be  added  to  image 
measurements,  if  corrections  are  applied.  Necessarily 
the  lens  distortion  function  has  to  be  based  on  the 
C# PDF url edit Library: insert, remove PDF links in C#.net, ASP.
Able to insert and delete PDF links. Able to embed link to specific PDF pages. Easy to put link into specified position of PDF text, image and PDF table.
how to erase text in pdf; how to copy text out of a pdf
C# PDF File Compress Library: Compress reduce PDF size in C#.net
NET framework. Remove bookmarks, annotations, watermark, page labels and article threads from PDF while compressing. C# class demo
remove text watermark from pdf online; pull text out of pdf
Reference Manual ApplicationsMaster 
Page  67 
definition of PPS. 
Depending on the selection for the origin of the fiducial 
mark coordinate system  (PPA,  PPS, FC), only one or 
both  edit  boxes are  activated. Entries  deactivated  are 
considered having an offset of 0.0 mm. 
Note: Each change of the PPA coordinates demands a 
re-measurement of all  image  points which  have been 
acquired (manually or automatically) before because all 
image  coordinates  refer  to  the  principal  point  of 
autocollimation.  No automatic update of existing coor-
dinates exists!!! 
Possible centering of the coordinate system defined by the fiducial marks: 
FC 
Fiducial Center: The origin of the fiducial mark coordinates. 
PPA 
Principal Point of Autocollimation: The point on the image 
plane which is perpendicularly below the projective center of 
the lens. 
PPS 
Principal Point of Symmetry: The point on the image plane 
where  the  optical  axis  of  the  lens  intersects  the  image 
plane. 
For “
ApplicationsMaster
” 
products the image coordinate system always refers 
to the Principal Point of Autocollimation (PPA). Therefore, the camera editor in 
the project definition tool allows the entry of coordinates of PPA and PPS with 
C# PDF Convert to Word SDK: Convert PDF to Word library in C#.net
key. Quick to remove watermark and save PDF text, image, table, hyperlink and bookmark to Word without losing format. Powerful components
erase pdf text; how to delete text in pdf file
C# PDF Text Redact Library: select, redact text content from PDF
Text: Delete Text from PDF. Text: Replace Text in PDF. Image: Remove Image from PDF Page. Image: Copy, Paste Edit, Delete Metadata. Watermark: Add Watermark to PDF
pdf text remover; how to delete text from pdf document
Reference Manual ApplicationsMaster 
Page  68 
respect to the  point that fiducial  mark  coordinates  refer to  (center of fiducial 
mark co-ordinate system FC). 
There are three cases that must be considered here. The calibration report of 
the camera states in which of the following cases the fiducial mark system is 
defined. 
The coordinates of the fiducial marks refer to PPS: 
For PPS enter (0, 0) and for PPA the total displacement between PPS and 
PPA (d=ppa-pps). (usually cameras calibrated by ZEISS Oberkochen)
The coordinates of the fiducial marks refer to PPA: 
For PPA enter (0, 0) and for PPS the total displacement between PPS and 
PPA (d=pps-ppa). (usually USGS calibration report)
The coordinates of the fiducial marks refer to FC: 
For PPA enter the displacement between FC and PPA (d = ppa - fc) and for 
PPS the displacement between  PPS and FC (d=pps-fc) (usually Leica 
calibration report). 
EDIT 
CALIBRATION (CCD) 
Due to the fact, that so far no standard is specified for calibration reports of 
digital cameras by the International Society for Photogrammetry and Remote 
Sensing  (ISPRS),  the  camera  calibration  editor  used  with  the 
ApplicationsMaster
is designed to have most flexibility. 
E.g. for Z/I imaging DMC cameras a camera definition is already existing by 
default.  Among  others,  this  camera  produces  "ideal"  images  by  resampling 
algorithms that correct all distortions and offsets automatically. So images are 
free of any distortion and all cameras of that brand have the same camera 
calibration! So it is not necessary to define further DMC cameras here. 
Some camera manufacturers may not provide all data that is necessary to be 
entered here, because they use their own standards (e.g. pixel origin). It is very 
important to have a detailed correct definition of the sensor to avoid bad results 
(shifts,  eliminations...).  If  necessary  ask  the  manufacturer  for  information  on 
those necessary parameters! 
C# PDF Text Highlight Library: add, delete, update PDF text
etc. Able to remove highlighted text in PDF document in C#.NET. Support to change PDF highlight color in Visual C# .NET class. Able
how to delete text in a pdf acrobat; erase text from pdf file
Reference Manual ApplicationsMaster 
Page  69 
FOCAL LENGTH 
Here  the  calibrated  focal  length  as  given  in  the 
calibration report of the used camera has to be entered. 
SENSOR SIZE 
The size of the CCD sensor is defined by the amount of 
pixels in row and column direction. 
height = number of rows 
width = number of columns 
 pixmap  clarifies  the  shape  of  the  sensor  (squared, 
portrait or landscape format). 
