opening pdf file in asp.net c# : How to erase text in pdf file software application project winforms html azure UWP jacsat_authguide1-part410

11 
template will ensure proper formatting and will facilitate review. It will allow authors and 
Editors to estimate the publication length of Communications at submission. Authors will be 
required to modify Communications that exceed the four-page limit at the page proof stage. 
All graphics and tables must be placed in the Communication template near the point of first 
mention in the text of the manuscript (not grouped at the end of the document). 
Articles. Use of the template for Articles is strongly encouraged but is not required (use of the 
template for Communications is mandatory). If an author chooses not to use a template to 
prepare an Article, only Times and Symbol fonts and 1.5 or double line spacing should be used. 
Other fonts may cause problems when the PDF files used for review are created. Also, if the 
template is not used, the document mode or its equivalent in the word-processing program 
should be used; i.e., files should not 
be saved in ³Text Only´ (ASCII) mode. 
If a non-Western 
version of word-processing software is used to prepare the manuscript, the file should be saved 
in rich-text format (RTF). 
Graphics and tables must be placed within the Article manuscript file near the point of first 
mention in the text. 
General Considerations. All files must be saved with U.S. Letter page-size (in the Page Setup 
settings of the word-processing application) before submission on the Web. Authors should 
consult recent issues of the Journal and The ACS Style Guide, 3rd ed.; American Chemical 
Society: Washington, DC, 2006, for further format guidance.  
Authors are required to provide a word processing file of their manuscript. Authors may provide 
their own manuscript PDF file along with the manuscript file or provide the manuscript file only 
and allow ACS to convert it to PDF. When creating the PDF files for submission (required for 
the manuscript and cover letter if they are furnished in a file type other than Microsoft Word), it 
is essential that all fonts be embedded within the PDF file. All characters must be correctly 
represented throughout the manuscript: for example, 1 (one) and l (ell), 0 (zero) and O (oh), x 
(ex) and × (times sign), and 
(
prime) and ¶ (apostrophe). The
Symbol font should be used for all 
Greek letters and math symbols. 
Any author who is not fully fluent in idiomatic English is urged to obtain assistance with 
manuscript preparation from a fluent colleague or through a paid editing service. Manuscripts 
with grammar or language usage deficiencies are handicapped during the scientific review 
process and may be returned to the author for rewriting before peer review or before acceptance. 
Assistance with Improving Your Manuscript. Authors professional assistance with improving 
the English, figures or formatting in their manuscript before submission. ACS ChemWorx 
Authoring Services can save you time and improve the communication of research in your 
manuscript. You can learn more about the services offered at http://es.acschemworx.acs.org. 
Using TeX/LaTeX.  Authors who submit manuscripts composed in TeX/LaTeX must submit a 
PDF file of the manuscript along with the native TeX/LaTeX manuscript package as a ZIP 
Archive. Use of the freely available achemso style package to help prepare your submission is 
strongly encouraged. The achemso package provides the official macros (achemso.cls) and 
BibTeX styles (achemso.bst and biochem.bst) for submission to ACS journals. The package and 
instructions are available from CTAN, the Comprehensive TeX Archive Network. For complete 
How to erase text in pdf file - delete, remove text from PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Allow C# developers to use mature APIs to delete and remove text content from PDF document
delete text pdf; pull text out of pdf
How to erase text in pdf file - VB.NET PDF delete text library: delete, remove text from PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Programming Guide to Delete Text from PDF File
remove text watermark from pdf; how to delete text in pdf using acrobat professional
12 
information on submitting TeX/LaTeX files, see Preparing and Submitting Manuscripts Using 
TeX/LaTeX. 
Table of Contents Graphic. The Journal features a Table of Contents (TOC) that contains a 
graphic presentation for each Communication and Article entry, in addition to the title and author 
list. Authors are required to submit a graphic for the TOC that, in conjunction with the 
manuscript title, is meant to convey to the reader the essence of the work and thereby capture the 
reader¶s attention.
