Reference Manual ApplicationsMaster 
Page  73 
Compare  the  sketch  in  the  calibration  report 
with  the  graphical  view  of  the  fiducial  mark 
definitions  in  the  fiducial  mark  dialog,  they 
should look the same. 
The manual interior  orientation  tool indicates  whether  the 
assignment between fiducial marks and calibration indexes 
are correct. 
TABLE  
NAME, X, Y 
The table shows all fiducial mark IDs with their specified x 
and y image coordinates. Values can directly be edited in 
the  table  cells.  Changes  to  the  fiducial  mark  table  are 
immediately displayed in the graphical view. Definitions that 
do not make sense or duplicate definitions are displayed in 
red color. 
Delete text pdf document - delete, remove text from PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# developers to use mature APIs to delete and remove text content from PDF document
how to delete text in pdf acrobat; delete text pdf
Delete text pdf document - VB.NET PDF delete text library: delete, remove text from PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Programming Guide to Delete Text from PDF File
how to delete text from a pdf in acrobat; remove text watermark from pdf
Reference Manual ApplicationsMaster 
Page  74 
EDIT 
DISTORTION 
DISTORTION 
CORRECTION 
TYPE 
By  default,  no  distortion  correction  is  taken  into  account 
when  creating  a  new  camera.  However,  if  distortion 
corrections  are  included  in  the  calibration  protocol,  it  is 
really  recommended  changing  this  setting  to  the 
appropriate option. Otherwise, the results of any operation 
can be degraded significantly, if great distortion values are 
neglected.  
Depending  on  the  calibration  report,  either  a radial 
distortion  table or distortion  coefficients are given. In 
reports  that  contain  both  types,  coefficients  should  be 
utilized  because  they  model  the  sensor  distortion  more 
accurate. 
Distortion grid models representing the distortion of the 
whole sensor area with the aid of a distortion value raster 
are becoming more and more important. The camera editor 
provides  an  import  function  to  lead  Intergraph  distortion 
grids. The bundle block adjustment program Bingo creates 
VB.NET PDF Page Delete Library: remove PDF pages in vb.net, ASP.
VB.NET PDF - How to Delete PDF Document Page in VB.NET. Visual Basic Sample Codes to Delete PDF Document Page in VB.NET Class. Free
remove text from pdf acrobat; delete text from pdf
C# PDF Page Delete Library: remove PDF pages in C#.net, ASP.NET
C#.NET PDF Library - Delete PDF Document Page in C#.NET. Provide C# Users in C#.NET. How to delete a single page from a PDF document.
online pdf editor to delete text; pdf text watermark remover
Reference Manual ApplicationsMaster 
Page  75 
also as an option a distortion grid which is identical with the 
Intergraph grid.  
MATCH-AT
” and “
inBLOCK
” 
offers the option to perform a 
camera  self-calibration  during  an  aerial  triangulation  in 
order  to  determine  a  distortion  grid.  The  self-calibration 
results  are  stored  into  a  new  camera  called  <camera-
calibrated>  inside  the  project file. If  the  triangulation  has 
been  processed  with  self-calibration  applied,  this  new 
camera has to be assigned to all photos to be able to go on 
with further steps like orthophoto generation, etc.. This grid 
might be exported  to the Intergraph /  Bingo format  using 
the export function.  
Provided that a self-calibrated camera is available, the Grid 
distortion entry can be chosen. In contrast to the Table and 
Coefficients option, no extra information concerning the 
mathematical definition is given. All correction values  are 
handled inside the software. 
VIEW 
Clicking  on  this  button  launches  the 
“3D  Distortion 
Correction  Plot”
being  used  to  visualize  the  sensor 
distortions in a three-dimensional space. 
COEFFICENTS If coefficients are to be entered, fill the K0...K7 and P1...P4 
boxes  with  the  values  given  in  the  camera's  calibration 
report.  
The coefficients refer to the formulas used by the USGS. In 
calibration  protocols  based  on  other  standards,  formulas 
are employed which have to be checked carefully whether 
they can be transferred or adapted to the USGS standard.   
