SIEMENS AG    6RX1700-0AD76 
8-133 
SIMOREG DC-MASTER    Operating Instructions 
Sheet Z145  SCB1 with SCI2 as slave 1: binary outputs  
8
7
5
6
4
3
2
1
- Z145 -
X439
X438
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
.01
.02
.03
.04
.06
.07
.08
.05
B1
B2
02
12
22
32
42
52
62
72
.10
.11
.12
.09
B3
B4
B5
B6
A1
A2
A3
A4
82
92
12
12
P24
M
A5
A6
U698 (0)
B B B B B B B B B B
n699.09
B B B B
SCB1 with SCI2 as slave 1: 
binary outputs
Binary output 8
Binary output 9
Binary output 10
Binary output 11
Binary output 12
Auxiliary voltage P24 VDC
Auxiliary voltage M for
binary outputs
Binary output 1
Binary output 2
Binary output 3
Binary output 4
Binary output 5
Binary output 6
Binary output 7
Adding an image to a pdf form - insert images into PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Sample C# code to add image, picture, logo or digital photo into PDF document page using PDF page editor control
add photo to pdf; add jpg to pdf document
Adding an image to a pdf form - VB.NET PDF insert image library: insert images into PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide VB.NET Programmers How to Add Images in PDF Document
how to add a picture to a pdf document; add picture to pdf document
8-134
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
Sheet Z146  SCB1 with SCI2 as slave 2: binary outputs  
8
7
5
6
4
3
2
1
- Z146 -
X439
X438
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
.13
.14
.15
.16
.18
.19
.20
.17
B1
B2
02
12
22
32
42
52
62
72
.22
.23
.24
.21
B3
B4
B5
B6
A1
A2
A3
A4
82
92
12
12
P24
M
A5
A6
U698 (0)
B B B B B B B B B B
n699.13
B B B B B
SCB1 with SCI2 as slave 2: 
binary outputs
Binary output 8
Binary output 9
Binary output 10
Binary output 11
Binary output 12
Auxiliary voltage P24 VDC
Auxiliary voltage M for
binary outputs
Binary output 1
Binary output 2
Binary output 3
Binary output 4
Binary output 5
Binary output 6
Binary output 7
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Support adding PDF page number. Offer PDF page break inserting function. DLLs for Adding Page into PDF Document in VB.NET Class. Add necessary references:
how to add jpg to pdf file; how to add image to pdf acrobat
VB.NET PDF Library SDK to view, edit, convert, process PDF file
PDF document to/from supported document and image forms. to define text or images on PDF document and Capable of adding PDF file navigation features to your VB
add picture to pdf preview; add image to pdf form
SIEMENS AG    6RX1700-0AD76 
8-135 
SIMOREG DC-MASTER    Operating Instructions 
Sheet Z150  SCB1 with SCI1 as slave 1: analog inputs  
8
7
5
6
4
3
2
1
- Z150 -
X428
U±10V
I
±20mA
1
2
3
4
5
6
7
8
9
10
11
3
4
4
5
<2>
<2>
<2>
<1>
<1>
<1>
<2>
<1>
U692.01(0)
U691.01(2)
n699.02
K4101
0...2
U690.01(0)
-20,00...20,00V
0...15
U692.02(0)
U691.02(2)
n699.03
K4102
0...2
U690.02(0)
-20,00...20,00V
0...15
U692.03(0)
U691.03(2)
n699.04
K4103
0...2
U690.03(0)
-20,00...20,00V
0...15
SCB1 with SCI1 as slave 1: analog inputs
Hardware-
Smoothing 1ms
Offset
Hardware-
Smoothing 1ms
Offset
Hardware-
Smoothing 1ms
Offset
+10 V / 5 mA for potentiometer, short-circuit-proof
-10 V / 5 mA for potentiometer, short-circuit-proof
Smoothing
Smoothing
Smoothing
USmoothing time constant T = 2 ms * 2
U690 
Voltage input 
Current input
Kl. X428.3, .6, .9 
 Kl. X428.5, .8, .11
   0 
-10 ... 10 V 
-20 ... 20 mA
   1 
   0 ... 10 V 
   0 ... 20 mA
   2 
       - 
   4 ... 20 mA
Analog input 2
Analog input 3
Analog input 1
SCI Slave 1
Signal type
Signal type
Signal type
Signal type
12 bits + sign
A
D
A
D
A
D
12 bits + sign
12 bits + sign
Changes to parameters U690, U691 or U692 do not take 
effect until the system is reconfigured (e.g. using U710=0).