It may be a key structure, reaction, equation, concept, or theorem, etc., or an 
ingenious representation thereof, that is discussed in the manuscript. The use of color to enhance 
the visual appeal of the TOC graphic is encouraged. The TOC graphic must appear on the last 
page of the Communication or Article manuscript file. 
See the µ
Artwork
¶ section for instructions
for preparing the TOC graphic. Authors are 
encouraged to examine the Table of Contents in a current issue for appropriate examples, or visit 
the JACS Web site. The TOC graphic is subject to approval by the Editor. 
Title. The title should accurately, clearly, and concisely reflect the emphasis and content of the 
paper. Series or part numbers 
may not be used, nor may the words ³Novel´ or ³First´ appear
in 
the title. Acronyms and abbreviations are not permitted in manuscript titles, unless they are 
broadly familiar to readers in all disciplines of chemistry. 
Author List. Include as coauthors all those who have made substantial contributions to the work. 
Use first names, initials, and surnames (e.g., John R. Smith). Do not use only initials with 
surnames (e.g., J. R. Smith), because this causes indexing and retrieval difficulties and interferes 
with unique identification of an author. Deceased persons who meet the criteria for inclusion as 
coauthors should be so included, with an Author Information note indicating the date of death. 
Do not include professional or official titles or academic degrees. At least one, or optionally 
more than one author must be designated with an asterisk as the author(s) to whom reader 
correspondence regarding the published manuscript may be addressed.  
The full names and e-mail addresses of all coauthors must be provided on the Authors & 
Institutes page upon submission of the manuscript in the ACS Paragon Plus Environment. 
Addition or deletion of an author or authors after submission of the manuscript requires 
justification from the corresponding author and is subject to approval by the Editor. 
Institution Address. The author affiliation(s) listed should be the institution(s) where the work 
was conducted. If the present address of an author differs from that at which the work was done, 
that address should be given in an Author Information note. 
Abstract. All manuscripts (Communications and Articles) must contain an abstract, which 
should summarize the reason for the work, the most significant results, and the conclusions. The 
abstract should not exceed about 250 words. Pasting the abstract in the text box on the Web 
submission page does not replace the need for including an abstract in the manuscript document.  
Text (Articles). The first paragraphs of an Article should explain the motivation for and import 
of the work, where it fits in the development of the field and of chemistry, and perhaps why it 
should be of interest to chemists in other areas. It should be possible to do this without 
excessively increasing the length of the Article. Extensive reviews of the literature cannot be 
C# PDF Text Redact Library: select, redact text content from PDF
application. Free online C# source code to erase text from adobe PDF file in Visual Studio. NET class without adobe reader installed.
delete text pdf files; how to delete text in pdf file
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit PDF
logo to PDF document, you and load and save it to current PDF file. Redact tab on viewer empower users to redact and erase PDF text, erase PDF images and erase
remove text from pdf acrobat; how to delete text in pdf preview
13 
accepted. Thoughtful use of schemes and figures (with well-composed captions) is 
recommended, so that even casual browsers can discern the nature of the work. Well-known 
procedures should be designated by name, or literature references to them should be given. 
Experimental results are of lasting value and should be clearly and logically presented in a 
separate section. Standard Article format must be used for preparing a manuscript for submission 
as an Article, including section headings and a proper Introduction, a complete Experimental 
Section (unless placed in the Supporting Information), Results, and Discussion. The addition of a 
Conclusion section at the end of the paper, which briefly summarizes the principal conclusions 
of the work, is recommended. If desired for clarification, section headings may be given Arabic 
numbers and subsections numbered in decimals (e.g., subsection 2.1 and subsection 2.2). 
Text (Communications). Section headings (Introduction, Experimental Section, Conclusion, 
etc.) should not be used in a Communication. 
Self-Citations. The use of excessive self-citations is not permitted. 
Disclaimers. Disclaimers are not allowed in JACS manuscripts or in the Supporting Information. 
Appendices. Appendix sections must be placed in the Supporting Information. 