Inpho splits the radial distortion into X- and Y-direction 
component.  Combining both parts to one radial distortion 
parameter (X = Y = 
R
/
Sqrt(2)
), leads to: 
(Note: More coefficients are possible. This formula relates 
directly to the Inpho  definition.) 
For Instance, the ISPRS approach takes the principal point 
of  symmetry  (here:  r
0
 into  account.    Furthermore, 
substituting K
= 0, K
= A
1
, K
= A
2
, etc. results in: 
As Inpho   software  performs  the  distortion  correction  on 
C# PDF Text Extract Library: extract text content from PDF file in
Free online source code for extracting text from adobe PDF document in C#.NET class. Ability to extract highlighted text out of PDF document.
delete text pdf acrobat; how to delete text from a pdf
VB.NET PDF Text Extract Library: extract text content from PDF
SharePoint. Extract text from adobe PDF document in VB.NET Programming. Extract file. Extract highlighted text out of PDF document. Image
how to erase in pdf text; how to delete text in pdf document
Reference Manual ApplicationsMaster 
Page  76 
image coordinates being reduced to the principal point of 
symmetry,  i.e.  r
=  0, the following equation also  directly 
relates to the formulas implemented in the 
Camera Editor
dialog:  
If coefficients refer to different formulas, they must not be 
entered. 
TABLE  
- LINEAR 
- ANGULAR 
If radial distortion values are to be entered into a distortion 
table, the selection box allows to enter the radius either as 
linear  distance  with  PPS  as  center  (e.g.  European 
calibration reports) or as angular distance from the lens and 
the  optical  axis  (e.g.  US  American  calibration  reports). 
TABLE  
- DISTANCE                                                
STEPS 
In a radial distortion table, if a linear (instead  of angular) 
definition  is  selected,  the Distance Step  may  be  set  to 
automatically  fill  the  table  with  rows  when  pressing  the 
Preset button. The specified value will be the radial interval 
between two definitions. 
GRID 
An Intergraph distortion grid (or Bingo grid with the same 
structure)  might  be  assigned  to  the  camera  using  the 
Import function. The dimension of an available grid is given 
in  rows  and  columns.  The Export  function  allows 
converting an Inpho grid into an Intergraph grid structure.  
C# PDF insert text Library: insert text into PDF content in C#.net
C#.NET PDF SDK - Insert Text to PDF Document in C#.NET. This C# coding example describes how to add a single text character to PDF document. // Open a document.
how to remove highlighted text in pdf; delete text from pdf preview
C# PDF Convert to Text SDK: Convert PDF to txt files in C#.net
All text content of target PDF document can be copied and pasted to .txt files by keeping original layout. C#.NET class source code
remove text from pdf; how to delete text from a pdf reader
Reference Manual ApplicationsMaster 
Page  77 
ADD 
The Add  button  is  used  to  add  distortion  entries  to  the 
distortion  table.  The  radius  is  automatically  incremented. 
REMOVE 
Select  one  or  more  distortion  entries  from the  table  and 
press the Remove button to delete the definitions. 
PRESET 
If Preset  is  clicked,  the  distortion  table  is  automatically 
initialized  with  distortion  entries  corresponding  to  the 
selection Linear / Angular.  The  distortion  values 
themselves  will  be  set  to  0.0  micron.  The  radius  is 
initialized to 0, 10, 20...150mm for linear tables and to 0, 
7.5, 15.0, 22.7, 30.0, 35.0, 40 deg. 
IMPORT 
Allows  loading  a  text  file  containing  containing  linear  or 
angular distances and calibrated distortion values. 
TABLE 
- LINEAR 
- ANGULAR 
DISTANCE 
Depending  on  the  selection, Linear / Angular,  the  table 
shows  either  rows  for  distortion  value  definitions  with  a 
linear  radius  (unit  mm!)  or  with  an  angular  radius  (unit 
degree!). 
TABLE 
DISTORTION 
The distortion values themselves can directly be entered / 
edited  in  each  table  cell.  Be  sure  to  enter  the  mean 
(average) distortion values given in the camera's calibration 
report.  