C# PDF Page Insert Library: insert pages into PDF file in C#.net
By using reliable APIs, C# programmers are capable of adding and inserting (empty) PDF page or pages from various file formats, such as PDF, Tiff, Word, Excel
adding images to pdf; add image to pdf
C# PDF insert text Library: insert text into PDF content in C#.net
Supports adding text to PDF in preview without adobe reader installed in ASP.NET. Powerful .NET PDF edit control allows modify existing scanned PDF text.
add photo to pdf online; add jpg to pdf file
8-136
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
Sheet Z151  SCB1 with SCI1 as slave 2: analog inputs  
8
7
5
6
4
3
2
1
- Z151 -
X428
U ±10V
I
±20mA
1
2
3
4
5
6
7
8
9
10
11
3
4
4
5
<2>
<2>
<2>
<1>
<1>
<1>
<2>
<1>
U692.04(0)
U691.04(2)
n699.06
K4201
0...2
U690.04(0)
-20,00...20,00V
0...15
U692.05(0)
U691.05(2)
n699.07
K4202
0...2
U690.05(0)
-20,00...20,00V
0...15
U692.06(0)
U691.06(2)
n699.08
K4203
0...2
U690.06(0)
-20,00...20,00V
0...15
SCB1 with SCI1 as slave 2: 
a
nalog inputs
Hardware-
Smoothing 1ms
Offset
Hardware-
Smoothing 1ms
Offset
Hardware-
Smoothing 1ms
Offset
+10 V / 5 mA for potentiometer, short-circuit-proof
-10 V / 5 mA for potentiometer, short-circuit-proof
Smoothing
Smoothing
Smoothing
USmoothing time constant T = 2 ms * 2
U690 
Voltage input 
Current input
Kl. X428.3, .6, .9 
 Kl. X428.5, .8, .11
   0 
-10 ... 10 V 
-20 ... 20 mA
   1 
   0 ... 10 V 
   0 ... 20 mA
   2 
       - 
   4 ... 20 mA
Analog input 2
Analog input 3
Analog input 1
SCI Slave 2
Signal type
Signal type
Signal type
Signal type
12 bits + sign
12 bits + sign
12 bits + sign
A
D
A
D
A
D
Changes to parameters U690, U691 or U692 do not take 
effect until the system is reconfigured (e.g. using U710=0).
C# PDF Library SDK to view, edit, convert, process PDF file for C#
Capable of adding PDF file navigation features to your C# program. You may easily generate thumbnail image from PDF. C#.NET: PDF Form Field Edit.
adding image to pdf in preview; adding an image to a pdf in preview
VB.NET Image: How to Draw Annotation on Doc Images with Image SDK
multi-page TIFF, Microsoft Office Word and PDF file programmer, you might need some other image annotating tutorials besides adding annotation using VB
add an image to a pdf form; add png to pdf acrobat
SIEMENS AG    6RX1700-0AD76 
8-137 
SIMOREG DC-MASTER    Operating Instructions 
Sheet Z155  SCB1 with SCI1 as slave 1: analog outputs  
8
7
5
6
4
3
2
1
y
y [V] = 
*U694.01
x
100%
14
12
M
- Z155 -
X428
U
I
x
13
y
y [V] = 
*U694.02
x
100%
17
15
M
U
I
x
16
y
y [V] = 
*U694.03
x
100%
20
18
M
U
I
x
19
-100,00...+100,00V
-320,00...+320,00V
U694.01 (10,00)
U693.01(0)
K
U695.01 (0,00)
n699.10
-100,00...+100,00V
-320,00...+320,00V
U694.02 (10,00)
U693.02(0)
K
U695.02 (0,00)
n699.11
-100,00...+100,00V
-320,00...+320,00V
U694.03 (10,00)
U693.03(0)
K
U695.03 (0,00)
n699.12
Iout = -20 ... 20 mA
Iout = -20 ... 20 mA
Iout = -20 ... 20 mA
Analog output 1
DA
SCB1 with SCI1 as
slave 1
 
a
nalog outputs
Gain
Offset
Analog output 2
DA
Gain
Offset
Analog output 3
DA
Gain
Offset
Changes to parameters U694 or U695 do not take 
effect until the system is reconfigured (e.g. using U710=0).