PIXEL SIZE 
To be able to use cameras with non squared pixels, the 
pixel size is defined in row (up = height) and column (left 
= width) direction. In most cases, cameras have squared 
pixels so that the same value for height and width can be 
entered. 
SENSOR 
COORDINATE 
SYSTEM 
Some calibration reports show principal point offsets in 
pixel coordinates. If so, activate this radio button to be 
able  to  enter  PPA  or  PPS  in  the  sensor  coordinate 
Reference Manual ApplicationsMaster 
Page  70 
THE REFERENCE 
IS AT THE … OF 
PIXEL  
system. 
Usually the pixel reference is either 
the centre of pixel or 
the upper left corner of pixel 
A correct definition is necessary to correctly define the 
principal point offsets.  A shift of  half  a pixel  may have 
considerable impact on results! 
IMAGE COOR-
DINATE SYSTEM 
Instead of working with the pixel coordinate system, the 
principal point coordinates can be entered with reference 
to the image coordinate system. Which system is to be 
used depends on the information given in the calibration 
protocol. 
ORIENTATION OF 
IMAGE 
COORDINATE 
SYSTEM 
Usually the orientation of the image coordinate system is 
defined  with  the  X-axes  pointing  in  flight  direction.  A 
correct definition is necessary for a correct rotation of the 
images.  If in the "Multi Photo Measurement" "Block 
Overview" dialog, images seem to have a wrong 
rotation, change this parameter! 
PRINCIPAL 
POINTS OF 
See  the  definitions  of  principal  points  in  the  previous 
paragraph "Edit - Calibration Analogue". 
For  digital  cameras,  principal  point  offsets  often  are 
defined in (sub-)pixel coordinates referring to the upper 
left corner of the sensor. It is important to also consider 
the above mentioned Pixel Reference  (center /  upper 
left).  
The graphical view next to the input boxes shows arrows 
indicating the coordinate axes of  the image coordinate 
system in red (x, y) and the coordinate axes of the pixel 
coordinate system in blue (row r, column c). The location 
of  PPA  and  PPS  is  displayed  in  a  scaled  view.  If 
PPA=PPS they are displayed in a black color. 
Example: 
Calibration report: 
rows=20 / columns=10 
pixel size = 12 µm 
PPA/PPS  referring  to  physical  image 
center (intersection of lines connecting 
the outer corners of the sensor 
upper 
left  corner  of  upper  left  pixel  /  lower 
right corner of lower right pixel...) 
Reference Manual ApplicationsMaster 
Page  71 
PPA: x=0.01 mm / y=0.005 mm 
PPS: x=0.0 mm / y=0.0 mm 
Entered parameters
pixel reference: upper left  
sensor height=20 / width=10 
pixel height=12um / width=12um 
PPA: x= 5.83 pix / y= 9.58 pix 
PPS: x= 5.0 pix / y= 10.0 pix 
Alternatively entered
pixel reference: center 
sensor height=20 / width=10 
pixel height=12um / width=12um 
PPA: x= 5.33 pix / y= 9.08 pix 
PPS: x= 4.5 pix / y= 9.5 pix 
EDIT 
FIDUCIAL MARKS (analogue cameras only) 
ADD 
If no Camera Brand has been defined, the Preset function 
might not work as desired. The Add button is then used to 
add fiducial mark entries to the fiducial mark table. 
REMOVE 
Select one or more fiducial marks from the table and press 
the Remove button to delete fiducial mark definitions. 
Reference Manual ApplicationsMaster 
Page  72 
PRESET 
If Preset is clicked, the fiducial mark table is automatically 
initialized  with  a  number  of  fiducial  mark  entries 
corresponding to the specified Camera Brand
COORDINATE 
SYSTEM 
The  coordinate  system  rotation  is  basically  used  for  the 
automatic scan rotation detection with RC cameras. Usually 
the rotation is 0 deg (x pointing to the right). 
For  the  automatic  scan  rotation  detection,  the  system 
needs a reference between the fiducial mark name and the 
manufacturer  index  (e.g.  manufacturer  index  III  refers  to 
fiducial  mark  name  3).  Especially  with  US  calibration 
reports,  the  manufacturer  index  is  not  the  same  as  the 
calibrated name (e.g. III refers to fiducial mark 1). So it is 
necessary  to  define  the  orientation  of  the  coordinate 
system. 
The manual interior orientation dialog will show the fiducial 
mark  manufacturer  index  (if  in  the  "Camera Editor",  the 
rotation is set correctly) to be able to easily check if correct 
fiducial marks were measured. 
Here, two examples of a camera calibration report:  
The  sketches  refer  to  an  RC  and  RMK  TOP 
camera calibrated by USGS (the IDs of fiducial 
marks do  not  correspond to  the  manufacturer 
codes, but the rotation of the image coordinate 
system is given!).  