Dedications. All dedications must appear in the Acknowledgment section and are subject to 
approval by the Editor. 
Abbreviations. Acronyms and abbreviations that are not broadly familiar to readers in all 
disciplines of chemistry should be introduced in parentheses following the full term on its first 
appearance in the text. Do not include a separate Abbreviations list. 
Acknowledgment. Dedications and notes acknowledging financial or professional assistance to 
the conduct of research or indicating presentation at a meeting should be brief and placed in the 
Acknowledgment section.  
Author Information Notes. The e-mail address(es) of the corresponding author or authors must 
be provided as a Corresponding Author note. Present addresses for individual authors that differ 
from the address(es) at which the work was done should be given in a Present Addresses note.  
Simple equal authorship statements are allowed and may be presented in an Author Contribution 
note.  However, itemization of individual author contributions or partial authorship is not 
permitted in any part of the manuscript or Supporting Information. 
Associated Content. A brief statement in non-sentence format must be included at the end of the 
manuscript, which describes any material placed in Supporting Information and the means by 
which the interested reader may obtain it. The following format should be used:
Supporting Information. Brief statement in nonsentence format listing the contents of the 
material supplied as Supporting Information. 
C# WPF Viewer: Load, View, Convert, Annotate and Edit PDF
Insert text box to PDF file. • Draw markups to PDF document. PDF Protection. • Add signatures to PDF document. • Erase PDF text. • Erase PDF images.
how to delete text in a pdf file; delete text from pdf acrobat
C# WinForms Viewer: Load, View, Convert, Annotate and Edit PDF
Add text box to PDF file in preview. • Draw PDF markups. PDF Protection. • Sign PDF document with signature. • Erase PDF text. • Erase PDF images.
how to copy text out of a pdf; how to delete text from a pdf
14 
A description of any Web Enhanced Objects (WEOs) must also be provided, in the following 
format: 
Web Enhanced. A WEO is available in the HTML version of the paper. 
For instructions on what material should be provided as 
µ
Supporting Information
¶ or µ
Web 
Enhanced Objects
¶ 
and on preparing it for publication, see the respective section below. 
Figures. Figures must include a caption giving the figure number and a brief description, 
preferably only one or two sentences. The caption should be understandable without reference to 
the text. It is preferable to place any key to symbols used in the artwork itself, not in the caption; 
colored symbols cannot be reproduced in the caption. Ensure that any symbols and abbreviations 
used in the text agree with those in the artwork. 
Schemes. Sequences of reactions are called schemes. Schemes may have brief titles describing 
their contents and footnotes, if needed, for further detail.  
Charts. Groups of structures that do not show reactions are called charts. Charts may have brief 
titles describing their contents and footnotes, if needed, for further detail. 
Tables. Tables should be used when the data cannot be presented clearly as narrative, when 
many numbers must be presented, or when more meaningful interrelationships can be conveyed 
by the tabular format. Tables should supplement, not duplicate, information presented in the text 
and figures. Tables should be simple and concise. Each table must have a brief (one phrase or 
sentence) title that describes the contents. The title should be understandable without reference to 
the text. Details should be put in footnotes, not in the title. Define nonstandard abbreviations in 
footnotes. Footnotes in tables should be given letter designations and be cited in the table by 
italic superscript letters. The sequence of letters should proceed by line rather than by column. If 
a reference is cited both in the text and in a table, a lettered footnote that refers to the numbered 
reference in the text should be placed in the table. 
Tables may be created using a word-
processor¶s text
mode or table format feature. The table 
format feature is preferred. Ensure that each data entry is in its own table cell. If the text mode is 
used, separate columns with a single tab and use a line feed (return) at the end of each row. In 
setting up tables, authors should keep in mind the type area of the JACS and should make tables 
conform to the limitations of these dimensions. 
All Figures, SchemesCharts, and Tables should be rendered legibly (please see the 
µ
Artwork
section for requirements) and must be mentioned in the text in consecutive order. Figures, 
Schemes, Charts, and Tables must be numbered consecutively with Arabic numerals and placed 
in the document within the text near the point of first mention. 