C# PDF Password Library: add, remove, edit PDF file password in C#
Following are examples for adding password to a plain PDF passwordSetting.IsAnnot = true; // Allow to fill form. IsAssemble = true; // Add password to PDF file
how to add picture to pdf; adding image to pdf
VB.NET PDF File & Page Process Library SDK for vb.net, ASP.NET
merge and splitting PDF pages and Files, adding a page is the programmatic representation of a PDF document. of newly created blank pages or image-only pages
add signature image to pdf; add an image to a pdf
8-138
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
Sheet Z156  SCB1 with SCI1 as slave 2: analog outputs  
8
7
5
6
4
3
2
1
y
y [V] = 
*U694.04
x
100%
14
12
M
- Z156 -
X428
U
I
x
13
y
y [V] = 
*U694.05
x
100%
17
15
M
U
I
x
16
y
y [V] = 
*U694.06
x
100%
20
18
M
U
I
x
19
-100,00...+100,00V
-320,00...+320,00V
U694.04 (10,00)
U693.04(0)
K
U695.04 (0,00)
n699.14
-100,00...+100,00V
-320,00...+320,00V
U694.05 (10,00)
U693.05(0)
K
U695.05 (0,00)
n699.15
-100,00...+100,00V
-320,00...+320,00V
U694.06 (10,00)
U693.06(0)
K
U695.06 (0,00)
n699.16
Iout = -20 ... 20 mA
Iout = -20 ... 20 mA
Iout = -20 ... 20 mA
Analog output 1
DA
SCB1 with SCI1 as
slave 2
 
a
nalog outputs
Gain
Offset
Analog output 2
DA
Gain
Offset
Analog output 3
DA
Gain
Offset
Changes to parameters U694 or U695 do not take 
effect until the system is reconfigured (e.g. using U710=0).
SIEMENS AG    6RX1700-0AD76 
9-1 
SIMOREG DC-MASTER    Operating Instructions 
Function descriptions 
NOTE
The available scope of converter functions is shown in the function diagrams (block diagrams) in 
Section 8. 
Section 9 does not attempt to provide a complete description of all these functions, but to explain 
in further detail certain individual features, which cannot be adequately illustrated in graphic 
form, and provide examples of their application. 
9.1  General explanations of terms and functionality 
Function blocks 
Although the illustrated function blocks
have been implemented in digital form (as software modules), 
the function diagrams can be "read" in a similar way to the circuit diagrams of analog equipment. 
Configurability 
The converter is characterized by the optional configurability
of the function blocks provided. "Optional 
configurability" means that the connections
between individual function blocks can be selected by 
means of parameters
Connectors 
All output variables and important computation quantities within the function blocks are available in the 
form of "connectors"
(e.g. for further processing as input signals to other function blocks). The 
quantities accessed via connectors correspond to output signals
or measuring points
in an analog 
circuit and are identified by their "connector number"
(e.g. K0003 = connector 3). 
Special cases: K0000 to K0008 are fixed values with signal levels corresponding to 0, 100, 200, -100,  
-200, 50, 150, -50 and -150%. 
K0009 is assigned to different signal quantities. Which signal quantity it actually refers 
to is dependent on the selector switch (parameter) at which connector number 9 is set. 
A description can be found under the relevant parameter number in the Parameter List. 
If the Parameter List or block diagram does not contain any reference to a special 
function in relation to selection of connector K0009, then the selector switch 
(parameter) concerned must not be set to "9". 
The internal numerical representation of connectors in the software is generally as follows:  
100% corresponds to 4000 hexadecimal = 16384 decimal. The resolution is 0.006% (step change). 
Connectors have a value range of -200% to +199.99%. 
For a list of available connectors, please refer to Section 12. 
Example
 The data received via peer-to-peer 2 are available at connectors K6001 to K6005  
(Section 8, Sheet G173) 
Tx+
Tx-
Rx+/Tx+
Rx-/Tx-
RS485
M
56
57
58
59
60
G-SST2
X172
1
0
9-2 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
Double-word connectors (SW 1.9 and later) 
Double-word connectors are connectors with a 32-bit value range (i.e. LOW word and HIGH word with 
a double-word value range of 00000000Hex to FFFFFFFFHex ). 
-100 % to +100 % corresponds to connector values of C0000000 Hex to 40000000 Hex  
(= -1073741824 to +1073741824 decimal). This means that the value range in the upper 16 bits 
(HIGH word) of a double-word connector is the same as for a "normal" connector (C000 Hex to 4000 
Hex or -16384 to +16384 decimal for -100 % to +100 %). The extra 16 bits in the LOW word as 
compared to a "normal connector" afford, therefore, an improved resolution of the connector value by 
a factor of 65536. For information about how to use double-word connectors see also the section in 
"The following rules apply to the selection of double-word connectors" below. 