Note, that the unit for distortion values is micron (um)! 
C# PDF metadata Library: add, remove, update PDF metadata in C#.
C#.NET PDF SDK - Edit PDF Document Metadata in C#.NET. Allow C# Developers to Read, Add, Edit, Update and Delete PDF Metadata in .NET Project.
delete text in pdf file online; how to delete text from pdf
C# PDF Text Search Library: search text inside PDF file in C#.net
C#.NET. C# Guide about How to Search Text in PDF Document and Obtain Text Content and Location Information with .NET PDF Control.
erase text from pdf; pdf editor delete text
Reference Manual ApplicationsMaster 
Page  78 
3D Distortion Correction Plot 
3D DISTORTION 
CORRECTION  
PLOT 
This dialog visualizes the lens distortion of the camera 
using a 3D plot. It may help to get an impression how 
much the distortion influences the image coordinate 
measurement.  
The distortion plot can be rotated (keep left mouse button 
pressed + mouse movements) in all directions. 
DISPLAY BOX 
- FILLED MESH 
- WIRE FRAME 
The representation of the distortion plot is selectable via 
the display box.  A Filled Mesh visualization as well as a 
3D Wire Frame image are available.  
OPTION:  
DISTORTION 
Activate or deactivate the distortion visualization  
OPTION: 
DISPLACEMENT 
VECTORS 
Activate or deactivate the displacement vector 
representation. Each displacement vector illustrates the 
amount of distortion at one specific grid point and the 
distortion direction. Red vectors point outwards, blue 
vectors point inwards.  
V - VECTOR 
Manage the magnification of the displacement vectors via 
the V-Vector slider and the resolution selection box. 
Z - FACTOR 
Control the extension of the displacement plot in vertical 
direction using the Z-Factor slider and the Resolution 
selection box. 
Reference Manual ApplicationsMaster 
Page  79 
EDIT 
COMMENT 
COMMENT 
Enter  general  remarks  and  additional  information  on  a 
certain  camera,  e.g.  the  date  of  calibration,  operators 
name... 
LAST CHANGE 
Shows  the  date  and  time,  the  camera's  calibration 
parameters were last edited with the "Camera Editor". 
4.3.1.1. Digital Camera Setup - Standard Considerations 
At the moment, there are no standards for calibration reports of digital cameras. 
This is why often users are confused, what parameters to enter into software 
products. Read this chapter carefully.  
Questions that need to be answered are the following: 
What is the calibrated focal length? 
What is the sensor size in pixels? 
What is the pixel size? 
This is standard calibration information. The following data needs to be checked 
carefully, as definitions may vary: 
Principal points
Often  for  digital  cameras  only  one  principal  point  is  calibrated.  So  the 
question  to be answered  is, if the calibration report shows  PPA or PPS. 
Especially, PPA is critical as it is the reference to all image measurements. 
If PPA is not entered correctly, this will result in a shift of the triangulation 
results. There are two ways of entering the principal point offset: 
In the sensor coordinate system: 
To enter the principal point in pixel coordinates, it is necessary to know 
the reference. The reference might be either the center of a pixel or the 
upper left corner of a pixel. If the reference is not given correctly, the 
principal point offset will be wrong by half a pixel, which again results in 
a shift of the triangulation results. 
Reference Manual ApplicationsMaster 
Page  80 
In the image coordinate system: 
If the principal point offset is given in the image coordinate system, then 
it is necessary to know the rotation of the image coordinate system in the 
digital images. Is positive x pointing to the left or right, up or down? Note 
that also the exterior orientation parameters (e.g. IMU data) is referring 
to the image coordinate system! As a standard we recommend to have 
IMU  data  and  a  camera  calibration  always  referring  to  an  image 
coordinate system with positive x in flight direction. 
Lens Distortion 
The  lens  distortion  of  digital  cameras  usually  is  either  given  as  a  radial 
distortion or as coefficients of a correction formula. 
The figures above show left a camera with distortion that cannot be defined 
just with a symmetric radial table. Here coefficients or a correction grid is the 
only solution. The camera on the right shows a symmetric radial distortion 
that could be described by a radial distortion table. 