Web Enhanced Objects. The editors of the Journal of the American Chemical Society 
encourage the submission of Web 
enhanced objects (WEOs) that complement a reader¶s 
understanding of the research being reported. These types of files include color figures 
(including 3D rotatable figures), animations, spectra, video, and sound. Links to WEOs will 
appear in the Web HTML edition of the paper. Files suitable for this form of publication should 
be viewable with commonly available Internet plug-ins or helper applications. More information 
on Specifications for Web Enhanced Objects is available on the Web. Authors should submit 
C# HTML5 PDF Viewer SDK to view, annotate, create and convert PDF
Able to protect PDF document from editing, printing, copying and commenting by setting PDF file permissions. Help C# users to erase PDF text content, images and
acrobat remove text from pdf; how to erase text in pdf
C# PDF Image Redact Library: redact selected PDF images in C#.net
call our image redaction API to redact PDF images. as text redaction, you can specify custom text to appear How to Erase PDF Images in .NET Using C# Class Code.
remove text from pdf reader; acrobat delete text in pdf
15 
WEOs via the Paragon Plus Web site as part of their submissions, using the file type designation 
³Web Enhanced Object´. Descriptions of WEOs
should be included in the appropriate places 
within the related graphic caption or text of the paper and summarized in the Associated Content 
section, noting the type of file and 
format. Example: ³A 3D rotatable image in xyz format is 
available.´
References and Footnotes. All the references and footnotes must be placed together in a list at 
the end of the manuscript text. In the Web edition, many of them will have links to other Web 
resources, such as the corresponding abstracts in Chemical Abstracts and the full text on 
publisher Web sites. Because of this electronic linking, and to aid scientific research, it is crucial 
that authors verify the accuracy of all reference citations and footnotes. 
Unnecessarily long lists of references should be avoided, and excessive self-citation is not 
permitted. However, authors must reference all previous publications in which portions of the 
present work have appeared. Literature references and explanatory footnotes must be numbered 
with Arabic numerals in the order of their first citation in the text and the corresponding numbers 
placed at the appropriate locations in the text as superscripted numerals. 
Long footnotes should be avoided; additional data and peripheral discussion should be placed in 
the Supporting Information rather than in footnotes. Supplementary references may be placed in 
Supporting Information. 
Bibliographic references to classified documents and reports or references to unpublished 
materials that are not generally available to the scientific public should not be used. Authors 
must obtain written permission from any person whose work is cited as a personal 
communication, unpublished work, or work in press. Copies of letters of permission and 
documentation should be appended to the cover letter file. If the manuscript is accepted but the 
necessary permissions have not been received, the Editor will ask the author to remove the 
reference(s) and dependent text. 
Authors should consult The ACS Style Guide, 3rd ed.; American Chemical Society: Washington, 
DC, 2006, for the appropriate style to use in citations of journal papers, books, and other 
publications. In literature references, journal abbreviations should be those used in the Chemical 
Abstracts Service Source Index (CASSI)
Nomenclature. Registered trademark names should be capitalized whenever used. Trade and 
trivial names should not be capitalized. It is not necessary to use the trademark, registered 
trademark, or service mark symbol to ensure legal protection for the trademark. 
Artwork 
General Considerations. Submission of graphics (illustrations) that are to be considered for 
publication in color is strongly encouraged. Color may be used to enhance the clarity of complex 
structures, figures, spectra, schemes, etc., and color reproduction of graphics is provided at no 
cost to the author. Graphics intended to appear in black and white or grayscale should not be 
submitted in color.  