Double-word connector symbol in function diagrams: 
KK9498
Binectors 
All binary output quantities and important binary output signals of the function blocks are available as 
"Binectors"
(connectors
for bin
ary signals). Binectors can assume states log. "0" and log."1". The 
quantities accessed via binectors correspond to output signals
or measuring points
in a digital circuit 
and are identified by their "Binector number"
(e. g. B0003 = binector 3). 
Special cases:  B0000 = Fixed value log."0"  
B0001 = Fixed value log."1" 
A list of available binectors can be found in Section 12. 
Example
 The status of terminal 36 is available at B0010 and, in inverted form, at binector B0011 
(Section 8, Sheet G110) 
1
24V
5V
36
M
B0011
B0010
Selection switches, connections 
(see also Section "Data sets") 
The inputs
of function blocks are defined at "selection switches"
by setting the appropriate selection 
parameters. The input is defined by entering the number of the connector or binector to be applied as 
the input quantity in the parameter for the relevant selection switch. 
Representation in function diagrams (examples): 
P750 (0)
K
Selection of a connector 
Parameter number = P750, factory setting = 0 (i. e. fixed value 0%) 
P704 (0)
B
Selection of a binector 
Parameter number = P704, factory setting = 0 (i. e. fixed value 0) 
.01
.02
.03
.04
P613 (1)
K
K
K
K
Selection of connectors ("indexed" parameter with 4 indices) 
Parameter number = P613, factory setting = 1 (i. e. fixed value 100%; this factory 
setting applies to all the indices of P613) 
.01
.02
.03
.04
277
0
0
0
P611
K
K
K
K
FS
Selection of connectors ("indexed" parameter with 4 indices) 
Parameter number = P611 
Factory setting for index .01 = 277 (i. e. connection with connector K0277) 
Factory setting for indices .02 to .04 = 0 (i. e. fixed value 0%) 
SIEMENS AG    6RX1700-0AD76 
9-3 
SIMOREG DC-MASTER    Operating Instructions 
P046 (0)
B
B
B
B
.01
.02
.03
.04
Selection of binectors ("indexed" parameter with 4 indices) 
Parameter number = P046, factory setting = 0 (i. e. fixed value 0, this factory setting 
applies to all the indices of P046) 
U181 (0)
KK
Selection of a double-word connector (SW 1.9 and later) 
Parameter number = U181, factory setting = 0 (i.e. fixed value 0%) 
The selected setting can be entered in the empty field (fields). The value in brackets next to the 
parameter number is the factory setting of the selection parameter. 
The following rules apply to the selection of double-word connectors (SW 1.9 and later):
U181 (0)
KK
KK9498
9498
Double-word connector to double-word connector selection: 
The double word for subsequent processing comprises: 
LOW word = LOW word of double-word connector (KK9498) 
HIGH word = HIGH word of double-word connector (KK9498) 
U181
KK
K0401
401
Connector to double-word connector selection: 
The double word for subsequent processing comprises: 
LOW word = 0 
HIGH word = selected connector (K0401) 
P044
K
KK9498
9498
Double-word connector to connector selection: 
HIGH word of the double-word connector (KK9498) is connected to 
another block, 
the LOW word of the double-word connector (KK9498) is not used 
.01
.02
U751 (0)
9498
9498
KK9498
KK9498
L
H
K
K
There are exceptions in the selection of transmission data for the serial 
interfaces and in the transmission of optional expansion modules 
(technology and communications modules, SIMOLINK module): 
If the same double-word connector is entered in two contiguous indices of 
the selection parameter, the entire value (the LOW and HIGH word) will be 
used. 
.01
.02
U751 (0)
KK9498
KK9499
H
H
9498
9499
K
K
If different double-word connectors are entered in two contiguous indices 
of the selection parameter, in both cases only the HIGH word of the two 
double-word connectors will be used. 
9-4 
SIEMENS AG    6RX1700-0AD76
SIMOREG DC-MASTER    Operating Instructions 
Examples:
Some examples of how to handle connectors and binectors are given below. 
Example 1:  As a function of the status of terminal 36 (B0010 - see Section 8, Sheet G110), analog 
selectable input 1 (terminals 6 and 7) must be made available, either with the correct 
sign or inverted sign, at the function block output (= connector K0015). 
This output value must then be injected as an additional setpoint and output 
simultaneously at analog output terminal 14. 
The following settings need to be made to create the correct links: 
1. P714 = 10:  Selects binector B0010 (status of terminal 36) as the control signal for sign reversal. 
Parameter P716 remains set at 1 (= fixed value 1, delivery state), thereby ensuring that 
the analog input is switched in continuously. 
Section 8, Sheet G113:
0
1
-1
-1
1
2
3
0
Documents you may be interested
Documents you may be interested