Radial distortion tables: usually  sufficient  for  analogue  cameras  or 
specially designed digital photogrammetric cameras. 
Distortion coefficients:  can  define  non-symmetric  lens  distortion.  Here, 
however,  it  is  extremely  important  to  know  the  correction  formula,  the 
coefficients are referring to.  
The Inpho 
Camera Editor
” expects  coefficients referring to the  following 
formula (according to USGS standards):     
 (radial) 
(optional - decentering) 
Reference Manual ApplicationsMaster 
Page  81 
In calibration reports, the formula of the radial component often is given for 
x=y, the coefficients would still apply: 
In special cases, the correction formula to which the radial coefficients are 
referring to are pointed out in the calibration report as follows. Comparing 
this to the Inpho definition: K0 = 0.0, K1=A1, K2=A2 
Other calibration reports may define the distortion correction as follows: 
Here, R0 is meant to be the offset of the principal point of symmetry (PPS) 
all  radial  distortions  are  referring  to.  As  Inpho  internally  delivers  image 
coordinates already corrected for PPS into the distortion correction routines, 
also  this  formula  would  apply  to  our  definitions  with:  K0  =  0.0,  K1=A1, 
K2=A2. 
Example for an UltraCam definition (see also chapter 14.1.3) 
Rotations: 
UltraCAM
images  may  be  used  at  different  levels.  Most  common  are  LV2 
images and LV3 images. So to speak LV2 is  the raw format of the camera, 
where LV3 is the post-processed imagery. During post-processing, the Vexcel 
software allows to rotate the images. This lately caused some confusion with 
interior orientation matrices on photogrammetric software in combination  with 
appropriate Kappa orientation angles.  
There are various possibilities to cope with this issue. Inpho
‟s
proposed way is 
to have a separate camera definition for each image rotation, always assuming 
the image coordinate system‟s x
-axis is pointing IN flight direction. 
In the following find the documentation of the four camera definitions used with 
UltraCam rotations. Pixel reference is always the upper left corner of a pixel. 
x-down 
= LV2 
row 
co 
Width 
11500 
PPA  3750 
5750 
0.0 
0.0 
Height 
7500 
PPS  3750 
5750 
0.0 
0.0 
columns 
r
o
x-right 
row 
col 
Width 
7500 
PPA 
5750 
3750 
0.0 
0.0 
Height 
11500 
PPS 
5750 
3750 
0.0 
0.0 
x-up 
row 
col 
Width 
11500 
PPA 
3750 
5750 
0.0 
0.0 
Height 
7500 
PPS 
3750 
5750 
0.0 
0.0 
x-right 
row 
col 
Width 
7500 
PPA 
5750 
3750 
0.0 
0.0 
Height 
11500 
PPS 
5750 
3750 
0.0 
0.0 
Reference Manual ApplicationsMaster 
Page  82 
These  are  the  standard  camera  definitions  with  the  principal  point  being 
calibrated  to  align  with  the  center  of  the  sensor.  Be  aware  to  select  the 
appropriate camera definition for your specific project. 
Principal Points
UltraCAM cameras are now delivered with a calibration report as the images 
showed larger principal point offsets. As calibration reports on digital cameras 
still  are  not  standardized,  you  will  find  an  explanation  how  to  use  a  Vexcel 
calibration report with the Inpho camera editor.  
The Vexcel calibration report refers to the following image setup: 
The  Vexcel  report  shows  the  image  coordinate  system  not  rotated  IN  flight 
directions,  which  is  rather  uncommon.  To avoid  setting  up  a  camera mount 
rotation for “
MATCH-AT
or to avoid misunderstandings about Kappa rotations, 
it is much easier to have image x defined IN flight direction (most of the IMU 
processing software packages assume x pointing in flight direction / Kappa = 
angle between image X and object East). 
This corresponds to a more suitable camera setup proposed by Inpho: 
Vexcel: 
PPA X= +0.123 
PPA Y= -0.345 
PPA X = +0.345 
PPA Y = +0.123 
Documents you may be interested
Documents you may be interested