To facilitate the publication process, the preferred submission procedure is to embed (paste) 
graphic files into the manuscript Word document near the point of first mention. Most graphic 
How to C#: Special Effects
Erase. Set the image to current background color, the background color can be set by:ImageProcess.BackgroundColor = Color.Red. Encipher.
how to delete text from pdf with acrobat; deleting text from a pdf
Customize, Process Image in .NET Winforms| Online Tutorials
Include crop, merge, paste images; Support for image & documents rotation; Edit images & documents using Erase Rectangle & Merge Block function;
how to delete text from pdf document; online pdf editor to delete text
16 
programs provide an option for changing the resolution (see below) when you are saving the 
image in the chosen file format. Best practice is to save the graphic file at the final resolution and 
size using the program used to create the graphic and then paste the graphic into the manuscript 
document. It may help to print the manuscript on a laser printer to ensure all artwork is clear and 
legible. 
Individual graphics files, created by the author according to the following guidelines, may be 
uploaded to the ACS Paragon Plus Environment with the submitted manuscript. 
File Specifications. Acceptable file formats are TIFF, PDF, EPS (vector artwork), or CDX 
(ChemDraw file). When submitting individual graphics, name the files based on graphic function 
(i.e., Scheme1, Figure2, Chart3, eq4, compd5), not the scientific name. Labels for multi-part 
figures should be present, and the parts should be assembled into a single graphic. 
For TIFF files (either embedded in a Word document or submitted as individual files), the 
resolution requirements are as follow: 
black & white line art: 1200 dpi 
grayscale art (a monochromatic image containing shades of gray): 600 dpi 
color art (RGB color mode): 300 dpi 
The RGB color mode and resolution requirements are essential for producing high-quality 
graphics within the published manuscript. Graphics submitted in CMYK or at lower resolutions 
may be used; however, the colors may not be consistent and graphics of poor quality may not be 
able to be improved. Graphics submitted at higher resolutions will be reduced to the resolution 
specified for the type of art as listed above. 
For EPS files, ensure that all fonts are converted to outlines or embedded in the graphic file. The 
document settings should be in RGB mode. NOTE: While EPS files are accepted, the vector-
based graphics will be rasterized for production. 
Chemical structures should be produced with the use of a drawing program such as ChemDraw.  
Size. Graphics should be submitted at the final publication size. Single-column graphics are 
preferred and can be sized up to 240 points wide (3.33 in.). Double-column graphics must be 
sized between 300 and 504 points (4.167 in. and 7 in.). The maximum depth for all graphics is 
660 points (9.167 in.) including the caption (please allow 12 pts for each line of caption text). 
Consistent sizing of letters, numbers, and labels in graphics throughout the manuscript will help 
ensure uniform graphic presentation for publication. Lettering should be no smaller than 4.5 
points. Helvetica or Arial fonts work well for lettering. Lines should be no thinner than 0.5 point. 
Note that all graphics are subject to approval by the Editor. 
Table of Contents (TOC) and Abstract Graphics. A graphic should be submitted for use on 
the TOC; the same graphic may also appear along with the abstract. This graphic should give the 
reader a quick visual representation of the essence of the paper without providing specific 
details. The best images for these uses are simple and relatively free of text and technical 
.NET Imaging Processing SDK | Process, Manipulate Images
Provide basic transformation functions, like Crop, Rotate, Resize, Flip and more; Basic image edit function support, such as Erase Rectangle, Merge Block, etc.
delete text from pdf; how to edit and delete text in pdf file online
17 
characters, and the use of color for visual impact is encouraged. Copyrighted images or TOC 
graphics that are not made by the author(s) should be avoided.  
Additional TOC Guidelines: 
The graphic should uphold the standards of a scholarly, professional publication. 
The graphic must be entirely original, unpublished artwork created by one of the 
coauthors. 
The graphic should not include a photograph, drawing or caricature of any person, living 
or deceased. 
Do not include postage stamps or currency from any country, or trademarked items 
(company or institutional logos, images, and products). 
TOC graphics are subject to approval by the Editor. 
Cover Art. JACS will feature a different image on the cover of each issue, and images chosen 
for the cover will be printed at no cost to the author. After favorable review, authors are invited 
to submit artwork suitable for consideration as a cover graphic. Cover art should be colorful and 
eye-catching and must convey the importance and significance of the research. Graphics in EPS, 
TIFF, JPEG, or PNG format (not PDF) should be 7.4 inches wide and 8.1 inches high, with a 
minimum resolution of 300 dpi (2100 × 2400 pixels), 
and submission of ³layered´ artwork is 
encouraged. Cover art files, as well as a short (<50-word), clear caption explaining the image, 
may 
be uploaded to ACS Paragon Plus as ³Supporting Information for Review Only´ during the 
final revision process. Upon manuscript acceptance, request for cover art should be sent directly 
to the Editor, Peter J. Stang (jacs@jacs.acs.org), for consideration. Submitted images are 
evaluated and final selection is made by the Editor. These images may be modified or enhanced 
by an ACS graphic artist. Cover art may delay issue publication of the associated Article or 
Communication; however, ASAP publication will not be delayed. 
For more information on working with graphics, please visit 
http://pubs.acs.org/page/4authors/submission/graphics_prep.html. 
Compound Characterization and Computational Data 
Characterization of New Substances. Adequate evidence to firmly establish both identity and 
purity should be provided. Recommended criteria vary according to substance categories. A 
summary of the detailed criteria may be found on the Web in the JACS Information for Authors
Spectra. Reproductions of spectra, or the relevant segments thereof, will be published only if 
concise numerical summaries are inadequate for the purposes of the paper. Papers dealing 
primarily with interpretation of spectra and those in which band shape or fine structure needs to 
be illustrated may be published with such spectra included. Spectra will not be published merely 
as adjuncts to the characterization of compounds, however. S
ee µ
Supporting Information
¶ below. 
Routine infrared, electronic, NMR, and mass spectra of new compounds should be numerically 
summarized, as appropriate, in the Experimental Section of an Article or in the Supporting 
Information of a Communication. 
Kinetic and Equilibrium DataFor publication in the Journal of the American Chemical 
Society, the reporting of kinetic data and equilibrium binding data for proteins, nucleic acids, and 
18 
other species should preferably include a description of the identity of the catalyst or binding 
molecule, its origin, purity of composition, and any modifications such as mutations, post-
translational modifications, or other modifications made to facilitate expression and purification. 
The method of assay and the exact experimental conditions of the assay should be provided as a 
reference to previous work, with or without modifications, or fully described if a new assay. 
Conditions essential to reproduce the results such as the temperature, pH, and pressure (if other 
than atmospheric) of the assay should 
be included. Terms such as ³not detectable´ (ND) should 
be avoided. Instead, an estimate of the limit of detection based on the sensitivity and error 
analysis of the assay should be provided. Authors are referred to the STRENDA (Standards for 
Reporting Enzymology Data) Commission of the Beilstein Institut (http://www.beilstein-
institut.de/en/projects/strenda/guidelines) for an example of detailed guidelines. 
Reporting and Stewardship of NMR Data. New guidelines recommend a standard baseline for 
the submission of NMR data to ACS journals. They are intended to promote accuracy and 
consistency. The guidelines are divided into  three sections: NMR text,  which outlines the 
preferred format for NMR data included in the Experimental Section; NMR spectra, which 
outlines  the  preferred  format  for  inclusion  of  hard  copies  of  spectra  in  the  Supporting 
Information; and primary NMR data files, which outlines the procedure for submitting FID files, 
acquisition data, and processing parameters to include in the Supporting Information. Authors 
are strongly encouraged to provide all three sets of data for all new and/or key compounds 
described in a manuscript submission. 
In the Experimental Section, the compound must be clearly identified, for example in a header at 
the beginning of the synthetic procedure or the summary of spectroscopic data. List the nucleus 
being measured, any nucleus being broad-band decoupled, the solvent used (formula preferred, 
e.g. C
6
D
6
over benzene-d
6
), the standard used, and the field strength. Field strength should be 
noted for each spectrum, not as a comment in the general Experimental Section. The standard(s) 
may be specified in the general experimental section; as an example, 
1
H NMR data recorded in 
C
6
D
6
listed as ³residual internal C
6
D
5
H (
į
7.15)´.
Indicate solvent or peak suppression protocols 
used in collecting data. List the probe temperature when it is accurately known; ambient probe 
temperature is otherwise understood. Give 
1
H NMR chemical shifts to two digits after the 
decimal point. Include the number of protons represented by the signal, peak multiplicity, and 
coupling constants as needed (J italicized, reported with up to one digit after the decimal). The 
number of bonds through which the coupling is operative, 
x
J, may be specified by the author if 
known with a high degree of certainty. Accepted abbreviations for multiplicities and descriptors 
are s = singlet, d = doublet, t = triplet, q = quartet, quint = quintet, m = multiplet (denotes 
complex pattern), dd = doublet of doublets, dt = doublet of triplets, td = triplet of doublets, and 
br = broad signal. 
Chemical shifts should be listed consistently in a single article, starting either from downfield to 
upfield or vice-versa. Assign peak identities under the following circumstances: non-decoupled 
or equivalent spectra have been collected (
13
C, 
31
P, etc.); 2-D experiments have been performed; 
or unambiguous assignment is possible without additional experiments, such as in the case of an 
organometallic metal-hydride 
1
H signal, PF
6
vs MPPh
3
31
P signal, etc. Give 
13
C chemical shifts 
to one digit after the decimal point, unless an additional digit will help distinguish overlapping 
peaks.  Include  peak  multiplicities for 
1
H-coupled 
13
C  NMR spectra  or  for  signals in 
1
H-
decoupled spectra that are coupled to other magnetically active nuclei. A 
13
C NMR signal will be 
considered a singlet if the multiplicity is not assigned. Only rarely is a true multiplet observed in 
19 
13
C{
1
H} NMR spectrum. However, a certain region may contain a group of unresolved peaks 
or signals. Mention of unobserved resonances is encouraged. 
See µ
Supporting Information
¶ below for instructions about submission of spectra.
Structural and Chemical Shift Data for Proteins and Nucleic Acids. Any set of atomic 
coordinates referred to in the manuscript, including atomic coordinates and structure factors for 
proteins determined by X-ray crystallography and coordinates determined by NMR, should be 
deposited with the Protein Data Bank, Research Collaboratory for Structural Bioinformatics at 
Rutgers University whenever appropriate. (Theoretical model depositions are no longer accepted 
for inclusion in the PDB archive.) If the coordinate files are not deposited in the PDB, or if the 
PDB files are on hold until publication, then the coordinate files must be included in the 
Supporting Information submitted concurrently with the manuscript. Requirements are similar 
for structures of nucleic acids, which should be deposited with the Nucleic Acid Database. A 
manuscript that does not provide coordinates at the time of submission will not be sent out for 
review. It is the responsibility of the author to obtain a file name (PDB ID or NDB ID) for the 
molecule; the file name must appear in the published manuscript. If a file name has not yet been 
obtained upon acceptance of a paper, it must be added in proof. Atomic coordinates and structure 
factors for all structures mentioned must be available immediately upon publication of the paper, 
either directly in the Supporting Information or as a data bank deposition. Similar requirements 
also apply to any chemical shifts referred to in the paper, whether they are only for assignment of 
resonances or used for any form of structure calculation. Those chemical shifts must be available 
to the reviewer at time of submission, either as an available entry in the Biological Magnetic 
Resonance Data Bank or included directly as Supporting Information. 
Single Crystal Diffraction Data. Manuscripts reporting the determination of one or more 
structures by X-ray diffraction must adhere to the following requirements: 
Abstract. The abstract may summarize geometric features of unusual interest but should not 
contain unit cell parameters. 
Main Body of Manuscript. Tables of essential interatomic distances and angles are not required 
but may be submitted (metric information for standard structural components should not be 
included). 
For structures with anisotropically refined atoms, a figure displaying the thermal ellipsoids 
should ordinarily be presented; a spherical-atom representation may be substituted if necessary 
for clarity. If a spherical atom view is chosen for the manuscript, a thermal ellipsoid figure 
should be included in the Supporting Information. In cases where intermolecular interactions are 
relevant to the discussion, a view of the unit cell may be included. 
An Article should list for each structure the formula, formula weight, crystal system, space 
group, color of crystal, unit cell parameters, temperature of data collection, and values of ZR
and GOF; a brief description of data collection and solution and refinement of the structure 
should be placed in the Experimental Section. Tables of atom coordinates and thermal 
parameters will not be printed. 
Supporting Information. Complete detailed data for each structure must be submitted in the 
electronic Crystallographic Information File (CIF) format. Deposition of CIF files in the 
20 
Cambridge Crystallographic Data Centre (CCDC) does not eliminate the JACS requirement to 
submit the CIF file(s) as Supporting Information. 
Authors are requested to combine multiple CIFs for a given manuscript into a single file. The 
individual structures in the combined file are to be separated from each other by the sequence 
#===END at the beginning of a new line. JACS requires authors to run the CheckCIF program 
for each crystallographic structure and to correct any syntax errors in the CIF file prior to 
submission. Authors should consult the JACS Information for Authors for CIF Submission 
Instructions during manuscript preparation. 
Structure factors (except for proteins and nucleic acids) should not be submitted as Supporting 
Information. However, one printed table of structure factors should be retained in case it is 
requested by the Editor for review purposes only. 
Powder Diffraction Data. The presentation of X-ray powder diffraction data for new materials 
or for materials previously uncharacterized by this technique is encouraged. Data from X-ray 
powder measurements should be accompanied by details of the experimental technique: source 
of X-rays, the radiation, its wavelength, filters or monochromators, camera diameter, the type of 
X-ray recording, and the technique for measuring intensities. In cases of unindexed listing of the 
data, the spacings of all observed lines should be listed in sequence, together with their relative 
intensities. In cases where filtered radiation is used, every effort should be made to identify 
residual 
β
lines. Where resolution into 
Į
1
-
Į
2
doublets occurs, the identification of the spacing 
for each line as d
Į
1
d
Į
2
gives a measure of the quality of the diffraction pattern. When an 
indexing of the data is offered, the observed and calculated 1/d
2
values should be listed along 
with the observed relative intensities (it is superfluous to give spacings in this instance). All 
calculated 1/d
2
values should be listed (exclusive of systematic absences), to the limit of the data 
quoted. If possible, the crystal system should be specified. Possible space groups may also be 
listed if the data warrant it. Relevant information about the specimen used should be included. 
Magnetic Measurements. Fits of magnetic data [
χ
(T), 
χ
-1
(T), 
χ
T(T), 
μ
(T), M(H), etc.] to an 
analytical expression must include both the Hamiltonian from which the analytical expression is 
derived and the final analytical expression and fitting parameters. When the value of an 
exchange coupling constant, J, is given in the abstract, the form of the Hamiltonian must also be 
included. The expressions may be included in the manuscript or, if long and complex, as 
Supporting Information; if the latter method is used, it should be noted in the Supporting 
Information paragraph at the end of the manuscript. In addition, how the sample was measured 
(in a gelatin capsule, Teflon capsule, etc.) and the diamagnetic correction for the sample holder, 
as well as the diamagnetic correction for the material, must be provided and the manner in which 
it was calculated (Pascal¶s constants)
or measured must be stated. 
Computations. When computational results are an essential part of a manuscript, sufficient 
detail must be given, either within the paper or in the Supporting Information, to enable readers 
to reproduce the calculations. This includes data such as force field parameters and equations 
defining the model (or references to where such material is available in the open literature). If the 
software used for calculations is generally available, it must be properly cited in the References 
and Footnotes. References to the methods upon which the software is based must also be 
provided. Results obtained from methods or parameters that are not adequately described in the 
manuscript or in the literature are not acceptable for publication. Authors who report the results 
of electronic structure calculations are requested to provide as Supporting Information the 
Documents you may be interested
Documents you may be interested